MINISTRY OF THE ENVIRONMENT, CLIMATE PROTECTION AND THE ENERGY SECTOR



Similar documents
Emergency Stop Push Buttons

Unified requirements for systems with voltages above 1 kv up to 15 kv

Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service

INTEL S SAFETY WARNING LABEL REQUIREMENTS

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Safety at injection moulding machines

SMS 4 / SMS 5 safety mat Product information

Application Technique. Safety Function: Magnetic Door Switch Monitoring

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Machine Guarding and Operator Safety. Leader Guide and Quiz

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Conventional Fire Detection and Extinguishant Control System Specification

Co-ordination of the Notified Bodies NB-TOYS under the Safety of Toys Directive

Safe and Efficient Hydraulic Systems Review of ISO 4413 Hydraulic Fluid Power General Rules and Safety Requirements for Systems and Their Components

IEC/EN Appliance of reference designations on machinery in accordance with ISO/IEC/EN

MACHINERY GUARDING. Your Practical Guide

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Cam Switches, Manual Motor Controllers, Disconnects For Single phase Applications

Equipment vs. Component

Technical Bulletin. Understanding Servo Safety Functionality and SIL ratings

Handicap regulations for lift. Points related to the remote alarm on passenger and goods passenger lifts

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

RMM 306 Lockout/Tagout (LOTO) Program for the Control of Hazardous Energy Page 2 June 2016

Mounting and System Description for SSZ-Safety-Mats

The ACD pro replaces any resistance based controller and is suitable for nearly any motor within the current rating.

Safety Manual BT50(T) Safety relay / Expansion relay

Risk Assessment in Accordance with EN ISO and EN ISO 12100:2010

Safety Relays ESM/ESM-F

IMPORTANT SAFETY RULES TO FOLLOW

Degrees of protection. IP codes. W.M.M. Menheere Holec Holland N.V. The Netherlands

Drill Rig Safety. Brian Stringer Former BDA National Secretary British Drilling Association. BDA Driving Site Safety Seminar Manchester United FC

Electrical Contractors Association

CARD CUTTER MACHINE STUDENT.MANUAL

Instructions For SF 6 Refill Kit

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Development of Combined Automatic Blade Control for Snow-Removing Grader

Control and Indicating Equipment

Safety Function: Door Monitoring


Page85. Lock-out Tag-out Plan

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

MIC-WKT and MIC-WKT-IR

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

How To Understand The Electrical Power Supply Of A Power Supply System

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

ELECTRICAL DOCUMENTATION ACCORDING TO STANDARDS

ECONO-OWNER DIGIPAD II. Econo Series. The Future of Computer Console Systems! OWNER S MANUAL. Tomorrow's Technology Today!

Procedure for testing the integrity of the Festo and Numatics valve stacks:

VACUUM CLEANER INSTRUCTION MANUAL

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

CONTROL OF HAZARDOUS ENERGY (Lockout Tagout)

IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO. IEC Ed.13: Rotating electrical machines - Part 1: Rating and performance.

Comprehensive Range of Industrial Products and Solutions

PABIAC Safety-related Control Systems Workshop

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

BRANN-, GASS- OG NØDAVSTENGNINGSSYSTEMER,

Original instructions Tina 3A/Aps Adaptor unit

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Engineering Specification

BUILDING INSTRUCTIONS

SOME HELP WITH BRITISH STANDARD BS EN 1570:1999 Safety requirements for lifting tables

Accident Case Studies

PowlVac Vacuum Integrity Tester

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Tina 2A/B Adaptor unit

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

CAT DETECT MINESTAR SYSTEM

Electrical safety. in control and auxiliary circuits. Safety objectives

Group TRAFFIC MANAGEMENT SPECIALIST ACCESS WAY SOLUTIONS CREATIVE SOLUTIONS TO COMMON CHALLENGES. Products

Addendum to the Operating Instructions

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

GUIDELINES ON THE APPLICATION OF DIRECTIVE 2006/95/EC

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

Oil and Coolant Circulating Heating System. Model - OCSM

Demystifying arc flash hazard management

Bypass transfer switch mechanisms

The Intelligent AX1 Switchgear for Medium Voltage

PV-Lifeline Safety in case of danger

HERZ-Thermal Actuators

Red Oak Fire Rescue SECTION: New Car Technology

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

Reverse-feed applications for circuit breakers

Cat Detect. for Surface Mining Applications

Supplying new machinery

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

ABB solutions for photovoltaics Protection and other modular devices

Procedures for daily inspection and testing of mechanical power presses and press brakes

Transcription:

MD WG 2010-03 EN rev.2 MINISTRY OF THE ENVIRONMENT, CLIMATE PROTECTION AND THE ENERGY SECTOR Ministry of the Environment, Climate Protection and the Energy Sector, Baden-Württemberg P.O. Box 103439 70029 Stuttgart Machinery Working Group Stuttgart 20.02.2014 Name Mr. Ludwig Finkeldei Extension ++49 (0) 711 126-2975 E-Mail Ludwig.Finkeldei@um.bwl.de Emergency Stop Devices (MD Annex I 1.2.4.3) Background According to Art. 5 of the MD 2006/42/EC, machinery can be placed on the market or put into service only when it satisfies the relevant EHSR set out in Annex I of the MD. With regard to the applicable EHSR, Annex I section 1.2.4.3 of the MD 2006/42/EC requires for most machinery 1 to be fitted, with one or more emergency stop devices as shown for example in Fig. 1. Fig. 1: Emergency stop device This document deals only with the design of the emergency stop device, primarily with the mushroom type push button with regard to section 1.2.4.3. The document at hand 1 The second paragraph of section1.2.4.3 of Annex I of the MD 2006/42/EC sets out two exceptions where emergency stop devices are not required. Kernerplatz 9 70182 Stuttgart (VVS: Staatsgalerie) Willy-Brandt-Str. 41 70173 Stuttgart Telefon 0711 126-0 Telefax 0711 126-2881 poststelle@um.bwl.de www.um.baden-wuerttemberg.de www.service-bw.de

- 2 - is not concerned with the location of the devices to be fitted, because this is dependent, for example on the size and configuration of the machinery, the number of operators, the location of the danger zones and the operation positions and maintenance points. With reference to the third paragraph of section 1.2.4.3, which sets out requirements for the design of emergency stop devices, such device must have clearly identifiable, clearly visible and quickly accessible control devices. Quoting the Guide to application of the MD, this is important because, in an emergency situation, a split-second reaction may be crucial. The requirement of the quick accessibility has consequences for both the choice of the type of control device and the number and location of control devices to be fitted. Harmonised standards, applicable to emergency stop devices The following harmonised standards substantiate the design and functioning of the emergency stop device. EN ISO 13850:2006, Safety of machinery emergency stop principles for design, specifies functional requirements and design principles for the emergency stop function on machinery, independent of the type of energy used to control the function. It is applicable to all machinery except for machines, in which the provision of emergency stop would not lessen the risk, and hand-held portable machines and hand-guided machines. It does not deal with functions such as reversal or limitation of motion, deflection, shielding, braking or disconnecting, which can be part of the emergency stop function. Concerning the color scheme of the red push button against a yellow background standardized in EN ISO 13850:2006 section 4.4.5, also standard EN 60073, Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators (IEC 60073:2002) can be used. This standard establishes general rules for assigning particular meanings to certain visual, acoustsic and tactile indications. The standard EN 60947-5-5 1997 + A1:2005, Low-voltage switchgear and controlgear - part 5-5: control circuit devices and switching elements - electrical emergency stop device with mechanical latching function is applicable to electrical control circuit 2

- 3 - devices and switching elements which are used to provide an emergency stop signal. Where electrical switches are used, they should have direct opening action in accordance with EN 60947-5-1, Annex K. Such devices may be either provided with their own enclosure, or installed according to the manufacturer's instructions. Emergency stop devices An emergency stop device as shown in Figure 1 comprises a specific control device linked to the control system that gives a stop command and the components or systems necessary to stop the hazardous functions of machinery as quickly as possible, without creating any further risks. The device fulfills the design requirement of clearly identifiable regarding the color scheme of the red push button against a yellow background, as well as the requirement of clearly visible and quickly accessible. Emergency stop devices with protection measures to prevent unintended activation or damage At a certain type of machinery, mainly mobile machinery or machinery in the construction sector, emergency stop devices are used with protective measures, such as collars or shrouding as sown in Fig. 2, in order to assure its proper function also under demanding conditions. Those measures are sometimes provided to prevent unintentional activation, debris or process materials accumulating on the device and preventing its operation. Fig. 2: Emergency stop device with protection against unintended activation or damage 3

- 4 - A protective collar must not have any sharp corners or edges or rough surfaces which could lead to injury. Corners and edges should be rounded and surfaces smooth to the touch. The protection collar must not impair the accessibility of the emergency stop device. A full protection collar is in principle not acceptable with regard to Annex I section 1.2.4.3 of the MD 2006/42/EC. However, its particular suitability could be demonstrated by testing. Requirements concerning the acceptable design of protective collars of emergency stop devices are not yet available in the relevant standards. However, it should be noted that the proposed amendment to EN ISO 13850 includes a test method to ensure that the collar does not impair accessibility. Disconnecting device as emergency stop According to market observations, also the disconnecting device as shown in Fig. 3 is used as emergency stop device. Fig. 3: Disconnecting device as emergency stop The supply disconnecting device is sometimes being locally operated to serve the function of emergency stop with regard to EN 60204-1 Safety of machinery Electrical equipment of machines Part 1: General requirements in which it is stated under section 10.7.4 Local operation of the supply disconnecting device to effect emergency stop : 4

- 5 - The supply disconnecting device may be locally operated to serve the function of emergency stop when: it is readily accessible to the operator; and it is of the type: a) switch-disconnector, with or without fuses, in accordance with IEC 60947-3, utilization category AC-23B or DC-23B; b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector; c) a circuit-breaker suitable for isolation in accordance with IEC 60947-2; d) any other switching device in accordance with an IEC product standard for that device and which meets the isolation requirements of IEC 60947-1 as well as a utilization category defined in the product standard as appropriate for on-load switching of motors or other inductive loads; When also intended for such use, the supply disconnecting device shall be coloured red. If a background exists immediately around the actuator, then this background shall be coloured yellow. See also ISO 13850. This allows supply disconnecting devices that meet these requirements to provide the emergency stop function. Nevertheless, it should be noted, that the supply disconnecting device is regarded as an exception and the normal emergency stop device should be used whenever possible. Stop devices covering the start and the stop-contact Stop devices covering the start and the stop-contact such as the flap stop (Fig. 4), is a special kind of stop device produced normally outside the EU, and used as a normal emergency stop for different machinery, in particular for smaller machines, such as bench drilling machines. 5

- 6 - Fig. 4: Flap stop device (taken from the original Danish document MD ADCO 2005-19) The flap-stop is a start and stop contact, which is equipped with a yellow flap and a red mushroom-type push button (Fig. 4), covering both the start and the stopcontacts. When the mushroom push button is activated, the flap will press the stop button into a stop command position. The flap can be kept in an open position which cannot assure the availability at all times. The flap stop can therefore not provide the emergency stop function as required in Annex I section 1.2.4.3 of the MD 2006/427EC. Other stop devices Sometimes, Emergency stop device are designed as padlockable stop devices to make the isolation secure. More typically padlocks will be used with devices that can directly isolate equipment from the supply of electricity, such as disconnectors, switchdisconnectors, circuit-breakers etc. Other devices to interrupt the machine movement, such as mats, light curtains, laser scanners etc.) cannot be considered to be an emergency stop device. Those devices are protective devices (as required by EHSR 1.3.7 with 1.4.3 specifying their characteristics). They are part of the safety system for the machine operation and are not an emergency stop devise that should be provided in addition. 6