SNMP Management of KIV-19s using the. TELEGRID KIV-19 Remote SNMP Proxy (KRSP TM )



Similar documents
NetScanner System. Toronto: , Montreal: , Toll Free: ,

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

An Overview of SNMP on the IMG

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Expanding DoD Network Management Secure Multi-web Remoting Tool (SMRT) 1 Abstract. 2 Network Management Systems

Emerson Smart Firewall

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Title Page Web/SNMP Management SmartSlot Card

PE6108/PE6208/PE8108/PE8208

SNMP I/O Devices Make Monitoring Environmental Conditions Easy. Austin Lin Product Manager Wayne Chen Technical Service Moxa Inc.

Dominion PX. General Questions. What is Dominion PX (PX)?

Network Management Card. User Manual

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Job Aid Pre-Installation Information S8500 Media Server

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

1 Serial RS232 to Ethernet Adapter Installation Guide

Meraki MX50 Hardware Installation Guide

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P.

The ABCs of SNMP. Info Sheet. The ABC of SNMP INTRODUCTION. SNMP Versions

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Olson Electronics Remote Power Monitoring Meter

Loop-IP6702 TDMoEthernet

TP-LINK L2 Managed Switch

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

Trademark Credits. How to Contact Us. Warranty. How to Get Support

FMUX04 SNMP Tutorial

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E.

integrated lights-out in the ProLiant BL p-class system


SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

UPS Network Interface. Quick InstallationGuide

AT-S84 Version ( ) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes

enervista UR Setup Software Quick Connect Instructions:

3.5 EXTERNAL NETWORK HDD. User s Manual

Cisco TelePresence Video Communication Server Starter Pack Express Bundle

Installation and Operation Guide

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL

SOHOware Long Reach Ethernet (LRE) Solution

Network Power Manager. User Manual

Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

NGSS Data Consolidator (DC)

Chassis, Power Supply, and Element Management

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

FRM301 SNMP Upgrade Procedure

SNMP Network Management Concepts

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

TP-LINK. Gigabit L2 Managed Switch. Overview. Datasheet TL-SG3216 / TL-SG

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P.

Net Optics Learning Center Presents The Fundamentals of Passive Monitoring Access

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

Table of Contents. Cisco Fault Management of ONS Using Simple Network Management Protocol

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

User s Manual Network Management Card

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

Environmental Management System

QuickSpecs. Models. Features and benefits Configuration. HP VCX x3250m2 IP Telecommuting Module. HP VCX x3250m2 IP Telecommuting Module Overview

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

Expert Power Control NET 4x 8212 / 8213

SNMP Web Management. User s Manual For SNMP Web Card/Box

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV ) (FA ) (7-12)

SCS3205/4805 Quick Start Guide

Flexible Converged Services System Type 1 Encryption Hub (FCSS-T1E Hub)

Configuring the Switch with the CLI-Based Setup Program

SNMP -overview. Based on: W.Stallings Data and Computer Communications

Ixia xstream TM 10. Aggregation, Filtering, and Load Balancing for qgbe/10gbe Networks. Aggregation and Filtering DATA SHEET

VAC 50/60Hz Power Adapter

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Consolidating HFC Device and Network Management and Monitoring under SCTE HMS SNMP

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

H.264 Internet Video Server

Product Guide CM-Relay

Simple Network Management Protocol

Prestige 660R-6x Read Me First

VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR NETWORK SWITCHES TEST PLAN

USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13

Innovative Electronics for a Changing World INDEX

Computer Cabinet Environment Monitor

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG

HDMI / Video Wall over IP Transmitter with PoE

Alarm Messages Clearing the Hardware Alarms How to Log On Summary Page Navigation Menu... 24

TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots

Comparison of SNMP. Versions 1, 2 and 3

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

BridgeWay Fixed Base Radio Telecom VoIP Gateway

TrueAlarm Fire Alarm Systems

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Integration of DTV Recorder Generator DVRG into a TCP/IP Network

PLI-3310 HomePlug Pro Power Bridge

ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch

Product Guide. Product Guide 2014 EMKA, Inc. Page 1 of 12

AP-GSS3000 TM 512Ch GSM SIM Server

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Transcription:

SNMP Management of KIV-19s using the TELEGRID KIV-19 Remote SNMP Proxy (KRSP TM ) By: Igal Sharret President, TELEGRID Technologies, Inc. ABSTRACT Modern Network Management Systems (NMSs) utilize the Simple Network Management Protocol (SNMP) to perform monitor and control (M&C) functions of devices and equipment in communications installations. To support this functionality, most of today s advanced communications and networking products include a built-in SNMP agent and provide a Management Information Base (MIB). The SNMP agent acts as the interface between the managed device and the NMS. The MIB, integrated into the NMS, defines the set of objects in the managed device that are monitored and controlled by the agent. Legacy devices, on the other hand, rarely have a built-in SNMP capability and in most cases do not even have an Ethernet port to facilitate a connection to the NMS. Consequently, legacy devices are often left out of automated NMSs and are relegated instead to manual monitor and control by operations personnel. This not only increases operating costs due to the need for additional personnel but also degrades overall performance by adding time delays to alarms and fault conditions that would otherwise be instantaneously detected by an automated NMS. A proven solution to this problem is to use an external custom SNMP agent and to provide a custom MIB that would allow full integration into any NMS. This paper describes one product in a family of TELEGRID products developed specifically to support the ubiquitous KIV-19/KIV-19A Trunk Encryption Device (TED). This product, called the KIV-19 Remote SNMP Proxy (KRSP TM ), was developed for the US Army CECOM and is deployed in the tactical Network Operations Vehicle (NOC-V). The KRSP TM agent is fully SNMPv1 compliant in accordance with RFC 1157 (SNMPv3 compliance will be available on December 15, 2006). The KRSP TM agent and MIB are fully compliant with SMIv1 (Structure of Management Information) in accordance with RFC 1155. The KRSP TM can be easily modified to accommodate other legacy devices as needed. 1. INTRODUCTION Network management technologies and Network Management Systems (NMSs) have made considerable progress in the last few years in managing equipment and systems that are part of small and large communications assemblages. In no other place is this more 1

prevalent than in military and Government communications sector where network-centric operations philosophy is being applied across the board. In that arena the benefits of highly networked Command, Control, Communications, Computers and Intelligence (C4I) systems have been fully recognized and are being pursued aggressively. Consequently, modern and future tech-control facilities, Tactical Operations Centers (TOCs) and Command Posts (CPs) will reflect this philosophy by allowing full visibility and full control of all equipment and systems and by automating many of the functions performed today by trained personnel. A key technology used in performing the monitor and control (M&C) functions in NMSs is the Simple Network Management Protocol (SNMP). SNMP is the networking protocol used for communications between the NMS and managed devices. It is part of the TCP/IP suite of Internet-standard protocols and is defined in RFC-1157. Most of today s advanced communications and networking products have a built-in hardware/ software SNMP agent which forms the physical and lower level interface between the device and an NMS. These products also include a Management Information Base (MIB) which defines the set of objects that the SNMP agent can monitor and control. The MIB is designed to be loaded onto and becomes part of the NMS. Legacy devices and equipment, on the other hand, do not have built-in SNMP agents and do not include a MIB. In most cases they do not even have the physical Ethernet port to allow them to connect to the NMS s Local Area Network (LAN). For these devices special steps must be taken in order to support this capability externally. These steps involve the used of an external product which includes a custom SNMP agent and a custom MIB. One such legacy device is the KIV-19/ KIV-19A Trunk Encryption Device (TED), herein referred to as KIV-19. This product has been used universally for many years by military and Government organizations to encrypt serial data streams in various communications links at rates up to 13 Mbps. Since the KIV-19 was developed prior to the age of networking and SNMP, it does not have a built-in agent or the capability to be incorporated into a modern NMS. As a result, KIV-19s are often left out of automated NMSs and are relegated instead to manual monitor and control by operations personnel. This not only increases operating costs due to the need for additional personnel but also degrades overall performance by adding time delays to alarms and other fault indicators that would otherwise be instantaneously detected by an automated NMS. In large installations where large banks of KIV-19s are used to service numerous communications links the situation becomes even more severe. TELEGRID developed the KIV-19 Remote SNMP Proxy (KRSP TM ) specifically to address these KIV-19 shortcomings. The product includes a hardware SNMP agent which connects to several KIV-19s and has full visibility of all the available KIV-19 2

monitor and control functions in each device. The KRSP TM also includes a MIB that allows incorporation into any commercial NMS. For stand-alone applications, the KRSP TM includes a software manager which, when loaded onto a laptop or workstation, functions as a complete stand-alone NMS with a full Graphical User Interface (GUI). The KRSP TM was developed for the US Army CECOM and is deployed in a tactical environment in the Network Operations Vehicle (NOC-V). In that configuration the KRSP TM also monitors other non-snmp devices such as three (3) Uninterruptible Power Supplies (UPSs) and a Temperature/ Humidity Sensor. TELEGRID s family of KRSP TM includes several different models as shown in Section 4. This paper focuses on KRSP TM Model RSP-116 which supports up to sixteen (16) KIV-19s as shown in Figure 1 below. KIV-19 #1 KIV-19 #2 KRSP Agent SNMP Traffic Over Ethernet Overall Network Management System (NMS) KIV-19 #16 KRSP Manager (on Workstation) Figure 1 - TELEGRID KRSP TM Model RSP-116 Architecture 2. KRSP TM CAPABILITIES The KRSP TM Model RSP-116 manages up to sixteen (16) KIV-19s simultaneously. Each KIV-19 connects directly to an individual DB-15 connector on the rear panel of the KRSP TM agent. The pinout of each connector has a one-to-one correspondence to the pinout of the DB-15 CONTROL connector on the rear panel of the KIV-19 Mounting Rack. This allows a simple straight-through ribbon cable to be used to interconnect the two devices. For each KIV-19 the KRSP TM monitors the following four signals which are accessible on the CONTROL connector of the KIV-19 Mounting Rack: POWER ON ALARM FULL OPERATION 3

RESYNC ACHIEVED Changes in these signals are detected by the KRSP TM agent and reported to the NMS using SNMP traps. The NMS can also request the status of these signals using SNMP Get queries. For each KIV-19 the KRSP TM agent invokes the following four commands which are accessible on the CONTROL connector of the KIV-19 Mounting Rack: RESTART ZEROIZE CHANGE KEY RESYNC These commands are issued in response to SNMP Set queries issued by the NMS. The KRSP TM agent s front panel includes a switch which can disable commands received from the NMS in order to enhance system security. A KRSP TM agent can be managed by up to five (5) separate remote NMSs that are registered with the agent as valid managers during the set-up process. Agents only communicate with managers that have been registered as valid managers. The agents security protocol will drop all packets arriving from managers which are not on the valid manager list. 3. KRSP TM COMPONENTS The KRSP TM includes a hardware SNMP agent and a MIB used to incorporate the KIV- 19 into any NMS. The KRSP TM also includes a software stand-alone manager that can be loaded onto a laptop or workstation to allow stand-alone management of devices when a fully functional NMS is not being used. 3.1 The KRSP TM Agent The KRSP TM Model RSP-116 SNMP agent is housed in a 1U small form factor chassis. The rear panel of the agent has sixteen (16) DB-15(F) subminiature connectors that accommodate connections to the KIV-19s. It also has an Ethernet RJ-45 connector that interfaces to the NMS LAN. The physical layer interface is Ethernet 10/100Base-T. The KRSP TM agent enclosure is constructed from 0.060 inch Aluminum material and has the dimensions of 17.25 inch X 12.00 inch X 1.70 inch. The front panel of the Agent is composed of 0.120 inch Aluminum material and has the dimensions of 19.00 inch X 1.70 inch. These dimensions constitute a 1U rack space. The front panel of the KRSP TM agent contains the following switches, connectors and indicators: POWER Switch 4

Used for controlling power to the internal agent s electronic circuitry. CONSOLE Port A DB-9(F) subminiature connector used during agent s configuration. COMMAND ENABLE Switch A toggle switch used to disable sending commands to the KIV-19. Monitoring of the KIV-19 signals is not effected by this switch. Space for Agent ID A white area allotted for entering an agent s name or number used to identify it to the manager. The rear panel of the KRSP TM agent contains the following switches and connectors: KIV-19 Connectors Sixteen DB-15(F) connectors used to connect up to sixteen KIV-19s to the KRSP TM agent. Ethernet Port An RJ-45 connector used to connect the Agent to the Ethernet LAN of the NMS. RESET Switch A recessed push-button switch used to reset the agent to its factory default state. The KRSP TM agent operates from AC power input of 90-264VAC 47-63 Hz. Other input power options are available. 3.2 The KRSP TM MIB The KRSP TM Model RSP-116 MIB defines a set of objects which the NMS can use to monitor and control up to sixteen (16) KIV-19s. The MIB explains what each object is and how the NMS can use these objects to not only obtain a full picture of the status of a device but also to control the device. The objects are termed Object Identifiers (OIDs) and are paired with a typed variable to create a Variable Binding (Varbind). The Varbind is used in all SNMP messages to request and receive specific information about each object contained in the MIB. For example, the defined KIV-19 objects include: KIV-19 ALARM status, FULLOP status, etc. These objects are arranged hierarchically into the rows of tables such that each row represents a unique set of objects for each managed KIV-19. Additionally the MIB defines a set of objects used to monitor and control the KRSP TM agent itself. For example, these defined objects include: agent s IP address and subnet mask, list of valid managers, etc. All objects are defined for maximum usability in the NMS. Rigorous definitions are set for each object in the MIB, which fully characterize how the objects are to be used and what responses the NMS should expect from the KRSP TM agent. This eliminates all guesswork as to how the KRSP agent behaves and allows the Network Administrator (NA) to set up simple rules to process the information that the KRSP TM agent provides. This allows not only ease of use, but straightforward integration into any NMS. 5

The MIB is fully compliant with the Structure of Management Information Version 1 (SMIv1, RFC 1155) and will compile error-free into the MIB database of any NMS. 3.3 The KRSP TM Stand-Alone Manager A stand-alone manager is provided with the KRSP TM Model RSP-116 for situations where no other NMS is used. Several agents can be supported by a single stand-alone manager. The manager, designed to reside on a laptop or workstation, includes a Graphical User Interface (GUI) that provides the operator with full network management functionality. The GUI is designed to resemble a Windows-style desktop. Agents, and their associated monitored devices, are displayed as icons on the desktop with devices displayed hierarchically under their respective agent. These icons are color-coded to indicate the device s current status. The GUI presents the operator with an at-a-glance view of all agents and managed devices, allowing for immediate error identification and a vehicle for quick response. The KRSP TM stand-alone manager automatically organizes system information first by agent and then by managed device. The GUI allows for one-click access to Get/Set data, performing all lengthy SNMP operations in the background. This information is presented graphically, avoiding the need to decipher long OIDs or to decode traps or responses to queries. 4. SUMMARY The TELEGRID KRSP TM family of products provides the capability of incorporating KIV-19s into any commercial NMS. It does that through an external SNMP agent and a MIB that were custom-designed to manage several KIV19s simultaneously. The KRSP TM Model RSP-116 discussed in this paper supports up to sixteen (16) KIV-19s. It allows them to be automatically managed by an NMS thus eliminating the need for onsite monitor personnel and speeding up the response to alarms and fault conditions. The 1U small form factor chassis of the KRSP TM agent supports easy installation in a KIV-19 rack and the connectors configuration allows for simple cable connections between each KIV-19 and the KRSP TM agent. The internal architecture of the KRSP TM supports easy customization in order to accommodate other legacy devices that may have to become part of the NMS. The following KRSP TM models are available: 1. KRSP TM Model RSP-100 manages 3 KIV-19s, 3 UPSs and a Temperature/ Humidity Sensor in a 1/3 U chassis. 2. KRSP TM Model RSP-104 manages 4 KIV-19s in a 1/3 U chassis. 3. KRSP TM Model RSP-116 manages 16 KIV-19s in a 1 U chassis. 4. KRSP TM Model RSP-704 manages 4 KIV-7s in a 1/3 U chassis. 5. KRSP TM Model RSP-716 manages 16 KIV-7s in a 1 U chassis. 6