DESIGN SPECIFICATION P/N 97010003-1 Manchester - ARINC 429 Adapter



Similar documents
AMS 2000, ALTITUDE ALERT SYSTEM

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

with Electronic Assistant

Agilent X/P/K281C Adapters

Installation Instructions

Co-location Interconnect Power Panel (CIPP) Installation Guide

INSTALLATION & SERVICE MANUAL. Display Panel

AIS-450 SYNCHRO CONVERTER

12V Dimmable Driver EL-TMDRVR

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Manual for Fire Suppression & Methane Detection System

Tactical Radio Adapter

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

ViZion Installation Guide

CDI-S100 SERIAL INTERFACE CARD

R60 USB to CAN interface Manual (1.5 EN)

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Absolute Rotary Encoder E6CP

PROXIMITY CARD READERS C-10, C-20, C60, C70

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

T-Extender E-Extender

MODEL 9020 & 9020-OEM CORRATER TRANSMITTER USER MANUAL

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

ATS Overhead Table Shelf System INSTRUCTION MANUAL

The Do s and Don ts of Pressure Transducers

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

MCR1900 Media Converter 19-Slot Chassis

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Trigno/Vicon System Integration

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

USER MANUAL. Kramer Electronics, Ltd. Models:

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Advantium 2 Plus Alarm

TrueAlarm Fire Alarm Systems

PS 155 WIRELESS INTERCOM USER MANUAL

Series 6000 Torque measured metal bellow coupling

TDAS G5-DB Hardware User s Manual

How To Power A Schen

FTW Wireless Monitoring System Reference Manual Part Number

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

DVI DA2 and DVI DA 4 User Guide

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PM Place Intercom System Operation and Installation Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Series 90 Series 90HV

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Inductive Proximity Sensors

TRIPLE-TRACK ASIC DEVELOPMENT PCB TECHNICAL REFERENCE MANUAL

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

UCC 1 USB-CAN CONVERTER

AU-110 racking guide NBXPN: 023

8-Port E3/DS3 ATM Line Card Overview

RAY-MAX Integrated Solar Power Strip

Description. Dimensions. Features. precision works better

QR12 (1.22 ) Diameter Optical Encoder

Hi5. HD-SDI/SDI To HDMI Video and Audio Converter User Manual. December 17, 2008 P/N For Hi5 Serial Number or Later

GEU Port Gigabit Switch

THE MOST FLEXIBLE NETWORK CONNECTIVITY SOLUTION

Sound Quality. Sound Engineering. PM1200. Panel Mounted Intercom with IntelliVOX for High Noise Application

How To Test A Power Distribution Unit

Product specifications

Servo Info and Centering

TOA 900 SERIES II MIXER POWER AMPLIFIER

Pmod peripheral modules are powered by the host via the interface s power and ground pins.

Parallel Redundant Uninterruptible Power Supply

Magnetic proximity switches

VOIP-500 Series Phone Quick Installation Guide

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

F2400 FOM II Series Fiber Optic Modem Technical Manual

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

How To Plan Out An Array Of Solar Panels

Allen-Bradley HP AC Line Filter Kit

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

MS900AC-B-LS User Information

Cabling Specifications

About the HotWire Slot Standalone Shelf

User Guide Ku Band Solid State Amplifiers SSPA Redundant Configuration

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

USER MANUAL. Kramer Electronics, Ltd. Models:

2015 PRICE LIST. PRICING EFFECTIVE JULY 06, Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15

Honeywell Primus HF 1050 HF Radio System

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Part Name/Description Part Number Quantity. Power Cable

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Solid State Timers Type F

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

FIRERAY 2000 Installation Guide

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

PCb Cable mount twinax. ConneCtorS

Transcription:

DESIGN SPECIFICATION P/N 9700003- Manchester - ARINC 429 Adapter Skylight Avionics 38629 6th Street East Palmdale, California (66) 265-0497

INDEX Section i. ii. iii. iv. v. vi. vii. Title OPERATING INSTRUCTIONS EQUIPMENT LIMITATIONS MAJOR COMPONENTS SPECIFICATIONS INSTALLATION PROCEDURES & LIMITATIONS INSTALLATION MECHANICAL INSTALLATION ELECTRICAL Page 2 3 4 5 (v-) (vi-) (vii-) ILLUSTRATIONS Title INTERCONNECT BLOCK DIAGRAM MECHANICAL DRAWING INSTALLATION DRAWING 4 5 CTRL # 9700003, Date: 3/25/97 Page - i

i. OPERATING INSTRUCTIONS The Unit, by it s design has no independent operating instructions. Being an integral part of the on board Air Data Computer output bus, the operating instructions for that system will need to be followed. ii. EQUIPMENT LIMITATIONS The unit converts the ADS-80 s, Manchester Encoded output to ARINC-429 Format. The adapter being a Digital to Digital Adapter is limited to the outputs of the ADC. The available Labels and Data Updates are dependent to the ports accessed. The design of the unit is such as to cause minimal degradation of the input signal and to convert the data in the fastest and most accurate means possible. Equipment Supplied. Part Number 9700003- Equipment Required But Not Supplied iii. MAJOR COMPONENT 4 Standard Mounting Screws Determined By Install Connector Standard DA 25S AMP P/N 205208- or equivalent Back Shell with retainer. AMP P/N 7452-2 or equivalent Interconnect Block Diagram ADC - 80 Skylight Avionics ARINC- 429 Manchester Manchester to ARINC Air Data Labels, -3 P/N 9700003- Input Port (Illustration iv-) CTRL # 9700003, Date: 03/25/97 Page -

iv. SPECIFICATIONS SPECIFICATION CHARACTERISTICS Physical Dimensions: Height.30" Length 4.205" Width 4.7" Weight lb. Temperature Range Start Up Operation Storage -20 C to +70 C -40 C to +70 C -55 C to +85 C Altitude Power Requirements 50,000 ft. 28 VDC @.3A Nominal Digital Inputs Manchester Labels: to 3 Outputs ARINC 429 Labels: 02, 203, 204, 205, 206, 207, 20, 2, 22 and 23 Accuracy Limitations: +/- LSB of Input Limited to the Manufactures specifications of the units making up the interface. CTRL # 9700003, Date: 3/25/97 Page - 2

. INTRODUCTION v. INSTALLATION PROCEDURES This section contains information relative to the installation of the adapter to assure satisfactory performance of the unit. (See Sections "6" and "7" for detailed mechanical and wiring diagrams.) 2. UNPACKING AND INSPECTING EQUIPMENT After unpacking the unit, make a visual inspection of the unit for evidence of damage incurred during shipment. If claim for damage is to be made, save the shipping container to substantiate the claim. 3. PREINSTALLATION CHECK Perform a continuity and power check on the wiring harness before connecting equipment. 4. POWER REQUIREMENTS The adapter operates from a standard 27.5 VDC provide circuit protection with an in line AMP breaker on the 27.5 VDC 5. POST INSTALLATION CHECK There is no in-aircraft adjustment required for the unit. All alignment and adjustment procedures are accomplished during bench maintenance. Follow the manufactures check out procedures of the on board systems, to determine indications being driven by the unit are accurate. 6. PREFLIGHT CHECK Follow the manufactures check out procedures of the on board systems, to determine indications being driven by the unit are accurate. CTRL # 9700003, Date: 3/25/97 Page - 3

vi. INSTALLATION MECHANICAL DIAGRAMS The adapter is designed for flat mounting anywhere on board the aircraft, pressurized or unpressurized compartments. The unit has four (4) mounting holes for number (6) size screws. (NOTE: Screws and other miscellaneous mounting hardware are NOT included with unit. MECHANICAL DRAWING Manchester-ARINC429 P/N 9700003 MODS S/N SKYLIGHT AVIONICS PALMDALE, CA. Made in USA 3.70 4.7000.3 3.85 4.205 Unit Connector - DB-25P, Mate - DB-25S Mechanical Drawing of 9700003- (Illustration vi-) CTRL # 9700003, Date: 3/25/97 Page - 4

vii. INSTALLATION ELECTRICAL Manchester Hi 4 Manchester Lo Shield 2 Shield 429A Out 2 429B Out 3 28VDC 8 A 28Vdc Avionics Power Gnd 9 P/N 9700003-: Pin Out (Illustration vii-) CTRL # 9700003, Date: 3/25/97 Page - 5