DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS



Similar documents
Sun Windows General Information Sun New Construction Window Installation Instructions

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Tundra Series Windows January 2016

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Window Installation Instructions

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Basement Window Installation Guide Hopper and Sliding

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

SECTION SERIES 1500 VINYL PATIO DOORS

March 14, Installation of Bay, Bow and Garden Windows

Garden Windows Builders Vinyl

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Barewood Octagon and Elongated Windows Installation Instructions

Clad Direct Glaze Window Installation Instructions

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE

Quality Building Products for over 50 Years

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

Installer Training and Certification Overview

Tuscany Series Vinyl Replacement Windows 3-Part Specification

Series 3502 Thermal Series 3902 Fixed Thermal Architectural Grade Horizontal Sliding Window

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and

Installation Guide for Andersen Architectural Wood Inswing Entry Doors

Astragal: a vertical member placed at the meeting edges of a double door to provide a weather seal and may be used to anchor the fixed door.

New Construction Stud Frame Vinyl Window Installation Guide

Important Information for Installer & Homeowner

SLIDING PATIO DOOR INSTALLATION INSTRUCTIONS USING FRAME SCREWS

Windows Vintage FUSION-WELDED VINYL TILT WINDOW SYSTEM GET THE VINTAGE ADVANTAGE...

4 5/16 Subframe Installation

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

GreenGuard Housewrap Installation Guide

SECTION REFERENCE. Tilt-Wash Double-Hung. Insert Windows. 400 Series

Introduction...COMB-2 Design Considerations and Examples...COMB-3

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

SECTION VINYL WINDOWS. A. The General Conditions, Supplementary Conditions, and Division 01 - Requirements apply.

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006)

Brick Veneer Construction

Quality Windows And Doors. Great Service. Exceptional Value.

ALUMINUM Guide Spec: Standard Aluminum Windows & Doors

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION. Step 1:

City of San Diego, CWP Guidelines

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection.

Replacement Installation Instructions

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

WINDOW PANNING AND TRIMS

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Milgard Style Line Series Vinyl Window 3-Part Specification

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

RAM Industries 8600 Commerce Park Dr Houston, TX Tel: Fax:

In the Fall 2002 issue of HHE News I examined

Designed for Your Life. Guaranteed. Premium Vinyl. Replacement Windows. and Patio Doors

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

WINDOW REPAIR MANUAL & REFERENCE GUIDE

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

InsulView Window Installation Instructions

SECTION POLYVINYL CHLORIDE (PVC) WINDOWS Paradigm Window Solutions 8381 Single Hung

Glossary. Argon: An inert, nontoxic gas used in insulating glass units to reduce heat transfer.

INSTALLATION OF A BAY WINDOW

How To Repair A Boat Landing Deck With A Boat Bed

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

Premium Vinyl Windows and Doors for Replacement Applications

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Residential Window Replacement Design Guidelines

Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

Installation Instructions

T H E A A M A C E R T I F I C A T I O N P R O G R A M

Sash Replacement Guide

Imagine. the transformations that are possible! Add Style & Value to Your Home Cut Energy Costs Drastically Reduce Upkeep

ModernView. The Brickmold Designer Series. The Brickmold Designer Series. TheBrickmoldDesignerSeries. Outside the ordinary.

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

The Illustrated Guide to Installing Vinyl Windows VERSION 7.1

SERIES 3000/4000 DOUBLE SLIDER AND DOUBLE HUNG WINDOWS. Craftsmanship. Style. Performance.

Automatic Door Selection Guide

Installation Instructions For Slider Casement Air Conditioners

Designed for Your Life. Guaranteed. Premium Vinyl. Replacement Windows. and Patio Doors

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

450 SERIES SLIDING GLASS DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

1-1. Casement and Awning Window

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Accessory Windows. Replacement and New Construction

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Gliding Windows Premium Vinyl

Vinyl Replacement Windows

AC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT)

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

THE ULTIMATE HIGH PERFORMANCE REPLACEMENT WINDOWS AND PATIO DOORS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Glossary. 1/3 1/3 1/3 - Configuration of a vent-fixed-vent (xox) window in which the vents and fixed panel are equal sizes

Active and Passive Sash Replacement

Quality Windows And Doors. Great Service. Exceptional Value.

SECTION 6. Glass Storefront Doors:

Transcription:

SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough Carpentry 06 20 00 Finish Carpentry 07 20 00 Building Insulation and Moisture Protection 07 40 00 Siding 07 62 00 Sheet Metal Trim and Flashing 07 90 00 Sealants 09 90 00 Painting Filed Sub Bid M.G.L. c.149 44F Metal Windows is a stipulated filed sub-bid category under M.G.L. Chapter 149, 44F. If the project total cost is $100,000.00 or greater and the cumulative estimated value of the work in this section exceeds $20,000, it triggers the filed sub-bid requirement. The one exception would be if windows are the predominant work, in this case the DCAM category can be doors and windows and a filed sub-bid for metal windows is not necessary. Wood, Fiberglass and Vinyl windows are not required filed sub-bid categories. CODES AND STANDARDS REFER TO AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION FOR LATEST VERSION OF THE NORTH AMERICAN FENESTRATION STANDARD. WWW.AAMANET.ORG Window performance grade ratings must be in accordance with North American Fenestration Standard NAFS 08 (or latest version) as follows: Low Rise for one to three stories R 40 Mid rise for four to eight stories LC50 High- rise for nine stories and above AW60 Consider higher ratings for coastal sites Consider pan flashing for all windows above three stories Windows should meet all Massachusetts Building Code (latest edition and/or stretch code) requirements including labeling by the NATIONAL FENESTRATION RATING COUNCIL NFRC WWW.NFRC.ORG Windows should also: Meet forced entry level 10 Meet Insulated glass construction Class CBA rating (ASTM E 2188) Meet Energy Star requirements www.energystar.gov April 2014 1 of 6

DESIGN Double-hung windows are strongly preferred for new construction. When replacing windows, sliding and casement windows should be replaced with double hung units if possible. Operating force measured after the application of all trim and insulation should be: Families Elderly or barrier-free 35lb in either direction 15lb in either direction with a minimum breakaway force of 15 lb. Installed windows requiring greater force for operating must be field adjusted to comply with operating force limits as directed by the Designer. Windows will also be subject to field testing of breakaway force as directed by the Designer. Avoid sliding windows. They have typically been energy inefficient and difficult to operate. Also, avoid casement windows, especially for families. Both sliding and casement windows are high maintenance items. To ensure easy operation in elderly and barrier-free units, the window stool for double-hung windows should be no deeper than 6 inches wherever possible. Half screens are preferred, but in some rare instances, full screens will be more convenient. Heavy duty security screens may be required at selective urban developments. Air conditioner wall sleeves should be avoided. However, they might be considered for a window replacement project where the number of existing windows does not allow for at least one window to open if the a/c unit is installed in the window opening. Storm windows are not necessary unless single pane windows are retained as part of a historic rehabilitation project or needed for noise abatement. Integral lift rails are preferred. Provide performance specifications defining optimum thermal characteristics (U value & SHGC), air infiltration and moisture resistance for the specific application. Window assembly must have a minimum 10 year warranty. INVESTIGATION AND RESEARCH When replacing windows, check for weight pockets. Insulate voids and weight pockets around windows with fiberglass or foam insulation, backer rods, and caulk, or with backer rods and acoustic caulk. This requirement April 2014 2 of 6

must be clearly spelled out in the specifications. Foam insulation has a better seal, however the correct foam insulation must be utilized or it can have a detrimental effect. See the guidelines on building insulation for more specifics. Check for prior water infiltration or insect damage around windows and include work to repair any possible hidden structural damage under other specification sections. Conduct destructive testing if required. Refer to the latest edition of the building code for code compliance of replacement windows. Review applicable codes for egress requirements. CLAD WOOD WINDOWS MATERIALS Acceptable windows include vinyl clad Andersen Corporation, Perma- Shield Double-Hung, Pella aluminum clad windows and Marvin Clad windows. Factory pre-finishing of the interior of sash is preferred. Pre-finishing is a special order that must be included in the specifications. Coordinate with the painting specifications. Specify aluminum framed insect screens (for durability). Charcoal colored aluminum mesh is generally the most aesthetically pleasing. Vinyl Replacement Sash - Andersen Window Corporation has replacement sash kits available for projects with their Andersen Narrowline windows that were manufactured before 1970. These sash replacement kits can be provided in Pre-finished units and have accessories such as finger pulls available for ease of window operation. These replacement units can be ordered as part of a total project replacement or in quantities that can be installed by LHA maintenance staff. METAL WINDOWS DESIGN Limit the use of metal windows to situations where oversized or structural concerns are a major factor or for storefront applications. Aside from storefront applications, double-hung windows are preferred; sliding windows should be avoided. Design a metal flashing pan and head and jamb flashing system to minimize the possibility of water infiltration. This is especially necessary in applications near the ocean or other buildings subject to higher winds, such as buildings over 3 stories. Thoroughly review manufacturer s details including but not limited to receptors, frame components, flashing details and installation details. Specify adequate thermal breaks and require that air and water infiltration standards to be met. April 2014 3 of 6

MATERIALS When specifying metal windows, give serious consideration to AW60 or better rated window. Use the manufacturer's recommended weatherstripping. If painted, specify a durable paint finish. (Kynar or equal) EXECUTION Insulate around windows with fiberglass or foam insulation, backer rod, and caulk, or with backer rod and acoustic caulk. This requirement must be clearly spelled out in the specifications. Refer to Sections 07 90 00 Sealants and 07 20 00 Building Insulation. FIBERGLASS AND VINYL WINDOWS MATERIALS GENERAL ISSUES Windows meeting AAMA performance standards are required. All extrusions shall be fiberglass or 100% virgin PVC. Nailing fin installation is preferred in new construction and where applicable on replacement windows. FRAME: Overall depth 3 ¼ minimum Minimum vinyl extrusion thickness of.065 Welded frame Sloped sill preferred - pocket sill discouraged unless required for Grade 60 rating. Provide shim blocks to support A/C units to avoid window frame damage. SASH: 4 point welded sash preferred Minimum vinyl extrusion thickness of.065 Metal reinforcing at meeting rails Adjustable cam locks (Minimum of 2 per sash if sash is over 36 wide) Interlocking Sash Double weatherstripping is preferred at meeting rail and base. Tilt-in sash with two spring loaded sash releases, latches on each sash BALANCES: Block and tackle or ¾ constant force balances preferred - Spiral balances are not acceptable. GLAZING IGMA certified construction class CBA www.igmaonline.org Minimum 7/8 thickness Warm edge technology preferred Window grids should be between the glass. April 2014 4 of 6

SCREEN Aluminum framed half screen Charcoal finish aluminum When using locking clips, aluminum is required. Avoid plastic clips. FLASHING All windows in new construction and in retrofits, where feasible, should be flashed with a flashing tape type product similar to Dupont FlexWrap and StraightFlash, Carlisle Window & Door Flashing, or W.R. Grace Vycor or Vycor Plus. Install per manufacturer s recommendations. Windows installed in masonry buildings should always have a pan flashing system installed prior to installing the new window. Typical Flashing Detail for installation of flanged windows in wood framed construction can be found on the next page. April 2014 5 of 6

TYPICAL FLASHING DETAIL IN WOOD FRAMING 1. Make a modified "I-cut" in the weather resistant barrier. Fold bottom and side flaps over and fasten to interior side of rough opening with staples set 12" to 18" apart. 2. Measure for diagonal cuts in weather resistant barrier: 9" up from corner and 9" over from corner and mark (45 diagonal). Cut on diagonal from marked point to rough opening corner 3. Gently raise weather resistant barrier and tape temporarily at corners and center. This will allow for the installation of window head flashing later. Apply flashing at sill allowing 9" of flashing material on eitherside of rough opening. 4. Next, apply jamb flashing on both right and left side over- lapping previously applied sill flashing. Flashing should extend 8-1/2" below and above rough opening. 5. Apply 3/8" nominal bead of sealant in line with pre-punched nail slots on backside of nailing flange around the entire perimeter of window. 6. Be sure window sash are closed and locked. Using shims, be sure window is plumb and square and there is an equal reveal around the unit. Secure window using 1-3/4" galvanized roofing nails through pre-punched holes. Nail every hole. 7. Apply a bead of sealant directly over fasteners and pre-punched holes in mounting flange at top of window. Apply flashing to top of window pressing flashing into sealant and letting flashing extend 10" on left and right side of rough opening. 8. Remove temporary tape applied in step 3 and allow weather resistant barrier to lie flat over the head flashing. Apply new sheathing tape over the entire diagonal cut made in the weather resistant barrier as shown April 2014 6 of 6