ELECTROFOK MACHINE. ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC)



Similar documents
MICRO FIBER OPTIC CABLE BLOWING MACHINE WITH ELECTRIC

HYDROFOK (Cable & Tube Blowing Machine with Hydraulic Power Unit)

MINIFOK MACHINES MINI FIBER OPTIC CABLE BLOWING MACHINE. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

FOK MACHINES FIBRE OPTIC CABLE BLOWING MACHINE USER S BOOK. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

HYDROFOK MACHINES. HYDRAULIC CABLE & TUBE BLOWING MACHINE with HYDRAULIC POWER UNIT) fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

CPME CABLE PUSHING MACHINE WITH ELECTRIC MOTOR. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

AIR COOLER. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

FOK MACHINES FIBER OPTIC CABLE BLOWING MACHINES. FIBER OPTIC CABLE BLOWING MACHINES

Model 43AP Pneumatic Controller, Style B

Fish Grader User Manual

Platform Carts. Growing Together

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

Atling proudly presents the next generation self centering steady rests ATLING. Ockelbo Sweden. AX Steady Rests

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

Butt Fusion Welding of HDPE Pipes Work Procedure

AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT.

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

TMS TANK MANAGEMENT SYSTEM

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Adjustments for the Active Pneumatic Vibration Isolation Table during Final Installation (File version 6)

Penguin displays are unique alternatives to traditional roll up banners, pop up displays, and portable literature racks.

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Belt Conveyor System

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Stock List: >>Offset- Printing Machines

QUANTIFYING SOLAR ENERGY

Floor Heating Warehouse.co.uk

Feed systems. Effective handling

VW Caddy W INSTALLATION INSTRUCTIONS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Wet alarm valves. Wet alarm valves. FM trim

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

Please also see 10 golden rules for correct Saniflo installation on

INSIDE ENGINE COMPARTMENT TOYOTA AIR CONDITIONING ENGLISH EUROPE,GENERAL,AUSTRALIA

UNITOR VACUUM cleaners

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Manual piston sampler...m 11

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

Economy Combo Heat Press Manual Model No.: ECH-800

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

AUTOMOTIVE AIR CONDITIONING SYSTEM.

all VAC LIFT ALL-VAC-LIFT Phone Redstart Street Fax

Hydraulic Control Solutions

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

2003 ACCORD - Automatic Transmission Removal

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

RANGE MAXX TURBO BLOWING SYSTEM & SWITCH UNIT. 1A307 Range Maxx turbo blowing system (380 V blower V feeder) 5.249,00

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

Product Data Sheets. Belt Conveyor System

2700 DUST CONTROL MACHINE:

INSTALLATION INSTRUCTIONS

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

HYDRUS ULTRASONIC METER

GenStore Archive Cabinet

Model Year: 2010 Model: Prius Doc ID: RM000001Y3B015X. Title: ALIGNMENT / HANDLING DIAGNOSIS: FRONT WHEEL ALIGNMENT: ADJUSTMENT (2010 Prius)

ASSEMBLY MANUAL SE-4S35

Section 5: Machine Overview

FAG Hydraulic nuts. Technical Product Information

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

Operation manual and Spare parts list EL PUMP. November

COMMERCIAL GAS DRYER

Extract of the White paper Reduce energy costs in compressed air systems by up to 60%

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Portable Air Conditioner

FIRE-FIGHTING DESIGN BRIEF REPORT

with installation dynafact boost GAUGE this manual is for use with systems

Skirt 1 / 4. The Skirt. The skirt patterns were downloaded from Mark's site but they need expanding before they can be used.

COOLING SYSTEM Section Page

Wheat Flour Milling Machinery

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN.

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck

Laddomat Charging unit

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

Saferand easierinstallation

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

18. CARGO TROLLEYS, LIFTING TABLES, HYDRAULIC TABLE TRUCKS, HAND TROLLEYS

PRODUCTS PRODUCTS ABOUT US.

Operating Instructions Hand pallet trucks HU Profi. Issue

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

Fiberstars Lighted Laminar Flow Fountain Installation Manual

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Transcription:

ELECTROFOK MACHINE ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC)

GENERAL DESCRIPTION ELEKTROFOK is designed and produced with feedbacks from users who has specialty on cable blowing technologies. Elektrofok is using to blow cables from 1mm to 5 mm. You need to give us duct diameters in your project before ordering machine. Machine consists on four parts as you can see in figure 1. *Cable blowing group is blowing cable in duct with controlling byelectric panel. *You can control cable blowing speed and direction. *You can see the distance of cable you blowed from electric panel. *The most important thing of machine is sensor design which prevents breaking of cable. Machine stops before breaking of cable. *Air regulater system is setting air pressure in duct and also you can open,close air. *You can put machine on desired place and height with high quality tripod table. 2) Electric Panel Group 1) Cable Blowing Group 3) Air Regulater Group Elektrofok Control Needed electricity Needed air Cable blowing speed Dimensions of machine Dimensions of box Weight of machine with box = Micro fiber optic cable blowing machine with electric. = Technician. = City electric. = 15 bar -1 metercup/minute (NOTE=It can be changed to the different factors) = 0 to 50 meter/minute = 30 cm * 40cm * 15cm = 71 cm * 45cm * 42cm = 28 kg 4)Tripod Table Figure-1 1)USING CABLE BLOWING GROUP 1-A)MONTAGING DUCT,NUTRINGS AND O-RINGS Duct Montaging = Push the duct to the barrier (part 1 on figure 2) then turn part 2 to fix duct between part 3 and 4 as in the figure 2-a. 1 Montaging Nutring = The part 6 in figure 2-b is nutring.when you montage nutring, air canals of nutring must be on the direction of duct. Nutrings must be cutted from to take cable out from the nutring.when you montage nutring, cutted place must be on the underside to prevent air leaks. 4 3 2 6 5 Montaging O-rings = Part 5 in figure 2-b is o-ring. O-rings is montaging between duct and nutring as in the figure 2-b.If you do not montage nutrings like that air leaks happens.you need to change nutrings after someuse to prevent air leaks. Figure-2-a Figure-2-b

5 1-B)MONTAGING FIBER OPTIC CABLE and ADJUSTING PRESSURE ON CABLE BETWEEN ROLLS 6 7 1-C) CHANGING THE RUBBERIZED WHEELS 8 Figure-3 Figure-4 Montage fiber optic cable on machine as in the figure 3 and then close machine s upper part by turning part 5.Fix clamps as in figure 4 to prevent air leaks.wheels presses on cable,pressure on cable can be easily setted by turning part 6. Figure-5 Figure-6 Fiber optic cable is driven by rubber wheels.rubber wheels can damage after some use. These wheels can easily remove and change with new one as shown in Figure-5 and Figure-6. First, number 7 bolts must be took out so upper and bottom covers will be removed. Then, number 8 bolts on the wheels must be took out. Lastly, both wheels should remove slowly and change with spare ones. 2) INSTRUCTIONS FOR USING CONTROL PANEL 8 9 10 11 -Fiber optic cable drive forward and back with switch 8. This switch moves the cable -Speed of cable can adjust with the help of switch 9. -When you start machine, speedof the cable must be fewer then % 50. After starting you can increase speed. -You can open and close the sensor from switch 11. - Switch 11 activates the sensor to not to break cable.gives the alarm lamb on number 10 before the cable breaks. -See the cable blowing meter on screen 12. 12 Figure-7

16 15 14 13 3) INSTRUCTIONS FOR USING AIR REGULATOR UNIT Air connection to the machine made on the number 13 quick connection part. Number 14 valve opens and closes air intake. Air pressure inside the HDPE duct can adjust with the number 15 regulator. Number 16 gauge shows duct air pressure. Minimum HDPE pipe pressure must be 10-12 bar. Figure-8 4 ) USINGTRIPOD 17 Machine is fixing or releasing on tripod by the part 17 on figure 10.Machine can easily prepare for blowing by the tripod.lenght of the tripod are adjustable and portable with special bag as in the figure 11. Figure-9 Figure-10 Figure-11