Condensate water pump with neutralisation system



Similar documents
Conlift1, Conlift2, Conlift2 ph+

ECOCIAT. Domestic hot water heat recovery unit

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

UNITOR VACUUM cleaners

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

MANTA Piston Distributor for Oil and Fluid Grease

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Evaluate, Clean, and Tune Guidance

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

york air-conditioning products Residential & VRF News 2015

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Electric Flow Boiler

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

CADB and CADT-D / DI / DC Series

Top Technology for Industry, Agriculture, Business and Communities

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

MEMBRANE VACUUM MINI PUMPS

Adsorption air dryers ADS 1 215

Laing industrial pumps

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Failure code manual. content

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Why use Tigerloop in fuel heating systems?

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Kompressoren. Adsorption Dryer AD

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Midland Combustion Electric Line Heaters with Integral Panels

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

Factory owners must ensure the boiler is:

The natural ombination

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Cooking at the Speed of light!

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Diesel Generating Set

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Hydraulic Trouble Shooting

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

AIR DEHUMIDIFYING Condensation drying for industry and trade

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Vacuum drying oven for non-flammable solvents

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Hydraulic Control Solutions

For installation guide see reverse of book

Please also see 10 golden rules for correct Saniflo installation on

AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave

HEAVY DUTY STORAGE GAS


1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Medical Air Systems: Scroll

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

User's Instructions. Alpha HE CB25/33 and HE SY25

Oil and Coolant Circulating Heating System. Model - OCSM

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Guidelines for Preparing for a Temporary Steam Plant

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

We have been working in an ideal climate for thirty years.

The Best Selling Domestic Stainless Steel Oil Boiler

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Flex separation systems, S-separators

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Session 2: Hot Water Supply

Split units TH with hermetic compressors

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

AFE424 SERVICE PARTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

AIR-CONDITIONER SPLIT TYPE

CRAC Precision climate control units for data centres

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Oil - kerosene burners

Radial piston pumps type R and RG

Cooling kw Heating kw

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

Transcription:

Pumps for fuel oil and gas boiler Condensate water pump with neutralisation system

SK9E/FP8E débit obtenu (l/h) caractéristriques selon la fréquence réglée performances avec une hauteur d aspiration de 3 m 18 16 position 4-5Hz position 3-25Hz position 2-16.5Hz 14 position 1-12.5Hz 12 1 8 6 4 2 2 4 6 8 1 12 14 hauteur de refoulement (m) Pressure pump system with electromagnetic piston pump, four different flow rates adjustable, self regulating pressure control, pressure relief valve, safety oil chamber, bleed and drain valve, built-in suction filter, completely wired with earthing contact-type plug and mounting strip. Pipe connection: ID 8mm. The unit can be used for different applications by changing the position of a jumper on the pump's PCB. Application : 1. Delivered in version SK9E as central oil distribution system with one or more oil ovens to be used as a permanent operating pump during the heating season (not usable for full-year operation) 2. Version FP8E, feeding pump for oil burners in on-line systems or automatic oil evaporation burners (e.g.for tiled stoves) Advantages : - Optimal regulation of the flow rate according to the consumption (from 5 to 1KW) - Reduction of the wear - Very great lifetime in synchronized mode - One-line system, no return to the tank - Reduce noise level - Anti return valve included Dimensions : 18 x 2 x 98 mm Weight : 18 g Power : 25 VA Voltage : 23V/5Hz Jumper for selection of the application Jumper for regulation of the flow rate

KD1 Pressure storage system with electromagnetic piston pump, control and safety device depending on the delivery length, pressure gauge, built-in suction filter. Pipe connections: ID 8mm, completely wired with earthing contact-type and mounting strip. Built-in safety oil pan with separate detection. Application : Central oil distribution system up to 12 users, suitable for full-year operation (e.g.feeding pump for oil burners in one-line systems). Advantages : - Optimum intermittent operation - Lifetime prolonged - Reduce noise level - One-line system, no return to the tank - Anti return valve included - Anti-leak included Dimensions : 28 x19 x17 mm Weight : 415 g Power : 4 VA Voltage : 23V/5Hz

SP32 1 débit de remplissage (l/h) 3 25 2 15 1 5. 1. 2. 3. 4. 5. 6. 7. hauteur d aspiration (m) longueur de conduite 1 m 2 m 3 m 4 m Suction pump system with electromagnetic piston pump, floatcontrol- and safety device, built-in suction filter, check valve, 1,6l oil storage tank, LCD display with permanent function-control feedback, built-in safety oil pan with separate detection, thermical safety detection. Pipe connection : ID 8mm, completely wired with earthing contact type plug. Application : Ecological system used for fan burner up to 8kW at 7m suction height and for oil/tiled ovens. Foreseen for one-line system. Advantages : - Operating cycle with 1% security - Operating cycle and eventually disturbed described on the LCD display. - Safety oil pan with separate detection - Protect again dry run - Pump will stop if oil tank is empty, if the pipes are damaged and if the ambient temperature is too high.. Dimensions : 25x217x168 mm Weight : 2 g Power : 4 VA Volatge : 23V/5Hz

SP32 2-4 et SP32 2-8 Suction pump system with electromagnetic pump, float, control and safety device, built-in suction filter, 7.3l oil storage tank, built-in safety oil pan with separate detection, LCD display with permanent function control feedback with anti-syphoning protection valve, alternatively in mechanical version SP32 M or electrical version SP32 E (is driven through the oil burner). Pipes connection: ID 6 for the 4l version (SP32 2-4) and ID 8 for the 8l version (SP32 2-8). Completely wired with earthing contact-type plug. 9 8 7 6 5 4 3 2 1 longueur de conduite 1 m 2 m 3 m 4 m. 1. 2. 3. 4. 5. 6. 7. Application : Full-automatic suction pump system for feeding oils burners up to max.5l/h nozzle capacity. Foreseen only for one-line systems. Version SP32 2-4R can be used as central oil distribution system with one or more oil ovens. Advantages : - Storage of 7.3l of heating oil - Operating cycle and eventually disturbed described on the LCD display - Anti return valve included and choice of electrical or mechanical anti-syphoning. - Safety oil pan with separate detection - Protect again dry run - Pump will stop if oil tank is empty, if the pipes are damaged and if the ambient temperature is too high.. - The big quantity of oil stocked in the pump (7.3l) allow to this oil to take the ambient temperature. Thanks to this fact, the stability and viscosity is all time the same and facilitate the regulation of the burner flame. Technical datas of the SP32 2-4: Dimensions : 315x38x325 mm Weight : 65 g Power : 4 VA Voltage : 23V/5Hz Technical datas of the SP32 2-8: Dimensions : 315x38x325 mm Weight : 7 g Power : 8 VA Voltage : 23V/5Hz 7 6 5 4 3 2 1 hauteur d aspiration (m). 1. 2. 3. 4. 5. 6. 7. hauteur d aspiration (m) longueur de conduite 1 m 2 m 3 m 4 m

SP32 2-4-D/R 7 6 5 4 3 2 débit pompe aspirante longueur de conduite 1 m 2 m 3 m 4 m Same system like the SP32-4, but built with 2 piston pumps : 1 for the suction and 1 for the pressure. Foreseen as an intermediate station for suction and pressure operation in case of long conduits between the tank and the boiler. This system can be built everywhere on the conduits 1 1 2 3 4 5 6 7 8 Same safety devices as the SP32 range. 45 4 35 3 25 2 15 1 5 hauteur d aspiration (m) débit pompe refoulante 2 4 6 8 1 12 14 16 18 hauteur de refoulement (m) Dimensions : 315x38x325 mm Weight : 7 g Power : 8 VA Voltage : 23V/5Hz

SP32 3-2 High performance-internal gear pump (gap compensated), motor, float-, control- and safety. Device, built-in suction filter, 7.3l storage tank, built-in safety oil pan with separate electrical detection, LCD display with permanent function-control feedback, vacuum gauge, two separate feeding lines whether with electrical or mechanical or without antisyphoning-protection-valves, all pipe connectors are located above the security pan, pipe connections for ID1mm pipe, separate vent connection, completely wired with earthing contact-type plug. 22 21 2 19 18 17 16 2 4 6 8 9.5 Application: Full automatic suction pump system for supplying one or several oil burners up to 18l/h nozzle capacity (see performance diagram), only for one-line systems. Dimensions : 635x46x245 mm Weight : 2 Kg Power : 15 VA Voltage : 23V/5Hz hauteur d aspiration (m)

DSA4 7 6 5 4 3 2 1 aspiration 1 m aspiration 2.5 m aspiration 4 m.5 1. 1.5 2. 2.5 3. The system consists of a fuel oil delivery pump system and a gas pressure accumulator, completely installed on a mounting panel to be fixed on the wall. The equipment is completely installed, wired with earthing contacttype plug and is provided with ID6mm pipe connections for suction-, feed- and return line. In case of line break the unit be automatically stopped by a security pressure switch (<.6bar). If the pressure fall under 1.5bar a safety device will stop the pump. pression (bar) Tubes: calculer.9 bar perdu par 1 m horizontalement ou 1 m verticalement Applications : Central oil distribution system for housing estates with several oil ovens (> 12 users) suitable for full-year operation. Automatic distribution of oil burners in one-line systems up to 35kW. Technicalk datas : Dimensions : 48x34x21 mm Weight : 9 g Power : 6 VA Voltage : 23V/5Hz

EE4 Condensat water pump with neutralisation system The centrifugal condensate pump EE4 is designed to automatically remove the liquid from an oil or gas burner. Not equipped with granulate for the neutralisation of the condensate water. This pump is made from a tough ABS plastic body so it will resist corrosion and impact. Advantages: - Silent running centrifugal pump with 1,5m power cord - Ball bearing drive shaft - Max. medium temperature : 75ºC - Check valve to prevent back-flow of liquid into the unit - Overflow safety alarm switch - The most compact system and silent pumps on the market Dimensions : 185x85x1 mm Weight : 16 g Voltage : 23V/5-6Hz Power : 65 VA Tank capacity :.5l Alarm switch : 24V, 6A (NO) ohmic load 35 28 22 1 1 2 3 4 hauteur de refoulement (m)

EKF15 T Condensat water pump with neutralisation system 16 12 Removal condensate system without neutralisation granulate. This pump is foreseen for little application until 25kW and have the advantage to remove the condensate until 14m vertical delivery height, thank to the built-in electromagnetic pump. 8 4 2 4 6 8 1 hauteur de refoulement (m) Advantages : - High quality electromagnetic piston pump - Temporized safety device in order to reduce the time running of the pump - Low tension in order to reduce the wear of the contacts - Overflow safety device - Filter and non-return valve included - Wired (1m) with electrical plug Dimensions : 244x174x144 mm Weight : 16 g Voltage : 23V/5Hz Power : 4 VA Tank capacity : 2 l Alarm switch : 24V, 1A ohmic load

EKF15-25NB Condensat water pump with neutralisation system Removal condensate system with neutralisation process. Completely adapted for applications until 5kW and with a supplementary tank NB5 with granulate can be used for installation until 1kW. Thank to his low noise level the pump can be installed in the house (domestically use) or in the heating room near the boiler. Like the EKF15-T the system have a built-in electromagnetic piston pump which can remove the condensate until 14m vertical delivery height 16 12 8 4 Adavantages : - Same as the EKF15-T - With the tank NB5 in serial, the system can remove condensate and neutralize installation until 1kW Dimensions : 244x174x261 mm Weight : 32 g (with granulates) Voltage : 23V/5Hz Power : 4 VA Tank capacity : 6 l Alarm switch : 24V, 1A ohmic load 2 4 6 8 1 hauteur de refoulement (m)

EKF17-6NB Condensat water pump with neutralisation system Same system as the EKF15-25NB, but for installation until 6 KW. Thank to the built-in electromagnetic piston pump, the system can remove the condensate until 16m vertical delivery height. 12 Adavantages : - Efficient and high performances - Complet and economical system - The tank can be delivered without the pump, to be used as a neutralisation system. - Easy maintenance - Overflow safety device - Wired (1m) with electrical plug Dimensions : 655x4x245 mm Weight : 31 Kg (with granulates) Voltage : 23V/5Hz Power : 45 VA Alarm switch : 24V, 8A ohmic load As spare parts for all the neutralisation system you can order bags of neutralisation granulates from 1Kg and 25 Kg. 11 1 9 8 2 4 6 8 1 hauteur de refoulement (m)