SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN



Similar documents
Spill Prevention, Control and Countermeasure (SPCC) Rule

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

ABOVE-GROUND STORAGE TANKS

SPILL PREVENTION, CONTROL AND COUNTERMEASURES (SPCC) PLAN

TRAINING SPCC/SWPP Training UGA. Automotive Center. Campus Transit

SPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN PREPARED FOR: ARKANSAS STATE UNIVERSITY JONESBORO, ARKANSAS ORIGINAL DATE OF PLAN: APRIL 2005

Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans

UNIVERSITY OF WISCONSIN MADISON


Spill Control Prevention Plan (SCPP)

Kurt Wilson Louisiana Dept. of Environmental Quality Business & Community Outreach Division Small Business/Small Community Assistance Program

Spill Prevention Control and Countermeasure (SPCC) Regulations Fact Sheet

SPCC for Food Services

Spill Prevention, Control and Countermeasure (SPCC)

MODULE IV Secondary Containment, Oil Spill Control & Spill Prediction

Spill Prevention, Control and Countermeasure Plan Checklist

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN. for the PIÑON RIDGE MILL HIGHWAY 90 BEDROCK, COLORADO Prepared by:

Spill Prevention, Control, and Countermeasures (SPCC) Regulations Update

SPILL PREVENTION, CONTROL AND COUNTERMEASURE (SPCC) PLAN

Section 5. Secondary Containment and Impracticability. (as applicable to APSA tank facilities)

~CSRMA ALERT~ REVISED SPCC RULE WILL IMPACT MOST POTW S

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

SPCC Rule Review. Spill Prevention Control & Countermeasures NON-TRANSPORTATION RELATED ONSHORE AND OFFSHORE FACILITIES

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

OIL POLLUTION PREVENTION REGULATIONS

for Gary Hughes GARY HUGHES SELF SERVICE LLC State of Missouri ID: ST

DOES YOUR COMPANY NEED AN SPCC PLAN? Larry Seabolt Remtech Engineers Remediation Specialists

History of the SPCC Rule

U.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE

Civil Engineering Sector Labour-Management Health and Safety Committee

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

How To Safely Handle A Spill

Waste Oil Collection / Storage

Farm Fuel Tank Safety Guide

The following definitions apply with regard to requirements specified in this document:

Facility Scenario - Example Tier I Qualified Facility SPCC Plan

Fuel Storage Who to ask: tank farm owners/operators

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040

CHAPTER PETROLEUM CONTACT WATER

Petroleum Storage Tank Compliance 101

U.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE

Chaffee Landfill & CID Hauling Olean Road Chaffee, New York 14030

SPCC. Created by EPA in 1973 under the Clean Water Act. 10/22/2014. Spill Prevention Control & Countermeasure Plan

The Federal Spill Prevention, Control & Countermeasures (SPCC) Rule Overview

Spill Prevention, Control, and Countermeasures (SPCC) Course Material

MASSACHUSETTS INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMPUS SPILL PREVENTION, CONTROL, AND COUNTERMEASURE (SPCC) PLAN

Annual Storm Water Pollution Prevention Plan and Spill Prevention, Control and Countermeasures Plan Compliance Inspection

NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC (Sections

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Critical Regulations SUMMARY OF. Stormwater Management Regulations (National Pollutant Discharge Elimination System or "NPDES ) 40 CFR 122.

FUELING AND FUEL STORAGE

FACILITY ENVIRONMENTAL COMPLIANCE

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

Spill Prevention, Control & Cleanup SC-11

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

Rutgers Environmental Health and Safety

Spill Prevention Control and Countermeasures (SPCC) Plan (Onshore, Nonproduction Facility) Kennesaw State University

UNIVERSITY OF MICHIGAN-FLINT

SPILL PREVENTION, CONTROL AND COUNTERMEASURE (SPCC) PLAN

Safe Operating Procedure

UltraTech International, Inc. Canadian Secondary Containment Requirements

OREGON FIRE CODE Interpretations and Technical Advisories

The following definitions apply with regard to requirements specified in this document:

A Guide for Used Oil Transporter Training Programs. Following are excerpts from laws and rules pertaining to Used Oil Transporter Certification

Spill Prevention, Control and Countermeasure (SPCC) Training

Contact Person Sarah Morris-Benavides Revision 1.1 Document Plan Effective Date 07/01/2014 Review Date 03/15/2017.

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

Outdoor Storage of Raw Materials SC-33

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations

Draft. ATLANTIC COAST PIPELINE, LLC ATLANTIC COAST PIPELINEINE Docket No. PF and

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

Transcription:

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN XXXX FARM (CITY OR COUNTY), MICHIGAN CONTACT (NAME), OWNER CERTIFICATION: I hereby certify that I have examined the facility, and being familiar with the provisions of 40 CFR Part 112, attest that this SPCC Plan has been prepared in accordance with good engineering practices. Engineer: Signature: Registration Number: State: Date: 5 Year Review (statement to be signed every 5 years) I have completed review and evaluation of the SPCC Plan for this facility on and will not amend the plan as a result. (Name), Owner I have completed review and evaluation of the SPCC Plan for this facility on and will not amend the plan as a result. (Name), Owner 1-10-2003

INTRODUCTION Spill Prevention Control and Countermeasure (SPCC) plans for facilities are prepared and implemented as required by U.S. EPA regulations contained in Title 40, Code of Federal Regulations, Part112 (40 CFR 112). A non-transportation related facilities is subject to SPCC regulations if: the total aboveground storage capacity exceeds 1320 gallons; or the underground storage capacity exceeds 42,000 gallons; and if due to its location, the facility could reasonably expect to discharge oil into or upon the navigable waters of the United States. The SPCC Plan is not required to be filed with the U.S. EPA, but a copy must be available for on-site review by the regional administrator during normal working hours. The SPCC plan must be submitted to the U.S. EPA Region V regional administrator and the Michigan DEQ along with the other information specified in Part 112 if either of the following occurs: 1) The facility discharges more than 1000 gallons of oil into or upon the navigable waters of the United States in a single event. 2) The facility discharges oil in harmful quantities into or upon the navigable waters of the United States in two spill events within any twelve-month period. Spill information must be reported to U.S. EPA Region V and the Michigan DEQ within 60 days if either of the above thresholds are reached. The report is to contain the following information: 1. Name of the facility. 2. Name(s) of the owner or operator of the facility. 3. Location of the facility. 4. Date and year of initial facility operation. 5. Maximum storage or handling capacity of the facility and normal daily throughput. 6. Description of the facility including maps, flow diagrams, and topographical map. 7. A complete copy of the SPCC plan with any amendments. 8. The cause(s) of such spill(s), including a failure analysis of system in which failure occurred. 9. The corrective actions taken, including pertinent equipment repairs. 10. Additional preventive measures taken. 11. Other information as required by the administrator. The SPCC plan shall be amended within 6 months whenever there is a change in facility design, construction, operation, or maintenance that materially affects the facilities spill potential. The SPCC plan must be reviewed by the operator every 5 years. When changes that affect the potential for spills are made to the facility, the SPCC plan must be re-certified by a registered professional engineer. Page 2 of 9

FACILITY INFORMATION Name: Mailing Address: Other Personnel: Location: The facility is located on the east side of (road name) in Section XX, (Name) Township in (Name) County. Facility Description: The fueling facility is located on a farm setting. The facility is used for fueling of farm equipment. Fixed Storage: Portable Storage: Total Oil Storage: Delivery Vehicles: 1 - XXX gallon gasoline above ground horizontal tank 2 XXX gallon diesel fuel above ground horizontal tank X 55gallon oil drums will be stored in the shop. They will contain used motor oil and new oil. XXXX gallons Transport truck with maximum compartment size of 1000 gallons. Page 3 of 9

On this page, provide drawing of fuel storage facility area showing wells, buildings, streams, fuel tanks and locations and distances to fuel tanks from: 1) Adjacent buildings including storage areas for other oil products 2) Wells 3) Direction of flow in case of discharge (include north arrow on drawing) 4) Distance to surface waters, storm drains or other conduit to surface waters 5) Location of spill cleanup materials such as sand or kitty litter 6) Location of covered storage for contaminated materials 7) Spill exit locations from property Page 4 of 9

PAST REPORTABLE SPILL EXPERIENCE Event Corrective Action Taken 1. POTENTIAL EQUIPMENT FAILURES Potential Event Complete failure of a XXX gallon gasoline tank and containment: Complete failure of a XXX gallon diesel fuel tank and containment: Partial failure of a full tank and containment: Spill Direction and Distance to Surface Waters or Drain Inlet East to road ditch 50 East to road ditch 50 East to road ditch 50 Pipe or hose failure: East to road ditch 50 Tank truck leak or East to road ditch 50 failure: Hose leak during truck East to road ditch 50 unloading: Pump rupture or East to road ditch 50 failure: Volume Released XXX gallons XXX gallons Spill Rate Instantaneous Instantaneous 1 to XXX gallons Gradual to instantaneous 1 to 100 gallons Up to 5 gallons per minute 1 to XXX gallons Gradual to instantaneous 1 to 100 gallons Up to 5 gallons per minute 1 to 100 gallons Up to 5 gallons per minute CONTAINMENT AND DIVERSIONARY STRUCTURES The XXX gallon tanks are double wall meeting the requirements of UL 142. The area adjacent to the concrete loading pad, where the delivery trucks are parked during fuel transfers. The area adjacent to the fuel pad is used for catchment in the event of failure of one of the compartments (catchment volume equal to or greater than the largest delivery truck compartment volume of 1000 gallons). The presence of rainwater buildup may preclude any transferring of oil product from taking place unless there remains at least 1000 gallons of catchment volume. A drain pipe to the ditch shall have its valve closed when transfers take place. The valve will be reopened after fuel transfer is complete. Page 5 of 9

In the event of a spill, the operator will immediately excavate contaminated soil, and place on the concrete floor of the shop. The shop doors will remain open until the contaminated soil is removed. DEMONSTRATION OF PRACTICABILITY Facility management has determined that use of the double wall tank containment and indoor storage of smaller containers along with available equipment to clean up spills from reaching navigable waters is practical and effective at this facility. Available sorbent materials include soils and kitty litter for the smaller storage areas. Their locations are shown on the drawing on page 4. FACILITY DRAINAGE If a spill occurs, immediate clean up will be completed by the operator. BULK STORAGE TANKS 1) Each bulk storage tank is of UL-142 double wall tank construction, and is compatible with the fuels they contain and conditions of storage. 2) Tanks will be visually inspected weekly to determine corrosion potential and condition of hoses, pumps and piping. 3) Each tank is equipped with a gage to read fuel levels. Venting capacity is suitable for the fill and withdrawal rates. Level devices are checked periodically for accuracy. 4) There have been no security issues at this facility over the past 10 years. Locked tank drains, discharge valves and pump start switches along with security lighting are provided in lieu of security fencing. Cost and inconvenience issues make fencing impractical for this farm operation. 5) Oil leaks which result in the loss of oil from tanks will be promptly repaired. 6) The 55-gallon drums are located in the shop. The shop floor is sloped to drain to the middle and a 55 gallon capacity is available for containment of oil within the shop. 7) The whole farmstead is located where periodic flooding does not occur. TRANSFER OPERATIONS AND PUMPING 1) All pipe and hose supports are properly designed to minimize abrasion and corrosion and to allow for expansion and contraction. 2) Barriers are provided to prevent vehicles from damaging tanks. Page 6 of 9

INSPECTIONS AND RECORDS Weekly visual inspections consist of a walk around the containment and the storage areas in the shop. During these inspections, tanks are checked for leakage or damage. Soils adjacent to the tanks are also examined for discoloration. All pipelines and valves are examined monthly. The checklist provided in Attachment A is used during quarterly inspections. Quarterly inspection records are to be kept for a period of three years. SECURITY 1) The facility is well lighted. 2) The pump controls and tank drain valves are locked when not in use. 3) The filler for the tank is locked when not in use. PERSONNEL, TRAINING, AND SPILL PREVENTION PROCEDURES The facility manager is accountable for oil spill prevention. Persons filling farm machinery will observe fuel transfer operations to assure spills are immediately detected. Persons filling the tanks from the delivery trucks will observe the filling operation to assure that spills are immediately detected. Department of Transportation (DOT) regulations will be followed during oil product transfers. Wheel chocks or signs warning the delivery truck driver not to depart before all hoses are disconnected will be used to prevent early departure of the fuel delivery trucks. Prior to departure of the fuel delivery truck, the driver will inspect the nozzles for leaks. REPORTABLE SPILLS A Report to Michigan DEQ is required if there is a release of oil to the waters of the state that causes visible sheens or oil films. Discharging, leaking or spilling less than 55 gallons of oil to surface waters of the state is not a release if effective recovery measures are implemented immediately upon detection. A report to the Michigan DEQ is required if there is a release of 50 pounds of oil to the ground. Discharging, leaking or spilling less than 55 gallons of oil to the ground surface if the spill, leak, and discharge is detected and the oil recovered within 24 hours, and if oil is not released directly to surface water. A notification to the National Response Center (NRC) is required if any amount of oil is discharged into navigable waters (reportable spill or harmful discharge). A harmful discharge is one that caused a film or sheen upon water or is a deposition upon the water s bottom or shoreline. Page 7 of 9

ADDRESSES AND TELEPHONE NUMBERS 1. Owner 2. Michigan Department of Environmental Quality P.O. Box 30473 Lansing, MI 48909-7973 Pollution Emergencies: 1-800-292-4706 3. National Response Center (NRC) - (800) 424-8802 4. Regional Administrator US-EPA-Region V 77 West Jackson Blvd. Chicago, IL 60604 CERTIFICATION OF SUBSTANTIAL HARM DETERMINATION (Replaces C-II Form) The (Name) Farm has less than 42,000 gallons of oil storage capacity. This facility cannot reasonably be expected to cause substantial harm to the environment by discharging oil. A facility response plan is not required. CERTIFICATION I certify under penalty of law that I have the authority to commit the resources necessary to implement this plan. I believe that the submitted information is true, accurate and complete. Signature Facility Manager Title Printed Name Date Page 8 of 9

FACILITY INSPECTION CHECKLIST ATTACHMENT A Instructions: This inspection record will be completed quarterly. Place an X in the appropriate line for each item. Add comments as needed. Attach another sheet for additional comments. Yes No Description and Comment Tank surfaces show signs of leakage Tanks are damaged, rusted, or deteriorated Tank supports are damaged or rusted Level gages are inoperative Vents are obstructed Valve seals or gaskets are leaking Loading/Unloading area is damaged or deteriorated Locks are not in place or are not functioning Lighting is not working Remarks: Signature: Date: : Page 9 of 9