Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best



Similar documents
ADU 5. Automatic Distillation Unit

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Density/Specific Gravity/ Concentration Meter DMA 500

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

Thermal Values. Melting-, Dropping- and Softening Point Simple, fast and reliable

precision glass capillary viscometers

Portable Density/Specific Gravity/Concentration Meter DMA 35

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Compact ph Measuring Instruments

GC-xt. The most flexible GC /GC-MS liquid sample injector

Mitos P-Pump. product datasheet

ORGANIC SAMPLE PREPARATION

INSTRUCTIONS Edition AC

Incubator with mechanical convection

Viscometers. CANNON-FENSKE REVERSE FLOW VISCOMETER TYPE for opaque and transparent liquids

How To Use A Corona Mdi 110

Elemental analyzer multi EA 5000

Specials. designed. 3rd edition 2015 English. for scientists 1

Filtered Prime Yellow Type 1. Centrifuged fatty Grey Type 3. Light orange

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

akku-drive HiClass electronic control for titration and dispensing excellent precision, comfort, flexibility

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

MILESTONE START D. Microwave Digestion System

Amino Acid Analyzer L-8900

LABORATORY.

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION


Anton Paar is the world market leader in the field of density measurement, the determination of dissolved CO 2

Multi-Range Programmable DC Power Supplies 9115 Series

ELECTROMAGNETIC FLOWMETER COMPACT

Viscosity. Test Methods

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Turbine Flow Sensor Series VTR

Viscosity. Desmond Schipper Andrew R. Barron. 1 Introduction

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

Portable digital microprocessor thermometers with interchangeable probes

HFM Heat Flow Meter Thermal Conductivity Analyzer

Vacuum drying oven for non-flammable solvents

LiquiPhysics Excellence

DSC Differential Scanning Calorimeter

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

Measuring Extruders and Extrusiograph. ... where quality is measured.

OPSIS LiquidLINE KjelROC Distillation Unit

Journal bearings/sliding bearings

Multi-Range Programmable DC Power Supplies 9115 Series

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

Variable V Area Flowmeter Rotameter The Original

Pressure regulating valve with modulating kit, type DRV

Overflow valve with thread connection

Melting Point Apparatus

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Discover Your Potential

How To Make A Fronius Cl Power Inverter

Operation Manual For NDJ-8S Digital Rotary Viscometer

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

DENSITY MEASURING SYSTEMS

Introduction to Microfluidics. Date: 2013/04/26. Dr. Yi-Chung Tung. Outline

T U R B I N E G A S M E T E R

Agilent 4338B Milliohm Meter

INVESTIGATION OF FALLING BALL VISCOMETRY AND ITS ACCURACY GROUP R1 Evelyn Chou, Julia Glaser, Bella Goyal, Sherri Wykosky

PARALLEL AUTOCLAVABLE MINI FERMENTERS/ BIOREACTORS

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds.

BR I Blood Bank Refrigerators

TEMPERATURE SENSORS AND PROBES FOR BIO-MEDICAL APPLICATIONS

Density/Specific Gravity Meter

Titrette. class A precision. The next generation Digital Burette!

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Density- & Refractometers

12:10 Lysotherm : 5 jaar ervaring met innovatieve slibhydrolyse. Bert Geraats (Eliquo)

BB-18 Black Body High Vacuum System Technical Description

SenTix 950 SenTix 980

ROTOFIX 32 A Benchtop Centrifuge

A World-class Leading Company in Inkjet Applications INKTEC INK REPORT

Melting Point, Boiling Point, and Index of Refraction

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

DUST EMISSION MONITORING SYSTEM

Digital Full Colour Multi-Function Printer RICOH RICOH MP CW2200SP. B/W 3.2ppm Colour 1.1ppm

HERZ-Thermal Actuators

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

Titrette. class A precision. The next generation Digital Burette!

How To Use A Flowmeter

Rheological Properties of Topical Formulations

Discover Your Potential

USB-500 Series Stand-Alone, Low-Cost Data Loggers

As versatile as your requirements. 384 well. 96 well combi 48 well in situ

CE 204 FLUID MECHANICS

BIOMEDICAL REFRIGERATORS

Digital Hotplate. Stirrers. Compact & Round Plate Type Hotplate Stirrers. Analog Hotplate Stirrer. Digital Hotplate

Multifunction HVAC and IAQ Meter

Material test chamber with mechanical convection

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Fluid Dynamics Viscosity. Dave Foster Department of Chemical Engineering University of Rochester

ACUSOL 810A Detergent Grade Rheology Modifier and Stabilizer

Viscosity Cup Reference Table 1

Transcription:

Lovis 2000 M/ME Microviscometer ::: Viscometry at its best

Lovis 2000 M/ME is a rolling ball viscometer which unites an established measuring principle (Höppler, DIN 53015 and ISO 12058) with innovative and Powerful, versatile microviscometer for R&D: Time-saving, highly precise viscometer for pharmaceutical and medical labs: All-round viscometer for the chemical industry:

performance-enhancing features. More than 25 years of experience make Lovis 2000 M/ME a highly precise, versatile and time-saving viscometer. Lovis 2000 M/ME can be what you need it to be: Small sample amount (as low as 100 µl) Sample recovery Wide temperature range (-30 C to 100 C /-22 F to 212 F) Wide viscosity range (0.3 mpa.s to 10,000 mpa.s) High accuracy Variable inclination angle for testing shear-dependent flow behavior Examples: - Polymer & biopolymer solutions - Nanomaterials in solution - Ionic liquids - Battery electrolytes Included in US Pharmacopoeia Pharma qualification packages available Optional modular combination with Anton Paar instruments for measuring density, refractive index, turbidity and ph value Flow-through filling for large sample throughput Examples: - Hyaluronic acid - Nasal sprays, ear drops - Blood plasma and biological liquids - Infusion liquids and contrast media - Microcrystalline cellulose - Protein solutions & DNA Hermetically closed system for volatile or toxic samples High chemical resistance (borosilicate glass or PCTFE) Special polymer measuring and evaluation features Automatic filling using autosampler Testing of opaque samples Examples: - Polymer solutions - Printer ink, inkjet ink - Solvents - Acids, bases

Touchscreen The color touchscreen display makes user interaction easy. The flexible instrument software allows you to adapt the display to each measuring method. Set your favorites for quick access to your most important functions. Option Low Temperature Use the Option Lovis 2000 M/ME Low Temperature to reach a minimum temperature of -30 C (-22 F). Versatile capillaries Standard length capillaries are suitable for flow-through filling or for manual filling outside the capillary block. For small sample amounts as low as 100 µl, use short capillaries. Capillaries are available made of borosilicate glass or PCTFE. Break-proof PCTFE capillaries enable you to test chemicals as aggressive as hydrofluoric acid.

Capillary block The auto-angle function and auto-distance function optimize the duration and stability of your measurement. The moving capillary block covers an angle range from 15 to 80 in either direction. Lovis 2000 M/ME also displays shear rate and supports automated zero-shear viscosity extrapolation. Air cooling Peltier elements provide fast and stable temperature control. The built-in fan provides sufficient air cooling for measuring temperatures as low as 5 C (41 F). Flow-through filling Use flow-through filling to enhance your sample throughput. Even in manual operation, flowthrough filling makes your work easy: Just fill the syringe, plug it into the filling support and fill the sample into the system.

One Viscometer Many Combinations Lovis 2000 ME is a small measuring module which can be inserted into a DMA Generation M density meter for combined measurement of density, kinematic viscosity and dynamic viscosity. Lovis 2000 M Lovis 2000 ME + DMA M density meter Lovis 2000 ME + DMA M density meter + Xsample The stand-alone viscometer determines the dynamic*, kinematic*, relative and intrinsic viscosity of liquids. This combined system determines the density, kinematic viscosity and dynamic viscosity of up to 96 samples fully automatically. Combinations with other parameters such as sound velocity are also available. Extend the measuring temperatures of Lovis 2000 M/ME down to the low range. Depending on ambient conditions, it is possible to reach -30 C (-22 F). Lovis 2000 M + Abbemat refractometer Lovis 2000 M + Option Low Temperature Lovis 2000 M + ph ME This combination allows you to determine kinematic*, dynamic* and intrinsic viscosity as well as refractive index. This combination determines kinematic*, dynamic* and intrinsic viscosity as well as the ph value. *) with known density

Specifications Measuring range Parameters Temperature Dynamic viscosity Inclination Shear rate Lovis 2000 M Lovis 2000 ME & DMA M 0.3 mpa.s to 10,000 mpa.s 15 to 80 in 1 steps 0.5 s -1 to 1000 s -1 influenced by capillary size and inclination Density - 0 g/cm³ to 3 g/cm³ Viscosity +5 C to 100 C (41 F to 212 F) 1) (without Option Low Temperature) -20 C to 100 C (-4 F to 212 F) 1) (with Option Low Temperature) Density - 0 C to 95 C Precision of Lovis 2000 M/ME Temperature Repeatability s.d. 0.005 C Accuracy 0.02 C Inclination Repeatability s.d. 0.02 Accuracy 0.1 Measuring time Resolution 0.001 s Accuracy 0.05 % Viscosity Repeatability s.d. 0.1 % 2) Accuracy 0.5 % 3) Further specifications Test duration minimal 30 s, typical 3 min Sample volume 0.1 ml to 0.8 ml 1 ml to 3 ml Dimensions (L x W x H) 482 mm x 420 mm x 231 mm Weight 17.0 kg 27.3 kg Power supply AC 100 V to 240 V; 50 Hz to 60 Hz; 190 VA 1) specified temperatures are valid for a max. ambient temperature of 35 C (95 F). Lower measuring temperatures are achieved in lower ambient temperatures and/or with special equipment. 2) verified with a 1.59 capillary at 70 angle and Ethanol 96 % at 20 C using the same ball for all repeated measurements. 3) verified with a 1.59 capillary with a single-point adjustment performed on site at 70 angle; adjustment and all measurements performed with distilled water at 20 C with the same ball. Rolling-ball measuring principle A ball rolls through a liquid-filled capillary that is inclined at a defined angle. Three inductive sensors measure the ball s rolling time through transparent and opaque liquids between defined marks. The liquid s viscosity is directly proportional to the rolling time. F V F B Inductive sensor Ball F G α Sample Capillary F G Gravity F B Buoyancy force F V Viscous force

2015 Anton Paar GmbH All rights reserved. Specifications subject to change without notice. C72IP001EN-F