E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL



Similar documents
Cylindrical Proximity Sensor

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

How To Read A Pipe From A Sensor

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Capacitive Prox E2K-X

Inductive Proximity Sensors

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Cylindrical Proximity Sensor

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Absolute Rotary Encoder E6CP

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Proximity Sensor with All-stainless Housing

Inductive sensor NI10-M18-Y1X-H1141

Color Mark Sensor with Red or Green LED E3S-VS

How To Power A Schen

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SPST-NO SPDT DPST-NO DPDT

Electronic Pressure Switch EDS 300

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Cross-beam scanning system to detect slim objects. 100 mm in

Thread length (overall length) 27 (40) 49 (62) 27 (43) 49 (65) 27 (43) 49 (65) 27 (39) 49 (61) 27 (40) 49 (62) 27 (43) 49 (65) 27 (43) 49 (65)

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Small-diameter Proximity Sensor

NX safety stand-alone

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Liquid Leakage Sensor Amplifier

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Solid-State Timer H3G

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Model Number Structure

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Inductive sensors. Compact, fast, reliable. Edition 2013

Surface Mounting Relay

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Technical Data. Dimensions

SPST-NO SPDT DPST-NO DPDT

Model Number Structure

Preset Counter signo 721

38 Series - Relay interface modules A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

38 Series - Relay interface modules A

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

CQM1-SF200/CS1W-SF200

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Cylindrical Proximity Sensor E2A. Ordering Information. DC 3-wire models (NO + NC: DC 4-wire) *2

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Incremental Rotary Encoder E6B2

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Magnetic proximity switches

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

W150: Miniature photoelectric switch series with completely integrated electronics

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Anelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma.

Adjustment functions for both span and shift have been incorporated

Series 8146/5-V37 and Series 8150/5-V37

Universal Voltage Terminal Photoelectric E3JM

Smart DeviceNet Remote I/O Terminals

Turbine Flow Sensor Series VTR

Speed sensor MiniCoder GEL 247

U-shaped Micro Photoelectric Sensor

How To Use A Flowmeter

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Electronic Pressure Switch EDS 3000

RY2 miniature industrial relays

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

Digital display DA 48

photoelectric highlights

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

intelligent solutions

General-purpose Relay

E2A Single Sensing Distance

Transcription:

High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information Cable types Brass housing Diameter Length Mounting Ø 6,5 M8 Sensing Distance Output NPN / NO NPN / NC PNP / NO PNP / NC 30 mm Shielded 1,5 mm -C1R5E1 2M -C1R5E2 2M -C1R5F1 2M -C1R5F2 2M 32 mm Non-shielded 2,0 mm -C2ME1 2M -C2ME2 2M -C2MF1 2M -C2MF2 2M 45 mm Shielded 1,5 mm -C1R5E1-L 2M -C1R5E2-L 2M -C1R5F1-L 2M -C1R5F2-L 2M 47 mm Non-shielded 2,0 mm -C2ME1-L 2M -C2ME2-L 2M -C2MF1-L 2M -C2MF2-L 2M 30 mm Shielded 1,5 mm -X1R5E1 2M -X1R5E2 2M -X1R5F1 2M -X1R5F2 2M 32 mm Non-shielded 2,0 mm -X2ME1 2M -X2ME2 2M -X2MF1 2M -X2MF2 2M 45 mm Shielded 1,5 mm -X1R5E1-L 2M -X1R5E2-L 2M -X1R5F1-L 2M -X1R5F2-L 2M 47 mm Non-shielded 2,0 mm -X2ME1-L 2M -X2ME2-L 2M -X2MF1-L 2M -X2MF2-L 2M Stainless steel housing Diameter Length Mounting Ø 6,5 M8 Plug types Brass housing Sensing Distance Output NPN / NO NPN / NC PNP / NO PNP / NC 30 mm Shielded 2,0 mm -C2E1-DS 2M -C2E2-DS 2M -C2F1-DS 2M -C2F2-DS 2M 45 mm Shielded 2,0 mm -C2E1-DSL 2M -C2E2-DSL 2M -C2F1-DSL 2M -C2F2-DSL 2M 30 mm Shielded 2,0 mm -X2E1-DS 2M -X2E2-DS 2M -X2F1-DS 2M -X2F2-DS 2M 45 mm Shielded 2,0 mm -X2E1-DSL 2M -X2E2-DSL 2M -X2F1-DSL 2M -X2F2-DSL 2M Diameter Length Mounting Ø 6,5 / Plug M8 M8 / Plug M8 M8 / Plug M12 Sensing Distance Output NPN / NO NPN / NC PNP / NO PNP / NC 45 mm Shielded 1,5 mm -C1R5E1-M3 -C1R5E2-M3 -C1R5F1-M3 -C1R5F2-M3 47 mm Non-shielded 2,0 mm -C2ME1-M3 -C2ME2-M3 -C2MF1-M3 -C2MF2-M3 54 mm Shielded 1,5 mm -C1R5E1-M3L -C1R5E2-M3L -C1R5F1-M3L -C1R5F2-M3L 56 mm Non-shielded 2,0 mm -C2ME1-M3L -C2ME2-M3L -C2MF1-M3L -C2MF2-M3L 45 mm Shielded 1,5 mm -X1R5E1-M3 -X1R5E2-M3 -X1R5F1-M3 -X1R5F2-M3 47 mm Non-shielded 2,0 mm -X2ME1-M3 -X2ME2-M3 -X2MF1-M3 -X2MF2-M3 54 mm Shielded 1,5 mm -X1R5E1-M3L -X1R5E2-M3L -X1R5F1-M3L -X1R5F2-M3L 56 mm Non-shielded 2,0 mm -X2ME1-M3L -X2ME2-M3L -X2MF1-M3L -X2MF2-M3L 44 mm Shielded 1,5 mm -X1R5E1-M1 -X1R5E2-M1 -X1R5F1-M1 -X1R5F2-M1 46 mm Non-shielded 2,0 mm -X2ME1-M1 -X2ME2-M1 -X2MF1-M1 -X2MF2-M1 60 mm Shielded 1,5 mm -X1R5E1-M1L -X1R5E2-M1L -X1R5F1-M1L -X1R5F2-M1L 62 mm Non-shielded 2,0 mm -X2ME1-M1L -X2ME2-M1L -X2MF1-M1L -X2MF2-M1L D-99

Specifications Brass type Type Ø 6,5 M8 Operating voltage 10 to 35 VDC Rated supply voltage 24 VDC Current consumption max. 15 ma at 24 VDC Sensing object Ferrous metals Mounting ((s)hielded, (n)on-shielded) *1 s n s n Operating distance in mm 1,5 2,0 1,5 2,0 Tolerance of operating distance ±10% Standard target size in mm (L x W x H in mm, FE 37) 6,5x6,5x1 8x8x1 Differential travel 1 %... 15 % of operating distance Max. response frequency in khz 5,0 -... E1 type: NPN-NO Type E2 type: NPN-NC F1 type: PNP-NO Control output F2 type: PNP-NC Max-Load 200 ma Max-on-state 2,5 VDC (at 200mA load current and with 2 m cable) Voltage drop Circuit protection Reverse polarity, output short-circuit Indicator Operating indicator (yellow LED) Ambient temperature Operating: -25 to 70 C Humidity 35 to 95 % RH Influence of temperature ± 10 % max. of Sn at 23 C in temperature range of -25 to 70 C Dielectric strength 1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case Electromagnetic compatibility EMC EN 60947-5-2 Vibration resistance Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions Shock resistance Destruction: 300 m/s² (approx. 30 G) for 6 times each in X, Y and Z directions Enclosure rating IP 67 (EN 60947-1) Connection *2 Pre-wired 2 m PVC-cable, 3 x 0,14 mm² Connector M8 plug Weight in g Pre-wired long 45 50 short 43 48 Connector long 10 15 short 8 13 Material Case Sensing face *1. For detailed mounting instruction please refer to page D-105 *2. PUR cable and different length on request. Brass PBTP D-100 Inductive Sensors

Stainless steel type Type Ø 6,5 M8 Operating voltage 10 to 35 VDC Rated supply voltage 24 VDC Current consumption max. 15 ma at 24 VDC Sensing object Ferrous metals Mounting *1 shielded Operating distance in mm 2,0 Tolerance of operating distance ±10% Standard target size in mm (L x W x H in mm, FE 37) 6,5x6,5x1 8x8x1 Differential travel 1 %... 15 % of operating distance Max. response frequency in khz 4,0 -... E1 type: NPN-NO Type E2 type: NPN-NC F1 type: PNP-NO Control output F2 type: PNP-NC Max-Load 200 ma Max-on-state 2,5 VDC (at 200mA load current and with 2 m cable) Voltage drop Circuit protection Reverse polarity, output short-circuit Indicator Operating indicator (yellow LED) Ambient temperature Operating: -25 to 70 C Humidity 35 to 95 % RH Influence of temperature ± 10 % max. of Sn at 23 C in temperature range of -25 to 70 C Dielectric strength 1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case Electromagnetic compatibility EMC EN 60947-5-2 Vibration resistance Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions Shock resistance Destruction: 300 m/s² (approx. 30 G) for 6 times each in X, Y and Z directions Enclosure rating IP 67 (EN 60947-1) Connection *2 Pre-wired 2 m PVC-cable, 3 x 0,14 mm² Connector - M8 plug Weight in g Pre-wired long 45 50 short 43 48 Connector long - 10 short - - Material Case stainless steel 1.4305 / AISI 303 Sensing face PBTP *1. For detailed mounting instruction please refer to page D-105 *2. PUR cable and different length on request. D-101

Engineering data Standardized characteristic for lateral approach axial distance related to effective operating distance (s/sr) standard target lateral approach 1,2 axial approach 1 on 0,8 0,6 0,4 0,2 0-1 -0,8-0,6-0,4-0,2 0 0,2 0,4 0,6 0,8 1 lateral distance related to radius of 'active surface' (r/ract) off 'switch-on' curve ' switch-off' curve Output Circuit Diagram and Timing Chart -@E@ NPN Output -@F@ PNP Output Brown 1 Brown 1 Main circuit 4,7 kw Load Black 4 (or 2) Main circuit 4,7 kw Black 4 (or 2) Load Blue 3 Blue 3 0 V -@E@ NPN Output Sensing object Yellow indicator Control output Yes No Lit Not lit ON OFF NO NC -@F@ PNP Output Sensing object Yellow indicator Control output Yes No Lit Not lit ON OFF NO NC Pin Arrangement at Connector Types 1. Connector M8 (viewed to plug pins) Output + - 2. Connector M12 (viewed to plug pins) NO 2 free 1 (+) NC 2 Output 1 (+) 3 (-) 4 Output 3 (-) 4 free D-102 Inductive Sensors

Dimensions Cable types -C1@R5 2M, -C2@-DS 2M -C2M@ 2M -C1R5@-L 2M, -C2@-DSL 2M -C2M@-L 2M X1R5@ 2M, X2@ DS 2M X2M @ 2M X1R5@ L 2M, X2 @ DSL 2M X2M@ L 2M D-103

Plug types -C1R5@-M3 -C2M@-M3 -C1R5@-M3L -C2M@-M3L X1R5@ M3 X2M@ M3 X1R5@ M3L, X2 @DM3S X2M @ M3L X1R5@ M1 X2M@ M1 X1R5@ M1L X2M@ M1L D-104 Inductive Sensors

Installation Caution Item Power Supply Do not impose an excessive voltage on the, otherwise it may explode or burn. Do not impose 24 VAC on any model, otherwise it may explode or burn. Examples Load short-circuit Do not short-circuit the load, or the may explode or burn. The 's short-circuit protection function is valid, if the polarity of the supply voltage imposed is incorrect and within the rated voltage range. Wiring Be sure to wire the and load correctly, otherwise it may explode or burn. Correct Use Installation Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Sensing Object Metal Coating: The sensing distance of the Proximity Sensor vary with the metal coating on sensing objects. Wiring High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cord of the Proximity Sensor, wire the cord through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Core Tractive Force Do not pull cords with the tractive force exceeding the following: pull force (N) = 20 x cable diameter ( mm) Mounting The Proximity Sensor must not be subjected to excessive shock with a ha mmer when it is installed, otherwise the Proximity Sensor may be damaged or lose the water-resistivity. Environment Water-Resistivity Do not use the Proximity Sensor underwater, outdoors or in the rain. Operating Environment Be sure to use the Proximity Sensor within operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or soluble machining oil is reco mmended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e. G., strong alkaline or acid gases including nitric, chromic, and concentrated sulfuric acid gases). D-105

Item Examples Item AND (serial connection) The Sensors connected together must satisfy the following conditions: il + (N-1) x i = Upper-limit of control output of each Sensor VS - N x VR = Load operating voltage N = No. of Sensors VR = Residual voltage of each Sensor VS = Supply voltage i = Current consumption of the Sensor il = Load current If the MY Relay, which operate at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load. OR (parallel connection) The number of Sensors connected in parallel varies with the Proximity Sensor model. Effects of Surrounding Metal Shielded types: Shielded types allow direct installation on metal plates in an embedded manner without performance change. A minimum distance of 3sn is required between the active surface and a metallic surface in front of the device. (Fig. 1). For SUS shielded types the following minimum distances are required to avoid performance change (see Fig.2 and table below): Shielded SUS Types -2@-DS Free zone 0,5 mm Non-shielded types: Installation of non-shielded types in metal require the minimum distances according to Fig. 3. 3sn d 2sn 3d 3sn Fig.3: Non-shielded type Fig.1: Shielded type (except SUS) Freezone 3sn Fig.2: Shielded SUS type ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D06E-EN-Cat04-01 In the interest of product improvement, specifications are subject to change without notice. D-106 Inductive Sensors