INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE



Similar documents
User Manual UNIBLITZ Version VMM-D1 Shutter Driver and VMM-T1 Shutter Driver/Timer

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Research RF Sputtering Packages

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

F(t) Forssell Technologies Inc

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

PERF10 Rubidium Atomic Clock

±15 V Current-Limited Power Supply

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Current Probes. User Manual

9448 Installation and User Guide

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Software Manual RS232 Laser Merge Module. Document # SU Rev A

Line Level Converter Box. S Class Signal Processors

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

PS 155 WIRELESS INTERCOM USER MANUAL

Switch Selection Guide

ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual

INSTRUCTION MANUAL MODEL PCD-88

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Controller Automation, Model II+

Agilent 8762/3/4A,B,C Coaxial Switches

Amplified High Speed Fiber Photodetectors

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

RS - SPM. Serial parallel translator module

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Automatic AES Change-Over

Brushless DC Motor Controller Product Specification Assembly 025F0129

User Manual PT-E-HIP

FIREDEX Conventional Fire Panels

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

TOA 900 SERIES II MIXER POWER AMPLIFIER

Contents. Safety Warnings... 1

User Manual. CFG253 3 MHz Function Generator

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

To Purchase This Item, Visit BMI Gaming Operation Manual

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

DVT913 TV CHANNEL CONVERTER

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

MASTERSOUND. M a s t e r E m o t i o n. PF 100 Limited. Made in Italy

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Product Information Sheet UH28CS-12kV Hi Pot Tester

Unattended Answering Device Instruction Manual

Inductive Proximity Sensors

OPERATING INSTRUCTIONS

LOXONE 12 Channel Amplifier

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Product Information Sheet UH36 Hi Pot Tester

GAE953 Electrical Alarm Unit 19" with Indicator

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

2-Pair HDSL1 Adtran Fiber Optic Link System

LDG DTS-4/4R Desktop Coaxial Switch / Remote

TS510 & TS500. Installation & User Guide. Compatible Equipment

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

ViZion Installation Guide

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

F2400 FOM II Series Fiber Optic Modem Technical Manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

In-Sight Hardware specifications

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

MISE - STEREO ENCODER

VK-250 WARRANTY REGISTRATION FORM

1.44 kw Programmable DC Power Supplies XLN Series

1 All safety instructions, warnings and operating instructions must be read first.

DCS Input/Output Relay Card Series

INTEGRATED CIRCUITS. 74LVC08A Quad 2-input AND gate. Product specification IC24 Data Handbook Jun 30

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Inductive sensor NI10-M18-Y1X-H1141

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Model SPDT Relays

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

LED...A Q Series Sealed High-Intensity

How To Use A Cdm250 Digital Multimeter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

ACS-30-EU-EMDR-10-MOD

Technical Data. back-up time in minutes 100% load % load

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

MS4000/MS4000U Mini-Siren

HVA200 High Voltage Amplifier

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

User s Manual Before using the inverter, you need to read and save the safety instructions.

C220 PRELIMINARY TUBE PREAMPLIFIER SERVICE MANUAL. SERIAL NO. WS1001 And Above C220. Serial Number W S1001 And Above CONTENTS

SL Series AC and DC Electronic Loads

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

WD-AMX Water Detection Controllers

Transcription:

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE VINCENT ASSOCIATES 803 LINDEN AVE. ROCHESTER, NEW YORK 14625 SERVICE/ORDERS (800) 828-6972 In NY State (585) 385-5930 Fax (585) 385-6004 A Division of VA, Inc. Version 2.1 2003

INTRODUCTION The DM412 Drive Module interfaces the smallest aperture shutter in the UNIBLITZ line, the UHS1T2 High Speed Shutter, to the VMM-D1 or VMM-T1 shutter driver units. Operation of the DM412 is simple and straightforward. All activate functions are supplied through the VMM-D1 or VMM-T1 shutter drivers. The only control integral to the DM412 is the NORM\HIGH switch, which allows on-the-fly selection between the normal (NORM) and the (HIGH) speed modes. The CONTROL BNC allows TTL (active low) or remote switch (710R) to electronically select the normal and high-speed modes, providing greater flexibility. MAINTENANCE Although the stability of the timing and drive voltage is assured and calibrated prior to shipment, it may become necessary to make some minor adjustments to the operating systems of the DM412 and the VMM-T1 or VMM-D1 over time. It is highly recommended that if you suspect a problem with your unit that it be returned to the factory for proper adjustments and calibration. The units complicated circuitry will be damaged and/or not function as specified if adjusted improperly. Proper care and maintenance of the unit should be taken as with any electronic instrument. WARRANTY Great care has been taken to ensure that our products are free from defect when shipped. Defective units will be replaced or repaired at no charge, excepting transportation charges, if returned within 90 days from the date of shipment. Vincent Associates will consider the return of unused equipment if returned within 30 days from the date of shipment subject to a 20% restocking charge. This offer does not apply to used or damaged equipment. 2

SPECIFICATIONS Shutter Drive Output (9-Pin Female) Continuously variable frequency o exposures from DC to the shutter s maximum value. Maximum peak pulse power 325W, pulse voltage 65VDC, and pulse current 5A. The DM412 contains two internal drive circuits with the same power spec. Controller Input (7-Pin Male) +65VDC high voltage and +6.75 VDC low voltage power input from VMM-D1 or VMM-T1 controller. Input trigger control and synchronization return amplifier is also provided from the VMM-D1 or VMM-T1 controller. Control Input (BNC) Power Indicator Power Requirements Fuse Requirements Input impedance 10K ohms. Active low. Source current 500µA. Minimum delay time required to ensure mode switching prior to shutter activation 10msec. Red LED indicates when power is applied. Power provided from VMM-D1 or VMM-T1 Controller. See Controller Input specifications. 5x20mm 800mA slow blow fuse for shutter actuator coil protection. Two required, one for each shutter coil. Size (HWD) 1.718 (43.63mm) x 3.558 (90.37mm) x 3.180 (80.77mm) with black textured finish. See dwg. #L- 0172. Cables (included) Cable (optional) #910C - interconnect cable for UHS1T2 High Speed Shutter. #702C - interconnect cable for DM412 Shutter Drive Module. #710R - remote trigger cable. 3

DM412 FRONT AND REAR PANEL OPERATOR CONTROLS DESCRIPTION (Refer to Drawing #L-0173) 1. CONTROL INPUT. BNC active low input. Electrically switches the DM412 between the HIGH and NORMAL speed modes. A low level input places the unit into the NORMAL speed mode. A high level places the unit back to the HIGH speed mode. 2. NORM/HIGH Switch. Allows manual switching between the HIGH and NORMAL speed modes. 3. POWER Indicator. 4. SHUTTER. DM412 9-Pin female connector to mate with 9-Pin male connector of the 10 shutter interconnect cable provided with the control. 5. CONTROLLER. DM412 7-Pin male connector to mate with 7-Pin female connector of the 10 interconnect cable provided with the VMM-D1 or VMM- T1 controller. This cable provides power and control for the DM412 control unit. 6. FUSE B. Replace with 5x20mm 800mA slow blow fuse. 7. FUSE A. Replace with 5x20mm 800mA slow blow fuse. 4

5

OPERATING INSTRUCTIONS After unpacking unit, inspect for any defects. If upon inspection a problem is found, notify Vincent Associates immediately. After initial inspection, the unit is ready for use. Please read the following operating instructions. Improper input/output connections to the unit may cause irreparable damage. The DM412 receives power from VMM-D1 or VMM-T1 driver. Connect the DM412 as per drawing #L-0171. Follow the power up procedure as described in the VMM- D1/VMM-T1 users manual. Once power is on, the DM412 POWER LED will illuminate. Place the NORM/HIGH switch in the NORM position. Place the N.O./N.C. switch (of the VMM-D1 or VMM-T1) to the N.O. position. The shutter will open and remain open until either the N.O./N.C. switch is returned to the N.C. position or the NORM/HIGH switch is returned to the HIGH position. Note, the SYNC LED and the SHUTTER LED (of the VMM-D1 or VMM-T1) will illuminate when the shutter goes to the open position to indicate the presence of a shutter activate signal and that the shutter has opened respectively. In the HIGH-speed mode, a signal to the VMM-D1 or VMM-T1 will trigger the UHS1T2 for 300µsec. only. The shutter cannot be held open in this mode. For example, with the DM412 in the HIGH mode, switching the N.O./N.C. switch to the N.O. position the shutter will open for 300µsec. (typical A - G time). The SHUTTER LED of the VMM-D1 or VMM-T1 will illuminate, however, the SYNC LED will only flash indicating a high-speed exposure. Please note, the typical shutter timing for each of the modes respectively is enumerated in the attached UHS1 data sheet. When operating the UHS1 shutter from a pulse source (through the VMM-T1 or VMM- D1) the minimum pulse width, in the NORM mode, is 600µsec. If the input pulse width in this mode is set to less than 600µsec., the shutter response will be indeterminate. If the input pulse is greater than 600µsec., the shutter will be held open for the duration of the pulse and therefore, in this mode, is programmable. Please note, though the minimum input pulse in the NORM mode is 600µsec., the shutter response (A - G window time) will typically be1.0msec (see UHS1 data sheet for typical timing data). In the HIGH speed mode the shutter exposure is 300µsec (proper exposure pulses are derived within the DM412), regardless of the duration of the input pulses to the VMM-D1 or VMM-T1. Therefore, the minimum input pulse or trigger width, input to the VMM-D1 or VMM- T1, will be as enumerated in the SPECIFICATIONS section of the VMM-D1 or VMM-T1 manual. Please review the Caution section on page #21 in the VMM-D1/VMM- T1 manual for information concerning fuse inspection and replacement. The UHS1 can be operated as any typical shutter in the NORM speed mode. Therefore, the shutter can also be controlled via the RS-232 interface. Please review SYSTEMS OPERATIONS section on page #22 in the VMM-D1/VMM-T1 manual. 6

7

8

1mm diameter aperture Fastest shutter in the UNIBLITZ line of electroprogrammable shutters. 300µsec. total exposure time in the (HIGH) speed mode. 100µsec. rise time. Activated by an electronic pulse through shutter driver module, the DM412, included. Exposure repetition rate continuously variable from DC-400Hz. Non-resonant design allows instantaneous changes in repetition rate and duty cycle in the normal (NORM) mode. No optical surface when open provides 100% transmittance The UHS1 supersedes the LS2 as the fastest shutter in Vincent s UNIBLITZ line. As with the LS series, the UHS1 is specially suited for laser use, with applications including low level chopping, high speed switching, pulse gating and selection, and modulation to 400 Hz. In the high speed mode (HIGH) the UHS1 produces a total exposure pulse of 300µsec! This speed is unprecedented in Vincent type instrumentation shutters. In the normal speed mode (NORM) the shutter is programmable, and activated by an electronic pulse generated by Vincent s drive module, the DM412. This module is included with the UHS1, and will interface with the D122 and T132 controllers. The DM412 converts the specialized shutter drive outputs into the voltage pulses necessary for proper operation of the UHS1. DM412 Drive Module: Operation of the DM412 is simple and straightforward. All activate functions are supplied through the D122 or T132 shutter drivers. The only controls integral to the DM412 are the NORM/HIGH switch which allows on the fly selections between the normal (NORM) and high (HIGH) speed modes. The CONTROL BNC allows TTL (active low) or remote switch (710R) to electronically select the normal and high speed modes, providing greater flexibility. Standard unit (DM412 included) UHS1T2 COIL RES. PULSE VOLTAGE TO OPEN HOLD VOLT. 12 ohms* +65VDC* +5VDC* * (each actuator) WGT. CASED SHUTTER Typical timing values (msec.) using UNIBLITZ drive equipment and measured with UNIBLITZ shutters equipped with standard TEFLON coated TYPICAL PULSE INPUT TO CONTROLLER SHUTTER STATE TYPICAL ELECTRONIC SYNCHRONIZATION OUTPUT FROM CONTROLLER OPERATING TEMP. ABSOLUTE MAX. FREQUENCY OF OPERAT. TIMING OF PULSE INPUT AND SYNCHRONIZATION OUTPUT RELATIVE TO SHUTTER STATE HIGH NORM O-A Delay time on opening after current is applied 0.70 0.70 A-C Transfer time on opening 0.10 0.10 O-C Total opening time 0.80 0.80 B-F Min. equivalent exp. time 0.19 0.89 C-E Min. dwell time with min. input pulse 0.08 0.78 NUMBER BLADES 4.3 oz. (.121 Kg.) 0 C to +80 C 400Hz. 2 For dimension layout to the Ls2/3/6 SHUTTER SPECIFICATIONS sheet FIGURE 1 and FIGURE 2. E-G Transfer time on closing 0.12 0.12 A-G Total window time 0.30 1.00 MET: Min. exposure time 0.80 0.80 TEP: Typical exposure pulse N/A >1.58 The question regarding enhancement of shutter speed with the application of user supplied lubricants has been repeatedly asked. It is our experience that lubricating the shutter blades will actually slow the shutter down and eventually render the shutter inoperable. UNDER NO CIRCUMSTANCES SHOULD ANY TYPE OF LUBRICANT BE APPLIED TO THE SHUTTER BLADE AREA. (Coated blades, future availability) Due to our ongoing product development program, Vincent Associates reserves the right to discontinue or change specifications or designs at any time, without incurring any obligations. Teflon is a registered trade mark of E.I. Dupont U. S. Pat. No. 3.427.576; 3.595.553; 3.967.293. Drawing shown for illustrative purposes only. 11/02 - Printed in U.S.A 803 Linden Ave., Rochester, NY 14625 Tel (585) 385-5930 800-828-6972 Fax (585) 385-6004 E-mail: vincentassociates@uniblitz.com www.uniblitz.com 9