Recovery of Plant Waste Heat by a Thermoelectric Generating System



Similar documents
Development of High-Speed High-Precision Cooling Plate

Development of Grid-stabilization Power-storage Systems Using Lithium-ion Rechargeable Batteries

Fossil fuel heating equipment

Half the cost Half the carbon

Failure code manual. content

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

A Practical Guide to Free Energy Devices

Description of Thermal Oxidizers

Power Management of Cell Sites

Diagnostics for Mobile Homes: HVAC

LG Electronics AE Company, Commercial Air Conditioning

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Air Conditioning Sign-Off Sheet

PART 11: START-UP PROCEDURES FOR THE INSTALLER

HEATER, AIR CONDITIONING AND VENTILATION

Evaluate, Clean, and Tune Guidance

Dynamic test environment for fuel cells From stack to vehicle energy system

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Overheating limit control

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

HEAT INTERFACE UNITS (Modular)

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Air Conditioning System

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

GAS HEATING IN COMMERCIAL PREMISES

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

ECOCIAT. Domestic hot water heat recovery unit

HEAVY DUTY STORAGE GAS

HP switch LP switch Discharge thermo Comp. Surface thermo

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

High Power Programmable DC Power Supplies PVS Series

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Hydraulic Control Solutions

Fundamentals of Mass Flow Control

IGEMA BOILER LEVEL & TDS CONTROLS

Continuous flow direct water heating for potable hot water

High-efficient gas boiler CompactGas

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

CRAC Precision climate control units for data centres

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Final Report by Air Conditioner Evaluation Standard Subcommittee, Energy Efficiency Standards Subcommittee of the Advisory Committee for Natural

Solar Hot Water Heaters

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Builder Specifications for Solar Ready Homes

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

HVAC Processes. Lecture 7

Electric Coolant Pumps. Always at the Correct Temperature


POWER GENERATION AND DISTRIBUTION SYSTEM DESIGN FOR THE LEONIDAS CUBESAT NETWORK

Thyristor-controlled power supplies and battery chargers

DTC B1423/23 Pressure Sensor Circuit

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

TABLE OF CONTENT

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

A Promising Energy Source for Portable MEMS Devices

SL280UHV SERIES GAS FURNACE WARNING

Advanced gas carburizing technology for the automotive industry

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SOLAR POWER. Information Book

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

ngenieros Ingenieros Asociados De Control S.L.

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

Factory owners must ensure the boiler is:

14. Troubleshooting Guide

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

User s Manual Before using the inverter, you need to read and save the safety instructions.

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

13.10: How Series and Parallel Circuits Differ pg. 571

ECOplus Solar Cylinder

RPV - RP - RA air handling units

Li-ion Rechargeable Battery. Specification

Mixing Sodium and Lead Battery Technologies in Telecom Applications

A.Pannirselvam*, M.Ramajayam, V.Gurumani, S.Arulselvan and G.Karthikeyan *(Department of Mechanical Engineering, Annamalai University)

Power Feeding Equipment for Optical Submarine Cable Systems

1 DESCRIPTION OF THE APPLIANCE

Test Code: 8297 / Version 1

Electric & Gas Water Heaters

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Certified HVAC - Refrigeration Training Program

Free piston Stirling engine for rural development

Apartment and Communal Heating Solutions

Hydrogen as a fuel for internal combustion engines

8 Ways Power Optimizers are Better by Design

Transcription:

Technical Paper Recovery of Plant Waste Heat by a Thermoelectric Hiromasa Kaibe Takeshi Kajihara Shinichi Fujimoto Kazuya Makino Hirokuni Hachiuma From October 2009, KELK started verification tests of a thermoelectric generating system using a carburizing furnace at the Awazu Plant of Komatsu. [1] This furnace introduces a carburizing gas, which comprises carbon monoxide, hydrogen and nitrogen, into the furnace and surplus gas having traversed a carburizing process unit is fed to an afterburner for combustion and decontamination, to be released outside the furnace. The lower combustion heat of flames in the afterburner is estimated to be 20 to 30 kw and this waste heat is converted into electricity by the thermoelectric generating system. The thermoelectric generator consists of sixteen thermoelectric generating modules made of a Bi-Te thermoelectric material. Each thermoelectric generating module is 50mm wide and deep and 4.2mm high. Each module is specified to generate an output of 24 W when the hot-side temperature is 280 and the cold-side temperature is 30 C. The sixteen modules are categorized into four groups, each of four modules. The electrical connections of the modules are roughly divided into parallel and serial connections. When robustness and reliability are paramount, a parallel connection is used and when the wiring is simple and the impedance is high, a serial connection. At present (as of October 2011), four modules are connected serially in a four-line configuration. The durability and reliability of the thermoelectric generating modules were verified by a heat cycle, continuous generation tests and various high-temperature exposure tests on a device level. Improvements in durability and reliability are repeated. For example, in heat cycle tests, output degradation is controlled to several percent or lower after 10,000 cycles under constant cycle conditions of 30 C on the low temperature side and between 250 and 50 C on the high-temperature side. A maximum power point tracking (MPPT) system uses a simple control circuit embedded with an 8-bit one-chip microcomputer to generate power under optimum conditions, despite the flame conditions varying from time to time. The output of sixteen thermoelectric generating modules is used to charge four lead storage batteries and supply power to light up LED lamps in the Awazu Plant of Komatsu through an inverter. The modules output 240 W when the temperature of the heat collection plate is 240 C and the cooling water temperature is 20 C. Key Words: Thermoelectric Generation, Bi-Te, Awazu plant, Carburizing furnace, MPPT 2011 VOL. 57 Recovery NO.164 of 26

1. Introduction Based on the achievements gained in Development of High-efficiency Thermoelectric Conversion System 2002-2006 of NEDO (New Energy and Industrial Technology Development Organization) project in September 2009, KELK Ltd., a subsidiary wholly owned by Komatsu, started the volume production and sale of thermoelectric generating modules (hereinafter referred to as thermo-modules ) using a Bi-Te alloy. [1] Under the NEDO project, Komatsu developed a cascade-type module stacked with Bi-Te and silicide modules and targeting 15% conversion efficiency at hot- and cold-side temperatures of 550 and 30 C, respectively. [2], [3] Based on these results, a thermoelectric generating system was installed at a carburizing furnace in the Awazu Plant of Komatsu to study the feasibility of the thermoelectric generating system in recovering plant waste heat, as part of reliability and durability tests and promote social recognition of the system. This paper reports the system features and performance. 2. Power Generation Characteristics of the Thermo-Module Operable temperature range: High-temperature side 280 C maximum, normal operation 250 C or less, low temperature side 150 C maximum Conversion efficiency: 7.2% maximum Material: Bi-Te alloy Voltage V Conversion efficiency Current A Conversion efficiency Output power About 1 W/cm 2 High-temperature side temperature C Fig. 1 Developed Bi-Te thermo-module Fig. 1 is a photo showing an appearance of the Bi-Te thermo-module, the features and specification of which are supplied in the following. [1] [Features] World s highest conversion efficiency. Large output obtainable, even with a small temperature difference (Operating conditions: High-temperature side 280 C, low temperature side 30 C) High output density of about 1 W/cm 2, compact equipment and system Low current and high voltage of 3A and 8V at maximum output, featuring easy handling of electric circuits [Product Specification] Dimensions in mm: 50 x 50 x 4.2 excluding lead wires Weight: 47g Output: 24 W maximum (at hot- and cold-side temperatures of 280 and 30 C respectively) Fig. 2 Power generation characteristic (a), maximum output and conversion efficiency (b) of the thermo-module. In (a), corresponds to (1) (1P): (T h = 280 C, (2) (2P): T h = 250 C, (3) (3P): T h = 200 C, (4) (4P): T h = 150 C. T c = 30 C. Fig. 2 plots the power generation characteristics, maximum outputs and conversion efficiency of the thermo-module. Voltage V and output P corresponding to various hot-side temperatures T h are plotted as functions of current l flowing into the thermo-module. This evaluation of maximum output and conversion efficiency is measured by limiting the cold-side temperature T c to 30 C. The V value at I = 0 is open-circuit voltage V o and 12 and 14V when T h = 250 and 280 C, respectively. Differing significantly from the I-V characteristic of solar cells, V linearly decreases alongside I and the inclination of the straight line at this time becomes the internal resistance R i of the thermo-module. R i has no prominent temperature dependence on T h and is generally constant at about 2Ω. Output P can be obtained from the external load r connected to the thermo-module and calculated by P = V x I. P fetches the maximum output P max in impedance matching when R i = r. As shown by P max - T h plotting in Fig. 2 (b), the 2011 VOL. 57 Recovery NO.164 of 27

maximum outputs are 20 and 24W when T h = 250 and 280 C, respectively. Fig. 2 (b) also plots the conversion efficiency η - T h of the thermo-module. η increases linearly alongside T h and reaches η = 7.2% when T h = 280 C. 3. Thermoelectric [4], [5] Cooling water outlet Outer door Unmanned transfer robot Flame Oil tank Cooling water inlet Thermoelectric generator Inner door Carburizing unit Carburizing gas other factors. However, one of the sixteen modules connected was damaged and the entire generator output was shut down, showing a lack of robustness. This robustness can be improved by installing a bypass diode, but this does not allow utilization of the largest advantage, namely, simple wiring. Conversely, parallel connections have shortcomings, namely, the wiring becoming complex and an inability to handle large currents due to low impedance. However, the maximum power of each module can be tracked (MPPT - Maximum Power Point Tracking). Even if temperature distribution becomes uneven by MPPT, each module can be made independent to implement MPPT to each of the modules and high robustness can be achieved as advantages. In reality, serial and parallel connections will be suitably combined depending on the locations. However, a fail-safe circuit by the bypass diode must be embedded as mentioned above. Terminal block Pressing springs Thermoelectric generator Seal 16 thermo-modules Heat Sink Board Fig. 4 Partial cross section of the thermoelectric generator shown in Fig. 3 (b) Fig. 3 Thermoelectric generating system (a) and example of a thermoelectric generator (b) installed at the Awazu Plant of Komatsu Fig. 3 (a) shows a sketch of the thermoelectric generating system installed at the Awazu Plant of Komatsu. The flame is generated by igniting a pilot burner to decontaminate H 2 and CO in the carburizing gas (RX gas) and is burnt to heat the heat collection plate of the thermoelectric generator. When the flow rate of RX gas is 10 m 3 /h, the combustion heat is estimated at about 20 kw. Fig. 3 (b) shows an example of the thermoelectric generator. The heat collection plate measures 400 x 280 mm and has a fin structure to increase the heat collection area and efficiency. The surfaces of the heat collection plate are blackened. A total of sixteen thermo-modules (in 4 groups, each having four modules) shown in Fig. 1 are placed on the opposite side of the heat collection plate. The method used to connect the thermo-module should be flexible depending on where the system is installed. The advantages of connecting all modules in series are to ensure high impedance can be produced and high voltage obtained, enabling a power conditioner for solar cells to be used without a DC/DC converter, simple wiring and Two typical examples of heat collection plates tested to date are as follows. The first is a simple flat plate and the second has a simple fin structure. (Fig. 3 (b)). Fig. 4 illustrates a partial cross section of the thermoelectric generator shown in Fig. 3 (b). Each thermo-module is sandwiched between the heat collection and water cooled plates by a spring structure, meaning almost constant pressure is applied to the module, even if a temperature difference is generated. The pressure is set to 1 MPa as a criterion, with a cooling water flow rate of 10 to 12 liters/minute and the cold-side temperature maintained at an estimated 40 C or less. The heat collection plate temperature T h that is read from the temperature sensor in Fig. 4 varies within the range 120 to 250 C depending on the carburizing process. The heat collection efficiency is about 20% and a heat quantity of only about 4 kw is introduced from flame combustion heat of 20 kw. A comprehensive study is urgently needed to optimize the fin structure and study the material of the heat collection plate, the layout position of the thermoelectric generator and other matters. 2011 VOL. 57 Recovery NO.164 of 28

Power system switching (Battery monitor) Monitor, surveillance (Overheat alarm) 100VAC Exhaust duct Monitor, surveillance (Abnormal water temperature alarm) Monitor, surveillance (Abnormal water level alarm) Fluorescent lights at Awazu Plant Inverter Complete combustion gas Thermoelectric unit Escape Mechanism Actuator Escape command Sequencer Air Burner Thermometer Pump Flowmeter, thermometer Valve Filter Cooling water IN Battery MPPT charge/ discharge controller Carburizing gas Heat treatment furnace Carburizing gas OUT Monitor for the amount of power generated Fig. 5 Power system of a thermoelectric generating system installed with carburizing equipment of the Awazu Plant of Komatsu Fig. 5 illustrates the power system of the thermoelectric generating system installed with the carburizing equipment of the Awazu Plant of Komatsu. The power generation output is stored in the lead storage battery through the MPPT charge/discharge controller. The power from the battery is converted into 100VAC by a general-purpose inverter to supply power to light up the LED lights inside the plant. The MPPT efficiency is about 85%. The cooling water flow rate, cooling water temperature and heat collection plate temperature are always monitored. The escape mechanism extinguishes the flames of the thermoelectric generating unit after receiving an alarm signal from the meters and thermometers, which ensures safety. Fig. 6 Plotting of the heat collection plate temperature T h and thermoelectric generator output P The thermoelectric generator output P is plotted in Fig. 6 as a function of the heat collection plate temperature T h. When T h = 250 C, a 240 W output is obtained, showing that each module outputs 15 W on average. According to the power generation output characteristic of each module shown in Fig. 2, an output of 20 W is estimated to be obtainable when T h = 250 and T c = 30 C. This difference can be explained by a reduction in the real temperature difference provided to the hot and cold-sides of the thermo-modules due to the heat collection plate, ceramic substrate and inclusions such as grease, by non-uniform heating of the sixteen thermo-modules and losses caused by the resistance of the lead wires that fetch the output. Conclusion A thermoelectric generating system was installed with a carburizing furnace at the Awazu Plant of Komatsu to recover waste heat. The thermoelectric generator has sixteen thermo-modules developed jointly by KELK and the Corporate Research Division and outputs 240 W when the heat collection plate temperature is 250 C. However, of the total waste heat of 20 kw, the quantity traversing the thermoelectric generator is 4 to 5 kw and the heat collection efficiency remains low, at about 20%. A heat collection efficiency of 40% or higher is considered feasible by refining the generator layout and fin structure of the heat collection plate. This means that penetrating heat of 2 kw per furnace can be fetched. A trial 2011 VOL. 57 Recovery NO.164 of 29

calculation shows that 500 W output can be fetched per generator. There are more than ten carburizing furnaces of equivalent size at the Awazu Plant. When all the carburizing furnaces are installed with a thermoelectric generator, power generation output of about 10 kw is obtainable. An operating ratio of about 80% is feasible and total power output about six times that of solar power systems operating at 12% can be obtained. [6] The thermoelectric generating system has been in operation for more than 10,000 hours in aggregate from October 2009 to date (November 2011). No decline in output was found during continuous operation of more than 2,000 hours. In fiscal 2012 ending March 2013, the system will be expanded to a power generation capacity of the 10 kw class, to demonstrate power generation capability, start a new market and expand applications. Introduction of the writers Hiromasa Kaibe Senior Manager Takeshi Kajihara Manager Acknowledgments This R&D project was undertaken based on the achievement gained in a project Development of High-efficiency Thermoelectric Conversion System 2002-2006 subsidized by NEDO. The writers express their appreciation for this subsidy. References: 1. http://www.kelk.co.jp/english/news/090128.html 2. http://www.nedo.go.jp/activities/portal/p02022.html 3. H.T.Kaibe, L.Rauscher, S.Fujimoto, T.Kurosawa, T.Kanda, M.Mukoujima, I.Aoyama, H.Ishimabushi, K.Ishida, S.Sano, Developement of thermoelectric generating cascade modules using silicide and Bi-Te, Proc 23rd International Conference on Thermoelectrics (ICT2004), Adelaid, Australia, June. 2994. 4. H. Kaibe, S.Fujimoto, H.Mizukami, S. Morimoto, Field Test of Thermoelectric at Komatsu Plant, Proc of 2 nd Conference Thermoelectric Goes Automotives, Berlin, Germany, December 2010, p.234. 5. H. Kaibe, S.Fujimoto, T.Kajihara, K.Makino, H.Hachiuma Thermoelectric attached to a Carburizing Furnace at Komatsu Ltd., Awazu Plant, Proc of 9 th European Conference on Thermoelectrics, Thessaloniki, Greece, September 2011, 201E_10_O. 6. For example, http://staff.aist.go.jp/toshi-tosha/geothermal/gate_day/ presentation/meti1-ito.pdf. Shinichi Fujimoto Manager Kazuya Makino Supervisor Hirokuni Hachiuma Department General Manager [A few words from the writers] We believe that the project is fulfilling a pioneering mission as an example of the industrial application of the thermoelectric generating system. Aside from thermoelectric power generation itself, efforts will be made to develop the market by making further progress in the areas of power recovery technology, durability and cost competitiveness through the cooperation of related personnel. 2011 VOL. 57 Recovery NO.164 of 30