CS270F SmartSpan T1 Line Repeater w/addressable Bidirectional Loopback



Similar documents
Transformer-coupled passive transmit path with a fixed insertion loss of approximately 1.0dB.

CS239A and CS239E T1 Line Repeaters

Westell IDR9186SB Intelligent High-Density T1 Office Repeater

2-Pair HDSL1 Adtran Fiber Optic Link System

ORION TELECOM NETWORKS INC. T1

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Chapter 4 T1 Interface Card

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Setting Up and Testing the MAX Hardware

T-BERD 107A. T-Carrier Analyzer

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

UIM-2T1 T1 Loop Bonding Uplink Interface Module

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

G.703 Fractional T1 Access Unit. User Guide

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

10-3. SYSTEM TESTING AND DOCUMENTATION

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

BroadBand PowerShield. User Manual

Current Probes. User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ICW-6 Window Intercom. Installation and Operation Instructions

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

RLH 2 Wire Digital Phone Fiber Link Card System

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

About the BitStorm 6051 POTS Splitter

Loop-IP6700 TDMoEthernet

TAM Port T1 Access Multiplexer

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Contents. Safety Warnings... 1

LDG DTS-6/6R Desktop Coaxial Switch / Remote

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

T3 Mux M13 Multiplexer

IP DSLAM IDL Quick Installation Guide

HDO700 P FIBRE OPTIC TRANSMITTER

Loop-V4300 MINI DACS E1/ T1 CONVERTER

OPERATION FIC SOC (USOC) JACK T1 CSU Interface 04DU9-1SN 6.0N RJ48C 04DU9-1ZN

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

CONTROL SWITCHER User s Manual (Preliminary)

CIC-50. T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems)

PCS300 Universal IP Reporting Module V1.0

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

T-Extender E-Extender

TDMoEthernet. Description

PS 155 WIRELESS INTERCOM USER MANUAL

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

F2400 FOM II Series Fiber Optic Modem Technical Manual

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

TrueAlarm Fire Alarm Systems

PRISM 3001 FT1/T1 CSU/DSU

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

NXU RoIP Link to Eliminate Voice-Grade Leased Line

INSTRUCTION MANUAL MODEL PCD-88

DS2186. Transmit Line Interface FEATURES PIN ASSIGNMENT

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide

Dial Backup Module (DBM) Two standoff posts, four washers, and four Phillips-head screws 14 RJ49C ISDN-U cable Warranty card

the promoh OPERATING MANUAL

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

ECONseries Low Cost USB DAQ

ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual

Cisco Channelized T1/E1 and ISDN PRI Modules

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

DS-3 Technology and Testing Overview

Voltage Regulator SPAU 341 C. Product Guide

SECTION DETECTION AND ALARM

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

25 Code GTO Digital Keypad

ASP-DTH. DVI & Audio to HDMI Converter. User Manual. Manual Number:

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

Agilent E5100A Network Analyzer

Loop-IP6510 Multiple WAN Router/Bridge

Y-Not. User s Manual. RJM Music Technology, Inc.

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

DMX2PWM 9 Channel Dimmer Setup Manual

HCR3.2/.. Chipcard reader HOTEL SOLUTION

FTW Wireless Monitoring System Reference Manual Part Number

USER GUIDE. Publication AP8509. Allen & Heath 1 XONE:K2 User Guide

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Transcription:

Telecommunications Group Section CS2 70F 201 Equipment Issue 1 Third Printing, October 2000 CS270F SmartSpan T1 Line Repeater w/addressable Bidirectional Loopback CONTENTS PAGE Part 1. GENERAL............................................................................. 2 Part 2. INSPE........................................................................... 2 Part 3. OPTIONS.............................................................................. 3 Part 4. TESTING.............................................................................. 5 Part 5. TECHNICAL ASSISTANCE.............................................................. 5 Part 6. WARRANTY & CUSTOMER SERVICE.................................................... 6 Part 7. SPECIFICATIONS...................................................................... 7 CS270F T1 RPTR Figure 1. CS270F SmartSpan T1 Line Repeater 2000 Charles Industries Ltd. CLEI is a trademark of Bell Communications Research, Inc. All rights reserved. Printed in United States of America. The availability of features and technical specifications herein subject to change without notice. Page 1 of 7

Section CS2 70F 201 1. GENERAL 1.1 Document Purpose This document provides installation and testing information for the Charles Industries CS270F T1 Line Repeater shown in Figure 1. See Figure 2 for the CS270F Block Diagram. 1.2 Document Status This document is reprinted to include a general editorial update. 1.3 Equipment Function The Charles CS270F T1 Line Repeater, which is part of the SmartSpan System, provides bidirectional signal regeneration and addressable signal loopback. The SmartSpan System consists of T1 Line Repeaters (CS270F) packaged in standard 239-type mechanics, and T1 Powering Repeaters (3423 7F) in AT&T 220 mechanics and (3192 7F) in Charles STS 3192 mechanics. For additional information on the SmartSpan System refer to Section CS2 70F 100. 1.4 Equipment Location/Mounting The CS270G is a 239-type plug-in module that mounts in standard 239-type mechanics. Installation and removal of modules should be done with care. Do not force a module into place. If excessive resistance is encountered while installing a module, remove the module, and check the card guides and connector to verify proper alignment and the absence of foreign material. 1.5 Equipment Features The CS270F T1 Line Repeater includes the following features: 239 type mechanics Auto Power Loop (APL) feature keeps office side repeaters powered during field side failure Bidirectional signal loopback allows one person testing from the field or office Loop or Thru powering Accommodates 60mA spans Bidirectional span power operation Receive regeneration with wide range ALBO to accommodate 0 to 35dB cable loss Front-panel-mounted LED indicators showing loopback and APL status Lightning protection per TR-TSY-00057 Meets TR-TSY-000499 jitter requirements 2. INSPE 2.1 Inspect for Damages Inspect the equipment thoroughly upon delivery. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company. 2.2 Equipment Identification Charles Industries equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment. Each time a major engineering design change is made on the equipment, the issue number is advanced by 1 and imprinted on subsequent units manufactured. Therefore, be sure to include both the model number and its issue number when making inquiries about the equipment.

2.3 Static Concerns Each module is shipped in static-protective packaging to prevent electrostatic charges from damaging static-sensitive devices. Use approved static-preventive measures, such as static-conductive wrist straps and a static-dissipative mat, when handling modules outside of their protective packaging. A module intended for future use should be tested as soon as possible and returned to its original protective packaging for storage. STATIC-SENSITIVE Use approved static preventive measures (such as a static-conductive wrist strap and a static-dissipative mat) at all times whenever touching units outside of their original, shipped static-protective packaging. Do not ship or store units near strong electrostatic, electromagnetic, or magnetic fields. Use static-protective packaging for shipping or storage. INPUT SIDE 1 5 6 FLB SIDE 1 OLB NOTE OUTPUT SIDE 1 POWER C O NT R O LL E R LOOPBACK DETECTOR APL GENERATOR THRU LOOP PLB SLB (STEADY) NP (FLASH) AUTOMATIC THRU-LOOP SWITCHING & CONTROL OUTPUT SIDE 2 Note: 9 8 NOTE APL Relay contacts shown for descriptive purposes only. All switching done electronically FLB SIDE 2 OLB INPUT SIDE 2 Figure 2. CS270F T1 Line Repeater Block Diagram 3. OPTIONS The CS270F is equipped with slide switches and a front-panel-mounted rotary switch which are used to condition the module for the required operation. Option locations are shown in Figure 3. 3.1 Switch S2 (LOOP, THRU) Place switch S2 in the LOOP position if the unit is to be powered from the span. If the unit and CI terminal equipment are to be powered from the span, place S2 in the THRU. 3.2 Front-Panel-Mounted Rotary Switch S3 and Slide Switch S4 (Repeater Address Code) Referring to Table 1, set the front panel code switches S3 and S4 for the desired address. To disable the loopback code detector, place switch S3 in the X position. S3 in the X position will cause the NP/SLB LED to flash. Note: Switch S4 has no effect when the switch S3 is in the X position.

Section CS2 70F 201 Figure 3. CS270F Front Panel Function and Option Locations Table 1. CS270F Front Panel Function and Option Summary Item Position or State Description NP/SLB (Red) LED Continuous Indicates loopback transmission. Flash Indicates that no address has been assigned (not provisioned). PLB (Red) LED ON Indicates that the unit has detected a field side open condition and automatically switched to LOOP SX powering. S2 (LOOP, THRU) LOOP Unit is to be powered from the span. THRU Unit and CI terminal equipment are to be powered from the span. Physical Address Bit Assignment (NNNNN) S3 Address (NNNNN) Address (NNNNN) Address (NNNNN) A 00001 L 01011 AF 10110 B 00010 M 01100 AG 10111 PCB C 00011 1 01101 AH 11000 D 00100 2 01110 AJ 11001 E 00101 0 01111 AK 11010 S4 F 00110 AA 10001 AL 11011 G 00111 AB 10010 AM 11100 Rotary switch S3 in the X position dis- H 01000 AC 10011 A1 11101 ables the loopback capabilities of the unit. Switch S4 has no effect when J 01001 AD 10100 A2 11110 rotary switch S3 is in the X position. K 01010 AE 10101 A0 11111 EXAMPLE 1: To assign address B to the unit, set S3 to position B and S4 to position ( ) EXAMPLE 2: To assign address AB to the unit, set S3 to position B and S4 to position A( ), i.e. A(B) EXAMPLE 3: To assign address A1 to the unit, set S3 to position 1 and S4 to position A( ), i.e. A(1)

4. TESTING Use the following steps to test the CS270F. This is a basic test, and is performed with the unit in-service. Step Action Verification 1. Perform an office side loop-up function on the repeater (being tested) by sending the following 16 bit repeating pattern: 11111111 00 NNNNN 0 (where NNNNN is the address of the repeater being tested). Leftmost bit transmitted first. 2. Remove the repeating pattern. Normally the unit will time out after 20 minutes and return to the idle state. The 20-minute time period can be extended indefinitely by sending the loop-up request again as in Step 1, before the 20-minute time out ends. 3. Loop-down the unit by sending a standard DS1 Interface Connector Loop-down command in either SF (11100 repeating pattern) or ESF (1111111 0 010010 0 in the ESF data link). Standard TR- TSY-000312 criteria apply for these commands. A standard CSU loop-down command (100 repeating pattern) can also be sent to loop-down the unit. 4. Perform a field side loop-up function on the repeater (being tested) by sending the following 16 bit repeating pattern: 00111111 00 NNNNN 0 (where NNNNN is the address of the repeater being tested). Leftmost bit transmitted first. 5. Repeat Step 2. After 5 8 seconds the repeater being tested loopsup and returns the 11111111 00 NNNNN 0 repeating pattern. SLB/NP LED lights. SLB/NP LED extinguishes. After 5 8 seconds the repeater being tested loopsup and returns the 00111111 00 NNNNN 0 repeating pattern. SLB/NP LED lights. 6. Repeat Step 3. SLB/NP LED extinguishes. 7. This concludes the test. Note: If unframed repeating pattern: 11111110 00 NNNNN 0 is received at the office side, the repeater has detected a field side open and has automatically switched to LOOP SX powering. The PLB LED will light. The NNNNN is the address of the repeater beyond which the open occurred. 5. TECHNICAL ASSISTANCE If technical assistance is required, contact Charles Industries Technical Services Center at: 847 806 8500 847 806 8556 (FAX) 800 607 8500 techserv@charlesindustries.com (e-mail)

Section CS2 70F 201 6. WARRANTY & CUSTOMER SERVICE 6.1 Warranty Charles Industries, Ltd. offers an industry-leading, 5-year warranty on products manufactured by Charles Industries. Contact your local Sales Representative at the address or telephone numbers below for warranty details. The warranty provisions are subject to change without notice. The terms and conditions applicable to any specific sale of product shall be defined in the resulting sales contract. Charles Industries, Ltd. 5600 Apollo Drive Rolling Meadows, Illinois 60008 4049 847 806 6300 (Main Office) 847 806 6231 (FAX) 6.2 Field Repairs (In-Warranty Units) Field repairs involving the replacement of components within a unit are not recommended and may void the warranty and compatibility with any applicable regulatory or agency requirements. If a unit needs repair, contact Charles Industries, Ltd. for replacement or repair instructions, or follow the Repair Service Procedure below. 6.3 Advanced Replacement Service (In-Warranty Units) Charles Industries, Ltd. offers an advanced replacement service if a replacement unit is required as soon as possible. With this service, the unit will be shipped in the fastest manner consistent with the urgency of the situation. In most cases, there are no charges for in-warranty repairs, except for the transportation charges of the unit and for a testing and handling charge for units returned with no trouble found. Upon receipt of the advanced replacement unit, return the out-of-service unit in the carton in which the replacement was shipped, using the preaddressed shipping label provided. Call your customer service representative at the telephone number above for more details. 6.4 Standard Repair and Replacement Service (Both In-Warranty and Out-Of-Warranty Units) Charles Industries, Ltd. offers a standard repair or exchange service for units either in- or out-of-warranty. With this service, units may be shipped to Charles Industries for either repair and quality testing or exchanged for a replacement unit, as determined by Charles Industries. Follow the Repair Service Procedure below to return units and to secure a repair or replacement. A handling charge applies for equipment returned with no trouble found. To obtain more details of this service and a schedule of prices, contact the CI Service Center at 217 932 5288 (FAX 217 932 2943). Repair Service Procedure 1. Prepare, complete, and enclose a purchase order in the box with the equipment to be returned. 2. Include the following information: Company name and address Contact name and phone number Inventory of equipment being shipped Particulars as to the nature of the failure Return shipping address 3. Ship the equipment, purchase order, and above-listed information, transportation prepaid, to the service center address shown below. CI Service Center 503 N.E. 15th St., P.O. Box 339 Casey, IL 62420 2054 4. Most repaired or replaced units will be returned within 30 or 45 days, depending on the product type and availability of repair parts. Repaired units are warranted for either 90 days from the date of repair or for the remaining unexpired portion of the original warranty, whichever is longer.

7. SPECIFICATIONS The electrical and physical characteristics of the CS270F Line Repeater are as follows: 7.1 Electrical (a) OFFICE REPEATER TYPE: Regenerative transmit and receive. (b) LINE SIGNAL TYPE: Bipolar at 1.544Mbps +200bps. (c) REPEATER LINE SIGNAL PULSE AMPLITUDE: 2.4 to 3.0V peak. (d) REPEATER LINE SIGNAL PULSE WIDTH: 324 +30nsec. (e) REPEATER LINE SIGNAL PULSE OVER SHOOT: 10 to 30 percent of pulse height, 20 percent nominal. (f) REPEATER LINE SIGNAL PULSE RISE AND FALL TIME: 100nsec maximum. (g) INPUT PORT IMPEDANCE: 100 ohms nominal at 722kHz. (h) RECEIVE LINE BUILD-OUT: Automatic, 0.0 to 35dB. (i) (j) 7.2 Physical AC LONGITUDINAL IMMUNITY: 1000MA peak-to-peak. : Per TR TSY 000057. See Table 2 for the physical characteristics of the unit. Table 2. Feature U.S. Metric Height 2.59 inches 6.58 centimeters Width 0.76 inches 1.93 centimeters Depth 6.0 inches 15.24 centimeters Weight 5.5 ounces 156 grams Temperature 40 to 149F 40 to 65C