Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

Similar documents
Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Liebert SiteScan Web. Quick-Start Guide. Monitoring For Business-Critical Continuity

MONITORING. IntelliSlot USB Card USER MANUAL

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Protecting Our Information, Protecting Our Resources

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Protecting The Critical IT Infrastructure of the United States

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

How To Make A Data Center More Efficient

TraceTek. Leak Detection and Location Systems FIND LEAKS BEFORE THEY FIND YOU

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Best Practices for Wire-free Environmental Monitoring in the Data Center

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Enterprise Remote Monitoring

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

Liebert IntelliSlot Web Cards

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

How To Run A Data Center Efficiently

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Best Practices for Wire-free Environmental Monitoring in the Data Center

Liebert PPC Second Generation Power Distribution Cabinet

Ammonia Detection System Codes and Design Specifications

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

DCF Optimized Rack System

Industrial Strength Leak Detection

How To Improve Energy Efficiency In Data Center Management

Sensor Network for HACCP Food Safety Management

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

APC APPLICATION NOTE #112

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Liebert SiteScan Web System

How to Prevent Liquid Damage Property Losses

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Raised Floor Data Centers Prepared for the Future

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

WiFi Edition

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

SiteWeb Monitoring System. Real Time Power and Environment Monitoring Platform for Telecom Applications

Intelligent Mould Flow Monitoring

Protecting Your Home From Water Damage

T5000 T000 LCD Digital Fan Coil Thermostat

A cure for water damage in real estate

IT White Paper. N + 1 Become Too Many + 1?

Power and Cooling Technologies for Business-Critical Continuity. The Power to Adapt. The Power to Succeed.

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

SingleNet Single Cable Control System

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

Access Control and Operating Conditions Monitoring System for Telecommunication and Server Racks

Ceiling Mount Air Handler Manual

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

Wireless Field Data Backhaul

IP Box Camera ACM Ver Hardware User s Manual

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

InHome Water Leak Detection Package

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Domonial, le Sucre. Easy to Use Intruder Detection Systems

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Solution Analysis White Paper CHOOSING THE RIGHT UPS FOR SMALL AND MIDSIZE DATA CENTERS: A COST AND RELIABILITY COMPARISON

CenterMind G+ Smart and Proactive Environment Monitoring

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

WATER LEAK DETECTION FIND LEAKS BEFORE THEY FIND YOU

Doc 10. UTM Standards: Card Access Security System

Bringing open IP benefits to physical access control AXIS A1001 Network Door Controller

A COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Liebert Monitoring Solutions: Protecting Your Investment Against The Unknown. Monitoring For Business-Critical Continuity

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

LIFE Technology Enabling Remote Service Delivery

Securely Deliver Remote Monitoring and Service to Critical Systems. A White Paper from the Experts in Business-Critical Continuity TM

Virginia Tech. Background. Case Summary. Results

Cooling Channel Optimization

SMART SENSOR COLLECTION

later damage - Loss ControL

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Choosing Close-Coupled IT Cooling Solutions

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Liebert NXL Power-Tie Controls

Element D Services Plumbing

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Transcription:

Liebert Liebert Liqui-tect Leak Detection and Reporting M o n i t o r i n g S o l u t i o n s COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPES Accurate, Reliable Systems For Detecting, Locating And Reporting Leaks In Computer Rooms, Telecommunications Centers And Other Facilities Housing Sensitive Electronic Equipment.

WATER DAMAGE CAN BE A CATASTROPHIC EVENT FOR COMPUTERS AND NETWORKS 2 Your critical computing, communications or process control facility could be exposed to water and you may not even know about it until it's too late. Water damage due to leaking pipes, sprinkler systems, leaking roofs and other causes is far more common than realized. What risks exist in your facility? Leaking Roof Can allow substantial amounts of water to enter the shelter over time. Unattended Facility Remote communications shelters require monitoring to protect against damaging water leaks. Flooding Water from the outside could flood the inside of the structure. Flat Roof Water Penetration Standing water can make its way into the critical space, causing water damage. Clogged Drain Drainage systems designed to remove water can become a serious liability if blocked or otherwise closed.

Plumbing Any water piping located near critical equipment poses a risk if leaks develop. sprinkler systems waste systems condensate piping chilled water piping condenser water piping Liebert is the one source that can help you avoid these problems with a full range of leak detection and reporting systems. UPStation GXT + INPUT BATTERY UPS ON BYPASS UPStation GXT + INPUT BATTERY UPS ON BYPASS UPStation GXT + INPUT BATTERY UPS ON BYPASS UPStation GXT + INPUT BATTERY UPS ON BYPASS Room Located Below Grade Areas located below ground level are subject to water seepage from outside as well as leaks from the floor above. Humidifier Drip pans for humidifiers or air conditioning units can overflow if not regularly checked. 3

LIEBERT LIQUI-TECT YOUR BEST SOLUTION FOR LEAK DETECTION Liebert leak detection systems deliver quick and accurate notification at the first sign of trouble. They also offer the ability to interface with your monitoring and building management systems to provide the broadest possible range of communication. 4 Liebert Liqui-tect leak detection systems provide accurate reporting of leaks below the floor, above the ceiling or at the perimeter of a room in critical facilities. These reliable systems provide immediate warning and precise location, allowing you to find and correct a leak before moisture can damage computers, wiring connections or other sensitive electronics. Liebert Liqui-tect leak detection systems are ideal for a variety of locations, including: Computer rooms. Large-scale network control centers. Telecommunications facilities. Satellite ground stations and other specialized data communications nodes. Industrial process control rooms. Any location where water can cause problems. Applications: Glycol, condenser water and chilled water cooling piping leak. Humidification feed water piping. Condensate pumps and drains. Unit and ceiling auxiliary drip pans. Overhead piping. Liebert Liqui-tect Monitoring System Two Channel Direct-Read Leak Detection Liebert brings you the ultimate in leak detection and reporting capabilities. The Liebert Liqui-tect Monitoring System provides two channels for monitoring different areas with direct-read at the control unit location, as well as the ability to communicate with Liebert's SiteScan Web enterprise monitoring system or a building management system. User-Friendly The Liebert Liqui-tect Monitoring System features an easy-to-use liquid crystal display (LCD) panel with readout of normal and alarm conditions, as well as leak location. Display and measurement modules are contained in a single compact package. Installation Flexibility The slim profile of the monitoring panel enables the Liebert Liqui-tect Monitoring System to be mounted on a wall or recess-mounted within a wall. A choice of two different panels sizes provides flexibility to meet application needs. The panels are made of metal to accommodate secure conduit fittings and protect components against environmental debris. Two Channel Capability with Accurate Sensing The Liebert Liqui-tect Monitoring System has two independent channels to monitor two different areas. Each channel can monitor up to 5000 feet of Liebert LT500Y leak cable. Single-person mapping makes it easy to configure within the critical space. The system determines the location of water on the detection cable and reports the distance from the Liqui-tect Monitoring System, in feet or meters. Within seconds of detection, the measurement is flashed on the display panel, allowing you to take prompt action to correct the leak and prevent damage. To ensure proper protection, the system continuously monitors operation, signaling system normal, leak detected and cable fault.

Outstanding Features And Monitoring Versatility Liebert Liqui-tect 460 (zone sensor) Liebert Liqui-tect Zone And Point Leak Detection Sensors Liebert Liqui-tect zone and point leak detection systems install quickly and work simply for reliable warning of potentially hazardous water leaks. Liqui-tect leak detection sensors offer many outstanding features, including: Liebert Liqui-tect 410 (point sensor) 5 Standard Dry-Contact Output Sensors are easily monitored by numerous monitoring systems and equipment such as Liebert environmental equipment via local alarm contact. Also compatible with Liebert's SiteScan Web enterprise monitoring system and thirdparty equipment. Dual Output Relays Two independent outputs provide added flexibility to signal a local alarm panel, a remote building management system or external equipment such as a water shut-off valve. Supervised Operation Sensors constantly monitor for leaks, internal fault and power failure, warning of any abnormal conditions. Easy Installation Separate power and signal wires simplify circuitry needs. Mounting brackets allow for sensor height adjustment and leveling (Liqui-tect 410). Convenient kits are available pre-packaged with sensor, cable and hold down clips (Liqui-tect 460). Liebert Liqui-tect 410 sensor offers leak detection at critical points under a raised floor. Two corrosion-resistant gold-plated probes detect moisture and immediately signal the monitoring system, allowing fast action to be taken before mission-critical equipment is damaged. Liebert LT500Y Leak Detection Cable offers durable design for accurate sensing and the ability to read and report the exact position of the leak. Liebert leak detection cables have a multi-wire design for precise identification of moisture and signaling. Rugged, durable materials resist corrosion and abrasion for long cable life. The cable's non-kink design makes it easy to position around equipment. After a leak is corrected, the cable sheds liquid quickly for an easy return to normal conditions. Liebert LT500Y leak detection cable is designed for easy installation and unlike other sensing cables does not exhibit memory. This means that the installation goes in easier and does not require additional attention to how flat the cable is laying on the floor. Likewise, mating connectors on each end make installation and removal simple. Extra lengths of cable can be added to the end of the cable or any spot along the length of the cable where mating connectors are found. The thermally bonded cable is rated at 176 F (80 C) and is plenum rated. UL-listed for safe operation, LT500Y leak detection cable is available in 15, 35 and 50 feet lengths. Liebert Liqui-tect 460 sensor provides zone detection of leaks up to 100 feet. Designed for use with Liebert LT500Y leak detection cable, the Liqui-tect 460 is the ideal solution for perimeter sensing or serpentine coverage of small areas. Selectable modes of operation provide flexible alarming options and protection for the cable. Selectable alarm delays minimize false-positive conditions. Top cover LEDs primarily provide status indication, but the LEDs also ensure the sensor is easily located under raised floors. If obtained in a kit, cables are available in lengths of 20, 25, 30, 35 and 45 feet.

THERE IS A LIEBERT LEAK DETECTION SYSTEM TO MEET THE NOTIFICATION NEEDS OF ANY SITE 6 LIQUI-TECT PANEL Channel One 1 Channel Two C O M P U T E R - 5 Channel Two C O M P U T E R Channel One Channel Two 4 Liebert Liqui-tect Monitoring System Two Channel Direct-Read Leak Detection Cable Layout When used with the Liebert Liqui-tect panel, Liebert LT500Y leak detection cable is laid in a continuous pattern around potential leak points located throughout the room. Up to 5,000 feet of leak detection cable can be connected to each channel. - 2 Channel One - 3 Liebert Leak Detection Systems can be configured to match the protection needs of any site. Liebert LT500Y leak detection cable Liebert Liqui-tect 410 Point Leak Detection Configuration Typical installation of a Liebert Liqui-tect 410 leak detection system used to monitor the space surrounding a Liebert Deluxe System /3 precision air conditioning unit. Liebert Liqui-tect 460 Zone Leak Detection Configuration The Liebert Liqui-tect 460 uses flexible cable for zone monitoring. Here the system is shown connected directly to a Liebert Deluxe System/3 precision air conditioning unit. Cable should be placed 2 to 6 feet away from the equipment being monitored. Two hold down clips should be used every 6 to 8 feet.

Liebert Leak Detection: Just Part Of An Overall Critical Facility Monitoring Strategy Liebert Liqui-tect leak detection systems are designed to work seamlessly with Liebert's SiteScan Web enterprise monitoring system, a web-based site monitoring and control solution for computer support equipment and other critical facility applications. Liebert interface hardware allows connection of the leak detection controls to the enterprise monitoring system. 7 SiteScan Web Server (Windows Platform) TCP/IP (Ethernet) SiteScan Web Clients (Web Browsers) The Liebert Liqui-tect Monitoring System's control unit incorporates a built-in liquid crystal display (LCD) panel which provides a readout of operating conditions including alarms and leak locations. SiteGate-E SiteLink4 to Liebert IGM Units Liqui-tect Liebert's SiteScan Web monitoring system can graphically represent your leak detection layout in 2-dimensional and 3-dimensional floorplans.

TOTAL CONFIDENCE IN THE DECISION YOU'VE MADE Liebert Liqui-tect Leak Detection and Reporting M o n i t o r i n g S o l u t i o n s No organization in the world today has a better understanding of exactly what it takes to keep critical information and industrial processes operating continuously than Liebert. It starts with your local Liebert Representative, Distributor or Reseller. We are the only company in this business that maintains such a strong local presence on a national and international basis. This resource, coupled with our broad product line, gives Liebert the ability to create a "tailored solution" that will meet your protection needs precisely and efficiently. With your purchase of a Liebert product, you are buying into a company that stands behind its products. You are also aligning yourself with an organization that has a reputation for quality and reliability that is second to none. In the systems protection business it's when you need someone to count on that you find out whether you ve made the right choice. Liebert customers many of them with us for over three decades already know how good their decision was. L I EBERT C O RPORATION 1050 DEARBORN DRIVE P.O. BOX 29186 COLUMBUS, OHIO 43229 800.877.9222 PHONE (U.S. & CANADA ONLY) 614.888.0246 PHONE (OUTSIDE U.S.) 614.841.6022 FAX VIA LEONARDO DA VINCI 8 ZONA INDUSTRIALE TOGNANA 35028 PIOVE DI SCO (PD) ITALY 39 049 9719 111 PHONE 39 049 5841 257 FAX EMERSON NETWORK POWER ASIA PIFIC 7/F., DAH SING FINANCIAL CENTRE 108 GLOUCESTER RD, WANCHAI HONG KONG 852 25722201 PHONE 852 28029250 FAX L I EBERT W EB S I TE http://www.liebert.com 24 X 7 TE CH S UPPORT 800 222 5877 PHONE 614 841 6755 (OUTSIDE U.S.) The day your critical operations are threatened by excessive heat, power problems or other risks is no time to find out if a "simple" solution to system protection will work. Let Liebert help you make the smart decision about assuring reliability in your high availability facilities. While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2003 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. The Emerson logo is a trademark and service mark of Emerson Electric Co. SL-31500 (R10/04) Printed in USA