REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Similar documents
User s Manual AURORA 1.2K/2.2K

How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

COLOR VIDEO DOOR PHONE CDV-71BE/D

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Online UPS. PowerWalker VFI 1000R/1U

User s Manual Before using the inverter, you need to read and save the safety instructions.

Dehumidifier Users manual. For Models: DH45S DH65S

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

EKOS Cart. Instructions for Use

Line Interactive UPS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SPL 2-00/-01 OPERATION INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

TIG INVERTER INSTRUCTION MANUAL

User Manual 1K/2K/3K Online UPS

350, 500, 650 and 1000 MODELS

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

PERF10 Rubidium Atomic Clock

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Uninterruptible Power Supply

DC POWER SUPPLY ALIMENTATION C.C.

LOXONE 12 Channel Amplifier

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Single Day Alarm Clock with. Bluetooth and USB Play-through

User Manual. Video Doorphone CDV-1020AQ

Facility Requirements for the elan2 Office Liquid Nitrogen Generator

USER MANUAL Online UPS 1K/2K/3K

Back-UPS Pro 1300/1500 Installation and Operation

Powerware 5110 UPS User s manual

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

FT-100 Fire Training Fog Machine User Manual English

Installation and Operation Back-UPS 1250, 1300, 1500

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

AIR-CONDITIONER SPLIT TYPE

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Achieving the impossible

BITMAIN. APW PSU Series User Guide

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

USER MANUAL Online UPS 1K/2K/3K Rack

Ultrasonic support removal tank

Congratulations! Thank you!

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Bubble King. User Manual

BB800 Off-Grid Solar System

BroadBand PowerShield. User Manual

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

, User s Manual

Indoor Remote Controlled Power Points

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

USER S MANUAL HSC-24A

1 All safety instructions, warnings and operating instructions must be read first.

Power supply unit Model: PAC-SC50KUA

IMPORTANT SAFETY INSTRUCTIONS

Achat 115MA full-range speaker. user manual

±15 V Current-Limited Power Supply

2KW CERAMIC HEATER DHCER20. User Manual

HM-W536 Install Guide

TOA 900 SERIES II MIXER POWER AMPLIFIER

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

ramon 2.2 Radon Monitor manual

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

BC Pro UPS System Standby UPS System

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

IMPORTANT SAFETY RULES TO FOLLOW

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Home Solar Kit Owner s Manual. Model: HS

12-Volt 10-Amp Regulated Power Supply

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Thyristor-controlled power supplies and battery chargers

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Wine Cooler with Thermo-Electric Cooling & Heating Technology

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Portable Air Conditioner

PowlVac Vacuum Integrity Tester

PE8216/PE8324. Energy Intelligence Solutions

15-INCH TFT-LCD MONITOR

10000HXL31/15000HXL31/20000HXL31

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

MAJORSINE Power Inverter

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

How To Use A Power Supply Unit (Upland)

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Transcription:

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate voltage fluctuations on the mains and supply connected loads with stable voltage. Low voltages as well as high voltages can be harmful for sensitive loads. Voltage Regulators monitor line voltage continuously and with adjustable transformer regulates the load supply voltage. Technical Features CPU Controlled Automatic Voltage Regulation Wide Voltage Range Compact Design Voltage Display Short Circuit and Over Load Protection Low / High Voltage Protection High Temperature Protection Wide Range of Usage (Sensitive electronic equipment for voltage fluctuation) REGULINE 600VA / 1000VA Front Panel Description On/Off Button: Turns On and Off the regulator. Regulator turns on output after 6 sec delay time. Voltage display: Shows input or output voltage when Input/output voltage selection button is pressed. Green section on display shows approximately 180-250V range and red section shows 110-280V range. Input/Output Voltage Selection Button: It allows to select input or output voltage on voltage display. Low/High Voltage Warning LEDs: According to the selection is done by Input/Output Voltage Selection Button, if input or output voltage is low the red LED turn on, and if voltage is high the yellow LED turn on. If voltage is in acceptable range LED s turn off.

Front Panel Back Panel Voltage Display Input/Output Voltage Low Voltage Warning LED (Red) High Voltage Warning LED (Yellow) (On/Off) Button AC Output AC Input Circuit Breaker Technical Specifications Reguline 600VA / 1000VA - Relay Type CAPACITY INPUT Voltage Voltage range Frequency Fuse OUTPUT Voltage range Protection INDICATORS High voltage mode (Boost) Low voltage mode (Buck) DIMENSIONS AND WEIGHT Dimensions D x W x H (mm) Net Weight (kg) ENVIRONMENTAL Humidity Noise level * 300W= Power consumed by 3 pcs 100W bulb ** 500W= Power consumed by 5 pcs 100W bulb 600 VA 300 W 220 VAC 140-260 VAC 50 Hz / 60 HZ 3.5 A 4.5 A 220 V ± %10 Short circuit, Over temperature, Output voltage, Over load protection Red LED Yellow LED 1000 VA 500 W * ** 215 x 114 x 116 2.05 2.66 0-90% RH @ 0-40 C (non-condensing) Less than <40 db

Operating Regulator While the regulator is turned off, connect the power plug to a grounded wall outlet. Connect your equipment power cables to the grounded outlet on the back panel of Reguline 600VA / 1000VA. Turn on and Turn off Regulator To turn on the regulator when it is off, press once on the On/Off button. To turn off the regulator when it is on, press once on the On/Off button. Displaying Regulator Input/Output Voltage If Input/output voltage selection button is not pressed, voltage display shows output voltage. If button is pressed voltage display shows input voltage. All models are single phase. Response and transfer time is less than 0.5 sec. Waveform is sinusoidal and does not contain harmonics. Output delay time is in the range of 6 sec/120 sec. Output voltage high protection level is 260V. If input voltage is between 140-260V regulator can give %100 output power. Maximum output power varies by the power drawn by load. Always place your regulator where; - ventilation is good, - there is no direct sunlight or nearby heat sources, - children cannot reach, - away from water, humidity and oil, - there is no flammable material, - there is no risk of falling down.

WARNINGS Do not overload the regulator above the maximum output power. (See Technical Specifications Table) Make sure the total power of connected load does not exceed the regulator power. For example; electrical heater, oven, combi boilers can take excessive power. For this kind of equipment select suitable regulator power. In order to choose appropriate power, check Technical Specifications Table in user manual or ask your authorized sales representative. Equipment with a compressor motor can take very high currents during start up. If you connect this type of equipment to the regulator please consider its start up current. All connected equipment s total start up currents should not exceed the regulators maximum rated current. All equipment to be connected to the regulator should have the same voltage and frequency rating with regulator and mains. The mains voltage supplying the regulator should be in the regulators input voltage range. Do not connect washing machines rated higher than regulators. Consider CRT TV power two times of the nominal power. There are dangerous voltage levels in Regulator. There are no user serviceable parts in it. Do not open it. Regulator can only be connected with 2-pole, 3-wire grounded outlets. Do not attempt to connect it with different type of outlets. There is risk of electrical shock. In case of emergency to turn off the unit, press Off button and disconnect the power cord from the source. Make sure no liquid or foreign objects enter in the regulator. Do not leave containers with liquid and drinks on or around the regulator. This regulator is designed to be used in a controlled (controlled temperature, indoor, no conductive dust and material) environmental condition. In order to avoid overheating make sure ventilation holes are not covered, do not place the regulator in direct sunlight or nearby heat sources. Before cleaning, turn off the regulator and disconnect the power cord. Do not use liquid or spray cleaners for cleaning.