Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Similar documents
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Series description: Wilo-Star-Z

Zenith Solar thermal 4.5m pump station Installation manual

Series description: Wilo-Yonos MAXO

Hydraulic control unit series

Heating, air-conditioning, cooling

This instruction is valid for all ACD pump models shown on page 2

ECOCIAT. Domestic hot water heat recovery unit

Installation and maintenance instructions. Danfoss Vent

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Globo P. Ball valves Pump ball valve made of gunmetal

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Series description: Wilo-Yonos MAXO-D

SunMaxx Solar Filling Station Operating Instructions

Assisted lift operated 2/2-way solenoid valves Type EV250B

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

BERMAD Fire Protection

Plumbing and Electrical Installation Guide

Multistage high-pressure multistage centrifugal pumps

Operating Instructions for Plastic Flow Meter. Model: KSK

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

solarplus solar systems general features

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

ECOplus Solar Cylinder

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Proportional pressure regulators VPPE

Electronic Pressure Switch EDS 300

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

MEMBRANE VACUUM MINI PUMPS

Type overview. Technical data

Conlift1, Conlift2, Conlift2 ph+

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

! WARNING. Before using product, read and understand instructions.

AIR LINE VALVES AND GAUGES

Control blocks for two-hand start ZSB

Operators manual Basic water heater

Pressure transmitter For general industrial applications Model A-10

Series description: Wilo-Drain TC 40

Maintenance and Service Instruction

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

HEAVY DUTY STORAGE GAS

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Hydraulic multidisc Brake H420

Mechanical shaft seal types and sealing systems

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Laing industrial pumps

Product catalogue, pipe and sewer cleaning systems

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Turbine Flow Sensor Series VTR

IMPORTANT SAFETY NOTICE

HERZ-Thermal Actuators

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Bypass level indicator With magnetic display Model BNA

BERMAD Fire Protection

VAG Non-Return Valves

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Select Radiators Installation Guide

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

COMMISSIONING OF HVAC SYSTEMS

Operating Instructions Drill rig DRU160

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Stove-boiler for solid fuels KW Directions for use and assembling

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

Standard Hydraulic Piping Flushing Procedure

MFP14, MFP14S and MFP14SS Automatic Pumps

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Cooling system components, removing and installing

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

1. Description. 2. List of Accessories included A B C F G H

Laddomat Charging unit

Oil and Coolant Circulating Heating System. Model - OCSM

400B SERIES DIAPHRAGM PUMP

SOLAR HEATING SYSTEMS.

Cooling system components, removing and installing

Mikrotherm. Manual radiator valves. To be precise.

Refrigerant Pump. Original operating manual

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Catalogue Wilo- Stratos PARA

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Transcription:

Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating temperature (return): 120 C Medium: Water with a maximum propylene glycol content of 50% Nominal diameter: DN 16 Connections: Rp 3/4" Female Thread 3 5 6 Materials Sealings: EPDM Casing/fittings: CuZn39Pb3 (2.0401) Insulation: EPP foam Thermal conductivity: 0.038W/mK 7 12 Rp 3/4 Fig. 1 Scope of supply Pos. Description 2 Return ball valve with integrated gravity brake (40mbar), assembly dimension 123,5mm 3 Pressure gauge 4 Solar safety valve, 6bar, TÜV-certified 5 Circulation pump WILO ST 15/ 6 6 Fill/drain fitting 7 Flow indicator 1-13 l/min 11 Membrane expansion vessel connection flat sealing G ¾, male thread 12 Insulation half shell, back 13 Insulation half shell, front For maintenance tasks (e.g. replacing the pump) close the return ball valve and the shut-off in the drain fitting (Figure 1, pos.2 and pos. 6) Fig. 2 4 RRp ¾ 11 GG ¾ Fig. 3

Function of the Gravity Brake (Pos. 2) Opening pressure of the gravity brake: 40 mbar The gravity brake in integrated in the return ball valve. It is operated by turning the handle of the ball valve. Fig. 4a: Ball valve open Fig. 4b: Gravity brake open Fig. 4c: Ball valve closed To prevent gravity circulation, the valve disc should not be vented. The gravity brake is in operating position (closed). The slots in the handle are in a vertical position (Figure 4a). To fill and completely empty the solar system, open the gravity brake by turning the handle to the right. The slots in the handle are positioned at an angle of 45 (Figure 4b). Turn the handle to the right by a total of 90. The slots in the handle are in a horizontal position. The ball valve is closed (Figure 4c). Fill/Drain Fitting (Pos. 6) Use the fill and drain valves on the fill/drain fitting to fill and drain the solar system (Figure 5a). To drain the system, the slot in the spindle must be in a horizontal position (Figure 5b). Fig 5a Fig 5b Flow Indicator (Pos.7) The adjustment of the flow rate of the thermal carrier medium takes place by controlling the speed levels (I, II, III) of the circulation pump and the throttle in the fill/drain fitting (Figure 5). The flow indicator shows the set flow rate (Figure 6). The indicator range is between 1 and 13l/min. Read volume flow values at this edge of the rotameter Fig. 6

Wallmounting Fig 7

Extract from the Installation and Maintenance Instructions of the pump EC declaration of conformity We hereby declare that this unit complies with the following relevant provisions: EG machinery directive 89/392/EWG in this version, 91/368/EWG, 93/44/EWG, 93/68/EWG Resistance to electromagnetism 89/336/EWG in this version 92/31/EWG, 93/68/EWG Applied harmonized standards in particular: EN 809, EN 50 081-1, EN 50 082-1, EN 50 081-2, EN 50 082-2. Safety precautions for the operator 1. General Installation and service by qualified personnel only 1.1 Fields of application Type: ST: for solar thermal systems 1.2 Connection and output data Minimum input pressure at the air intake* at temperatures + 50 C: 0,05 bar at temperatures + 95 C: 0,3 bar at temperatures +110 C: 1,0 bar Permissible temperature range: -10 C up to + 110 C Maximum permissible ambient temperature: +40 C *These values are valid up to 300m above sea level. For higher elevations add: 0,01 bar/100m.

The minimum inlet pressure must be maintained in order to avoid cavitations noise. Permissible fluids: Water and water/glycol mixtures up to a ratio of 1:1. Glycol mixtures require a reassessment of pump hydraulic data in line with the increased viscosity and depending on mixing ratios. Only approved marks of additives with corrosion inhibitors must be used in strict compliance with manufacturers instructions. 2. Safety Rules 2.1 Safety Rules For The Operator Local regulations for the prevention of accidents must be observed. Danger from electrical energy must be excluded (conforming to local or general regulations such as IEC, VDE, etc.) 2.2 Safety Rules for Inspections and Installation Work It is the operator s responsibility to ensure that inspections and installation work are carried out by authorized and qualified personnel only, having themselves made fully conversant with these instructions. Work must principally be carried out only with the plant switched off and at complete standstill. 2.3 Abnormal Operating Conditions Operational safety of the plant is only ensured if used in accordance with these instructions. The limits stated there must not be exceeded under any circumstances. 3. Description of Product and Accessories The pump ST/STL is a solar thermal pump with special hydraulic (pump housing coated) for using in solar thermal systems. Motor overload protection is not required. The motor operates non-overloading. Speed setting: All pumps are equipped with a rotary switch in the terminal box to enable manual 3-speed control (1 = min) (2-3 = max). At minimum speed the maximum speed is reduced to approx. 40 50%. The power input is reduced to approximately 50%. 4. Sitting/Installation 4.1 Installation - Direction of fluid flow must correspond with the arrow on the pump housing (Fig. 2, pos. 1). - If using pump housings with integrated exhaust cavity it must be observed that the connection for the vent or the vent pipe is vertical (12h position). - When connecting the pump to the conduit of pipes, the pump can be secured against twisting using a spanner on the key surfaces which have been created for this purpose (Fig. 3) 4.2 Electrical wiring - Cable leads to be routed in such a way to avoid any contact with pipe work and/or pump or stator housings. - Check that the mains current and voltage comply with the data on the rating plate. - Effect all wiring according to Wiring diagram (Fig. 4). - Pump/installation must be earthed in compliance with regulations.

5. Commissioning 5.1 System filling and venting The pump is normally vented automatically after a short operational period. Short-term dry-running will not harm the pump. Direct venting of the pump, if necessary, is done according to the following procedure: - Switch off the pump, - close discharge isolating valve, - carefully slacken and remove the vent plug (Fig. 5). Beware of possibly released hot liquid or vapour, depending on fluid temperature and system pressure. Danger of scalding exists! - Carefully move pump shaft several times by means of screwdriver, - protect electrical parts from leaking water - Switch-on the pump - After 15 30 sec close vent plug again, - open isolating valve again. ATTENTION! It is possible that the pump shaft jams with the vent plug open, depending on system pressure. The pump can become extremely hot, depending on the operational state of the pump or the pipe system (fluid temperature). Danger of scalding exists when touching the pump!