Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations



Similar documents
Inductive Proximity Sensors

A1000 Cheat Sheet (Open Loop Vector)

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

MEMOBUS/Modbus Communications

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

ABB Drives. User s Manual HTL Encoder Interface FEN-31

8 Channel Status Input Panel model SIP-8

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Digital Expansion Modules Specifications

Contents. Document information

GPD 506/P5 Start-up Procedure and Checklist

The multi-functional integrator Supercal 531

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

J1000. System configuration

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

WD-AMX Water Detection Controllers

Application/Connection Examples

How to make a diagnostic on TeSysT to start the network?

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

VLT 6000 HVAC. Contents

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Modular I/O System Analog and Digital Interface Modules

THE INPUT/OUTPUT SYSTEM. Key Points

conventional system operation

IO-RM3 3-Stage Relay Module

SX460. Generator Automatic Voltage Regulator Operation Manual

3FBD DC Motor Drive User Manual

Allen-Bradley/Rockwell

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Inductive sensor NI10-M18-Y1X-H1141

MOTION COORDINATOR MC206X Quick Connection Guide

VCM Installation and Operations Manual. Table of Contents

User Manual. MODBUS-RTU Option Board for SV-iS5 Series. LG Industrial Systems

DCS Input/Output Relay Card Series

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Programmable Logic Controller PLC

Kurz Instruments Inc. Document AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Temp. & humidity Transmitter Instructions

Advantium 2 Plus Alarm

Industrial Automation Training Academy. PLC, HMI & Drives Training Programs Duration: 6 Months (180 ~ 240 Hours)

DCS Series 1 kw, 1.2 kw, & 3 kw

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Automatic Voltage Regulator User s Manual

SYSTEM 45. C R H Electronics Design

Model 1756 Test Lead Kit

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Installation, Operation and Maintenance Manual

Trip circuit supervision relay. Type RXTCS

MC433 Stepper Motor Controller

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

MSL1000 Monitored Serial Link Interface Manual V1.01

Quick Connect. quick - simple - efficient.

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

PIKA Technical Bulletin #41. V-12 RAN Trunk Interface Implementation

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

38 Series - Relay interface modules A

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

38 Series - Relay interface modules A

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Model SPDT Relays

EXTERNAL DIMENSIONS AND PARTS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Datasheet of the Easy Servo Drive ES-D VDC, 8.2A Peak, Close-loop, No Tuning. Version

Telefon (+45) Telefax (+45) Installation and operating manual

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Allen-Bradley/Rockwell

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Application Note AN-SERV-006

YASKAWA AC Drive A1000

INTERFACING SECURITY SYSTEMS TO HOMEVISION

Speed Control Relays SX2

Transcription:

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC interface card (140-10269) is required, rather than the standard 120VAC input. Introduction: When using a 24VDC interface, the control terminal designations are different than on the standard GIF7 board for 120VAC input. This addendum is a cross-reference to avoid wiring errors due to the change in terminal designations. Warning: Hazardous voltage can cause severe injury or death. Lock all power sources feeding the drive and option card s wiring in the OFF position. Installation and wiring: The attached pages indicate the control terminals and wiring when using a 24VDC interface. N49 W13650 Campbell Dr www.magnetekmh.com Menomonee Falls, WI 53051 Phone: 262-783-3500 Fax: 262-783-3510 Page 1 of 6 Addendum 144-42471

Impulse G+/VG+ Series 3 Connection Diagram for 24 VDC Interface M1 SC SP 24 VDC SN M2 M3 M4 E(G) -15 vdc 20 ma Max. E(G) Replaces Page 3-5 of the Impulse G+/VG+ Series 3 Technical Manuals Page 2 of 6 Addendum 144-42471

Control Circuit board 2PCB DIP Switch S1 and Jumper CN15 S1 CN15 Figure 3-4: DIP Switch S1 and Jumper CN15 Location Dip Switch S1 DIP Switch S1 is described in this section. The functions of DIP switch S1 are shown in the table below. O Figure 3-5: DIP Switch S1 Function DIP Switch S1 Name Function Setting S1-1 RS-485 and RS-422 terminating resistance OFF: No terminating resistance ON: Terminating resistance of 110 Ohm Factory Default = OFF S1-2 Input method for analog input A2 OFF: 0 to 10Vdc or -10 to 10Vdc (internal resistance: 20K) ON: 4-20mA (internal resistance: 250 Ohm) Factory Default = OFF Jumper CN15 CH1 CH2 CN15 Jumper CN15 is described in this section. The jumper position of CH1 and CH2 determines the signal level of the multi-function analog output FM and AM, respectively. The functions and positions of CN15 are shown in the table below. V I Jumper CN15 Name Multi-function Analog Output Output Range CH1 FM V: 0 to 10V or -10V to +10V (default)i: 4 to 20mA CH2 AM V: 0 to 10V or -10V to +10V (default)i: 4 to 20mA Replaces Page 3-11 of the Impulse G+/VG+ Series 3 Technical Manuals Page 3 of 6 Addendum 144-42471

Sinking/Sourcing Mode The multi-function digital input terminal logic can be switched between sinking mode (0Vdc common) and sourcing mode (+24Vdc common) by using the terminals SN, SC, and SP. An external power supply can also be connected, providing more freedom in signal input methods. Sinking/Sourcing Mode and Input Signals Internal Power Supply Sinking Mode External Power Supply Sinking Mode External +24Vdc (Factory Default) Internal Power Supply Sourcing Mode External Power Supply Sourcing Mode External +24Vdc Page 4 of 6 Addendum 144-42471

Control Circuit Terminals The table below outlines the functions of the control circuit terminals when using 24 VDC interface instead of the standard GIF 7 interface board for 120 Volt input. Classification Terminal Signal Function Description Signal Level Sequence Input Signal Analog Input Signal S1 Forward run/stop Forward run when closed, stop when open 24 VDC, 8mA S2 Reverse run/stop Reverse run when closed, stop when open Photocoupler Isolation S3 Speed 2 S4 Speed 3 S5 Speed 4 S6 Speed 5 S7 External Fault S8 M-Speed Gain 1 SN Digital Input Photocoupler SC Digital Input Photocoupler SP Digital Input Supply 24 VDC +V +15V Power supply output -V -15V Power supply output A1 A2 A3 AC E(G) Master frequency reference Multi-function analog reference Multi-function analog input Common terminal for control circuit Connection to shield sheath of signal lead Multi-function contact inputs (H1-01 to H1-06) For analog command +15V power supply +15V (Allowable current 20 ma max.) For analog command -15V power supply -15V (Allowable current 20 ma max.) -10 to +10V/-100% to 100% 0 to +10V/0 to 100% 4 to 20 ma/0 to 100% -10 to +10V/-100% to 100% 0 to 10 V/0 to 100% -10 to +10V/-100% to +100% 0 to +10 V/0 to 100% Multi-function analog reference (H3-09) Auxiliary analog input (H3-05) 0V -10 to +10V (20k Ohm), 0 to +10V/(20k Ohm) 4 to 20mA (250 Ohm) -10 to +10V (20k Ohm), 0 to +10V/(20k Ohm) -10 to +10V (20k Ohm), 0 to +10V/(20k Ohm) Replaces Page 3-12 of the Impulse G+/VG+ Series 3 Technical Manuals Page 5 of 6 Addendum 144-42471

Classification Terminal Signal Function Description Signal Level Relay Output Signal Analog Output Signal Pulse I/O Signal RS-485/422 M1 M2 M3 M4 M5 M6 MA MB MC FM AC AM Brake output N.O. Contact N.O. Contact Fault annunciate Fault contact output (NO/NC contact) Multi-Function Analog Output 1 Common Multi-Function Analog Output 2 Multi-function output (H2-01 to H2-03) RP Pulse Input Pulse input frequency reference Terminals MA & MC N/O; closed at major faults Terminals MB & MC N/C open at major fault 0 to ± 10V Multi-function analog monitor (H4-01 to H4-03) 0 to ± 10V Multi-function analog monitor 2 (H4-04 to H4-06) Function set by H6-01 MP Pulse Monitor Pulse output frequency Function set by H6-06 R+ R- Modbus communication input S+ Modbus S- communication output IG Signal Common For 2-wire RS-485, jumper R+ and S+ and jumper R- and S- Dry contact Contact capacity: 250VAC, 1A or less 30VDC, 1A or less 0 to ±10V Max. ±5% 2mA or less 0 to ±10V Max. ±5% 2mA or less 0 to 32kHz (3k) +5% High level voltages 3.5 to 13.2 Low level voltages 0.0 to 0.8 Duty Cycle (on/off) 30% to 70% 0 to 32kHZ +5% output (load: 1.5k) Differntial input, PHC isolation Differntial output, PHC isolation Control Circuit Terminal Diagram Replaces Page 3-13 of the Impulse G+/VG+ Series 3 Technical Manuals Page 6 of 6 Addendum 144-42471