Monitoring. STULZ The natural choice. Around the clock Around the world

Similar documents
Precise, Reliable and Innovative Air Conditioning for Information and Communication Technology

IT Cooling Solutions. STULZ AirModulator, AirBooster and AirBooster Pro. Air Flow Management for Data Centres

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

STULZ the natural choice. Tel-Air-2 Series. Telecom Line

IT Cooling Solutions. Wall-Air Series Displacement Evolution. Telecom-Line

Data Centre Cooling: Don't Waste Money on the Wrong Solution

Premium Server Client Software

pco sistema... communication Technology & Evolution

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

IT Cooling Solutions. CyberAir 2 Precision Cooling Solutions. Making more efficient use of your resources

Local PlantVisor. PlantWatch. Remote PlantVisor

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Process Alarm Solutions

OPENweb. Efficient controlling at the highest level.

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

API Marine. BMS Presentation. Ballast Measurement Systems

minova technology electronics

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

DCS Data and communication server

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Temperature & Humidity SMS Alert Controller

Engineering and service software For KNX and LPB plants

Communication and connectivity the ideal solution for integrated system management and data integrity

IT Cooling Solutions. Precision Cooling Solutions. Maximum efficiency in data centre air conditioning

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Technology & Evolution

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

Communication Interface Units. CIU Prime & CIU Plus

Smart Integration of Wireless Temperature Monitoring System with Building Automation System

Appendix for Tx5xx and P85x1 manuals

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Ultimate Server Client Software

SiteManager. Air-Site s advanced facility management system

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

User s Manual. Management Software for ATS

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions

SCADA and Monitoring for Solar Energy Plant

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

Current Monitoring Kit QUICK START GUIDE

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Rosemount TankMaster So advanced that it s easy to use

Current Monitoring Kit

ControlMaestro and. BACnet integrated solution

IntesisBox. Making Building Automation go further. OPC Servers

Supporting ANY PRODUCT employing

Modbus Server SAMSUNG Air Conditioners

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

Temperature & Humidity Control Systems for the Wine Industry

Designed for the needs of automation, telecommunications, remote supervision, and monitoring

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

SMS GSM Alarm Messenger

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Thermal Centers Monitoring. Offer of converters TRM102, TRM202, TRM112, TRM212 and additional options.

BS 7 SIS Safety Information System Green Light for Your Production

Computer Automation Techniques. Arthur Carroll

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5


Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

AutoLog ControlMan. Remote Monitoring & Controlling Service

SYSTEMS CALL CENTER GLOBAL RETAIL SOLUTION XWEB5000 XCENTER XWEB3000 XWEB500 - XWEB500D XWEB300D

A Real Time, Object Oriented Fieldbus Management System

User Manual WatchPower

Electronic Control Devices The European Product Catalogue 2007

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: NIS Ingenieurgesellschaft mbh lndustriestr Alzenau Germany

The best network information. COPA-DATA know-how: SNMP with zenon

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IntesisBox Modbus Server SAMSUNG Air Conditioners

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere

High Performance Access Control and Integrated Security Systems

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Application Note Room Alert

DCS110 CATVisor COMMANDER

Medical Vacuum Systems-PXMI

NortechCommander Software Operating Manual MAN R6

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

The software beyond the climatic. Environment simulation

EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014

Operating Software Service Tool

THE SNMP PROTOCOL THE SNMP REQUEST MIB SATELLAR 2DS/20DS SIMPLE NETWORK MANAGEMENT PROTOCOL SATELLAR MANAGEMENT WITH SNMP GET AND SET SMART RADIO

S4000TH HART. HART Communication Manual

The IBS Single Port represents Controlware s latest generation of backup products. IBS Single Port ISDN. access_the_world

GSM GATEWAY PRI / E1 RACK 3U

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Application & Quick-Start Guide

3D MultiVision SOFTWARE OPERATING INSTRUCTIONS

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

RiMONITOR. Monitoring Software. for RIEGL VZ-Line Laser Scanners. Ri Software. visit our website Preliminary Data Sheet

Wireless Solutions BROCHURE

Remote monitoring & control solutions for cathodic protection rectifier

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Master & Amplifier For ModuSat Communal Heating

1. Introduction Fixture exterior view Connecting the Robe Universal Interface Software update of the fixture...

Transcription:

Monitoring STULZ The natural choice Around the clock Around the world

Stulz Monitoring System Security for air conditioning systems CompTrol Microcontroller For the control and monitoring of Stulz precision air conditioners Tele CompTrol Software For central monitoring in BUS and modem version Interface Solutions For connecting to building management systems 2

CompTrol CompTrol Microcontroller Precision Control for Precision Environments CompTrol 1002 CompTrol 5000 / 6000 The STULZ C1002 microcontroller is a complete control and regulation system for air conditioners. - Adjustment of the set points, regulation parameters, system configurations and alarm parameters - Alarms are displayed visually until reset - Protection of all data in the event of a power failure - User friendly - Can be connected to STULZ monitoring systems and other building management systems The STULZ C5000 / C6000 microcontrollers are used to operate, regulate and monitor the entire air conditioning system. The C5000 / C6000 microcontroller has the following features: - Simple, user-friendly prompts - Large LCD display and LEDs for the display of data and operating status - Graphic display of temperature and humidity over the last 24 hours - Interface for PC and printer - Protection of all data in the event of a power failure - Information displayed in plain language - Can be connected to STULZ monitoring systems and other building management systems - A choice of different languages and units of measure for display C6000 only - Flash EPROM as program memory - Control and regulation of up to 6 modules - Sequencing of up to 5 units via bus cable CompTrol 5000 / 6000 Supervisor As an option, a C5000/ C6000 Supervisor with independent temperature and humidity sensors can be used. In the case of failure of the first C5000 / C6000 controller, the Supervisor takes over all necessary functions. 3

Tele CompTrol Tele CompTrol In-House and Remote Monitoring Around the clock Around the world The STULZ Tele CompTrol software makes it possible to centrally monitor more than 900 STULZ air conditioners. - In-house monitoring via a direct bus interface to the units Alarm Messages Incoming alarm messages are indicated by a red alarm window that must be reset by the user. All alarm messages are saved in an alarm log file with all information necessary for their identification. Bus version C5000 + MAX-Board C6000 C1002 - Remote monitoring over the Up to 31 controllers telephone network via modem link to several groups of units - Modem links subdivided into an C5000/6000 + MIB Board alarm channel and a scan channel for maintaining alarm monitoring with simultaneous status querying of further groups of units by the user - Parallel operation of in-house monitoring and remote monitoring RS 485 I RS 485 II - Graphic display of unit status queries - Graphic display of temperature Converter RS 485 / 232 and humidity - Alarm forwarding via SMS RS 232 4

Unit Status Messages The actual status of each individual unit can be queried and displayed via the scan channel. Set points can be changed and alarms reset. The unit status can be queried automatically at intervals between 1 and 24 hours. The status messages are saved in a scan log file during this process and can be used for system analysis. Alarm Forwarding Apart from the output of all incoming alarm messages on a printer, it is possible to forward them per modem. A maximum of 2 forwards can be activated to recipients such as PCs and / or mobile telephones via SMS. Modem C5000/6000 + MIB-Board C5000 + MAX-Board C6000 C1002 RS 232 RS 485 I Modem Up to 31 controllers Modem Alarm channel Modem Scan channel RS 232 5

Interface Interface Solutions Gateways to the World of Building Management Systems Interface with most BMS Systems The STULZ regulator systems facilitate a direct connection to BMSs from various manufacturers. This integration makes it possible for the customer to centrally monitor, control and display STULZ air conditioners. The C5000 / C6000 MIB (Multi Interface Board) is used as the carrier for the gateway between STULZ regulators and BMS. Apart from this gateway developed by STULZ, some BMS manufacturers offer the direct integration of STULZ regulators. Apart from the manufacturerspecific gateways, STULZ offers integration via the ModBus protocol as a standard solution. 6

C5000 + Max Board C5000 + Max Board C6000 C1002 Manufacturer Data Protocol Gateway STULZ Bus System Controller C5000 MIB C6000 MIB Mod-Bus Various manufacturers or RS 485 I Network-Bus P90 RS 485 I SNP Satchwell Ni-Bus PR-Bus METASYS CFE CP524 N2-Bus Unigyr-Bus Sinec L2-Bus 7

Globally close to you. with competent contacts in our STULZ subsidiaries, and the exclusive sales and service partner network worlwide. Our four production plants are in Europe, North and South America. 687 600/5-00b e. IWS. SDM, München STULZ GmbH, Hamburg BR E F GB COSMOTEC do BRASIL INDUSTRIAL LTDA. Member of the STULZ Group Rodovia BR376 km 633 n 2700 83015-000 São José dos Pinhais Paraná Tel.: +55(41)382 01 05 Fax: +55(41)382 13 98 e-mail: stulz.ltda@mais.sul.com.br STULZ ESPAÑA S.A. Paseo de Yeserias 33 28005 Madrid Tel.: +34(91)517 83 20 Fax: +34(91)517 83 21 e-mail: stulz@lycos.es STULZ FRANCE S. A. R. L. 107, Chemin de Ronde 78290 Croissy-sur-Seine Tel.: +33(1)34 80 47 70 Fax: +33(1)34 80 47 79 e-mail: info@stulz.fr STULZ U. K. LTD. First Quarter Blenheim Rd. Epsom Surrey KT 19 9 QN Tel.: +44(1372)74 96 66 Fax: +44(1372)73 94 44 e-mail: sales@stulz.co.uk I I NL USA STULZ ITALIA ENGINEERING S. R. L. Piazza Gramsci 2 20154 Milano Tel.: +39(02)34 23 52 Fax: +39(02)33 14 734 e-mail: stulzita@tin.it COSMOTEC SPA Member of the STULZ Group Via Torricelli, 3 37067 Valeggio sul Mincio (VR) Tel.: +39(045)633 16 00 Fax: +39(045)633 16 35 e-mail: cosmotec@cosmotec.it STULZ GROEP B. V. Industriecentrum Bovenkerk Postbus 75 1180 AB Amstelveen Tel.: +31(20)54 51 111 Fax: +31(20)64 58 764 e-mail: stulz@stulz.nl STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 1572 Tilco Drive Frederick, MD 21704 Tel.: +1(301)620 2033 Fax: +1(301)662 5487 e-mail: info@stulz-ats.com STULZ GmbH Holsteiner Chaussee 283 D-22457 Hamburg Tel.: +49(40)55 85-269 Fax: +49(40)55 85 308 e-mail: products@stulz.de www.stulz.com THE NATURAL CHOICE