UPSentry Smart 2000. User s Manual. Shutdown Management Software. for Mac OS X 10.2



Similar documents
UPSentry Smart User s Manual. Shutdown Management Software. for Mac OS X 10.1

Belkin Bulldog Plus. Shutdown Management Software. for Mac OS X 10.2

Sentry Bulldog Shutdown Management Software (For UNIX Series)

SentryPlus. Shutdown Management Software for Windows. User s Manual

Network Management Card. User Manual

Using the UPSMON-Plus Monitoring Software

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

Belkin Bulldog Plus. Shutdown Management Software for Windows. User s Manual

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

UPS Monitoring and Management Software

Bulletin 1609 UPS Management Software

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

Changing Your Cameleon Server IP

Belkin. Automatic Power Management Software. User s Manual

PowerPanel Personal Edition User Manual. User Manual. PowerPanel Personal Edition. Rev /02/24

LOREX CLIENT Remote Software 4.0

User manual Borri Power Guardian

PowerPanel Personal Edition User Manual. User Manual. PowerPanel Personal Edition. Rev /12/2

Belkin Bulldog Plus Shutdown Management Software for Windows

UPS Monitoring Software. User manual Borri Power Guardian

UPSMON PRO Linux --- User Manual

User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

User Manual WatchPower

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower User Manual

REMOTE AGENT USER S MANUAL

Trend Micro KASEYA INTEGRATION GUIDE

User s Manual Network Management Card

Winpower. User Manual.

NetIQ. How to guides: AppManager v7.04 Initial Setup for a trial. Haf Saba Attachmate NetIQ. Prepared by. Haf Saba. Senior Technical Consultant

Control Software for UPS with LAN-Ethernet Interface

How To Set Up Dataprotect

User s Manual. Management Software for Inverter

Deploying Windows Streaming Media Servers NLB Cluster and metasan

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

ren Winpower User Manual

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

This manual provides information and instructions for Mac SharePoint Users at Fermilab. Using Sharepoint from a Mac: Terminal Server Instructions

Attix5 Pro Server Edition

Enterprise Historian 3BUF D1 Version 3.2/1 Hot Fix 1 for Patch 4 Release Notes

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

The following is a preview of an Nfina storage system with an embedded LSI RAID controller using MegaRAID Storage Manager software.

CLC Bioinformatics Database

ivms-4200 Client Software Quick Start Guide V1.02

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Interacting with Users

- 1 - SmartStor Cloud Web Admin Manual

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

The following was taken directly from the ARD (Apple Remote Desktop) operator s manual:

Virtual Office Remote Installation Guide

You can find the installer for the +Cloud Application on your SanDisk flash drive.

PowerPanel Business Edition USER MANUAL

Thin Client Manager. Table of Contents. 1-10ZiG Manager. 2 - Thin Client Management. 3 - Remote client configurations. 1 of 16

mypro Installation and Handling Manual Version: 7

File Manager Pro User Guide. Version 3.0

Winpower. User Manual. To find user manual in other languages and software updates, please visit for more information

SSD Guru. Installation and User Guide. Software Version 1.4

Introduction to Mac OS X

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

Pivotal CRM AvaTax Connector Installation

Remote Desktop Services User's Guide

EBSCO MEDIA FILE TRANSFER SOFTWARE INSTALLATION INSTRUCTIONS

Monitoring Network DMN

UPSentry Smart 2000 Shutdown Management Software for Windows

You can t hear others

Moxa Device Manager 2.0 User s Guide

SSL-Manager (SNMP-SSL Management Software)

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

Deep Freeze Enterprise - Advanced Maintenance & Autologon

Driver Installation (USB 2.0) and Software configuration manuals for Sopro Imaging, EagleSoft, and Dentrix Image 4.5

Citrix for Mac Installation

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

UPS MONITORING SOFTWARE USER MANUAL

User's Reference Guide for PowerAlert UPS Management Software Version 10.2 for Windows

Introduction. There are several bits of information that must be moved:

Configuring Virtual Blades

Hi-Speed USB 2.0 Flash Disk. User s Manual

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

IP Surveillance System. User s manual

Cloud Attached Storage 3.1 EA

Online Help StruxureWare Data Center Expert

Imation Clip USB 2.0 Flash Drive. Imation Drive Manager Software. User s Manual

NVMS User Manual

Using RAID Admin and Disk Utility

Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting

Cornerstone* New Activation Key Instructions Cornerstone Module Change Using Files on the Server to Reinstall the Software

How To Sync Google Drive On A Mac Computer With A Gmail Account On A Gcd (For A Student) On A Pc Or Mac Or Mac (For An Older Person) On An Ipad Or Ipad (For Older People) On

System update procedure for Kurio 7 (For build number above 110)

Software User Manual. Table of Contents

Monitoring Oracle Enterprise Performance Management System Release Deployments from Oracle Enterprise Manager 12c

Ambient Temperature In Range Probe X

User and Installation Manual

CONFIGURING SQL SERVER FOR METRIX

POWERED BY BLUE EARTH

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

Introduction to OS X (10.4)

Transcription:

UPSentry Smart 2000 Shutdown Management Software for Mac OS X 10.2 User s Manual

Table of Contents Introduction...3 Installing/Removing UPSentry Smart 2000...4 User Interface: UPSentry...5 System Menu...6 View Menu...9 Control Menu... 10

Introduction The aim of UPSentry Smart 2000 is to monitor and control your UPS and take care the power events for you. UPSentry Smart 2000 has the ability to automatically shutdown your computer protected by an UPS when an extended power outage is occurred, for example. UPSentry Smart 2000 provides the most useful information about the UPS. It is an easy-to-use program that furnishes you with all you need. The UPSentry Smart 2000 consists of two main components, The first is the UPS daemon which runs as a background process. It communicates with the UPS and the user interface module, and when necessary, shuts down the Mac OS. The second component is the user interface module which communicates to a local UPS daemon. 3

Installing/Removing UPSentry Smart 2000 System Requirements: UPSentry Smart 2000 requires Mac OS X version 10.2 or higher. Installing UPSentry Smart 2000: 1. Copy the UPSentry.tar to your Mac computer. 2. Double click the UPSentry.tar on Aqua interface or type tar xvf UPSentry.tar in the Terminal mode to extract it to the UPSentry_3 directory. 3. There is an installation file UPSentry.pkg in the UPSentry _3 directory, execute it to begin the installation procedure. Note that you need to restart the computer to load the UPS daemon after installation. The UPSentry Smart 2000 software is comprised of two modules: o A UPS Monitoring Module(upsd), which runs as a background process(daemon) and communicates to the UPS. o A User Interface Module, UPSentry for Aqua Interface, which enables you to configure UPSentry Smart 2000 through the drop down menus and dialog boxes. It also allows you to monitor the UPS through the Main Screen. 4. After installation, UPSentry Smart 2000 program files will be placed in the directory /Applications/UPSentry. We suggest you drag the UPSentry icon to the Dock. 5. Shutdown and reboot your system to start the UPSentry Smart 2000 daemon. Removing UPSentry Smart 2000: 1. A shell script file uninstall.command is also provided in UPSentry_3 directory that allows an administrator to stop all processes and remove all files associated with UPSentry Smart 2000. 4

User Interface: UPSentry The UPSentry Smart 2000 Main Screen is what you will see and work with. The user interface module is comprised of the Main Screen and System, View and Control menu options. It gathers real-time data such as input/output voltage, UPS events and allows you to perform self-test, prearrange the OS shutdown delay time, notification interval and schedule server shutdowns. 5

System Menu The system menu allows you to configure the UPSentry Smart 2000 parameters. You select the System menu from Main Menu bar then a drop down menu appears offering you the following menu options: UPS Property a. Load Warning Level: You can set a load warning alarm by specify its value. b. Load Critical Level: You can set a load critical alarm by specify its value. c. Battery Low Warning: Allow you to adjust the battery low level. If the measured battery level from UPS is lower than the assigned value we ll treat it as a battery low event. d. Last Battery Replacement Date: Record last battery replacement date. e. Next Replacement Date: The date of next battery replacement. Log Management Allow UPSentry Smart 2000 to preserve less than the assigned entries of event log. Schedule 6

This function allows you to shutdown your Mac computer and UPS, restart the UPS and test the UPS by the specified time. Setting is based on a specified day, daily, weekly or monthly and up to a period of 2 years. Event Actions 7

Close This menu option allows you to adjust the actions taken by UPSentry Smart 2000 during the following power events: a. Power Fail: This option allows you to adjust the OS and UPS shutdown delay time taken by UPSentry Smart 2000 during a power failure, shutdown will start the specified number of minutes after a power failure. b. Battery Low: This option allows you to adjust the OS and UPS shutdown delay time taken by UPSentry Smart 2000 during a battery low event, shutdown will start the specified number of minutes after a battery low. c. Schedule Shutdown: This option allows you to adjust the OS and UPS shutdown delay time taken by UPSentry Smart 2000 when it reaches the schedule time. d. Enable Execute File: Allow you to run a shell script or application before computer shutdown. Selecting this option causes you to exit the UPSentry Smart 2000. The upsd continues to monitor the UPS. 8

View Menu Event Log This menu offers you the possibility of viewing past events. UPSentry Smart 2000 logs the power events and system operating events for users inspection. This screen lists the most recently logged events by date and time of occurrence. By dragging the scroll bar to view the entire log. 9

Control Menu Shutdown Now Let you shutdown your Mac OS, UPS or restart UPS on the restart time you have set in Schedule. Cancel Shutdown Cancel the ongoing shutdown procedure. UPS Audible Alarm On Enable the UPS buzzer. UPS Audible Alarm Off Mute the UPS buzzer alarm. 10 Seconds Test The UPS switches to backup mode and its output power is supplied by battery in 10 seconds.. Deep Battery Test The UPS switches to backup mode and its output power is supplied by battery until battery low. Cancel Test This menu allows you to stop testing of UPS immediately. 10

Voltage Sensitivity Adjust the UPS voltage sensitivity. Transfer Voltage Change the low transfer voltage and high transfer voltage. You can use this function to let your UPS suit local power environment. a. Low Transfer Voltage: If the utility power voltage is lower than the assigned value, the UPS will switch to backup. The output power is supplied from battery. b. High Transfer Voltage: If the utility power voltage is higher than the assigned value, the UPS will switch to backup. The output power is supplied from battery. 11