Similar documents
ABLOY EL420, EL520 Europrofile motor locks

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks


ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

ABLOY DC 240 DOOR CLOSER Heavy duty door closer


Narrow stile lock 1314

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions

ABLOY VEGA CABINET LOCKS

Digital Keypad Use s Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

Mechanical Entry Locksets

Modular mortice locks

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Mechanical Digital DX Locks

Panic & emergency exit devices

WE ARE UNION. replace with new shot. Mortice Lock Range. ASSA ABLOY, the global leader in door opening solutions

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Standard Door Specification

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

Lock Function Chart Page 1 of 7

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Shunt lock function 3066 Operator Instructions

Patented technology ASSA P600. Reliable master key system. ASSA ABLOY, the global leader in door opening solutions

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Adaptability to Enhanced Security

TS93 EMR T/PT/TDE. Surface applied door closer

Adaptability to Enhanced Security

TrueAlarm Fire Alarm Systems

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Basic Technical Fundamentals of Builders Hardware

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Combi B Alarm box. Mounting instructions

PHA 2000 PHB 3000 EXIT PAD

HERZ-Thermal Actuators

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

YALE DIGITAL DEADBOLT

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

P10 - Standalone Access Controller and Reader

AR-721U/721K/661U User s Guide

Basic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks

1000 Series Knob Pushbutton Locks

Simplex. Mechanical Pushbutton Locks Keyless Convenience

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

EMF/EMR. Holder/Release Devices with Integral Door Closers

USER MANUAL V5.0 ST100

Conventional Fire Detection and Extinguishant Control System Specification

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

KEY CYLINDER PLATFORMS

Mortice Lock. ASSA ABLOY, the global leader in door opening solutions

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

SECTION DETECTION AND ALARM

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

1R / 4-BUTTON SERIES

Shunt lock function 3066

CISA Safe Home. Locks for shutters and security grates

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

Electromagnetic Locking

COASTAL SERIES. 316 Solid Stainless Steel Door Furniture

Key in Knob & Key in Lever

Mechanical Pushbutton Locks Keyless Convenience

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

DC-8706K Auto Dial Alarm System

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

Solid as a rock Soliroc

Car Alarm Series 2 B 2 Buttons

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

What locks do I have Timber Doors

INSTALLATION MANUAL XM3 Reader

SMARTair TM. It s time to change!

Lockwood Digital Deadbolt

Controller board and power supply for vivimat III systems

InSync Lock Series SAM RF Software. Key Control Systems for Multihousing

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Model: DC-A2IO Advanced HVAC Controller

Instructions for Safe Use

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Relevant British, European and International standards

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

CREATING LOCKING SOLUTIONS...

DCS Input/Output Relay Card Series

GSM HOME SECURITY SYSTEM

Fire Resistant Systems

Advantium 2 Plus Alarm

Transcription:

ABLOY EL490 AND EL590 SCANDINAVIAN RANGE MOTOR LOCKS Flexible multifunctional locking ABLOY EL490 and EL590 motor locks have been developed to further increase both the security and safety of the entire door environment, especially in fire doors and emergency exit doors supplied with access control and alarm devices. Abloy Oy An ASSA ABLOY Group company

STANDARDS ABLOY Motor locks have been tested according to the following standards: EN1634-1 (for fire resistance) pren1446 (for electromechanically operated locks) EN179 (for emergency exit doors) They are also designed to comply with EN 1125 (for panic exit doors) The durability of ABLOY EL490 and EL590 motor locks has been tested with 500.000 cycles. Abloy Oy is the word's leading developer of products in the field of electromechanical locking technology. Our extensive product range includes solutions for varying demands of different standards, functions and door types. In the ASSA ABLOY Group, Abloy Oy is the center of excellence in the field of electromechanical locks. Our role is to lead and manage the development of electromechanical locking technology. More information of Abloy Oy and our products you can get at www.abloy.com. Abloy Oy reserves the right to make alterations without notice. www.abloy.com Abloy Oy Wahlforssinkatu 20 P.O.Box 10 FI-0101 JOENSUU FINLAND Tel. +35 20 599 2501 Fax +35 20 599 2209 ISO 9001 ISO 14001 CERTIFIED ORGANISATION 02257 09/2006 2000 kpl, Suomen Painotuote, Joensuu An ASSA ABLOY Group company Abloy Oy is one of the leading manufacturers of locks, locking systems and architectural hardware and the world s leading developer of products in the field of electromechanical locking technology. ASSA ABLOY is the world s leading manufacturer and supplier of locking solutions, meeting tough end-user demands for safety, security and user friendliness.

MORE FUNCTIONS LESS ACCESSORIES The new ABLOY EL490 and EL590 motor locks offer most comprehensive features which reduce the need of accessories in both access controlled emergency exits and fire doors. For example there is no longer need for emergency power supply, exit buttons, thumbturns or emergency exit domes. In addition to that more status information is available. One-way access controlled doors no need for emergency power supply in fire doors no need for separate push buttons or emergency exit domes the door can always be opened with the inside handle Doors with both access control and fixed time control no need for separate push buttons or emergency exit domes the door can always be opened with the inside handle In case of power failure the bolt always dead locks. Two-way access controlled doors no need for emergency exit domes no need for magnetic locks in especially demanding applications in emergency situations the door can always be opened with the inside handle Entrance doors for customers with both access control and fixed time control no need for emergency exit domes in emergency situations the door can always be opened with the inside handle

APPLICATION The electromechanical ABLOY locks offer complete high security solution whenever you need pedestrian traffic control in addition to mechanical locking safety, for example in fire doors and emergency exit doors. By using the latest technology, the new generation of ABLOY motor locks are developed to further increase both security and safety of the door environment. More possibilities - less product versions ABLOY motor locks EL490 for narrow profile doors and EL590 for wooden and metal doors are developed to aid product selection for demanding and functionally challenging door environments. The new motor locks are especially suitable for one- and two-way access controlled fire doors and emergency exit doors. One-way access controlled doors Typical applications are the exterior and fire doors of business premises hospitals Doors with both access control and fixed time control Typical applications are the exterior doors of educational premises public buildings sports halls apartment buildings Two-way access controlled doors exterior and fire doors of business premises access controlled doors, which are used also as emergency exits hospital and residential building doors, when special control is needed (e.g. dementia wards) Entrance doors for customers with both access control and fixed time control exterior doors of business premises, where extra security is required to prevent vandalism (e.g. bank entrance doors)

One-way access controlled doors FUNCTION The lock is electrically controlled by access control system. Mechanical opening by cylinder and inside handle is always possible. Please note the following lock case settings: Bolt throw 14 mm in fire rated doors (EL590) Doors with both access control and fixed time control The lock is electrically controlled by fixed time control or access control system. When time controlled, the door can be opened by pulls and when access controlled, the door can be opened by a reader outside and with inside handle. Mechanical opening by cylinder and inside handle is always possible. Two-way access controlled doors The lock is electrically controlled by access control system, i.e. the lock can be opened by readers from both sides of the doors. In case of emergency the door can be opened with the inside handle, which is activated by e.g. central fire alarm. In case of power failure, mechanical opening with the inside handle is always possible. Please note the following lock case settings: The bolt throw 14 mm in fire rated doors (EL590) In emergency exit doors the handle operation must be changed to electrically controlled Accessory Exit button Entrance doors for customers with both access control and fixed time control The lock is electrically controlled by access control system. Mechanical opening by inside cylinder is always possible. In case of emergency the inside handle is controlled by e.g. central fire alarm system or with exit button. In case of power failure, mechanical opening with the inside handle is always possible. Please note the following lock case settings: In emergency exit doors the handle function must be changed to electrically controlled Accessory Exit button

6 TECHNICAL INFORMATION FEATURES ABLOY EL490 and EL590 motor locks offer several functional options in just one lock case. Because all the options are covered by a small number of versions, the same lock can be used in several differently functioning door environments. The following mechanical and electromechanical functions can be set at the installation phase handing of the bolt and trigger bolt bolt throw: 14 or 20 mm (EL590) handle function: mechanical or electrically controlled opening delay 1-20 sec. MONITORING The lock includes the following monitoring outputs: bolt deadlocked handle down cylinder/ thumbturn monitoring (available as an accessory) The monitoring output for door automatics: bolt in The monitoring outputs are not available during power failure. DIMENSIONS ABLOY EL490 27 253 1 104 2x 5.5 R.2.6 16 12 23.5 15 17.5 21.3 21.5 5.1 3x 5.5 21.3 115 211.5 TECHNICAL DETAILS Operating voltage: Current: Max Normal (seal force 50N) Idle Relays: Operating temperature: Bolt throw: Backset: Forend: Spindle: Door clearance Finish Cylinder/ thumbturn monitoring: DELIVERY 12 (-10%) - 24 (+15%) VDC STAB 1700 ma (12 VDC) 700 ma (24 VDC) 600 ma (12 VDC) 250 ma (24 VDC) 50 ma (12 VDC) 25 ma (24 VDC) Max. 30V, 100 ma -20 +60 C 14 mm / 20 mm (EL590) 14 mm (EL490) 50 mm (EL590) 29 mm / 35 mm (EL490) 22 mm (EL590) 25 mm (EL490) mm 2-5,5 mm (the distance between forend and striker plate) Chrome plated forend Switch 9505 (EL590) Switch 9506 (EL490) ABLOY EL590 255 233 14/20 5 10.5 6 22 25 3 6.5 6.5 3 29/35 47/53 75 50 5 1 29 12 30 15 105 25.5 37.5 16 35 30 3 19.5 19.5 Standard delivery includes: Lock case, handing 2,4 Fixing screws etc. Drilling, installation and wiring manuals CYLINDERS AND ACCESSORIES SCANDINAVIAN CYLINDERS ABLOY PROTEC ACCESSORIES (Please order separately) STRIKER PLATE CABLES LEAD COVERS HANDLE EL590 EL490 Single Double Single Double Single Thumbturn CY021N (inside) CY037N (outside) CY002N CY06N (inside) CY047N (outside) CY067N CY047N (outside) CH014 (inside) LP712 LP732 4613 4614 EA217 (6m) EA227(10m) EA22 (0,5m) 1x0,14mm 2 EA20 EA21 See ABLOY *) Architectural Hardware brochures eg. PRESTO 3-20/030 for EL590 and PRESTO 3-20/0630 for EL490. *) For further information, please contact Abloy Oy Tampere factory