ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL



Similar documents
HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

OCS-S High Resolution Digital Crane Scale

Operating instructions Platform/floor scales

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

OCSM Series. High Resolution Digital Crane Scale. User Guide

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

High precision counting scale. Operation Manual. l RCZ-A Series

OCS-XZ-C Series User s Guide. OCS-XZ Series Electronic Crane Scale. User s Guide - 1 -

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

XP Series Balances Operation Manual

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Phoenix Body Fat Scale Manual

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

HIGH PRECISION WEIGHING SCALE. Operation Manual. l RCZ-B Series

BW-500 BED WEIGHER USER MANUAL

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

CountEasy Retail Advanced Configuration Manual

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

AR200. Refractometer User s Guide. Page 1

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

USB-500/600 Series Low-Cost Data Loggers and Accessories

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Model 349KLX Remote Display Digital Scale User Instructions

Digital Air Pressure Gauge Users Manual

USB-500 Series Low-Cost Data Loggers and Accessories

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

QLINK User Manual Stereo Audio Transmitter

User s Manual AURORA 1.2K/2.2K

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

FIREDEX Conventional Fire Panels

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

USER GUIDE. LED Light Meter. Model LT45

TC-9102 Series Surface Mount Temperature Controllers

Ron 3025 Crane Scale with 1"/25mm Display

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

SP1500 SERVICE SCALE PRINTER SP1500 SERVICE SCALE PRINTER SYSTEM ALL-IN-EFFICIENCY WITH HOBART SP1500 SERVICE SCALE SYSTEM SP1500 FEATURES

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 3000

Supplementary Certificate of Approval NMI S669

Microwave Meter. Instruction Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USB-500 Series Stand-Alone, Low-Cost Data Loggers

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;

Digital indicator 3011

TruPower-Portable-500W. Solar Starter kit

Instruction Manual FL

Installation and Operating Instructions (for chargers shown below)

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

Installation and Operating Instructions (for chargers shown below)

My Weigh Ultraship Series User Manual

User Manual. Before installation and use, please read the user manual carefully.

AC-115 Compact Networked Single Door Controller. Installation and User Manual

P10 - Standalone Access Controller and Reader

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Virtual Measurements & Control. Flip/Flop Filler

BLOOD COLLECTION MIXER

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Quick start guide smart.power smart.power smart.power

Parts List. Navigation

Operation of the 500 computer. Menu. Meaning of the different knobs. Type K. Esc

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

STERILIZERS, LABORATORY DRYING OVENS

HT580 User Reference Guide. Version 1.0

13 Watt PORTABLE SOLAR POWER KIT

Handheld force display AE 703

TECHANGLE November 30, 2005 TECHNICAL PAGE

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Hygro-Thermometer + InfraRed Thermometer Model RH101

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Instruction Manual Crane Scales PCE-HS Series

Intelligent GSM Auto-Dial Alarm System

LC/LCD ranges level controllers

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

UT202A Operating Manual. Contents

User Guide. Temperature and Humidity Datalogger. Model 42280

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

Back-UPS Pro 1300/1500 Installation and Operation

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

INDICATOR LAMPS & LED REPLACEMENT LAMPS

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Instruction Manual Temp 4/5/6 Temperature Meter Series

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

User checks and maintenance of laboratory balances

TENSIONMETER ** code 183_LNRSTW **

User Operation Manual

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Transcription:

ACS- SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

Thank you for choosing our ACS-3S / NEW SU single/double side display electronic waterproof weighing/counting scale. The new SU model is made of plastic and the 3S is made from stainless steel. The scale is manufactured with advanced computer-controlled techniques. It exhibits hi accuracy weighing performance, convenient for carrying but also being cheap in price. It is sturdy and durable, and widely used in not only retail stores and weighing of ration packing of commodities, but also in high humidity surroundings because of its waterproof function. Ⅰ. MAIN TECHNICAL INDEX 1. Basic Data ITEM TYPE Max. Capacity Min. Capacity Division size (Option 1) Division size (Option 2) Division size (Option 3) Max. Tare Accuracy SU -1.5 SU -3 SU -6 SU -15 SU -30 1.5kg 3kg 6kg 15kg 30kg 20e 0.5g 1g 2g 5g 10g 0.2g 0.5g 1g 2g 5g 0.1g 0.2g 0.5g 1g 2g 100% Max. Cap. III Pan Size SU 19 23 cm 2. Working Temperature : -5 to +35 3. Storage Temperature: -25 to +50 4. Power: 6V4Ah rechargeable battery. 5. Net Weight: 3.6kg/pc 6. Dimension: 4pcs/ctn, 58x35x30cm

Ⅱ. KEYBOARD AND CHARACTER PROMPT 1. Keyboard ON/ ZERO Turns the scale on and zero. TARE Tare key. OFF Power off. SET 0~9 Set up / Configuration key. Set parameter and input configuration. 2. Error Messages dc x.xx Means the voltage of battery is x.xx V. ------ (with buzzer sounding) Weight is over 100% full scale + 9e scale is overloaded. Reduce the weight on the scale. -AdC- (with buzzer sounding) A/D unstable. Possible load cell fault. -BATLo- Low battery - charge immediately. C_End Err-0 Charging complete. Overload zero of load cell. Please re-adjust or change load cell.

III. OPERATION GUIDE 1. Preparation Level the scale and make sure the pan is horizontal by adjusting the base feet, and using the built-in spirit level for accuracy. 2. Turn on Press the [ON/ZERO] key. The buzzer will sound and the display will show the battery voltage level, followed by the machine version number, and then a countdown from 9 to 0. The machine will then show 0 and the scale is ready to use. 2.1 Turn off Turn the machine off by holding down the [OFF] key. 2.2 Auto-off (Optional) After 10 minutes of inactivity, the machine will automatically turn itself off. 2.3 Low voltage auto-off When the battery voltage falls below 5.6V, the machine will power-off. 3. Zero When the weight displayed is lower than 4% of maximum capacity, the [ON/ZERO] key, will, when pressed, zero the display. 4. Weighing Put weight on pan. 5. Tare weighing Place container or item on scale and press the [TARE] key. The display will then tare off and will show 0, and the tare LED light will be on. To clear the tare, press the [TARE] key, and the LED light will turn off. 6. Save power function After 40 seconds of inactivity, the machine will switch to auto power save and the display will show 0. Put a weight on the scale to start weighing again. 7. Battery indication Battery lamp: High means voltage higher than 6.3V, Mid means voltage between 6V and 6.3V, Low means voltage lower than 6V.

8. Charge The power is supplied by an internal rechargeable lead acid battery (6V/4Ah). When the display shows -batlo-, please connect the machine to a mains supply and charge immediately. The time of full charging is 12 hours. 9. Set parameters Press [SET/0~9] key for 3 seconds. The display will now enter into the parameter menu. Press [SET/0~9] continuously to scroll through each parameter, as follows : range (set limit) UnItS (choose unit) A- OFF (choose auto power off) FILt (set display mode) Zero (set auto zero) buzzer (set buzzer) d (choose division) On-rA (choose range of power on) d-dp (choose single or dual display) 9.1 Set range of auto-zero: 9.1.1 Range (check weighing) Press the [SET] key for 3 seconds. The display shows range. Press the [TARE] key. The display shows off. Press the [SET] key. The display shows on. Press the [TARE] key. The display shows 00000, and the under LED will flash. Enter the lower limit of the product, eg, 995. Press the [TARE] key to move right, and the [ZERO] key to increment up. After entering the last digit, the display shows 00000, and the over LED will flash. Enter the over limit of the product, eg, 1005. After entering the last digit, the display will show 0. Place the product on the scale. When the scale displays a stable weight, the under accept over LED will be illuminated. To return to normal weighing, press [SET] for 3 seconds. The display shows range. Press [SET] key until units is displayed. Press the [TARE] key. Press the [SET] key until g is displayed. Press the [TARE] key. The scale is now in normal weighing. Caution:When the display is not stable, no Led lamp will be on.

9.2 Changing weighing units 9.2.1 When units is displayed, press [TARE], then press [SET/0~9] to choose, then press [TARE] to confirm and exit. Unit: H9(kg), 9(g),Lb,oz,pcs(counting). (Imperial units may not be chosen when calibrating). 9.2.2 Pcs Counting: Press [SET] key for 3 seconds. The display will show Range. Press [SET] key until units is displayed. Press the [TARE] key. The display shows g. Press the [SET] key until pcs. Press the [TARE] key. The pcs LED will be on. Put the sample quantity onto the scale. Press and hold the [ZERO] key. The display shows 00000, and the pcs LED will be flashing. Press the [TARE] key. The display shows 00000 with the left hand digit flashing. Use the [TARE] key to move right and the [ZERO] key to increment up. Enter the sample quantity, eg, 200. Press [TARE]. The display will now be in count mode and show the sample quantity measured, eg, 200. To return to normal weighing mode, press [SET] for 3 seconds until units is displayed. Press the [TARE] key. The display shows pcs. Press the [SET] key until g is displayed. Press the [TARE] key. 9.3 A-oFF(choose auto power off) When menu displays A-oFF,press [TARE] to enter,then press [SET/0~9] to choose n or y. n is auto power off, y is auto power off after 10 minutes of inactivity. 9.4 Change display filtering When the display shows FILtX (FILt1 means one step to display, FILt2 means 3-4 steps to display, FILt3 means 6-8 steps to display, FILt4 is the fastest filter setting). Press [SET/0~9] to change, press [TARE] to confirm and exit. 9.5 Set range of auto-zero: When zero is displayed, press [TARE]. The display will show zero x.x(x.x is the range:0.5d,1d,1.5d,2d,2.5d,3d,3.5d,4d,4.5d,5d. d is the division value when n=3000). Press [SET/0~9] to choose and [TARE] to confirm. 9.6 buzzer (set buzzer sound on or off) When menu displays buzzer,press [TARE] to enter,press [SET/0~9] to choose on or off, and then press [TARE] to confirm.

9.7 Change division size When menu displays d,press [TARE] to enter,and then press [SET/0~9] to choose division increment size. 9.8 On-rA (choose range of power on) When menu displays On-rA,press [TARE] to enter,press [SET/0~9] to choose 20 or 100, 20 is 20% max. capacity, 100 is 100% capacity. Press [TARE] to confirm. 9.9 d-dp (choose single or dual display) When menu displays d-dp,press [TARE] to enter,press [SET/0~9] to choose n or y, n is single display, y is dual display, Press [TARE] to confirm. 10.0 Power save LED lighting On powering on, press and hold [zero/on] key. The display shows LC-, press [SET/0~9] to choose LU-1 or LU-2, LU-1 is saving mode (recommended). Press [TARE] to confirm. 11.0 Super SS Calibration 1. Remove calibration cover under scale and turn on the calibration switch. 2. Switch on the scale and while the display counts down, press and hold the [TARE] key. The display will show CAL and then go into zero counts mode. With nothing on the scale the display should show 0 ; if not press the [ZERO] key. 3. When the display shows 0 press the [TARE] key 4. The display will then keep flashing the weight to be used for calibration, eg. 6000g 5. Put on the correct weight, eg 6000g, and press the [TARE] key 6. The display will show CAL END and then return to normal weighing 7. Switch the calibration switch back to off position and replace the calibration cover under the scale 8. Switch the scale back on and check with test weights

IV. SCALE MAINTENANCE 1. Take care not to overload the scale. Do not place heavy things on the scale violently. The damage for overloading is not within the range of the guarantee. 2. Do not use sharp objects to operate the keypad. If the rubber is damaged it will influence the performance of the waterproof seal. 3. Keep the scale clean in order to maintain performance. 4. There is a lead seal on the bottom of the scale. Users are not allowed to remove the seal. If the seal is damaged the guarantee is void. 5. a. You must charge the battery at least once every 3 months during periods of scale inactivity. b. Please take care to correctly connect the battery terminals (ie, black to black, red to red). c. If the battery life seems short, even after frequent charging, please replace with a new battery.