IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation



Similar documents
StruxureWare Power Monitoring 7.0.1

StruxureWare Power Monitoring Expert 7.2

StruxureWare Power Monitoring Expert 7.2

Event Notification Module TM

PowerLogic ION Enterprise 5.6

Power Monitoring Expert 7.2

PowerLogic ION Enterprise 6.0

StruxureWare Power Monitoring 7.0.1

StruxureWare Power Monitoring Expert 7.2

StruxureWare Power Monitoring Expert - Data Center Edition

StruxureWare Power Monitoring Expert 7.2

Configuring security in ION devices using ION Setup

PowerLogic ION Enterprise 6.0

StruxureWare Power Monitoring Expert - Data Center Edition

StruxureWare Power Monitoring Expert 8.0

UPS System Capacity Management Configuration Utility

StruxureWare Power Monitoring Expert Data Center Edition

WinPM.Net 6.0. User Guide

WinPM.Net 3.2. Commissioning Guide

StruxureWare Power Monitoring 7.0

StruxureWare Power Monitoring In-Place Upgrade Guide SQL Server Standard Edition Only

Instruction Bulletin Retain for future use. POWERLOGIC SMS 4.0, SU1 System Manager Software Setup Guide

Historian SQL Server 2012 Installation Guide

PowerLogic ION Setup 3.0

Wonderware Information Server Installation Guide

About This Manual. 2 About This Manual

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015

Solution: Delete global.log. You will have to re-add a Global Event Viewer if that is something you want to use in your upgraded system.

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

IMPORTANT: The person who installs and sets up the PCS Axis database on the central database server

Immotec Systems, Inc. SQL Server 2005 Installation Document

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

NVivo Server 10 R2 INSTALLATION AND SET UP GUIDE

INSTALLATION AND SET UP GUIDE

StruxureWare Power Monitoring 7.0. Side By Side Upgrade Guide For Distributed Systems

for Networks Installation Guide for the application on the server July 2014 (GUIDE 2) Lucid Rapid Version 6.05-N and later

for Networks Installation Guide for the application on the server August 2014 (GUIDE 2) Lucid Exact Version 1.7-N and later

Installation & Upgrade Guide. Hand-Held Configuration Devices Mobility DHH820-DMS. Mobility DHH820-DMS Device Management System Software

UNICORN 7.0. Administration and Technical Manual

Microsoft Corporation. Project Server 2010 Installation Guide

Installing Management Applications on VNX for File

Install SQL Server 2014 Express Edition

Windows SharePoint Services Installation Guide

PowerLogic ION7550 / ION7650

Andover Continuum web.client Planning and Installation Guide for Version 1.92

TROUBLESHOOTING GUIDE

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

File Auditor for NAS, Net App Edition

Getting Started. Symantec Client Security. About Symantec Client Security. How to get started

UNICORN 6.4. Administration and Technical Manual

Installation Instruction STATISTICA Enterprise Server

3M Command Center. Installation and Upgrade Guide

4.0 SP1 ( ) November P Xerox FreeFlow Core Installation Guide: Windows Server 2008 R2

NeuralStar Installation Guide

Migrating MSDE to Microsoft SQL 2008 R2 Express

Site Monitor. Version 5.3

How To Manage Storage With Novell Storage Manager 3.X For Active Directory

Setting Up SSL on IIS6 for MEGA Advisor

SQL EXPRESS INSTALLATION...

Networking Best Practices Guide. Version 6.5

WhatsUp Event Analyst v10.x Quick Setup Guide

Before deploying SiteAudit it is recommended to review the information below. This will ensure efficient installation and operation of SiteAudit.

WhatsUp Gold v16.2 Installation and Configuration Guide

System Manager Software Installation Notes

Pro-Watch Software Suite Installation Guide Honeywell Release 4.1

GP REPORTS VIEWER USER GUIDE

NTP Software File Auditor for Windows Edition

Kaseya Server Instal ation User Guide June 6, 2008

Skynax. Mobility Management System. System Manual

Burst Technology bt-loganalyzer SE

Diamond II v2.3 Service Pack 4 Installation Manual

Modbus and ION Technology

Pro-Watch Software Suite Installation Guide Honeywell Release 3.81

INSTALLATION GUIDE. Snow License Manager Version 7.0 Release date Document date

WhatsUp Gold v16.1 Installation and Configuration Guide

Automation License Manager

Microsoft SQL 2008 / R2 Configuration Guide

BlackBerry Enterprise Service 10. Version: Configuration Guide

Installation Guide 3.0

Secret Server Installation Windows 8 / 8.1 and Windows Server 2012 / R2

VITAL SIGNS Quick Start Guide

Upgrade Guide BES12. Version 12.1

Sage Timberline Enterprise Installation and Maintenance Guide

2014 Electrical Server Installation Guide

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

Vijeo Historian Installation and Configuration Guide. July 2012

WhatsUp Gold v16.3 Installation and Configuration Guide

Avaya Video Conferencing Manager Deployment Guide

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Release Notes: SANsymphony-V System Center Operations Manager (SCOM) Management Pack 1.3

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Installation Notes for Outpost Network Security (ONS) version 3.2

Step-By-Step Guide to Deploying Lync Server 2010 Enterprise Edition

LifeSize Control TM Deployment Guide

NETWRIX EVENT LOG MANAGER

Transcription:

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation 7EN02-0362-01 06/2015 IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation This document is designed to help aid in the preparation of the information technology (IT) infrastructure for hosting a Power Monitoring Expert 8.0 system. In this document Safety information...2 Important information... 2 Please note... 2 Safety Precautions...3 Installation Requirements...4 Required software...4 Windows operating systems... 4 SQL Server editions... 4 Pre-Installation Checks...5 Installer Actions...5 Windows Server Configuration...7 IIS Configuration...7 SQL Server...7 Power Monitoring Expert Windows Services... 10 Ports... 12 Additional information StruxureWare Power Monitoring Expert 8.0 Installation Guide StruxureWare Power Monitoring Expert 8.0 User Guide Schneider Electric 35 Rue Joseph Monier 92500 Rueil Malmaison France www.schneider-electric.com ION, ION Enterprise, Modbus, Modicon, PowerLogic and Schneider Electric are trademarks or registered trademarks of Schneider Electric in France, the USA and other countries. Other trademarks used are the property of their respective owners. This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations. As standards, specifications and designs change from time to time, always ask for confirmation of the information given in this publication.

Schneider Electric IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Safety information Important information Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. Please note Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction, installation, and operation of electrical equipment and has received safety training to recognize and avoid the hazards involved. Page 2

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Schneider Electric Safety Precautions During installation or use of this software, pay attention to all safety messages that occur in the software and that are included in the documentation. The following safety messages apply to this software in its entirety. UNINTENDED EQUIPMENT OPERATION WARNING Do not use the software for critical control or protection applications where human or equipment safety relies on the operation of the control action. Do not use the software to control time-critical functions because communication delays can occur between the time a control is initiated and when that action is applied. Do not use the software to control remote equipment without securing it with an authorized access level, and without including a status object to provide feedback about the status of the control operation. Failure to follow these instructions can result in death or serious injury. INACCURATE DATA RESULTS WARNING Do not incorrectly configure the software, as this can lead to inaccurate reports and/or data results. Do not base your maintenance or service actions solely on messages and information displayed by the software. Do not rely solely on software messages and reports to determine if the system is functioning correctly or meeting all applicable standards and requirements. Consider the implications of unanticipated transmission delays or failures of communications links. Failure to follow these instructions can result in death, serious injury, equipment damage, or permanent loss of data. Page 3

Schneider Electric IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Installation Requirements Required software Windows operating systems Installing Power Monitoring Expert software is a complex operation that installs and configures Power Monitoring Expert components as well as components of the Windows Server operating system and SQL Server. The following information describes the software requirements for Power Monitoring Expert software. You can install Power Monitoring Expert software on servers using any of the following Windows operating systems: Windows 7 Professional/Enterprise, SP1 Windows 8.1 Professional/Enterprise Windows Server 2008 R2 Standard/Enterprise, SP1 Windows Server 2012 Standard Windows Server 2012 R2 Standard SQL Server editions NOTE: Power Monitoring Expert software can be installed on servers in a domain environment; however, it cannot be installed on domain controllers. If Power Monitoring Expert software is installed on a server that is subsequently changed to a domain controller, the software ceases to function correctly. If no supported SQL Server version is detected during the installation of Power Monitoring Expert on a Standalone Server, then SQL Server 2014 Express is installed. If a supported edition of SQL Server Express is already installed but not configured with a database instance for use with Power Monitoring Expert, the installer adds the required database instance. Otherwise, one of the following SQL Server editions needs to be installed prior to installing Power Monitoring Expert software. Note that supported 32-bit and 64-bit SQL Server editions can only be installed on supported 32-bit and 64-bit Windows operating systems, respectively. For example, a 32-bit SQL Server edition is not supported on a 64-bit Windows operating system. Page 4

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Schneider Electric SQL Server Editions Standalone Server Distributed Database Server SQL Server 2008 R2 Express, SP3 Yes No SQL Server 2012 Express, SP2 Yes No SQL Server 2014 Express Yes No SQL Server 2008 R2 Standard/Enterprise, SP3 Yes Yes 1 SQL Server 2012 Standard/Enterprise/Business Intelligence, SP2 Yes Yes 2 SQL Server 2014 Standard/Enterprise/Business Intelligence Yes Yes 2 1 Supported for a distributed database server configuration on Windows Server 2008 R2 Standard/Enterprise SP1. 2 Supported for a distributed database server configuration on Windows Server 2012 Standard, and on Windows Server 2012 R2 Standard. Pre-Installation Checks Depending on your operating system version, your SQL Server edition, and the setup type (server or client) that you select for installation, the Power Monitoring Expert Installer performs some or all of the following tasks prior to the installation of the software: Checks for.net Framework 4.5.2 and automatically installs it if required. Installs Power Monitoring Expert 8.0. If a previous version of the software is installed, the Installer checks to make sure that it can be upgraded. Verifies that the SQL Server Agent is installed. Validates that a supported SQL Server edition and service pack level are installed. Verifies the connection to the SQL Server. Checks the Database location. The Database must be local for some installation types and remote for others (local for standalone and remote for Primary server). Checks for 32-bit SQL Server edition. Checks for the presence of ASP.NET. Verifies that the appropriate account permissions are defined, for example, that the SQL Server system administrator (sa) account is set with Administrator as the user. Verifies that the Windows account that the SQL Server service runs under has the proper folder permissions to proceed. Installer Actions The Installer performs configuration tasks during the installation process. Some of those tasks include the following: Installs SQL Server backwards compatibility. Configures the SQL Server Agent. Page 5

Schneider Electric IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Configures ASP.NET. Configures SQL Server. Registers and starts the Power Monitoring Expert Services. Installs and configures Internet Information Services (IIS). Installs Schneider Electric License Manager, Schneider Electric Floating License Manager, and trial licenses. To view all of the actions performed by the Installer, see the Installation log that is available at the conclusion of the installation process. The log is located in the Schneider Electric/Power Monitoring Expert/SetupLogs folder. Page 6

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Schneider Electric Windows Server Configuration The Power Monitoring Expert Installer must run under a local system administrator account. During installation, the Installer makes changes to the Windows Server hosting Power Monitoring Expert applications. The following two standard Windows accounts are created: IONUser and IONMaintenace. Both accounts have their passwords set to factory configured values, and the passwords are set to never expire. IONUser is used to run report subscriptions. If the subscription involves writing to a file share, the IONUser account requires write permissions to that folder. IONMaintenance is used for periodically running SQL maintenance jobs against the Power Monitoring Expert databases. If a Domain Password Policy is in effect, the preset passwords for IONMaintenance and IONUser may not be compliant. IIS Configuration During installation, IIS is installed and configured to host various Power Monitoring Expert Web applications. IIS Configuration Application Pool Application Modules App Pool Application EWS HierarchyManager RateEditor SystemDataService Trends TrendsWebService Web ION App Pool AlarmConfiguration ION ION/diagrams IONReportDataService WebServices WebReporterAppPool Web Reporter SQL Server Power Monitoring Expert requires SQL Server to host several databases. Page 7

Schneider Electric IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation During installation, SQL Server and SQL Agent must be running under the NT Authority\System (also known as the Local System account). These permissions are needed to allow for the creation of databases in the Program Files directory and to write to the current log in the user s Temp directory. Several logins are created in SQL Server as part of the installation process. SQL Logins Logins Authentication Roles User Mapping AMUser SQL Public ApplicationModules ION SQL Public, sysadmin ION_Data, ION_Network, ION_SystemLog, ApplicationModules ionedsd SQL Public ION_Data, ION_Network ionedsd SQL Public ION_Data IONMaintenance Windows Public ApplicationModules, ION_Data, ION_Network, ION_SystemLog Application Modules Database This database contains all of the configuration data for the Dashboards and Tables applications. User AMUser IONMaintenance Membership AMApplicationRole db_backupoperator, db_ddladmin, Maintenance ION Data Database This database contains the logged historical data events and waveforms. User Report Ionedsd Report IONMaintenance Membership Db_datareader, ION_Reader ION_DSD_Reader Db_datareader, ION_reader db_backupoperator, db_ddladmin, Maintenance Page 8

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Schneider Electric ION Network Database This database contains device communications information and general Power Monitoring Expert settings. Users Ionedsd IONMaintenance Memberships NOM_DSD_Reader db_backupoperator, db_ddladmin, Maintenance ION System Log Database This database contains Power Monitoring Expert events that occur during the operation of the software. Users IONMaintenance Memberships db_backupoperator, db_ddladmin, Maintenance Page 9

Schneider Electric IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Power Monitoring Expert Windows Services Power Monitoring Expert uses the following Windows services: Service PME ION Alert Monitor ION Component Identifier Service ION Connection Management Service ION Event Watcher Service ION Log Inserter Service ION Managed Circuits ION Network Router Service ION OPC Data Access Server ION PQDIF Exporter Service ION Query Service ION Real Time Data Service Description Checks the computer s communications ports continuously for high priority events occurring at remote modem sites. When a high priority event happens, Alert Monitor initiates a communications connection to the remote modem site. Locates local and remote product components. Although this service is configured as Manual, the service starts when the client attempts to connect to it. Determines the connection status of sites and devices in the system, and handles allocation of resources such as modems. This service manages the state of site and device connectivity for the system. To establish the most appropriate state for the system, each connect and disconnect request is evaluated against the overall state of the system and availability of communications channels. Monitors system events for conditions specified in Event Watcher Manager. Provides historical data collection and storage for your power monitoring system. See the "Log Inserter" topic in the Database Manager and Windows Task Scheduler chapter of the StruxureWare Power Monitoring Expert 8.0 User Guide. Creates individual real-time and historical data sources for multi-circuit meters. Routes all information between the software components, such as client workstations, and the Log Inserter. The service dynamically detects changes to the network configuration including the addition of new servers. It can also recognize new software nodes, such as Vista, that are added to an existing server. Manages and is responsible for supplying OPC data to client applications. Although this service is configured as Manual, the service starts when the client attempts to connect to it. Translates data from the product's databases to PQDIF file format and manages scheduled PQDIF exports. Provides historical data retrieval for your powermonitoring system. See the "Linking a Data Log Viewer or Event Log Viewer" topic in the Vista chapter of the StruxureWare Power Monitoring Expert 8.0 User Guide. Manages and provides access to real time data from the power management system. Page 10

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Schneider Electric Service ION Report Subscription Service ION Site Service ION Virtual Processor Service ION XML Subscription Service ION XML Subscription Store Service ApplicationModules CoreServicesHost ApplicationModules DataServicesHost ApplicationModules ProviderEngineHost ION Software Alarm Service Description Manages report subscriptions in the Reports application. (This service is only available if you are using a supported edition of SQL Server Standard or Enterprise with the software product.) Manages communication links to and from the product. ION Site Service is responsible for handling packet communications to system devices and controlling direct device communications. The service reacts to changes in network configuration. For example, often changes to certain channels, configuration parameters, ports, or device parameters can interrupt a connection. You can add, delete, or change channels, configuration parameters, ports, and devices without restarting the ION Site Service, the ION Network Router Service, and the ION Connection Management Service. Provides coordinated data collection, data processing, and control functions for groups of meters. See the "Virtual Processor setup" topic in the Management Console tools chapter of the StruxureWare Power Monitoring Expert 8.0 User Guide. Manages subscriptions to XML data for Vista user diagrams. This service is used only by the Diagrams application. When you open a Vista user diagram in a web browser, the ION XML Subscription Service creates a subscription and delivers the real-time data in XML format. Stores XML data subscriptions for the power monitoring devices on the network. This service is used only by the Diagrams application. Hosts common web services used by the Web Applications component. Hosts web services that provide low-level access to system data for the Web Applications component. Hosts web services that provide data processing for the Web Applications component. Hosts the mechanism to perform software server based alarm monitoring and generation. Page 11

Schneider Electric IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation Ports Depending on the Power Monitoring Expert configuration and the desired features, some or all of the ports listed below may be required. Note: All ports are TCP ports. Power Monitoring Expert does not use UDP. Power Monitoring Expert uses the following ports: Port Number Used For 23 Telnet (used for meter diagnostics) 25 (Required for email communications) 502 Modbus TCP 3721 Ethernet access for the 3720 ACM meter 7700 ION 7701 Modbus RTU 7800 EtherGate simultaneously through available COM ports 7801 EtherGate through the meter's COM1 7802 EtherGate through the meter's COM2/COM4 7803 EtherGate through the meter's COM3 13666, 13670 Power Monitoring Expert services use these ports. These ports are used if a client machine needs to access the Designer and/or Vista components of Power Monitoring Expert. 13668 This port is used when the Power Monitoring Expert system contains a Secondary Server. 1433 SQL Server uses this port. (1) 1434 Microsoft SQL Monitor uses this port to identify named database instances. 139 NetBIOS and Windows File and Printer Sharing use this port. 80 HTTP (required for Diagrams, Reports and Internet access) uses this port. The EWS server also use this port. 57777 Real-time Data Service uses this port to transfer real-time data to Power Monitoring Expert clients. (2) SQL Server uses this port if you use the default instance when you install Power Monitoring Expert. If you use a named instance when you install Power Monitoring Expert, it is recommended that you configure the named instance to use port 1433. You can configure the ION Real Time Data Service to use a different port. 27000 Software licensing. An alternate port can be used if port 27000 is unavailable. Page 12