FX07 Field Controller

FX07 Field Controller

FX16 Master Controller

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Duct Humidity Transmitter

Model: DC-A2IO Advanced HVAC Controller

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

HMI display Installation Guide

Unidirectional Transmitter/ Receiver Units Introduction

IntesisBox KNX - LON

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Optimize your simple machines... Modicon M218 Selection Guide

IntesisBox KNX LG Air Conditioning

T7560A,B,C Digital Wall Module

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

IntesisBox KNX Modbus RTU master

TAC I/NETTM MR-AHU-HP. Application Specific Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

KNX Panasonic Air Conditioners

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

IntesisBox Modbus Server SAMSUNG Air Conditioners

T5000 T000 LCD Digital Fan Coil Thermostat

IntesisBox KNX Modbus TCP master

Heating Controller. Building Technologies HVAC Products

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

DCS Series 1 kw, 1.2 kw, & 3 kw

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

User manual Rev 1.3 Contents

EBS852 (Contrac) Power Electronic Unit

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rack mounted telephone- and leased line modem for industrial applications

40.3. Control Relays and Timers

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Telephone- and leased line modem for industrial applications TD-36

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Controller board and power supply for vivimat III systems

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

TAC I/NETTM. Process Control Unit

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Ordering Part Numbers:

How To Use A Ds340 (Dsp)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

QSE-CI-NWK-E Control Interface

Y7230A CO 2 Alarm System

Frequency Converter Fv

The multi-functional integrator Supercal 531

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Temperature & Humidity SMS Alert Controller

Radiant Temperature Sensor TY7321

Electric Rotary Actuator - On/Off or programmable control actuator

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

IntesisBox Modbus Server Fidelio IP

Industrial Bar Code Scanners

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Technical Data Sheet. 3DLevelScanner

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Rosemount 333 HART Tri-Loop

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

Inwall Room Temperature Unit

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

Repeaters and Mimics Data Sheet

DeltaV SISnet Repeater

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

IntesisBox KNX Mitsubishi Heavy Industries AC

Integrated Building Management and Security System. Building Automation & Security.

HERZ-Thermal Actuators

USB-500/600 Series Low-Cost Data Loggers and Accessories

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

38 Series - Relay interface modules A

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

38 Series - Relay interface modules A

Rosemount 333 HART Tri-Loop

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Modbus Server SAMSUNG Air Conditioners

How To Power A Schen

PD 100A. Printing data system

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100

Cisco Redundant Power System 2300

Transcription:

FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating, and Air Conditioning (HVAC) and Refrigeration applications. The controller has 29 physical inputs & outputs and supports a wide range of temperature sensors and actuating devices. Parameters in the control application can be displayed and modified from the optional LCD Displays. The FX14 has a state-of-the-art integral LCD display including a set of graphic status icons used in the most common HVAC/R applications and/or remote (MUI) user interfaces. The FX14 field controller can be fitted with an optional communication modules for integration into an N2 Open or LONWORKS compatible Building Automation System. The FX14 also features communications services to transmit event notification messages via Short Messaging Service (SMS). The FX14 field controller is fully configurable or programmable, using the FX Tools software package, for a wide range of commercial HVACR applications. The FX14 also includes an on-board Real Time Clock to support the start-stop scheduling of equipment and real time based control sequences. Features Modular Network communication options On-Board Real Time Clock Communication services Freely programmable or configurable using FX Tools software package Software selectable analog inputs User interfaces, integral or remote Dimensions in mm (inches) Selection Table 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - no communication card LP-FX14D10-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - N2 Open Card LP-FX14D11-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - LONWORKS Card LP-FX14D12-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - RS232C Card LP-FX14D13-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - Integral User Interface, no communication card LP-FX14D60-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - N2 Open Card and Integral User Interface LP-FX14D61-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - LONWORKS Card and Integral User Interface LP-FX14D62-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (5 Relays + 4 Triacs) - RS232C Card and Integral User Interface LP-FX14D63-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - no communication card LP-FX14D20-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - N2 Open Card LP-FX14D21-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - LONWORKS Card LP-FX14D22-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - RS232C Card LP-FX14D23-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - Integral User Interface, no communication card LP-FX14D70-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - N2 Open Card and Integral User Interface LP-FX14D71-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - LONWORKS Card and Integral User Interface LP-FX14D72-000C 6 AIs, 12 BIs, 2 AOs (0-10 V or PWM), 9 BOs (9 Relays) - RS232C Card and Integral User Interface LP-FX14D73-000C - Page 10 -

FX14 Field Controller (2/4) Communication Cards - Selection Table N2 Open Communication Card LONWORKS Communication Card RS-232C Communication Card LP-NET151-010C LP-NET142-000C LP-NET163-000C User Interfaces - Selection Table Medium User Interface (MUI) - Panel Mount Medium User Interface (MUI) - Wall Mount Link cable for the connection of the FX07 to the Panel Mount MUI display - 3 m (9.8 ft) LP-DIS60P20-0C LP-DIS60P21-0C LP-KIT007-000C Software - Selection Table FX Tools Pro CD-Rom (FX Builder, FX Builder Express, FX CommPro N2, FX CommPro LON) New User FX Tools Pro CD-Rom (FX Builder, FX Builder Express, FX CommPro N2, FX CommPro LON) Upgrade LP-FXTPRO-0 LP-FXTPRO-6 Accessories - Selection Table Link cable for the connection of the FX14 to the Panel Mount MUI display - 3 m (19 ft) Kit of female screw connectors FX Programming Key Power Supply Adapter for Programming Key: 230 VAC/12 VDC LP-KIT007-000C LP-KIT014-000C LP-KIT100-000C DT-9100-8901 Room Command Modules - Selection Table Room Sensor Modules 80 mm x 80 mm (3.15 x 3.15 in.), C (TM Series without Display) Room Sensor Module, temperature sensor only Room Sensor Module, occupancy button and LED Room Sensor Module, 12-28 C setpoint dial, occupancy button and LED Room Sensor Module, 12-28 C setpoint dial, occupancy button and LED, fan speed override Room Sensor Module, +/- setpoint dial, occupancy button and LED Room Sensor Module, +/- setpoint dial, occupancy button and LED, fan speed override Room Sensor Module, 12-28 C setpoint dial Room Sensor Module, +/- setpoint dial TM-2140-0000 TM-2150-0000 TM-2160-0000 TM-2160-0002 TM-2160-0005 TM-2160-0007 TM-2190-0000 TM-2190-0005 Room Command Modules - Selection Table Network Room Modules with Serial Bus Connection to FX07 80 mm x 80 mm (3.15 x 3.15 in.), C Network Room Module, temperature sensor only, no display, no setpoint dial Network Room Module with LCD display, temperature sensor, setpoint dial, occupancy function Network Room Module with LCD display, temperature sensor, setpoint dial, fan speed override button, occupancy function LP-NRM001-000C LP-NRM002-000C LP-NRM003-000C - Page 11 -

FX14 Field Controller (3/4) Channel Type Remark/Application Analog Input (AI) AI1, AI2, AI3, AI4, AI5, AI6 AI V Ref DI1, DI2, DI3, DI4, DI5, DI6, DI7, DI8, DI9,DI10, DI11,DI12 DO1, DO2, DO3 DO4, DO5 DO6 DO7, DO8, DO9 AO V Ref AO1 AO V Ref AO2 See table below. 16-bit resolution +16 V, 20 ma max or +5 V, 20 ma max Potential free contacts Digital Output (DO) or 0.5A, 24Vac triacs or 0.5A, 24Vac triacs Analog Output (AO) 15 VDC 10 ma max 0...10 VDC, 3 ma or PWM, 100 Hz 15 VDC 10 ma max 0...10 VDC, 3 ma or PWM, 100 Hz Freely software configurable. Application: temperature, humidity, or pressure To power directly from the FX14 Active 0..10 V Sensors or to power directly from the FX14 Active Ratiometric Sensors. The selection between the two configuration is done by jumpers Digital Input (DI) Transition counter function, Maximum 10 ms on and 10 ms off (@ 50 Hz) There is double insulation between the relays, and they can be used at different voltages from one another Voltage Reference signal used for PWM inputs of frequency drives, fan speed controllers Used to drive motor actuator, power triacs, frequency drivers or fan speed controller. 16 bit resolution Voltage Reference signal used for PWM inputs of frequency drives, fan speed controllers Used to drive motor actuator, power triacs, frequency drivers or fan speed controller. 16 bit resolution Available Sensor Types Sensor Type Linearization Range Accuracy @ 20 C (68 F) ambient Ni1000 JCI -40 C (-40 F) to 120 C (248 F) ±0.5 C (1 F) Pt1000-40 C (-40 F) to 160 C (320 F) ±0.5 C (1 F) A99-40 C (-40 F) to 100 C (212 F) ±0.5 C (1 F) NTC K10-20 C (-4 F) to 70 C (158 F) ±0.5 C (1 F) 0 to 5 VDC ratiometric 0.5 to 4.5 VDC (10 to 90% of supply voltage) ±0.05 VDC 0 to 10 VDC 0 to 10 VDC ±0.05 VDC - Page 12 -

FX14 Field Controller (4/4) Technical Specifications Product Codes Power Supply Requirements Power Consumption Protection Class Ambient Operating Conditions Ambient Storage Conditions Dimensions (H x W x D) Weight (with package) Integral LCD Display Resolution Connection Terminals for AIs, DOs and Power Supply Connection Terminals for LON/N2 Open Bus LP-FX14Dxx-000C 24 VAC ±15%, 50/60 Hz - Class 2 Power Supply SELV in Europe 19.5 VA at max load IP20 controller / IP55 integral LCD display -40 C (-40 F) to +60 C (140 F), 10 to 95% RH (noncondensing) Note that the integral user interface does not operate below -20 C (-4 F) -40 C (-40 F) to +70 C (158 F), 10 to 95% RH (noncondensing) 142 mm (5.6 in.) x 215 mm (8.5 in.) x 49 mm (1.9 in.) With display: 142 mm (5.6 in.) x 215 mm (8.5 in.) x 63 mm (2.5 in.) 0.74 kg (1.6 lb) -999 to 999 or 99.9 to 99.9 (4 digits for each row) Screw terminals for max 1 x 1.5 mm 2 (AWG16) wires, included in the package. Screw terminals, cable size up to 1.5 mm 2, AWG24 to AWG16, included in the package. Belden cable, 2-core twisted pair with shield 0.8 mm (AWG20) Connection Terminals for AOs, DIs Screw terminals, cable size up to 1.5 mm 2, AWG24 to AWG16, included in the package. and Remote Display CE Compliance 89/336 EEC directive: EN 50081-1 (EN 61000-6-3), EN 50082-1 (EN 61000-6-1) 73/23 EEC directive: EN 60730 UL Compliance UL873, UL916 - Page 13 -