Cooktop Low-Profile Ventilation Hoods



Similar documents
Wolf Ventilation Guide

Installation Instructions ERV/PRV Downdraft Vent

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

IH E Sigma Island 90

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Installation Instructions For Slider Casement Air Conditioners

REMOTE AUXILIARY AIR CONDITIONING AND AIR DISTRIBUTION SYSTEMS FOR VOLVO L-4 CHASSIS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Installation Instructions

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Electrical Wiring Technical Bulletin

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

ELECTRIC CONVECTION BUILT-IN OVEN

WS-69TB30SS (22") WS-69TB36SS (22") WS-69TS30SS (18") WS-69TS36SS (18")

MGB Chrome Bumper Conversion

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Guidelines for Earthquake Bracing of Residential Water Heaters

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Flue Installation. High Efficiency Condensing Boilers

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

DRYER VENTING SPECIFICATIONS DRYER SAFETY

BLACK TIE. Instructions Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Installation Instructions

FlexiDome Wall and Pipe Mounts VDA-WMT/PMT-Dome. Installation manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Installation Instructions

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Installation Instructions

Cabinets 101: Configuring A Network Or Server Cabinet

Installation Instructions

DBF 4XL Dryer Booster Fans

OPL BASIC. Dosing System for Professional Laundry machines. Contents

LED MOTION ACTIVATED FLOOD LIGHT

HEAT WAVE DUCT KIT KIT #

Portable Air Conditioner

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

Wiper Motor Marinco 2.5. Installation Instructions

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

Your safety and the safety of others are very important.

Ventilation Solutions Kitchens. fantech

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

CEILING CASSETTE FAN COIL UNIT

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

Guidelines for Earthquake Bracing Residential Water Heaters

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

March 14, Installation of Bay, Bow and Garden Windows

Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

OWNER S GUIDE OPERATION & INSTALLATION

Anthro Tablet Charging Cabinets

LIEBERT VNSA Installation Sheet

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Ceiling Fan Installation Instructions

CortezTM A Kichler Décor Ceiling Fan

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

DCF Optimized Rack System

DE Frame with C Series Sidelight

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Cooling Capacity CFM in. w.c. (125 Pa)

Roll-Up Door Maintenance Guide

SL280UHV SERIES GAS FURNACE WARNING

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENERAL ELECTRICAL REQUIREMENTS

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

AutoDome Easy II. VEZ Series. Mounting Manual

QT Residential Blower Metal Residential Blower


INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Transcription:

INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods

Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............ 8 Service Information........................... 18 Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified. Important Note To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: IMPORTANT NOTE highlights information that is especially important. CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed.

Wolf Cooktop Low-Profile Ventilation Hoods 3 wolfappliance.com/specs Cooktop Low-Profile Hood Installation IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf factory certified service. Read this entire installation guide prior to installation and save for the local inspector s reference. The homeowner should keep this installation guide for future reference. This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency and amperage ratings are listed on the product rating plate. IMPORTANT NOTE: Wolf cooktop low-profile hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. For ranges and rangetops, a Wolf pro ventilation hood is recommended. Wolf Cooktop Low-Profile Hood Model Number Serial Number Record the model and serial numbers before installing the ventilation hood. Both numbers are listed on the product rating plate, located on the underside of the hood, above the grease filter. The filter must be removed to access the rating plate. Refer to the illustration below. RATING PLATE Location of rating plate.

Cooktop Low-Profile Hood Specifications 4 Overall Dimensions LOW-PROFILE WALL HOODS 9 7 /8" (251) 10 7 /8" (276) 10 7 /8" (276) 5 7 /8" (149) TO 18 3 /8" (467) 7 7 /8" (200) TO 25 1 /2" (648) 29 1 /8" (740) TO 41 1 /2" (1054) 20 1 /8" (511) 31" (788) TO 48 3 /4" (1238) 20 1 /8" (511) 3 1 /8" (79) 3 1 /8" (79) 30" (762), 36" (914) AND 45" (1143) WIDTHS 17 3 /4" (451) 17 3 /4" (451) RECIRCULATING APPLICATION LOW-PROFILE ISLAND HOOD 11 3 /4" (298) 9 7 /8" (251) 9 7 /8" (251) 2 3 /8" (60) TO 14" (356) 4 3 /4" (121) TO 14" (356) 28 3 /8" (721) TO 40" (1016) 22 7 /8" (581) 30 3 /4" (781) TO 40" (1016) 22 7 /8" (581) 3 1 /8" (79) 3 1 /8" (79) 42" (1067) 21 5 /8" (549) 21 5 /8" (549) RECIRCULATING APPLICATION

Cooktop Low-Profile Hood Specifications 5 wolfappliance.com/specs Installation Considerations Wolf cooktop low-profile hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. These hoods have a telescopic flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. IMPORTANT NOTE: Wolf recommends that the bottom of the ventilation hood be installed 24" (610) to 30" (762) above the countertop. Low-profile wall and island hoods are available with an internal blower. Wall hood models CTEWH36 and CTEWH45 will require an in-line or remote blower assembly, available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Electrical Requirements Wolf cooktop low-profile ventilation hoods require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply within the shaded area shown in the installation illustration for your specific model on the following pages. IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. The blower will vary in size and is dictated by the cooking unit, the volume of air that needs to be moved and the length of the duct run. Refer to ventilation recommendations in the Wolf design guide. These hoods have an 6" (152) round duct with vertical discharge. IMPORTANT NOTE: Use only a Wolf blower with the cooktop low-profile hood. BACKSPLASH Optional stainless steel backsplashes are available in widths to match all cooktop low-profile hoods through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.

Cooktop Low-Profile Hood Specifications 6 Installation LOW-PROFILE WALL HOODS 29 1 /8" (740) TO 41 1 /2" (1054) HEIGHT OF HOOD E 5" (127) LOCATION OF ELECTRICAL 15" (381) 17 3 /4" (451) DEPTH OF HOOD 8' (2.4 m) TO 9' (2.7 m) FLOOR TO CEILING HEIGHT 30" (762), 36" (914) OR 45" (1143) WIDTH OF HOOD 24" (610) TO 30" (762) TO COUNTERTOP SIDE VIEW FRONT VIEW

Cooktop Low-Profile Hood Specifications 7 wolfappliance.com/specs Installation LOW-PROFILE ISLAND HOODS LOCATION OF ELECTRICAL THROUGH TOP OF HOOD 28 1 /4" (718) TO 41 1 /2" (1054) HEIGHT OF HOOD 21 5 /8" (549) DEPTH OF HOOD 42" (1067) WIDTH OF HOOD 8' (2.4 m) TO 9' (2.7 m) FLOOR TO CEILING HEIGHT 24" (610) TO 30" (762) TO COUNTERTOP SIDE VIEW FRONT VIEW

Cooktop Low-Profile Hood Installation 8 Ducting Options Wolf cooktop low-profile hoods may be used in a ducted or recirculating installation. For greatest efficiency, the ducted installation is recommended. Install Ductwork To reduce the risk of fire, use only metal ductwork. DUCTED INSTALLATION In a ducted installation, the hood aspirates the kitchen air saturated with fumes and odors, passes it through the grease filter and expels it to the outside through ductwork. For this installation, a ventilation hood with an internal, in-line or remote blower can be used. The in-line blower is located in ductwork between the hood and the outside. The remote blower can be mounted on the roof or, for wall hoods, an exterior wall. Wolf in-line and remote blowers are available through your authorized Wolf dealer. RECIRCULATING INSTALLATION IMPORTANT NOTE: Only low-profile hoods with an internal blower can be used in a recirculating installation. In a recirculating installation, the hood aspirates the kitchen air saturated with fumes and odors, purifies it through the grease filter and charcoal filter and returns clean air into the room. A recirculation kit is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. IMPORTANT NOTE: Unless used in a recirculating installation, ventilation hoods must exhaust to the outdoors. A 6" (152) round duct is recommended for cooktop lowprofile hoods. Use only rigid metal ductwork, do not use flex ducting. Consult a qualified HVAC engineer for specific ducting applications. Decide where the ductwork will run between the wall hood and the outside. A straight, short duct run will allow the hood to perform most efficiently. Limit the number of elbows and transitions. The duct run should be no longer than 50' (15 m). There is a possibility of noise issues, if a remote blower is used with a short duct run. Wolf recommends installing a backdraft damper in all installations. A backdraft damper is included with the hood. It is built into the transition from the hood to the duct run. Unless you are using a remote blower, a roof or wall cap must be installed. Connect ductwork to the cap and work back towards the hood. Use duct sealing tape to seal joints between ductwork sections. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area.

Cooktop Low-Profile Hood Installation 9 wolfappliance.com/specs Install Ductwork LOW-PROFILE WALL HOODS LOW-PROFILE ISLAND HOOD DUCTWORK INSTALLATION THROUGH ROOF 10 7 /8" (276) DUCTWORK INSTALLATION THROUGH ROOF 8' (2.4 m) TO 9' (2.7 m) CEILING HEIGHT 29 1 /8" (740) TO 41 1 /2" (1054) TELESCOPING HOOD HEIGHT DUCTWORK INSTALLATION THROUGH WALL 20 1 /8" (511) 28 3 /8" (721) TO 40" (1016) TELESCOPING HOOD HEIGHT 9 7 /8" (251) DUCTWORK INSTALLATION THROUGH EAVE INTERNAL BLOWER 3 1 /8" (79) 17 3 /4" (451) HOOD DEPTH 21 5 /8" (549) HOOD DEPTH 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP 8' (2.4 m) 9' (2.7 m) CEILING HEIGHT

Cooktop Low-Profile Hood Installation 10 Wall Hoods Ducted Installation Locate the electrical supply through the wall within the shaded area shown in the illustration on page 6. Install ductwork as outlined on pages 8 9. Mount the bottom panel to the hood. Attach with the four screws provided on the hinge side of the panel. IMPORTANT NOTE: If a backsplash is to be used, it should be installed prior to mounting the wall hood. Secure the hood mounting brackets to the wall studs prior to installing the backsplash. Refer to installation instructions provided with the backsplash. MOUNT HOOD TO WALL IMPORTANT NOTE: Wolf recommends that the bottom of the ventilation hood be installed 24" (610) to 30" (762) above the countertop. Draw a vertical line on the wall indicating the centerline of the hood. Mark the first two holes to be drilled in the wall. Position according to dimensions shown in illus 1 below. Drill two 5 /16" diameter holes and fit the screw anchors provided. Attach the metal bracket to the wall using the screws provided. Use the two cut-out triangles on the bracket to position it exactly along the vertical axis of the hood. Hang the hood on the bracket as shown in illus 2. Adjust the horizontal position moving the hood to the right or left so that it is properly aligned. When adjustment has been completed, without removing the hood, mark the four additional holes to be drilled in the wall. Remove the hood and drill four 5 /16" diameter holes and fit the screw anchors provided. Mount the hood to the wall using the screws provided. Mount the plate of the electrical system fixing it with three screws as shown in illus 3 below. ATTACH TELESCOPIC FLUE Assemble the three support brackets for the telescopic flue as shown in illus 4. The width of the bracket assembly can be adjusted. With screws and anchors provided, attach the bracket assembly to the ceiling so that it is positioned along the axis with the hood. ANCHORS SCREWS BRACKET 5 1 /16" (129) Illus 3. Illus 4. 13 3 /8" (340) CENTER OF HOOD Illus 1. Illus 2.

Cooktop Low-Profile Hood Installation 11 wolfappliance.com/specs Wall Hoods Ducted Installation Fit 6" (152) metal ducting (not provided) to the air vent of the hood and seal with duct tape. Refer to illus 5 below. For exhaust hoods, turn the upper flue over so that the air exhaust grid is in the lower section. WIRING CONNECTIONS Electrical connection at the hood: 1) Run Romex wire from the service panel to the hood s electrical box marked 120 V AC input. 2) Remove the cover from the electrical box and remove one knockout as shown in illus 6. 3) Secure the Romex wire to the electrical box through a conduit connector. Use wire connectors or wire nuts approved by UL or C/UL. 4) Make electrical connections at the hood. Connect white to white, black to black and green to ground. 5) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. IN-LINE OR REMOTE BLOWER WIRING Blower connection at the hood: 1) Run Romex wire from the in-line or remote blower to the hood s electrical box marked motor connection. 2) Remove the cover from the electrical box and remove one knockout as shown in illus 7 below. 3) Secure the Romex wire to the electrical box through a conduit connector. Use wire connectors or wire nuts approved by UL or C/UL. 4) Make electrical connections at the hood. Connect white to red, black to black and green to ground. 5) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. IMPORTANT NOTE: Refer to installation instructions provided with the in-line or remote blower assembly for additional mounting and wiring instructions. ATTACH FLUE EXTENSION Insert the flue extensions, setting them on the hood. Extend the upper flue to the ceiling and secure with two screws as shown in illus 8. WIRING BOX DUCTING WIRING BOX SCREWS Illus 5. Illus 6. Illus 7. Illus 8.

Cooktop Low-Profile Hood Installation 12 Wall Hoods Recirculating Installation INTERNAL BLOWER MODELS IMPORTANT NOTE: A recirculation kit is required for this installation. The kit is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Locate the electrical supply through the wall within the shaded area shown in the illustration on page 6. Install ductwork as outlined on pages 8 9. MOUNT HOOD TO WALL Follow the same instructions for mounting the hood to the wall as outlined for ducted installations on page 10. WIRING CONNECTIONS Follow the same instructions for wiring connections as outlined for ducted installations on page 11. INSTALL CHARCOAL FILTER First remove the grease filter(s). To access the filter(s), gently press up on the front edge of the bottom panel and allow it to rotate downward. Push the handle outward and pull the grease filter(s) downward to remove. Then install the charcoal filter by inserting the two filter clips in the slots and turning the filter towards the inside of the hood. Reinstall the grease filter(s) using the reverse procedure. Refer to illus 11 below. ATTACH TELESCOPIC FLUE Assemble the three support brackets for the telescopic flue as shown in illus 4 on page 10. The width of the bracket assembly can be adjusted. With screws and anchors provided, attach the bracket assembly to the ceiling so that it is positioned along the axis with the hood. Mount the flange on the hood to correspond with the air outlet point shown in illus 9 below. Fit 5" (127) metal ducting (not provided) to the air baffle of the hood and seal with duct tape. Attach the air baffle to the upper flue with four screws as shown in illus 10. Connect the other end of the ducting to the flange. GREASE FILTER Illus 11. CHARCOAL FILTER SCREWS DUCTING Illus 9. Illus 10.

Cooktop Low-Profile Hood Installation 13 wolfappliance.com/specs Island Hoods Ducted Installation Locate the electrical supply through the wall within the shaded area shown in the illustration on page 7. Install ductwork as outlined on pages 8 9. Mount the bottom panel to the hood. Attach with the four screws provided on the hinge side of the panel. Refer to illus 12 below. MOUNT HOOD TO CEILING Using the drilling template, drill holes for attaching the mounting bracket to the ceiling on the vertical side of your hood. The center line of the mounting bracket is in line with the center of the control panel. IMPORTANT NOTE: Placement of the mounting bracket is critical for proper alignment of the hood with the cooktop. Attach the mounting bracket to the ceiling using the screws and anchors provided. Refer to illus 13 below. The position of the bracket determines the final position of the hood. The side with the slot corresponds to the side opposite the controls. Assemble the plate of the electrical system fixing it with two screws and washers as shown in illus 14. HINGE BOTTOM PANEL Illus 12. 5 15 /16" (151) ELECTRICAL PLATE 5 15 /16" (151) SLOT Illus 13. Illus. 14

Cooktop Low-Profile Hood Installation 14 Island Hoods Ducted Installation ATTACH TELESCOPIC FLUE Attach the telescopic flue to the mounting bracket with four screws provided. Run the air evacuation pipe through the telescopic flue and run the Romex wire through the hole in the bracket. Adjust the height of the telescopic flue with the four retaining screws. Refer to illus 15 below. Take into account that the height of the hood is 3 1 /8" (79) and that the bottom of the hood should be installed 24" (610) to 30" (762) above the countertop. Slide the upper flue onto the telescopic flue with the slots of the upper flue facing upwards. Attach the flue to the bracket with two screws as shown in illus 16. Slide the lower flue over the upper flue, to the top and temporarily secure it in this position using adhesive tape. Raise the hood to the telescopic flue and connect the air outlet duct to the hood. Attach the hood to the telescopic flue with the four screws provided. Refer to illus 17. WIRING CONNECTIONS Electrical connection at the hood: 1) Run Romex wire from the service panel to the hood s electrical box marked 120 V AC input. 2) Remove the cover from the electrical box and remove one knockout as shown in illus 18 below. 3) Secure the Romex wire to the electrical box through a conduit connector. Use wire connectors or wire nuts approved by UL or C/UL. 4) Make electrical connections at the hood. Connect white to white, black to black and green to ground. 5) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. COMPLETE THE INSTALLATION ELECTRICAL CABLE Remove the adhesive tape and slide the lower flue downward, placing it gently onto the hood base. Installation is now complete. Install the grease filters. UPPER FLUE WIRING BOX RETAINING SCREW SCREWS Illus 15. Illus 16. Illus 17. Illus 18.

Cooktop Low-Profile Hood Installation 15 wolfappliance.com/specs Island Hoods Recirculating Installation IMPORTANT NOTE: A recirculation kit is required for this installation. The kit is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Locate the electrical supply through the ceiling and inside the area of the flue, above the mounting bracket and right of center. MOUNT HOOD TO CEILING Follow the same instructions for mounting the hood to the ceiling as outlined for ducted installations on page 13. ATTACH TELESCOPIC FLUE Insert the air baffle into the structure as shown in illus 19. Through the opening, fit the flange to the baffle. Turn the flange to secure it in place. Fit 5" (127) metal ducting (not provided) to the flange and seal with duct tape. Refer to illus 20 below. Slide the upper flue onto the telescopic flue with the slots of the upper flue facing upwards. Attach the flue to the bracket with two screws as shown in illus 16 on the previous page. Slide the lower flue over the upper flue, to the top and temporarily secure it in this position using adhesive tape. Attach the reduction to the air venting opening of the hood by pressing slightly. Refer to illus 21 below. Raise the hood to the telescopic flue and connect the air outlet duct to the hood. Attach the hood to the telescopic flue with the four screws provided as shown in illus 22. WIRING CONNECTIONS Follow the same instructions for wiring connections as outlined for ducted installations on the previous page. COMPLETE THE INSTALLATION Remove the adhesive tape and slide the lower flue downward, placing it gently onto the hood base. Installation is now complete. REDUCTION SCREWS Illus 21. Illus 22. FLANGE AIR BAFFLE DUCTING Illus 19. Illus 20.

Cooktop Low-Profile Hood Installation 16 Island Hoods Recirculating Installation INSTALL CHARCOAL FILTER First remove the grease filters. To access the filters, gently press up on the front edge of the bottom panel and allow it to rotate downward. Push the handle outward and pull the grease filters downward to remove. Then install the charcoal filter by inserting the two filter clips in the slots and turning the filter towards the inside of the hood. Reinstall the grease filters using the reverse procedure. Refer to illus 23. GREASE FILTER CHARCOAL FILTER Illus 23.

Cooktop Low-Profile Hood Installation 17 wolfappliance.com/specs In-Line and Remote Blowers BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instructions provided with each blower assembly for additional mounting and wiring instructions. Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. The duct run should be no longer than 50' (15 m). Remote blowers should be located between wall studs or roof rafters. Avoid pipes, wires and other ductwork. Allow enough space for transitions needed between the blower and connecting ductwork. For best performance, locate transitions nearest the blower. Refer to the illustrations below for overall dimensions of Wolf in-line and remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications. These instructions can also be found on our website, wolfappliance.com/specs. IN-LINE AND REMOTE BLOWER DIMENSIONS 11 3 /4" (298) 18 1 /2" (470) 21 1 /2" (546) 600 CFM in-line blower. 4 1 /2" (114) 24 3 /8" (619) 12 1 /4" (311) 28 1 /4" (718) 10" (254) DIAMETER 20 3 /4" (527) 15 1 /2" (394) 24 1 /2" (622) 14" (356) 24 3 /4" (629) 4 3 /4" (121) 600 CFM remote blower.

Service Information 18 Troubleshooting IMPORTANT NOTE: If the ventilation hood does not operate properly, follow these troubleshooting steps: Verify that electrical power is being supplied to the ventilation hood. Check electrical connections to ensure that the installation has been completed correctly. Refer to the troubleshooting guide in the Wolf cooktop low-profile ventilation hoods use & care guide. If the ventilation hood still does not operate properly, contact Wolf factory certified service. Do not attempt to repair the hood yourself. Wolf is not responsible for service required to correct a faulty installation. Service Information If service is necessary, maintain the quality built into your ventilation hood by contacting Wolf factory certified service. For the name and number of Wolf factory certified service nearest you, check the contact & support section of our website, wolfappliance.com or call Wolf customer care at 800-222-7820. When calling for service, you will need the model and serial numbers of the ventilation hood. Both numbers are listed on the product rating plate, located on the underside of the hood, above the grease filter. The filter must be removed to access the rating plate. Refer to the illustration below. RATING PLATE Location of rating plate.

The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc. (collectively, the Company Marks. ) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.

WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820 816999 REV-B 9/2012