DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs



Similar documents
DataSMART 681, 696 and 698

Loop-IP6700 TDMoEthernet

TDMoEthernet. Description

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Loop-IP6700 TDMoEthernet

Loop-IP6510 Multiple WAN Router/Bridge

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

These highly flexible interface cards facilitate several important applications:

DXC Family. Multiservice Access Node FEATURES

Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

Chapter 4 T1 Interface Card

How To Set Up An Ipad Dsu/Csu With A Power Adapter And Power Cable (I2) With A Dsu Or Csu (Dsu) With An Ipa (Dsi) With Power Adapter (Dse)

F2400 FOM II Series Fiber Optic Modem Technical Manual

Loop-IP6702 TDMoEthernet

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ORION TELECOM NETWORKS INC. T1

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

WEB RANger-II Internet Access Router

Appendix A QUICK Specifications

Cisco Channelized T1/E1 and ISDN PRI Modules

24-Port Channelized E1/T1 Line Card Overview

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Product Overview. Features CHAPTER

Document

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Connecting Serial Interface Cards to a Network

Cisco Packet-over-T3/E3 Service Module

Setting Up and Testing the MAX Hardware

VALIANT COMMUNICATIONS LIMITED

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

G.703 Fractional T1 Access Unit. User Guide

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Cisco Communication Media Module

Cisco 2- and 4-Port Clear Channel T3/E3 Shared Port Adapters Version 2

Xpress2500 Access System

T1 Backhaul Connectivity Solution All Products :: Application Note

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Network Monitoring White Paper

IPmux-1E TDM Pseudowire Access Gateway

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

FCD-E1E Managed E1 and Fractional E1 Access Device

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Product Specifications

Cisco One and Two Port T1/E1 Multiflex Voice/WAN Interface Cards

SRX 210 Services Gateway T1/E1 Mini-Physical Interface Module

FlexPoint T1/E1 Copper to Fiber Line Driver

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Rack mounted telephone- and leased line modem for industrial applications

Figure 1 - T1/E1 Internet Access

Cisco Third-Generation 1-, 2-, and 4-Port T1/E1 Multiflex Trunk Voice/WAN Interface Cards

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Cisco TelePresence MSE 8000

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

NetVanta 3000 Series Routers Hardware Installation Guide

Cable Specifications. T3 Trunk Cabling APPENDIX

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

Chassis, Power Supply, and Element Management

Product Documentation on the World Wide Web

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

BridgeWay Fixed Base Radio Telecom VoIP Gateway

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

SOLUTIONS FOR AN EVOLVING WORLD IMUX 2000 T1/E1 MDACS. Cross-Connect Switch IMUX 2000 T1/E1 1

How To Run An Nport I5000A Device Server

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Uninterruptible Power Supply

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Cisco 2500 Series. Product Overview. Key Features and Benefits. Specifications. Hardware

Supports T1/E1 and T3/E3/STS-1 (EC-1) Interfaces. NEBS-Level 3 Compliant. Remote Testing from a Centralized Location. Testing and Management

Cable Pinouts. SRP I/O Module

Product Documentation on the World Wide Web

DXC-8R/10A/30 Multiservice Access Nodes

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

VALIANT COMMUNICATIONS

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

FarSync T2Ue. A 2 port PCI Express synchronous communications adapter

SOHOware Long Reach Ethernet (LRE) Solution

3500/22M Transient Data Interface

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

Optimux-134, Optimux-125

Total Access SHDSL T1/E1 Line Terminating Unit Installation and Maintenance Practice

Smart 16e Shelf. User Manual. Smart 16e, 2nd Gen, Dual DC Version L8

Cisco TelePresence MSE 8000

1 Serial RS232 to Ethernet Adapter Installation Guide

Transcription:

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8 = PDF Leased Line Economical T1 Internet Access Central Site T1 Management T1/FT1 Single-port Plug-in DSU/CSUs Key Features Specifications Ordering Information Back Panel & Cabling Information Ask An Expert D-SERV 56/64- SNMP 456 458 FrameVision Upgrade Kit 554 & 558 656 658 FrameVision Upgrade Kit 656 & 658 Alarms Utility Installer Description The Single-port Plug-In DSU/CSUs are designed for high-density T1/FT1 network installation. These DSUs provide rapid expansion capabilities and comprehensive management options appropriate for central offices, and corporate and government networks. The Plug-ins provide a management system for your entire T1/FT1 network. Key Features Plug-ins for the the Universal Shelf Future-proof with easy field upgrade to FrameVision managed Frame Relay Comprehensive T1/FT1 performance monitoring, control and diagnostic tools Standards-based in-band management with embedded SNMP 554 includes data port for router or video connectivity 5-year warranty The 558 also provides:

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 2 of 8 T1 add/drop port for PBX connectivity Ethernet port manages one shelf, multiple shelves, or your entire T1 network The Plug-ins offer auto-configuration for fast provisioning of additional circuits in rapidly growing environments. Combined with Installer, this eliminates the need for highly skilled on-site technicians. You can manage all Plug-Ins and remote s over a native Ethernet connection on the 558 unit. With multiple SNMP or TELNET sessions to a shelf, precious time can be saved at the network control center, by allowing multiple operators to troubleshoot problems concurrently. The 558 DSU/CSU controller card loads complete configuration information to new 554 Plug-in cards when they power up -- preassigning T1 network parameters, allocating bandwidth to the data port, initializing system information, and activating the embedded SNMP agent. Specifications Network Interface Common Line Rate Line Code Line Impedance Connectors Lightning Protection Framing Format Protocol Input Only Input Level Internal or external clock; 1.544 Mbps +/- 50 bps. When timing is derived from input signal: 1.544 Mbps +/- 200 bps. Output line rate follows input line rate. AMI, B8ZS 100 ohms +/- 10 ohms at 772 khz. 100 ohms +/- 20% over the frequency band 100 khz to 1 MHz. 2-slot shelf: RJ48C socket. 12-slot shelf: DA15 plug. Lightning surges defined per FCC Part 68 will not damage unit. SF or ESF per ANSI T1.403-1989, and TR-54016-1989. Ericsson Framing (defined as valid F T bits only). Frame Relay or ATM DXI DSX-1 to -27.5 db Input Jitter Tolerance Per TR 62411-1990 (p. 4.7.1) Output Only Output Level Output Signal Line Build Out Per ANSI T1.403-1989 3.0 Volt peak +/- 10% into 100 ohms at output connector Tolerant to impedance mismatches 0, 7.5, 15.0 selectable Output Jitter TR 62411-1990 (p. 4.7.2) Jitter Transfer DSU: TR 62411-1990 (p. 4.7.3)

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 3 of 8 Terminal Interface (Add/Drop Port: Model 558 only) Common Line Rate Line Code Line Impedance Connectors Framing Format Input Only Input Level Internal; 1.544 Mbps +/- 50 bps. When timing is derived from input signal: 1.544 Mbps +/ - 200 bps. Output line rate follows input line rate. AMI, B8ZS (selectable) 100 ohms +/- 10 ohms at 772 khz. 100 ohms +/- 20% over the frequency band 100 khz to 1 MHz. 2-slot shelf: RJ48C socket. 12-slot shelf: DA15 plug. SF or ESF per ANSI T1.403-1989, and TR-54016-1989. Ericsson Framing (defined as valid F T bits only). Idle ESF Data Link is set to 1s. DSX-1 to -10.0 db Input Jitter Tolerance Per TR 62411-1990 (p. 4.7.1) Input Jitter Transfer Per TR 62411-1990 (p. 4.7.2) Output Only Output Level Equalization DSX-1 at connector (no equalization enabled) Up to 655 feet selectable, 5 steps Serial Control Port Interface Baud Rate 2400, 9600, 19200, 38400 Electrical EIA-574 DCE Connector DB9S DTE Connector DB9P Data Port Interface Bit Rates Electrical Connector Nx56 Kbps or Nx64 Kbps (N=1...24) V.35 compatible DB25 socket Power AC Input Range Power Interruptions 24 to 48 VDC @ 7 watts Loss of power does not damage unit.

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 4 of 8 Management Control Ports Ethernet Port (Model 558 only) Loss of power for less than five years does not change the configuration settings which may have been set by the user. Loss of power for less than two hours (nominal) does not affect the real-time clock setting. DCE and DTE EIA-574 DE9 socket Daisy chain 38.4 kbps maximum English menus Async ASCII or SLIP/PPP 10Base-T RJ45 socket Transmit and receive LEDs SNMP Agent MIB II (RFC 1213) Frame Relay DTE MIB, Circuit Table (RFC 1315) DS1 MIB (RFC 1406) Enterprise MIB TELNET server Responds to Ping Security filters (for IP source addresses) Up to 10 SNMP Trap hosts In-band From network or router Shared or dedicated VC Frame Relay or ATM DXI Diagnostics LEDs Loop Tests Power/fail Auto Configuration (558 only) Network Interface Data Network Interface Code Violation Network Interface Red Alarm Network Interface Yellow Alarm T1 Code Violation (558 only) T1 Status (558 only) Test status Data port transmit Data port receive Data port CTS Data port RTS Ethernet Link (558 only) Ethernet Transmit (558 only) Local loopback Data terminal loopback Terminal interface loopback (558 only) T1 Local Loop Diagnostics Loop Tests Line Test Codes Line loopback Payload loopback Data port loopback QRS

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 5 of 8 3-in-24 1-in-8 All 1s All 0s Data Test Codes 511 2047 BERT Tester Independent BERT on all test codes T1 Local Loop Performance Monitoring Methodology Data Storage Monitors Registers Reports T1.403 in-band performance monitoring Last 24 hours of data in 15 minute increments. Last 7 days of data in 24-hour increments. Network interface Separate for carrier and user Based on G.821 for performance Far end Alarm history Network interface statistical Alarms Traps ASCII SNMP Traps via SLIP/PPP, Ethernet or in-band Transmitted out async control port Physical Usage Dimensions Weight Rack mount 2-slot shelf: 17" W x 1.75" H x 12" D 12-slot shelf: 17" W x 7" H x 12" D 2-slot shelf: 8 lbs, empty 12-slot shelf: 12 lbs, empty Plug-in models: 1 lb (approx) Environment Operating Storage 0º to 50º C 5% to 90% RH, non-condensing -20º to 66º C 5% to 65% RH Compatibility AT&T TR 54016-1989 TR 62411-1990 TR 54019A PUB 43802 ANSI T1.403-1995

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 6 of 8 Bellcore TR 194 Regulatory FCC Compliance Part 68; Part 15, Class A NRTL Listed UL 1950, 3rd Edition CSA 22.2; No. 950 IC CS-03 Ordering Information Part Number Description 72554 554 T1 DSU/CSU Plug-in 72558 558 T1 Add/Drop DSU/CSU Plug-in with Ethernet 72081 FrameVision Upgrade Kit for 554 and 558 Plug-in DSU/CSUs 78270 Universal Shelf, 12 slots, DC 78272 Universal Shelf, 12 slots, DC, for use in Canada (CSA) 78075 Universal Shelf, 2 slots, AC 78070 Universal Shelf, 2 slots, DC Power Supplies 120VAC to: 77092 24/48 VDC, 1.25 amps up to 4 units 72073 48 VDC, 100 watts up to 1 shelf (12 units) 72075 48 VDC, 100w x 2 (2 shelves), or 100w redundant (1 shelf) 72079 48 VDC, 100w x 4 (4 shelves), or 100w redundant (2 shelves) Back Panel and Cabling Information 2-slot shelf RJ48 - To Network 930xx141 RJ48C Plug to RJ48C Plug 930xx142 RJ48C Plug to RJ48C Plug, Crossover RJ48-To Terminal Equipment 930xx142 RJ48C Plug to RJ48C Plug, Crossover

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 7 of 8 DE9-To Control Terminal 95006022 DE9S to DE9P, 6 feet 95005023 DE9S to DB25P, 5 feet 93001211 DE9P to RJ48, Cisco 2500 SLIP, Control Port 78899 DE9S to RJ45 Adapter 78891 Installation Kit DB25 - To Data Terminal Equipment V.35 95010054 DB25P to MRAC34P, 10 feet 95010073 DB25P to MRAC34P, tail circuit timing 95001074 DB25P to MRAC34S, 1 foot 78904 DB25P to MRAC34S Adapter 78905001 V.35 Adapter to existing single-port cable 78906001 DB25P to MRAC34S (Wellfleet) EIA-530 950xx042 DB25P to DC37S 95010061 DB25P to DB25P, 10 feet 95010058 DB25P to DB25P, tail circuit timing 95010066 DB25P to DC37P (EIA-530 to RS449) 12-slot shelf DA15 - To Network 930xx091 DA15S to DA15P 930xx111 DA15S to Stub 930xx151 DA15S to RJ48C Modular Plug 77891 DA15S to RJ48C Jack Adapter 77993004 DA15S to Barrier Strip Adapter DB25-To Terminal Equipment Terminal Equipment Only 950xx094 DB25P to RJ48C Plug Terminal and Data Equipment The 12-slot Shelf requires split cables to access data and terminal equipment simultaneously 95001088 DB25P to DB25S and DA15P 95001089 DB25P to DB25S and DA15S 95001090 DB25P to MRAC34S and DA15P

554 & 558 T1/FT1 Plug-in DSU/CSUs Page 8 of 8 95001090 DB25P to MRAC34S and DA15P 95001091 DB25P to MRAC34S and DA15S DE9-To Control Terminal 95006022 DE9S to DE9P, 6 feet 95005023 DE9S to DB25P, 5 feet 93001211 DE9P to RJ48, Cisco 2500 SLIP, Control Port 78899 DE9S to RJ45 Adapter 78891 Installation Kit DB25 - To Data Equipment The 12-slot shelf requires split cables to access both data and terminal equipment simultaneously. V.35 95010054 DB25P to MRAC34P, 10 feet 95010073 DB25P to MRAC34P, tail circuit timing 95001074 DB25P to MRAC34S, 1 foot 78904 DB25P to MRAC34S Adapter 78905001 V.35 Adapter to existing single-port cable 78906001 DB25P to MRAC34S (Wellfleet) EIA-530 950xx042 DB25P to DC37S 95010061 DB25P to DB25P, 10 feet 95010058 DB25P to DB25P, tail circuit timing 95010066 DB25P to DC37P (EIA-530 to RS449) xx denotes length of cable, contact factory for available lengths. DA, DB, DC, DE designate the size of the shell which encapsulates the cable connector. P = Plug (male); S= Socket (female).