INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING



Similar documents
Electromagnetic Radiation (EMR) and Remote Sensing

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Data Sheet. definiti 3D Stereo Theaters + definiti 3D Stereo Projection for Full Dome. S7a1801

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

How To Use 3D On A Computer Or Tv

October 1, (Press release) Nippon Telegraph and Telephone Corporation

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Multispectral stereo acquisition using 2 RGB cameras and color filters: color and disparity accuracy

Computer simulation of coating processes with monochromatic monitoring

Computer Vision: Machine Vision Filters. Computer Vision. Optical Filters. 25 August 2014

3D Modeling Using Stereo Projection

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

Overview. Raster Graphics and Color. Overview. Display Hardware. Liquid Crystal Display (LCD) Cathode Ray Tube (CRT)

Introduction to 3D Imaging

Color holographic 3D display unit with aperture field division

MIMO Antenna Systems in WinProp

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Study of RF Spectrum Emissions in High Pressure Sodium and Metal Halide Lamps. Lawrence P. Glaister VE7IT, Automation Engineer.

Virtual Reality Techniques for the Visualization of Biomedical Imaging Data

GRID AND PRISM SPECTROMETERS

Coaxial Cable Feeder Influence on Yagi Antenna Dragoslav Dobričić, YU1AW

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Example of SOP for IR Laser

Composite Video Separation Techniques

Experiment 5. Lasers and laser mode structure

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

2.3 Spatial Resolution, Pixel Size, and Scale

Realization of a UV fisheye hyperspectral camera

RF Measurements Using a Modular Digitizer

Experiment #5: Qualitative Absorption Spectroscopy

Video Conferencing Display System Sizing and Location

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

Resolution for Color photography

1 Laboratory #5: Grating Spectrometer

Passive Remote Sensing of Clouds from Airborne Platforms

Recording the Instrument Response Function of a Multiphoton FLIM System

Introduction to Add-Drop Multiplexers

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

CASE STUDY LANDSLIDE MONITORING

Chapter 12 Filters for FISH Imaging

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Interpreting the Information Element C/I

Nederland België / Belgique

Multichannel stereophonic sound system with and without accompanying picture

XXIX ENFMC - Annals of Optics D shadowgram projection using a simple diffractive screen José J. Lunazzi, Noemí I. Rivera Rodríguez.

Recent developments in high bandwidth optical interconnects. Brian Corbett.

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Applications. Blue IF 039, Green IF 062, Yellow IF 022, Orange IF 041, Red IF 090,Dark Red IF 091 IR pass IF 092, IF098, IF 093 Surface 1 5/2 0.

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Photonic components for signal routing in optical networks on chip

1. Introduction to image processing

LED Lighting - Error Consideration for Illuminance Measurement

LTCC Short Range Radar Sensor for Automotive Applications at 24 GHz

Experimental results for the focal waveform and beam width in the focusing lens with a 100 ps filter

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

FTIR Instrumentation

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

Module 13 : Measurements on Fiber Optic Systems

Interference. Physics 102 Workshop #3. General Instructions

High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing

PRODUCT INFORMATION. Insight+ Uses and Features

X-ray thin-film measurement techniques

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Broadband Slotted Coaxial Broadcast Antenna Technology

On Cables and Connections A discussion by Dr. J. Kramer

How To Make A Plasma Control System

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Designing Fiber Optic Systems David Strachan

Sensor and Simulation Notes. Note 479. October A Dual-Polarity Impulse Radiating Antenna

Optimizing IP3 and ACPR Measurements

To explain the basics of how lasers work and let visitors experiment with laser properties.

White Paper AMD HD3D Pro Technology: Stereoscopic 3D For Professionals. Table of Contents

Fluorescent dyes for use with the

High-Performance Wavelength-Locked Diode Lasers

RF System Design and Analysis Software Enhances RF Architectural Planning

Raman spectroscopy Lecture

Theremino System Theremino Spectrometer Technology

Optical Communications

3D Raman Imaging Nearfield-Raman TERS. Solutions for High-Resolution Confocal Raman Microscopy.

RESULTS FROM A SIMPLE INFRARED CLOUD DETECTOR

INTERFERENCE OBJECTIVES PRE-LECTURE. Aims

SmartDiagnostics Application Note Wireless Interference

WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP

Frequency Response of Filters

Measuring of optical output and attenuation

Zecotek S Light Projection Network Marketing

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

MSB MODULATION DOUBLES CABLE TV CAPACITY Harold R. Walker and Bohdan Stryzak Pegasus Data Systems ( 5/12/06) pegasusdat@aol.com

An octave bandwidth dipole antenna

Realtime FFT processing in Rohde & Schwarz receivers

The 50G Silicon Photonics Link

Transcription:

INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING Helmut Jorke, Markus Fritz INFITEC GmbH, Lise-Meitner-Straße 9, 89081 Ulm info@infitec.net Phone +49 731 550299 56 Fax _ +49 731 550299 61 ABSTRACT Generation of stereoscopic 3-D images e.g. for visualisation of virtual objects, is currently using techniques like active stereo taking shutter glasses or passive stereo taking polarisation filters. INFITEC is a new technique to display stereoscopic images where the image information is transmitted in different wavelength triplets of the visible spectrum of light. The cross talk in this system is found to be extremely small. As the spectra of the left and right eye image in INFITEC systems are complementary to each other, both images can be generated in principle, by one light source only. Beyond that, wavelength multiplex imaging is compatible to the multiple-viewer functionality. INTRODUCTION Spatial imaging techniques are of importance to a variety of applications that reach from the field of amateurs and fanciers to the field of professional users. Applications in the latter field are usually combined with digital imaging techniques and they have experienced a particular rapid growth in the past years. Driven by the increasing capabilities of graphic boards, there is meanwhile- under the caption virtual reality (VR) - a large number of applications that deal with the spatial visualisation of virtual objects. In practice, the new feasibilities are already used, for instance, in the development of new products, where they enable an identification of deficiencies in the design or the construction prior to the cumbersome prototypical realisation of the new product. THE STEREOSCOPIC DISPLAY Natural perception of depth depends upon different perspectives that are related to different positions of a spectator eyes. To create artificial perception of depth the visualisation system has to display two images that are related to the positions of the left and of the right eye. In such a stereoscopic display the images need to be assigned to the respective eye of a spectator. This is accomplished in different ways: - in autostereoscopic systems images are assigned to different angles of sight (the principle of this technique is illustrated in Fig. 1). Autostereoscopic systems do not need special

glasses from the side of the viewer. They also can display, in principle, a multitude of perspectives of the same object. So, they allow several viewers to get their respective perspective of the object displayed (multiple-viewer functionality). The drawback of autostereoscopic systems is their poor resolution. In order to display a number n of perspectives (n is typically in the order of ten) the resolution is diminished by a factor of n (s. Fig. 1). - in large screen stereoprojection displays - which are preferably used in VR systems as they provide most easily the sensation of immersion - images are assigned either by the active or by the passive stereo technique. In active stereo systems left and right eye image are intermittently displayed. To assign images to the respective eye the viewer has to wear shutter glasses that are suppressing the wrong image. As the shutter function is normally done by liquid crystal panels, these glasses need a power supply (this is why the technique is called active stereo). Alternatively, in stereoprojection systems, the passive stereo technique is used. In these systems normally the light of the left and the right eye image is polarised where the respective polarisations are perpendicularly to each other. The viewer also needs glasses consisting of polarisation filters (which do not need any power supply wherefore the technique is called passive stereo). The advantage of active and passive stereo over against the autostereoscopic display is (besides the normally larger size) the availability of full resolution. A serious drawback, however, is the restriction to two images which impedes that a second viewer can get a spatial image of the virtual object from all sides in parallel (no multiple-viewer functionality). Fig. 1 Autostereoscopic display - schematic set-up

In the following section we want to discuss a new way of passive stereo that allows to display full resolution images. In addition, this way is basically compatible also to the multipleviewer functionality. WAVELENGTH MULTIPLEX VISUALISATION - WORKING PRINCIPLE Light incoming into the human eye is separated into three spectral ranges by three types of receptors that are related to the primary colours blue, green and red. The sensitivities of these receptors over the wavelength are depicted in Fig. 2. Table 1 summarises the wavelengths of maximum sensitivity and the FWHM of the curve of the respective receptor type. According to the three types of receptors in the human eye, colour displays are build up by three pixel types. Each pixel type is emitting light within the sensitivity range of the correlated receptor type. Fig. 2 Colour receptor sensitivity Table 1 Wavelength of maximum sensitivity and full width at half maximum (FWHM) of receptors in the human eye Fig. 3 Spectrum of the laser display The spectral width of the emission is normally not of decisive importance. This parameter is (a) determining merely the saturation of the (a) primary colour. Most saturated colours are obtained by displays with very narrowbandwidth primary colours, such as the laser display where almost monochromatic primary colours are used (Fig. 3). (b) Fig. 4 Display spectrum (a) and input filter characteristic (b) in wavelength multiplex imaging In wavelength multiplex displays, however, another feasibility being inherent in displays with narrow-bandwidth primary colours is used, namely the possibility of transmitting image information in different triplets of primary colours in parallel. In order to assign the information to the corresponding receiver (which is the eye of

the viewer) the information has to be filtered by analogy with the filtering of transmitter signals in broadcasting by the oscillatory circuit at the input (Fig. 4). At optical frequencies the corresponding circuits are represented by high Q interference filters that consist of a multilayer deposition of dielectric materials on, for instance, a glass substrate. These filters can be integrated in standard eyeglasses. The Q value (that is related to the selectivity of the filters) is determining the maximum size of image content that can be displayed in parallel. Physically, interference filters are coupled resonators where the number of resonators is determining the selectivity of the filters. Increasing the number of resonators increases the selectivity of the filters. left eye image right eye Image Fig. 5 Stereoscopic imaging taking two primary colour triplets Taking two triplets B1-G1-R1 and B2-G2-R2, for instance, the wavelength multiplex principle can be used to display stereoscopic images (Fig. 5). To increase the number of viewers of a virtual object in parallel (multiple-viewer functionality, s. previous section), the number of triplets has to be increased to twice the number of viewers (two stereoscopic perspectives for each viewer). The boundary condition that has to be observed for all the triplets is that all monochromatic primary colours (B1... Bn, G1... Gn, R1... Rn) are lying within the bandwidth of the respective human eye receptor. From the FWHM of these curves (Fig. 2) we see, that the bandwidth, available to each primary colour, amounts to about 50nm. So, wavelength multiplex visualisation is capable to combine the advantage of autostereoscopy (multiple-viewer capability) with that of stereoscopy (high image quality by high definition). Besides that, there is a feature of the wavelength multiplex scheme regarding image contrast which is especially advantageous to the front projection situation: as the narrow-band interference filters permit only part of the daylight to pass, interference filters do enhance efficiently the contrast ratio in light rooms which may be of interest also to mono-display applications (one wavelength triplet only). Another aspect of practical relevance may be the feasibility of depositing the dielectric multilayer, which causes the interference filter characteristic, onto glasses with optical correction. So, users with eyeglasses do not need extra-glasses as they can use correction glasses with the specific dielectric multilayer deposition.

THE INFITEC SYSTEM - A FIRST FULL COLOUR WAVELENGTH MULTIPLEX REALISATION Obviously, the laser display would be the most ideal display to wavelength multiplex imaging due to the high coherency of primary colours. Unfortunately, wavelengths used in existing systems are not tuneable and, on the other hand, laser light sources that would be tuneable do not provide the power levels required in displays. Fig. 6 Generation of wavelength triplets in the INFITEC - system Fig. 7 Projection system with integrated triple band filters to generate two sets of primary colours Therefore our experimental work started with another system, namely a projection system with thermal emission light sources (Fig. 6) where the triple band emission characteristic was generated by triple band filters integrated in the projection system (Fig. 7). Emission spectra measured without and with filters integrated are shown in Fig. 8 a - c, respectively.

Fig. 8 Spectrum of a broadband thermal light source without (a) and with type A (b) and with type B filter (c) Stereoprojection with such an INFITEC (interference filter technique) system using an interference filter Type A (primary colours B1 - G1 - R1) to the left eye image and a filter type B (primary colours B2 - G2 - R2) to the right eye image reveals a very clear channel separation with virtually not any cross talking which exceeds clearly that in stereoprojection systems that work with polarisation filters. Regarding colours the left eye image appears to be slightly reddish where the right eye image appears to be slightly greenish. A view to both images simultaneously, however, makes these colour displacements invisible to a majority of viewers and colours appear in a natural way. Major reasons to the colour displacements are (i) the closer proximity of the R1 primary to the maximum of the red receptor and (ii) the closer proximity of the G2 primary to the maximum of the green receptor (Fig. 2). We found that colours in the left and in the right eye image can be efficiently approximated by an electronic mixing of the primary colour signals according to a scheme R' = a 11 R + a 12 G + a 13 B (1) G' = a 21 R + a 22 G + a 23 B (2) B' = a 31 R + a 32 G + a 33 B (3) where this scheme needs to be applied both to the left and to the right eye image signals. With this scheme we are able to approximate colours in a satisfactory way also with projection systems that produce very strong and not acceptable colour displacements otherwise. Generally, projection systems with lamps exhibiting line emissions (s. Fig. 9 a) belong to that group as the intensities in respective primary colours are very different (s. Fig. 9 b, c).

Fig. 9 Spectrum of a UHP (ultra high pressure) lamp without (a) and with type A (b) and with type B filter (c) In future laser display systems corresponding primaries can be presumably put close together which, in turn, would reduce the need for an additional electronic colour correction scheme. PERSPECTIVES AND OUTLOOK Wavelength multiplex visualisation is a way to display stereoscopic images to a multitude of viewers in a correct viewing perspective at the same time. To get full access to that functionality, however, display techniques with very narrow bandwidth primary colours need to be available. In a short term perspective, wavelength multiplex imaging can be realised by the INFITEC approach, where narrow bandwidth primary colours are generated by filtering the emission of a broadband emitting light source. As the spectra of the left and right eye image in the INFITEC system do not have common parts (they are complementary to each other in a sense) both spectra can be generated, in principle, by one light source. This opens the prospect of a compact and low weight stereoprojector that needs one light source and one objective only.