Next Generation 100G Client Optics



Similar documents
Trends In Data Rate And Link Length In Evolving Optical Standards

The Ethernet Roadmap Applications, servers, optics, and switches

Latest Trends in Data Center Optics

Enabling the Business Continuity & Change the way business communicates

Low Cost 100GbE Data Center Interconnect

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

Evolution of Ethernet Speeds: What s New and What s Next

Pluggable Optics for the Data Center

100 GBE AND BEYOND. Greg Hankins NANOG52. Diagram courtesy of the CFP MSA. NANOG /06/14

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Advanced Modulation Formats in Data Centre Communications Michael J. Wale Director Active Products Research

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems

The ABC of Direct Attach Cables

How To Make A Data Center More Efficient

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

Intel Ethernet SFP+ Optics

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

100 GIGABIT ETHERNET TECHNOLOGY OVERVIEW & OUTLOOK. Joerg Ammon <jammon@brocade.com> Netnod spring meeting 2012

Objective Considerations: Given Today s Data Center Environment

GIGABIT ETHERNET. Greg Hankins UKNOF16. v /04/22

25G SMF Optics for Next Generation Enterprise / Campus / Data Centre Applications. Kohichi Tamura, Oclaro. Peter Jones, Cisco

100 Gb/s Ethernet/OTN using 10X10 MSA Optical Modules

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Next Generation FTTH Chris Pfistner ECOC 2011

White Paper. An Overview of Next-Generation 100 and 40 Gigabit Ethernet Technologies

Volume and Velocity are Driving Advances in Data Center Network Technology

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

Implementation of Short Reach (SR) and Very Short Reach (VSR) data links using POET DOES (Digital Opto- electronic Switch)

Parallel SMF (PSM) in the Data Centre

Cisco SFP Optics for Gigabit Ethernet Applications

Data Center Cabling Technology and Trends

Wavelength Division Multiplexing

10G and Beyond in the Data Center with OM3 Fiber

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

HIGH QUALITY FOR DATA CENTRES ACCESSORIES AND INFRASTRUCTURE. PRODUCT CATALOG 12/2014 PRO-ZETA a.s.

Features and Benefits

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

SFP Transceiver Specifications

CISCO 10GBASE X2 MODULES

BROCADE OPTICS FAMILY

Cisco 10GBASE SFP+ Modules

Active Optical Cables for InfiniBand QDR and FDR. SC11 Seattle, WA

Optics Technology Trends in Data Centers

XFP Optical Receiver, 80km Reach

Bandwidth analysis of multimode fiber passive optical networks (PONs)

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

Introduction to Optical Link Design

LONGLINE 2km XFP Optical Transceiver

Georgia Tech 100G Center

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

Data Center Design for 40/100G

Recession-Proof Consulting Services with CWDM Network Design

Your Network. Our Connection. 10 Gigabit Ethernet

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

The Fraunhofer Heinrich Hertz Institute

Attaching the PA-A1-ATM Interface Cables

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

4.25Gbps SFP Optical Transceiver, 30km Reach

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

LONGLINE 40km XFP Optical Transceiver

Ligent intelligent photonics. a global leader in transceiver technology

Arista 40G Cabling and Transceivers: Q&A

802.3bj FEC Overview and Status. 400GbE PCS Options DRAFT. IEEE P802.3bs 400 Gb/s Ethernet Task Force. November 2014 San Antonio

Optoelectronics Portfolio Product Selection Guide

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Overcoming OM3 Performance Challenges

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

CWDM: lower cost for more capacity in the short-haul

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

X2 LR Optical Transponder, 10Km Reach

155Mbps DFB SFP Optical Transceiver, 120km Reach

Ethernet 102: The Physical Layer of Ethernet

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

Model GS Port Node 1 GHz with 40/52 MHz split

BV-10 Performance Endpoint Unit PERFORMANCE DEMARCATION FOR NETWORK-WIDE VISIBILITY

Cisco ONS Port and 4-Port Small Form-Factor Pluggable-Based Multirate Optics Card

Designing Fiber Optic Systems David Strachan

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Global Networking Services

Transcription:

Next Generation 100G Client Optics 100G and Beyond in ITU-T and IEEE Workshop 13, ECOC 2011 Geneva, Switzerland 18 September 2011 Chris Cole chris.cole@finisar.com

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 2

ITU-T & IEEE 100G Client Optics Optics designation 100m 1000m 2km to 10km primary application(s) high density data center * 2km telecom optics min loss budget is 4dB 18 September 2011 3 structured data center telecom & general data center ~loss budget 2dB 2.5dB 6dB* ~link budget = loss + penalties 8dB 3dB 8dB bit/sec cost & power target ~10GE-SR ~10GE-SR ~10GE-LR volume laser technology VCSEL PIC TBD DFB PIC fiber parallel MMF duplex SMF duplex SMF Existing standard 100GE-SR10 none G.959.1 100GE-LR4 Next Gen standard 100GE-SR4 100GE-nR4??? none???

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 4

100G Parallel MMF Existing Optics 18 September 2011 5

100G Parallel MMF Next Gen Optics Long term, high volume architecture 18 September 2011 6

100G Parallel MMF Key Technology High yield Photonic Integrated Circuit (PIC*) parallel quad VCSEL array Ex. monolithic GaAs quad 850nm VCSEL array, 0.25mm x 1.0mm PIC, Finisar Corp. * The C in PIC is a stretch since there are no optical connections. 18 September 2011 7

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 8

1000m Structured Optical Link Application Majority of 10G data center optics are 10GE-SR 10GE-SR VCSEL technology has significantly lower cost & power than 10GE-LR DFB laser technology 10GE-SR 300m reach covered 99% of data center links when adopted in 2002, and still covers majority of links today Since 2002, the appearance of Internet Data Centers (IDCs) with link reach requirements >300m created a need for new 10G optics: structured link reach up to 1000m @ ~10GE-SR bit/sec cost Similar 40G and 100G structured optics are needed or will be needed 100GE-SR10 and 100GE-SR4, using parallel VCSEL Arrays and MTP connectors, are not practical for >300m links 100GE-LR4, using DFB PICs, exceeds 10GE-SR bit/sec cost & power Large difference between 1000m structured and 10km general optics link budgets (>6dB) offers opportunities for new technologies 18 September 2011 9

1000m Structured Optical Link Definition What is a 1000m structured data center optical link? 1000m or shorter duplex SMF link with a pre-defined fixed number of connectors; similar to structured duplex or parallel MMF links Does not support large number of connectors or optical loss elements like passive cross-connect or power splitters Example structured links from presentation by Paul Kolesar (CommScope), Fiber Cabling Trends in Data Centers during 802.3 Next Gen 100G PMD Study Group, Chicago, Il, 14 Sept. 2011 18 September 2011 10

1000m Structured Optical Link Next Steps Optics technologies TBD 100GE-LR4 WDM cooled 4x25G DFB PIC (reference baseline) un-cooled CWDM 4x25G DFB PIC (unlikely to be compelling) Si 4x25G modulator PIC InP 4x25G modulator PIC Long Wave 4x25G VCSEL PIC other Market potential and volume timeline TBD Exact reach TBD IEEE may not find sufficient justification for a 1000m structured optics standard (100GE-nR4), either because of insufficient market volume or immature optics technology 18 September 2011 11

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 12

2km Telecom Optics Use 40G 2km telecom optics link budget ATT China Telecom Deutsche Telekom NTT Sprint Verizon 6dB deployed (4dB loss budget) 7dB preferable (5dB loss budget) 4dB sufficient for all links Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No Source: 100Gb/s SMF Client Reach Specs presentation during Next Gen Optical PMD CFI Discussion, 11/8/10, Dallas, TX All deployed 10G & 40G 2km telecom optics have 4dB min loss budget 100G 2km telecom optics application is the same as 40G application 100G 2km telecom optics cost target: ~10GE-LR bit/sec 18 September 2011 13

2km Telecom Optics Implementation 10GE-LR 10km general optics have 6.2dB loss and 9.4dB link budgets OC-192 SR-1 2km telecom optics have 4dB loss and 5dB link budgets Volume of the two 10G applications is similar Early SR-1 single rate 300-pin modules have been replaced by pluggable dual rate modules which meet both specifications Despite large link budget difference, lower cost of 2km telecom optics does not justify dedicated SR-1 single rate 10G pluggable modules 40G is now the same; 40GE-LR4 WDM tri-rate modules are the lowest cost 40GBASE, STM-256 and OTU3 client optics 100G is also the same; 100GE-LR4 WDM dual-rate modules will be the lowest cost 100GBASE and OTU4 client optics IEEE is not likely to find justification for a 100G 2km 4dB loss optics standard, because it splits volume and increases OpEx support cost 18 September 2011 14

100G WDM Duplex SMF Existing Optics G.959.1 4I1-9D1F is corresponding ITU-T optical specification 18 September 2011 15

100G WDM Duplex SMF Next Gen Optics G.959.1 4I1-9D1F is corresponding ITU-T optical specification 18 September 2011 16

100G WDM Duplex SMF Key Technology High yield Photonic Integrated Circuit (PIC) WDM quad DFB array Ex. monolithic InP quad 1310nm band DFB laser array with AWG, 1.1mm x 2.4mm PIC, CyOptics Inc. 18 September 2011 17

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 18

FEC in Next Gen 100G Client Optics IEEE 802.3 Next Generation 100G Study Group is investigating using FEC for 100G Client Optics Baseline I/O to support standard specifications Extended I/O with FEC to support enhanced specifications: extended electrical or optical performance such as reach reduced cost through simplified design and testing (ex. no low BER specifications and measurements) Auto Negotiation can be used to revert to baseline Electrical I/O MMF optics SMF optics baseline (ex. CAUI-4) extended w/ FEC (ex. CAUI-4f) 100GE-SR4 100GE-SR4f 100GE-LR4 100GE-LR4f 18 September 2011 19

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 20

Summary IEEE 802.3 Next Generation 100G Study Group is investigating the following new 4x25G optics: 100m parallel MMF (100GE-SR4) high density data center optics standard 1000m duplex SMF (100GE-nR4) structured data center optics standard 10km duplex SMF general data center optics lower cost & power alternative to existing 100GE-LR4 DFB based standard IEEE 802.3 Next Generation 100G Study Group is investigating the following new 4x25G electrical I/O: CAUI-4; w/ & w/o FEC standard CPPI-4; w/ & w/o FEC, w/ & w/o EDC standard 18 September 2011 21

Outline ITU-T & IEEE 100G Client Optics 100m High Density Data Center Optics 1000m Structured Data Center Optics 10km General Data Center Optics FEC Summary Appendix: Non ITU-T & IEEE 100G Client Optics 18 September 2011 22

Non ITU-T & IEEE 100G Client Optics 2km 10x10G MSA Rev2.2 Spec 10km 10x10G MSA Rev2.2 Spec rate Gb/s 100 100 reach km 2 10 fiber duplex SMF duplex SMF λ nm 1550 1550 penalties db 2.5 3.0 loss budget db 2.6 5.0 link budget db 5.1 8.0 10x10G MSA 2km spec is not per ITU-T and IEEE methodology: loss is below widely deployed 4dB min 10x10G MSA 10km spec is not per ITU-T and IEEE methodology: loss is below widely deployed 6dB min 1550nm λ penalties are too low and not interoperable 10x10G MSA client specs created: end user confusion need for translation to ITU-T and IEEE methodology designations to prevent improper deployment 18 September 2011 23

Non ITU-T & IEEE 100G Optics Use Chart ` 10x10G MSA Rev2.2 Spec ITU-T & IEEE methodology Optics designation & reach 2km 1000m claimed application(s) telecom central office & structured data center structured data center 2.6dB loss budget supports claimed apps? no yes 2.5dB penalties interoperable over claimed reach? yes yes Optics designation & reach 10km 2km claimed application(s) general data center telecom central office & structured data center 5dB loss budget supports claimed apps? no yes 3dB penalties interoperable over claimed reach? no yes 18 September 2011 24