ESTEC-8. Peter J. Hatton & Barry W.L. Southward



Similar documents
QGA Quantitative Gas Analyser

CATALYSIS & THERMAL ANALYSIS

Mass Spectrometers. for Gas Analysis Applications. Gas Analysis

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

Mass Spectrometers. for Gas Analysis Applications. Gas Analysis

Pesticide Analysis by Mass Spectrometry

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

13C NMR Spectroscopy

IB Chemistry. DP Chemistry Review

Page Which hydrocarbon is a member of the alkane series? (1) 1. Which is the structural formula of methane? (1) (2) (2) (3) (3) (4) (4)

Amount of Substance.

m/z

AMD Analysis & Technology AG

Getting the most from this book...4 About this book...5

Chapter 3: Stoichiometry

Question Bank Organic Chemistry-I

Analyzing Small Molecules by EI and GC-MS. July 2014

Balancing chemical reaction equations (stoichiometry)

Infrared Spectroscopy 紅 外 線 光 譜 儀

Molecular Formula Determination

Chapter 3 Mass Relationships in Chemical Reactions

Titan: The Solar System s Abiotic Petroleum Factory

Lecture 35: Atmosphere in Furnaces

How To Use Gc-Ms

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Chemistry Diagnostic Questions

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

INTI COLLEGE MALAYSIA A? LEVEL PROGRAMME CHM 111: CHEMISTRY MOCK EXAMINATION: DECEMBER 2000 SESSION m/e

Appendix 5 Overview of requirements in English

Unit Vocabulary: o Organic Acid o Alcohol. o Ester o Ether. o Amine o Aldehyde

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

F321 MOLES. Example If 1 atom has a mass of x g 1 mole of atoms will have a mass of x g x 6.02 x = 7.

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Coimisiún na Scrúduithe Stáit State Examinations Commission

Lecture 5, The Mole. What is a mole?

Chemical Equations & Stoichiometry

AS1 MOLES. oxygen molecules have the formula O 2 the relative mass will be 2 x 16 = 32 so the molar mass will be 32g mol -1

World s Best Oil in Water Analyzers

The photoionization detector (PID) utilizes ultraviolet

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Continuous flow direct water heating for potable hot water

Copyright 2007 Casa Software Ltd. ToF Mass Calibration

Chapter 3! Stoichiometry: Calculations with Chemical Formulas and Equations. Stoichiometry

Specimen Paper. Chemistry 1F. Time allowed! 60 minutes

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

Mass Spectrometry. Overview

Alkanes. Chapter 1.1

CHE334 Identification of an Unknown Compound By NMR/IR/MS

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Chapter 13 Organic Chemistry

Symmetric Stretch: allows molecule to move through space

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

2. Molecular stucture/basic

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

@ Oxford Fajar Sdn. Bhd. ( T) Matter. 1.1 Atoms and Molecules 1.2 Mole Concept 1.3 Stoichiometry

Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in. University of Applied Sciences

Ultraviolet Spectroscopy

Chapter 1 The Atomic Nature of Matter

Electrospray Ion Trap Mass Spectrometry. Introduction

Micromass LCT User s Guide

Setting up a Quantitative Analysis MS ChemStation

Bridging the analytical gap

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Trace Gas Exchange Measurements with Standard Infrared Analyzers

WRITING CHEMICAL FORMULA

For example: (Example is from page 50 of the Thinkbook)

W1 WORKSHOP ON STOICHIOMETRY

OLIVÉR BÁNHIDI 1. Introduction

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

Dissolved Gas Analysis Guide for Transformers Filled with Beta Fluid

SCION SQ Series GC-MS

Supporting Information

Question Bank Electrolysis

(a) graph Y versus X (b) graph Y versus 1/X

Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Nuclear Magnetic Resonance notes

Chemistry Post-Enrolment Worksheet

atm = 760 torr = 760 mm Hg = kpa = psi. = atm. = atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

Secondary Ion Mass Spectrometry

Chapter Three: STOICHIOMETRY

Background Information

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

The Empirical Formula of a Compound

Austin Peay State University Department of Chemistry CHEM 1021 TESTING FOR ORGANIC FUNCTIONAL GROUPS

Suggested solutions for Chapter 3

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

How To Run A Gas Plant

Chemical Calculations: The Mole Concept and Chemical Formulas. AW Atomic weight (mass of the atom of an element) was determined by relative weights.

F321 THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important are... in the nucleus of an atom

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Unit 6 The Mole Concept

Transcription:

Optimisation of the Connection Between Thermal Analysis Systems and Quadrupole Mass Spectrometer Systems Together with Improved Data Interpretation for TA-MS Applications. Peter J. Hatton & Barry W.L. Southward

Topics! Introduction Why connect thermal analysis equipment to a mass spectrometer?! The TA-MS hardware interface How is the connection made? How is the connection optimised?! The software interface How can TA and MS systems be controlled simultaneously?! Data interpretation Techniques for MS data interpretation

Introduction- Why connect TA equipment to a mass spectrometer? Data from thermal analysis equipment and mass spectrometry are complimentary. The strengths of Thermal Analysis are:! Sample environment control. Pressure, temperature, gas, vapour.! Accurate weight measurement for uptake, and decomposition. MS compliments TA techniques with speciation as a function of time and / or temperature.!the combined TA-MS data is used to characterise materials

The TA-MS Interface! Thermal analysis equipment typically operates at near atmospheric pressure.! Specialized systems operate from high vacuum to high pressure.! Mass spectrometers operate at high vacuum.! The mass spectrometer interface provides for gas/vapour sampled from directly above the sample within the thermal analysis equipment to be analysed in near real time by the mass spectrometer.! Where internal sampling is not practical the mass spectrometer can be connected to an external exhaust of the thermal analysis equipment.

QIC 20 overview

The TA-MS coupling! The QIC capillary has no cold spots and minimum dead volume providing a response time of less than 500msec.! Can the capillary be connected directly to the exhaust port of the thermal analysis equipment? Vent / Secondary Analysis Yes, OK for non-condensing species, but expect peak broadening.! An optimised coupling includes integration of the capillary into the hot zone of the TA equipment. The ideal inlet is shown opposite, as configured in Hiden s CATLAB micro-reactor. reactor. QIC capillary end assembly with alumina sampling probe adapter ¼ Swagelock union Tee with Vespel ferrules Reactor Column Alumina sampling probe Furnace / Isothermal chamber Sample / Catalyst

Hiden Hot Zone Sampling Inlet Customised adapter QIC Capillary connection Alumina capillary extension Sample gas exhaust port /secondary analysis

Effect of Cold Spot Effect of Cold Spot on Capillary Response - ipa SEM (Torr) 6.0E-08 5.0E-08 4.0E-08 3.0E-08 2.0E-08 Vapour fed 15s (QIC) or Till breakthrough (cold). Response / Recovery: QIC < 1s / 5s Cold Inlet ± 25s / 50s 1.0E-08 0.0E+00 0 30 60 90 120 Feed vapour in Time / s Cold QIC

Fast response to gases and vapours Conventional capillary inlet QIC inlet

TA-MS adaptors - example TA Instruments Dupont Cahn Setaram Netzsch Hiden IGA Mettler Toledo Seiko

Software Interface TA equipment can control the mass spectrometer and reads the mass spectrometer data through an RS232 connection. Or The mass spectrometer can read the TA equipment data, sample temperature and weight loss for example. For detailed mass spectrometer studies it is recommended to read the TA equipment data into the mass spectrometer. This allows the user complete mass spectrometer control for complex studies. Ioniser electron energy for example.

Software Interface Cont. Hiden s mass spectrometer systems can read data from TA equipment. The system includes up to 16 analog input channels for reading data d from devices, e.g. Temperature and weight. The signals from the TA equipment are conditioned to be linear 0 10V f.s.d. and can be displayed with mass spectrometer data. The MS system is started simultaneously with the TA equipment using Transistor Threshold Level (TTL) logic control.

Example TA-MS TP-Decomposition of (H 3 PW 12 O 40 ).(NH 2 (CH 2 ) 6 NH 2 ) 1.5. Simultaneous acquisition of Temperature. Data shows optimum response of gases and water with Hot-Zone / QIC

Idealised TA-MS set-up Hot-Zone sample capillary Digital signal / ASCII file QIC /ceramic sheathed ill PC HPR-20 MSIU Thermal balance Analogue signals ASCII File

TGA-MS Example Weight Loss (%) 110 100 90 80 70 60 50 40 30 Thermal Decomposition of Calcium Oxalate 100 % 88.12 % 69.86 % 39.12 % 5.0E-3 4.5E-3 4.0E-3 3.5E-3 3.0E-3 2.5E-3 2.0E-3 1.5E-3 1.0E-3 500.0E-6 Intensity 20 000.0E+0 0 100 200 300 400 500 600 700 800 900 1000 Coupled TG-MS shows: Sample Temperature ( C) i) water desorption ii) partial oxalate decomposition with CO / CO 2 evolution iii) full decomposition of oxalate with CO 2 evolution. One can also see the perfect correlation between mass loss and MS signals.

TGA-MS Example Thermal Decomposition of CuSO 4.(5H 2 O) Thermal Decomposition of CuSO 4 105 100 95 99.94 % Weight Water 9.00E-09 8.00E-09 7.00E-09 90 6.00E-09 Coupled TGA/DTA-MS of this sample showed good agreement with expected values and again reflected exact correlation between mass loss and MS signals. %-wt Loss 85 80 75 70 65 86.12 % 73.50 % 66.71 % 5.00E-09 4.00E-09 3.00E-09 2.00E-09 1.00E-09 60 0.00E+00 0 50 100 150 200 250 300 Sample Temperature ( o C) 3000 2500 Comparison of DTG and DSMS Intensity DTG Water 9.00E-09 8.00E-09 7.00E-09 Intensity DTG 2000 1500 1000 500 6.00E-09 5.00E-09 4.00E-09 3.00E-09 2.00E-09 1.00E-09 Intensity 0 0.00E+00 0 50 100 150 200 250 300 Sample Temperature ( o C)

Data Interpretation 1.1 The previous examples of TA-MS illustrate excellent coupling between the TA equipment and the Hiden mass spectrometer. This data can be viewed as calibration data proving that the sampling connection is optimised. Data from unknown samples requires interpretation. Interpretation identifies: The evolved species The temperature of evolution The abundance of evolved species. For catalysts Hiden systems include specific experimental methods and data interpretation software for the quantitative determination ion of catalyst characteristics e.g. active / metal surface areas, acid a site concentration / strength determination etc.

Data Interpretation 1.2 The NIST Mass Spectral Library contains 129,136 EI Spectra of 107,886 compounds

Data Interpretation Hiden MS data is easily imported into the NIST mass spectral database for species identification.

Data Interpretation Hiden MS data The NIST library includes search and compare facilities.

Data Interpretation 1.2 1) Identify peaks due to known components. 2) Identify all Molecular Ions / significant peaks using ms library. 3) Assign remaining peaks noting the general appearance of the spectrum, checking for peak cluster from Isotope patterns and low-mass neutral fragment loss e.g. CH 2 4) Compare to reference spectra on NIST98 database (available from Hiden Analytical). 5) Use Matrix Inversion routine or apply linear equations to calculate the gas composition.

Data Interpretation 1.3 Analysis of the Pyrolysis of Landfill Solids Once the identities of the various species have been compared the next step of the process is to construct the sets of equations necessary to determine the individual contributions at any given m/e. However for some m/e values e.g. m/e 28 which encompasses N 2, CO, and all linear and iso alkanes and alkenes, the sheer complexity of contributions are such that standard Matrix Inversion Methods are required (available from Hiden Analytical).

Data Interpretation 1.4 Analysis of the Pyrolysis of Landfill Solids However Matrix Inversion requires both knowledge of the identity of all possible components present and the calibration of their individual ividual contributions in a mixture which in this case would prove extremely ely time and labour intensive. In this case the analysis can use a simpler linear combination approach to determine the individual contributions, these values are then incorporated into a set of equations to establish the gas composition.

Data Interpretation 1.5 Analysis of the Pyrolysis of Landfill Solids Example 1: At m/e 17 the peak appears as a result of both H O (23% 2 of the peak at m/e 18) + NH. Hence: 3 NH 3 =(m/e 17-(0.23*m/e 18))/1.3) where 1.3 is the Relative Sensitivity of NH cf. N 3 2 Example 2: To calculate the N 2 concentration we cannot use the main peak at m/e 28 as indicated. Hence we derive the N concentration 2 from the m/e 14 N 2 daughter peak, corrected for the Methane overlap: N 2 =(m/e 14-(0.204*CH 4 )) * 20 NB. Methane concentration is itself derived from: CH 4 = m/e 16/1.6-(0.80*NH 3 )-((0.218*m/e 32)/0.86) where 1.3 is the Relative Sensitivity of CH 4, 1.6 is the Relative Sensitivity of CH and 4 0.86 is the Relative Sensitivity of O 2

Data Interpretation 1.6 Analysis of the Pyrolysis of Landfill Solids Example 3: At m/e 12 the peak is a result of CO (5% of the CO at m/e 28) + Ethane (1.2% of total Ethane concentration) + Ethene (0.4% of total) + Propane (0.6% of total) + Propene (2.0% of total) + Butane (0.3% of total) + Butene (0.8% of total). NIST shows no contribution from CO and 2 contributions from C 5 + hydrocarbons are ca. 0.1%, which given their low concentrations are ignored. Hence: e: CO = (20/1.05)*((m/e 12 - (0.012*Ethane) - (0.004*Ethene) - (0.006*Propane) - (0.02*Propene) - (0.003*Butane) (0.008*Butene)) Where 1.05 is the Relative Sensitivity of CO cf. N 2 NB. It was necessary to account for contributions from homologous s species e.g. all n and iso -alkanes or aromatics. This is necessary as it can be difficult to make specific assignments to fragments as members of the series display similar fragmentation patterns / contributions e.g. m/e 26 from all non-methane hydrocarbons. To account this a lumped analysis was performed. Fortunately the similarity which makes this analysis necessary also validates it, as the lumped components are highly similar chemically and calorifically.

Data Interpretation 1.7 Results Analysis of the Pyrolysis of Landfill Solids Species % Species % Species % H 2 26.76 Propane/ Propene 0.426 HC / xylene 0.174 CO 27.16 Ethane 0.937 HC fragment 0.127 N 2 3.707 O 2 0.164 HC fragment 0.017 CH 4 11.84 H 2 S 0.072 Pentene 0.021 NH 3 0.420 Cl 0.158 iso-alkenes 0.021 H 2 O 4.521 Benzene / K 0.090 iso-octane 0.023 Na 0.045 Argon 0.170 C 6 0.008 HC (C 2 s +) 2.796 n-alkenes 0.130 C 7 0.008 HC (C 2 s +) 2.696 Octane 0.096 Benzene 0.023 Ethane / Ethene 2.240 CO 2 15.15 Xylene 0.013

Data Interpretation 2.1 Soft Ionisation Hiden quadrupole mass spectrometers can simplify the analysis of otherwise complex cracking patterns from multi-component gas / vapour mixtures via the method the Soft Ionisation. What is Soft Ionisation? Mass Spectrometers use a standard ionisation energy setting (70eV) to enable identification of species using standard mass spectral libraries. Electron beam Source cage +3V Gas molecules Filament 70V Extractor 90V Quadrupole entrance aperture 0V Positive ions extracted into mass filter Soft ionisation is the use of ionising electron energy at < 70eV to preferentially ionise the parent molecule with reduced fragmentation.

Data Interpretation 2.2 Soft Ionisation- How Does It Work? This technique involves user-controlled variation of the ionising electron energy of the electrons from the ioniser filament through the normal scan tree set-up of the MASsoft program. This is made possible through the specific design of the Hiden ioniser and the precise ion source control provided by MASsoft. m/z 32 - O2 m/z 30 - NO m/z 42, 43 - CH 3 COCH 3 m/z 40 - organic NOT Ar m/z 45 - CH 3 CHOHCH 3 12 Energy (V) 10 3.5E-08 3.0E-08 2.5E-08 2.0E-08 1.5E-08 1.0E-08 5.0E-09 0.0E+00 25 27 29 31 33 35 37 39 41 43 45 47 49 Mass (a.m.u.) m/z 44 - CO 2 Partial Pressure (Torr)

Data Interpretation 2.3 Table 1 Ionisation Energies of Simple Inorganic and Organic Molecules N 2 O 2 Ar CO CO 2 NH 3 NO CH 4 Nitrogen Oxygen Argon Carbon monoxide Carbon dioxide Ammonia Nitric oxide Methane I.E. / ev 15.58 12.07 15.76 14.01 13.77 10.07 9.26 12.61 C 2 H 2 C 2 H 4 C 2 H 4 O 2 C 2 H 6 C 2 H 5 OH C 3 H 6 O C 3 H 6 O C 3 H 8 O Ethyne Ethene Acetic acid Ethane Ethanol Propanal Acetone IPA I.E. / ev 11.40 10.51 10.65 11.56 10.43 9.96 9.70 10.17 C 2 H 6 O C 6 H 6 C 6 H 14 C 6 H 12 CH 3 OH CH 2 O 2 CH 2 O CCl 4 DME Benzene Hexane (n) Methanol Formic acid Cyclohexane Formaldehyde Carbon Tet. I.E. / ev 9.72 9.24 10.13 9.86 10.85 11.33 10.88 11.47 The minimum electron energy required for ionisation is related to the electronic nature of the elements and strength of the bonds formed.

Data Interpretation 2.4 Analysis of IPA impurities in acetone is difficult due to the similarity in molecular weights, volatility and cracking characteristics. The presence of air gases (N, O, 2 2 Ar, CO 2 ) complicates the analysis. The data shows the mass spectrum of the vapour at the standard electron ionisation potential of 70eV. A cursory analysis of this figure shows the presence of > 20 peaks from parent ions / fragments, the deconvolution of which is not trivial. The spectra at 15eV and 10eV illustrate the spectral simplification obtained with soft ionisation. Partial Pressure (Torr) Partial Pressure (Torr) Partial Pressure (Torr) 1.0E-07 8.0E-08 6.0E-08 4.0E-08 2.0E-08 0.0E+00 25 30 35 40 45 50 Mass (a.m.u.) 1.0E-07 8.0E-08 6.0E-08 4.0E-08 2.0E-08 0.0E+00 25 30 35 40 45 50 Mass (a.m.u.) 1.0E-07 8.0E-08 6.0E-08 4.0E-08 2.0E-08 X10 IPA Acetone 0.0E+00 Mass (a.m.u.) 25 30 35 40 45 50 *10 70eV 15eV 10eV

Data Interpretation 2.5 Effect of Electron Energy (14-18V) on MS of C6 Isomers in Air Effect of Electron Energy (14-18V) on MS of Air 16 Energy (V) 15 14 26 27 28 29 3.0E-08 2.0E-08 1.0E-08 0.0E+00 Partial Pressure (Torr) Energy (V) 16. 15. 14V 26 27 28 29 3.0E-08 2.0E-08 1.0E-08 0.0E+00 Partial Pressure (Torr) mass (a.m.u.) Mass (a.m.u.) Conclusions. Soft Ionisation is a simple and very useful method for the simplification of the analysis of complex mixtures with component concentrations from ca. 0.1 to 100% specifically where the 1 st ionisation potential of the species vary by at least ~ 0.5 ev.

The Final Word TA-MS data from 50:50 CaOx : SrOx showing high resolution and response of the Hiden TA- MS coupling c with a response to the minor differences in de- hydroxylation temperatures / H 2 O evolution being clearly visible. Detail of CO 2 response at ppm levels.

The Final, Final Word Hiden are pleased to announce the development of an integrated High Temperature Solid Insertion Probe mass spectrometer system, for in-situ TA-MS studies in collaboration with Professor Phil Barnes of the Centre for Applied Catalysis, University of Huddersfield. 16 mm

The Final, Final Word HPR-20 with Direct, High Temperature Solid Insertion Probe

The Final, Final Word Dehydration and Dimerisation of IPA over γ-al 2 O 3 using the SIP 4.0E-09 3.0E-09 SEM: Torr 2.0E-09 1.0E-09 0.0E+00 0 100 200 300 400 500 Temperature / o C m/e 45 m/e 42 m/e 41 m/e 39 m/e 56 m/e 43

Conclusions To optimise TA-MS equipment: New equipment can be configured with optimum connections. Existing systems should be connected through customised couplings. Novel methods are available e.g. the direct solid insertion probe. Data interpretation and methods: Library search, linear combination, matrix inversion and soft ionisation techniques can be applied to identify and quantify species. Data interpretation provides catalyst characteristics, metal surface area for example