POMONA COLLEGE Sustainability Integration Office Facilities and Campus Services



Similar documents
Los Angeles Mission College Facilities Master Plan Draft Program Environmental Impact Report 3.5 ENERGY CONSERVATION AND SUSTAINABILITY.

TTU Green Standards. TTU Green Standards

Step 2: Define Project Objectives

How To Calculate Cost Of An Eco-Friendly Building

Aldrich Hall. LEED Facts. Silver 34* Case Study. Harvard Business School. Aldrich Hall Boston, MA

LEED GOLD CERTIFIED OFFICE DESIGN AND CONSTRUCTION

Sika Sarnafil World Class Roofing and Waterproofing

Designing Cabling Systems and Data Centers for Green Building Compliance. Dr. Paulo Marin, EE, MSc. Paulo Marin IT Expert

Siemens Gebze Location FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD

COMPASS bos I-A DATA CENTER

Green Buildings Guidelines for Harvard

Massport Sustainability Design Standards and Guidelines (SDG)

LEED PRESENTATION OUTLINE

LEED Canada EB:O&M existing building operations & maintenance

LEED CANADA FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS 2009 LEED CANADA FOR CORE AND SHELL DEVELOPMENT 2009 RATING SYSTEM

SOUTHERN CALIFORNIA EDISON DATA CENTER GREEN BUILDING EDUCATION: A CASE STUDY

2010 LEED Application Guide for Multiple Buildings and On-Campus Building Projects (2010 AGMBC)

SouthShore HILLSBOROUGH COMMUNITY COLLEGE

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

100% 50% 92% 99% LEED Facts PROJECT HIGHLIGHTS. Multi-occupant spaces have adjustable thermostats and lighting. Reduced water usage for landscaping

125 Mount Auburn Second Floor Office Renovation LEED-CI Silver, September 2008

How To Make A Green Building Plan

Sustainable Features. High-performance HVAC. High-performance Envelope Green Roof Day-Lighting Bicycle Infrastructure

34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory

Sustainable Construction An Education and Research Perspective

Going green in elevator and escalator design

HIGH PERFORMANCE and SUSTAINABLE BUILDINGS GUIDANCE Final (12/1/08)

Masters Series LEED. Masters Series Contributions to LEED

GREEN DEVELOPMENT PLAN Developer Name: Project Name: Address (Street/City/State) Description of Process. Goals. Design & Development Team Members Name

LEED Rating Systems for Historical Restorations

Haworth s Product to LEED Points. LEED - Commercial Interiors

Achieve increasing levels of energy performance beyond the prerequisite standard to

CITY OF FERNDALE EAGLE Checklist

Green House, Hungary

GREEN SCHOOL DESIGN (Revision no.1, Dated 07/14/2010)

Masters Series Contributions to LEED

Guide to the (Non-Residential) California Green Building Standards Code. Including changes effective July 1, 2012

How Do Smart Buildings Make A Building Green?

KEYBANK AT RAINIER TOWER- 24TH & 25TH FLOORS SEATTLE, WA Green Building Education: Case Study. Prepared for KeyBank by Callison LLC 2015 KeyCorp

Za abeel Energy City Master Plan. Dubai, United Arab Emirates

Los Angeles Union Station, CA Sustainable Neighborhood Assessment. April 22-23, 2014

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

BOMA BESt AND LEED EBOM COMPARISON

BREEAM versus LEED. White Paper first published February BREEAM versus LEED Page 1

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

Industrial Green Building Retrofit 101 Opportunities and Challenges. Light Industrial Green Building Retrofits. Why Green Retrofit?

Going for LEED Gold: SUSTAINABLE DESIGN IN THE RICHARD IVEY BUILDING

Subject: LEED information concerning SpecSeal, EZ-Path and BlazeStop Products

High Performance School Buildings Resource and Strategy Guide

BOMA BESt Assessment Overview

OFFICE OF THE STATE ARCHITECT STATE BUILDINGS PROGRAMS POLICIES AND PROCEDURES HIGH PERFORMANCE CERTIFICATION PROGRAM

The Raleigh Convention Center Raleigh, North Carolina Green Building Education A Self Guided Walking Tour

GREEN EXISTING SCHOOLS PROJECT MANAGEMENT GUIDE

The Integrated Design Process

How school facilities managers and business officials are reducing operating costs and saving money

Architect: Cigler Marani Architects

ENVIRONMENTAL, ENERGY AND TRANSPORTATION MANAGEMENT

the sustainability certification program for furniture

LEED Project Management Workshop

6 Schedule quarterly communications to keep employees involved in environmental improvements. WASTE REDUCTION REQUIRED MEASURES

Engineering East Promoting Sustainability LEED Platinum Certified

Green Warehouses & Distribution Centers

Queen Lane Addition, Philadelphia, Pennsylvania is a building of approximately 25,000 ft². The client is Drexel University.

Operating Sustainable Facilities

Sustainable Building Policy

Sustainability in construction at Creighton

SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight

Using Performance Contracting and Incentives to Accelerate Energy Efficiency Projects

Millennium Hall, Philadelphia, Pennsylvania is a Residence Hall/Dormitory building of approximately 102,680 ft². The client is Drexel University.

How To Improve A Building

GREEN SCHOOLS CASE STUDY. West Wing Elementary

THE UNIVERSITY OF TEXAS SYSTEM POLICY ON SUSTAINABILITY PRACTICES

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

Credits Overview. Slide 1

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN

DuPont Surfaces. Suitable for both horizontal and vertical applications, Corian solid surfaces and Zodiaq

UNIFIED FACILITIES GUIDE SPECIFICATIONS

The following terms should be understood prior to review of the Services Policy:

Los Angeles Community College District

LEED for New Construction & Major Renovations

Our Triple Bottom Line...

Green Globes for New Construction Pre-Assessment Checklist for Project Managers

MARQUETTE UNIVERSITY: McCabe Hall

Transcription:

POMONA COLLEGE Sustainability Integration Office Facilities and Campus Services May 200

Table of Contents NEW CONSTRUCTION/MAJOR RENOVATION Process... Design... 3 MINOR RENOVATIONS/PROJECTS Process... 4 Design... 4 APPENDICES App. A - LEED 2009 Requirements + PC Requirements... 4 iii

The following standards apply to all capital projects, including new construction, renovations, remodels, and upgrades. Upon review, specific standards may be altered by recommendation of the President s Advisory Committee on Sustainability to the President, the Board of Trustees Facilities and Environment Committee, or other person(s) or committee(s) as appropriate. New Construction/Major Renovation The following standards apply to all new construction and major renovation of buildings (requiring replacement of mechanical, electrical, and plumbing systems and replacement of over 50% of non-shell areas). Process It is important to note that before engaging in any new construction or renovation project, the College is committed to fully assessing the need for construction activity to take place. Creative reuse of facilities and the extensive use of renovations in place of new construction have been a hallmark of Pomona s building activity and will continue to be emphasized as a sustainable strategy for space utilization. >> All projects must include relevant sustainable design/operations language in all RFPs where relevant, including architects, MEP consultants, commissioning agents, and general contractors. >> A representative of the Sustainability Integration Office must be included in the following project activities: - Project Team - Interview/selection process for Architect, General Contractor, and other major contractors/ consultants - Initial sustainability workshop during project programming phase Programming >> Pomona College Campus Planning Guidelines and Pomona College Open Space and Landscape Guidelines describe how the following elements apply to various sites and districts throughout campus. These guidelines must be reviewed as the project team determines the project s sustainability objectives and green building features: - Potential for energy reductions and other sustainability benefits in site design and programming - Applicability of roof-mounted renewable energy or other sustainability-related technologies - Landscape style and irrigation technology >> During the programming phase (or early in the schematic design phase), the project team must engage in the following activities: 65 - Hold a sustainability workshop - Confirm energy budget goals - Develop project goals using Green Building Standards - Create preliminary LEED checklist and confirm Green Building Standards - Determine renewable energy integration goals - Include stakeholders, potential contractors, Savings By Design - Identify design concepts with significant operational savings - Develop preliminary life cycle cost model for building 65 These tasks are also included in the upcoming Pomona College Design Guidelines, to be finished by Summer 200. This document will be updated with confirmed language once those guidelines are completed.

>> Project managers/project teams for all projects must collaborate with the Sustainability Integration Office to produce a report describing initial sustainability goals/objectives (as well as final decisions; see Project Completion below). This report must be cataloged and available online. >> Utility rebates All projects must enroll in Savings By Design and/or other relevant rebate programs in cooperation with utilities (e.g. electricity, natural gas, water utilities) and the Project Manager must inquire about these programs during the programming phase of the project. Schematic Design/Design Development >> All projects must include relevant sustainability objectives and other sustainable design/operations language in Project Owner s Requirements, where produced. >> During the schematic design phase, the project team must engage in the following activities: 66 - Develop renewable energy goals - Refine/confirm sustainability initiatives - Life cycle cost analysis Generation of a life cycle cost report to compare design alternatives, considering systematically the impacts of building systems on each other. At a minimum, the following major building systems must be examined using life cycle cost analysis: - Mechanical: HVAC equipment and controls, energy sources - Electrical: lighting sources and controls - Envelope: roofing, insulation/mass, glazing - Develop preliminary energy model >> During the design development phase, the project team must engage in the following activities: 67 - Life cycle cost analysis update Update on life cycle cost report for whole building and decisions made on building systems and other features - Finalize energy model - Develop: - Education and communication plan - Commissioning plan - Measurement and verification plan - Evaluate materials for reuse Evaluate and inventory existing building materials for reuse, whether on the project site or other campus locations. Construction >> During the construction phase, the project team must engage in the following activities: 68 - Evaluate materials for reuse/donation Before clearout of existing facilities, the project team must walk the site to evaluate fixtures, furniture, and equipment for reuse/donation. - Develop solid waste management plan The project team must develop a solid waste management plan that details how construction and demolition wastes will be handled in a manner that reduces landfill wastes and emphasizes reuse, recycling, and reclamation. 66 These tasks are also included in the upcoming Pomona College Design Guidelines, to be finished by Summer 200. This document will be updated with confirmed language once those guidelines are completed. 67 These tasks are also included in the upcoming Pomona College Design Guidelines, to be finished by Summer 200. This document will be updated with confirmed language once those guidelines are completed. 68 These tasks are also included in the upcoming Pomona College Design Guidelines, to be finished by Summer 200. This document will be updated with confirmed language once those guidelines are completed. 2

Project completion >> All project teams must collaborate with the Sustainability Integration Office to produce a report detailing sustainability-related project features, a review of initial sustainability goals/objectives and whether they were fulfilled, and relevant life cycle cost analyses. This report must be cataloged and available online. >> Project contractor(s) must supply a report of waste management that includes the quantities landfilled, recycled, reused, salvaged, and donated, along with a breakdown of materials in each category and the destination of these materials. Design >> LEED standards + Pomona College requirements - All eligible new construction projects must strive for a minimum of LEED-NC Gold level certification. Within the LEED framework, projects must meet particular prerequisites as outlined in Appendix A LEED 2009 Requirements. - All renovation projects must use LEED-NC and the College s prerequisites (Appendix A LEED 2009 Requirements) as guidelines, with a goal of achieving Gold level equivalency. Whether certification-eligible projects apply for certification will be determined by the project team, based on assessment of financial and other impacts. >> Energy use and sources - Energy efficiency and conservation are important in programming, designing, and planning for the operations and maintenance of campus facilities. All projects must include a detailed energy model and exploration of opportunities to increase the efficiency and decrease the overall use of facilities under consideration. All projects must also include discussion of potential renewable energy applications (including solar photovoltaic, solar hot water heating, geothermal, or other relevant options) to offset facility energy use. - Any project must keep in mind the district-based energy standards described in the Energy chapter of the Sustainability Action Plan. - As described in the Pomona College Campus Planning Guidelines: Projects that increase square-footage above the existing 200 base will include a feasibility study to determine the effects of a net-zero increase in energy use and carbon emissions for the additional square-footage. The evaluation should include programmatic, aesthetic, and first and life-cycle cost considerations. >> Labs2 All relevant laboratory projects must comply with Labs2 development standards. >> Ongoing monitoring and communication All new and renovated facilities must include a comprehensive plan for building measurement and verification, ongoing commissioning activities, and a communication/education program, including meaningful monitoring of building resource use, generation of on-site energy, and other meaningful data. 3

Minor Renovations/Projects The following standards apply to all renovation projects of at least $5 million but that do not meet the threshold for new construction/major renovations standards (above). Process >> Pomona College Campus Planning Guidelines and Pomona College Open Space and Landscape Guidelines describe how the following elements apply to various sites and districts throughout campus. These guidelines must be reviewed as the project team determines the project s sustainability objectives and green building features: - Potential for energy reductions and other sustainability benefits in site design and programming - Applicability of roof-mounted renewable energy or other sustainability-related technologies - Landscape style and irrigation technology >> Sustainability workshop The project team must conduct a sustainability workshop with a representative of the Sustainability Integration Office. - Confirm compliance with Green Building Standards and Sustainable Operations and Maintenance Standards - Include stakeholders, potential contractors, Savings By Design - Identify design concepts with significant operational savings >> Life cycle cost analysis The project team must use life cycle cost analysis to compare design alternatives for major building systems, including: - Mechanical: HVAC equipment and controls, energy sources - Electrical: lighting sources and controls - Envelope: roofing, insulation/mass, glazing >> Utility rebates Renovation projects of at least $5 million that do not meet requirements for LEED- NC certification should use LEED and College standards to develop sustainability goals and plans as relevant. Projects must enroll where eligible in Savings By Design and/or other relevant rebate programs in cooperation with utilities. Laboratory-related projects must reflect Labs2 development standards, where applicable. Design >> Refer to Pomona College Sustainable Operations and Maintenance Standards for purchasing standards related to fixtures, furnishings, and equipment. 4

Appendix A LEED 2009 Requirements + Pomona College Requirements Project Checklist Sustainable Sites Possible Points: 26 PC Standard Y Prereq Construction Activity Pollution Prevention Credit Site Selection This point should be possible when developing anywhere on campus. 5 Credit 2 These points should be possible Development Density and Community 5 when developing anywhere on Connectivity campus. Credit 3 Brownfield Redevelopment Credit 4. This point is possible for many (but Alternative Transportation Public 6 not all) locations on campus from Transportation Access proximity to existing facilities. This point should be possible for Credit 4.2 Alternative Transportation Bicycle many (but not all) locations on Storage and Changing Rooms campus from proximity to existing facilities. Credit 4.3 Alternative Transportation Low- Emitting and Fuel-Efficient Vehicles 3 Credit 4.4 Alternative Transportation Parking Capacity 2 Credit 5. Site Development Protect or Restore Habitat Credit 5.2 Site Development Maximize Open Space Credit 6. Stormwater Design Quantity Control Prerequisite - MUST complete. Credit 6.2 Stormwater Design Quality Control Prerequisite - MUST complete. Credit 7. Heat Island Effect Non-roof Prerequisite - MUST complete. Credit 7.2 Heat Island Effect Roof Prerequisite - MUST complete. Credit 8 Light Pollution Reduction 6-8 Water Efficiency Possible Points: 0 PC Standard Y Prereq Water Use Reduction 20% Reduction 2-4 Credit Water Efficient Landscaping 2 to 4 2 or 4 points should be a goal for every project, in keeping with the standards College s Landscape Design Guidelines. Credit 2 Innovative Wastewater Technologies 2 4 Credit 3 Water Use Reduction 2 to 4 Prerequisite - 4 points is the goal for every project. 7-26 Y Prereq Energy and Atmosphere Possible Points: 35 PC Standard Fundamental Commissioning of Building Energy Systems Y Prereq 2 Minimum Energy Performance Y Prereq 3 Fundamental Refrigerant Management 0-9 Credit Optimize Energy Performance to 9 Prerequisite each project MUST strive for at least 0 points on this credit. 5

Credit 2 On-Site Renewable Energy to 7 See Campus Planning Guidelines for guidance on when renewable energy technologies are appropriate for campus sites. 2 Credit 3 Enhanced Commissioning 2 Prerequisite - MUST complete. 2 Credit 4 Enhanced Refrigerant Management 2 Prerequisite - MUST complete. 3 Credit 5 Measurement and Verification 3 Prerequisite - MUST complete. Measurement and verification systems must coordinate with College-wide monitoring programs. Credit 6 Green Power 2 7 Materials and Resources Possible Points: 4 PC Standard Y Prereq Storage and Collection of Recyclables Credit. Building Reuse Maintain Existing Walls, Floors, and Roof to 3 Credit.2 Building Reuse Maintain 50% of Interior Non-Structural Elements 2 Credit 2 Construction Waste Management to 2 Prerequisite - MUST complete. Campus standards require at 90% waste diversion rate. Credit 3 Materials Reuse to 2 Credit 4 Recycled Content to 2 Prerequisite - MUST complete. Projects must acquire at least one point. 3 Credit 5 Regional Materials to 2 Prerequisite - MUST complete. Credit 6 Rapidly Renewable Materials Credit 7 Certified Wood Prerequisite - MUST complete. 0 Indoor Environmental Quality Possible Points: 5 PC Standard Y Prereq Minimum Indoor Air Quality Performance Y Prereq 2 Environmental Tobacco Smoke (ETS) Control Credit Outdoor Air Delivery Monitoring Credit 2 Increased Ventilation Credit 3. Construction IAQ Management Plan During Construction Prerequisite - MUST complete. Credit 3.2 Construction IAQ Management Plan Before Occupancy Credit 4. Low-Emitting Materials Adhesives and Sealants Prerequisite - MUST complete. Credit 4.2 Low-Emitting Materials Paints and Coatings Prerequisite - MUST complete. Credit 4.3 Low-Emitting Materials Flooring Systems Prerequisite - MUST complete. Credit 4.4 Low-Emitting Materials Composite Wood and Agrifiber Products Prerequisite - MUST complete. Credit 5 Indoor Chemical and Pollutant Source Control Prerequisite - MUST complete. Credit 6. Controllability of Systems Lighting Prerequisite - MUST complete. 6

Credit 6.2 Controllability of Systems Thermal Comfort Prerequisite - MUST complete. Credit 7. Thermal Comfort Design Prerequisite - MUST complete. Credit 7.2 Thermal Comfort Verification Prerequisite - MUST complete. Credit 8. Daylight and Views Daylight Prerequisite - MUST complete. Credit 8.2 Daylight and Views Views Prerequisite - MUST complete. 3 Innovation and Design Process Possible Points: 6 PC Standard Credit. Innovation in Design: Specific Title Prerequisite - MUST complete. Credit.2 Innovation in Design: Specific Title Prerequisite - MUST complete. Credit.3 Innovation in Design: Specific Title Credit.4 Innovation in Design: Specific Title Credit.5 Innovation in Design: Specific Title Credit 2 LEED Accredited Professional Prerequisite - MUST complete. 2 Regional Priority Credits Possible Points: 4 PC Standard Credit. Regional Priority: Specific Credit - Will complete when complying with SSc7. the above. Credit.2 Regional Priority: Specific Credit - Will complete when complying with WEc3 (40%) the above. Credit.3 Regional Priority: Specific Credit Credit.4 Regional Priority: Specific Credit 56-67 Total Possible Points: 0 LEED certification thresholds: - Certified: 40 to 49 points - Silver: 50 to 59 points - Gold: 60 to 79 points - Platinum: 80 to 0 7