HP Notebook Hard Drives & Solid State Drives. Identifying, Preventing, Diagnosing and Recovering from Drive Failures. Care and Maintenance Measures



Similar documents
Installing Microsoft Windows

This user guide describes features that are common to most models. Some features may not be available on your computer.

Intel Rapid Start Technology (FFS) Guide

This user guide describes features that are common to most models. Some features may not be available on your computer.

HP Client Manager 6.1

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

HP Client Manager 6.2

Computer Setup User Guide

Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology

Installing Microsoft Windows on HP Compaq and EliteBook Notebook PCs

This user guide describes features that are common to most models. Some features may not be available on your computer.

WHITE PAPER. HP Guide to System Recovery and Restore

HP VMware ESXi 5.0 and Updates Getting Started Guide

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 16 Fixing Windows Problems

Getting Started. rp5800, rp5700 and rp3000 Models

HP Embedded SATA RAID Controller

RAID 1(+0): breaking mirrors and rebuilding drives

Installing Microsoft Windows 8 on HP ElitePad 900 G1 Tablet

HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers

HP Compaq notebook common image white paper

HP Smart Array Controllers and basic RAID performance factors

SSD Firmware Update Utility Guide

Using HP System Software Manager for the mass deployment of software updates to client PCs

HP Compaq Business Notebook nc6400 software overview

Installing Microsoft Windows on an HP ProBook or EliteBook Notebook PC and creating an image

installing UEFi-based Microsoft Windows Vista SP1 (x64) on HP EliteBook and Compaq Notebook PCs

Configuring ThinkServer RAID 100 on the Lenovo TS130

RAID Technology Overview

HP Thin Client Imaging Tool

HP Embedded SATA RAID Controller

QuickSpecs. Models. HP StorageWorks X510 3TB Data Vault. HP StorageWorks X500 Data Vault. HP StorageWorks X500 Data Vault.

Backup and Recovery User Guide

Configuring ThinkServer RAID 100 on the TS140 and TS440

THE. solution. STORe it. SHARE it.

You have more pressing concerns than how to backup and share your data but you know it needs to be done and you know it would benefit your business.

HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide

Bluetooth Pairing. User Guide

GPT hard Disk Drives. For HP Desktops. Abstract. Why GPT? April Table of Contents:

HP Compaq dc7800p Business PC with Intel vpro Processor Technology and Virtual Appliances

HP Personal Workstations Step-By- Step Instructions for Upgrading Windows Vista or Windows XP Systems to Windows 7

Managing Microsoft Hyper-V Server 2008 R2 with HP Insight Management

HP USB Smartcard CCID Keyboard. User Guide

How To Use The Enhanced Write Filter On Windows Xp Embedded (Dota) With A Powerbook (Dot) And Powerbook 2 (Windows Xp) With An Overlay (Powerbook) With The Write Filter (Wfmgr) On A

QuickSpecs. Models HP 750GB 7200rpm SATA (NCQ/Smart IV) 3Gbp/s Hard Drive

Installing Windows XP Professional x64 on the HP Compaq 8510w and 8710w Mobile Workstation

Getting Started. HP Retail Systems

Windows 7 XP Mode for HP Business PCs

Quick Start to Evaluating. HP t5630w, HP t5730w, HP gt7720

You have more pressing concerns than how to backup and share your data but you know it needs to be done and you know it would benefit your business.

Dual-boot Windows 10 alongside Windows 8

HP 80 GB, 128 GB, and 160 GB Solid State Drives for HP Business Desktop PCs Overview. HP 128 GB Solid State Drive (SSD)

Intel Rapid Storage Technology

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

Using esata on HP Compaq dc7900 Business PCs

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

QuickSpecs. What's New Dual Port SFF 10K and 15K SAS drives Dual Port 3.5" 15K SAS drives. HP SAS Drives (Servers) Overview

Intel Matrix Storage Console

Intel Matrix Storage Manager 8.x

HP Windows 7 Onsite Upgrade Service

Samsung Magician v.4.5 Introduction and Installation Guide

Backup and Recovery User Guide

HP ProLiant Cluster for MSA1000 for Small Business Hardware Cabling Scheme Introduction Software and Hardware Requirements...

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

SSDs tend to be more rugged than hard drives with respect to shock and vibration because SSDs have no moving parts.

Firmware security features in HP Compaq business notebooks

Software Update, Backup, and Recovery

HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide

HP 128 GB Solid State Drive (SSD) *Not available in all regions.

Backup and Recovery User Guide

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits. Overview

Using GIGABYTE Notebook for the First Time

Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs

Using Integrated Lights-Out in a VMware ESX environment

Using HP ProLiant Network Teaming Software with Microsoft Windows Server 2008 Hyper-V or with Microsoft Windows Server 2008 R2 Hyper-V

HP Commercial Notebook BIOS Password Setup

How to register. Who should attend Services, both internal HP and external

Guide to SATA Hard Disks Installation and RAID Configuration

Using GIGABYTE Notebook for the First Time

RAID 1(+0): breaking mirrors and rebuilding drives

HP Online ROM Flash. User Guide

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

RAID 5 rebuild performance in ProLiant

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

QuickSpecs. PCIe Solid State Drives for HP Workstations

HP Insight Diagnostics Online Edition. Featuring Survey Utility and IML Viewer

Using ATI Array Management Software (WebPAM)

QuickSpecs. HP Z Turbo Drive

Guide to SATA Hard Disks Installation and RAID Configuration

HP ilo mobile app for Android

HP External Hard Disk Drive Backup Solution by Seagate User Guide. November 2004 (First Edition) Part Number

HP AppPulse Active. Software Version: 2.2. Real Device Monitoring For AppPulse Active

P4000 SAN/iQ software upgrade user guide

Using GIGABYTE Notebook for the First Time

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later

HP PolyServe Software upgrade guide

HP 80 GB, 128 GB, and 160 GB Solid State Drives for HP Business Desktop PCs Overview. HP 128 GB Solid State Drive (SSD)

Using AORUS Notebook for the First Time

CASPER SECURE DRIVE BACKUP

Transcription:

HP Notebook Hard Drives & Solid State Drives Identifying, Preventing, Diagnosing and Recovering from Drive Failures Care and Maintenance Measures Technical White Paper Table of contents Identifying, Preventing, Diagnosing, and Recovering from Drive Failures... 2 Introduction... 2 Symptoms of Hard Drive (HDD) Performance Issues... 2 Hard Drive / Solid State Drive Troubleshooting Flowchart... 4 Hard Drive & Solid State Drive Diagnostics... 5 Advanced Diagnostics - Unified Extensible Firmware Interface (UEFI)... 5 HP 3D Drive Guard... 5 Firmware & Product Updates... 6 Intel Matrix Storage Technology driver... 6 Installing SATA drivers... 6 Care and Maintenance Measures... 7 Preparing Advanced Format HDDs for Microsoft Windows installations... 7 Hard Drive Mounting Bracket... 7 HP CMI - Client Management Interface... 7 Additional HP Recommendations for Optimizing Performance on Products with Older Operating Systems.. 7 For more information... 8

Identifying, Preventing, Diagnosing, and Recovering from Drive Failures Introduction This white paper explains how companies and users can reduce the risk of hard drive failures. These measures include enhanced hard drive diagnostics, Intel Storage Matrix Technology, HP 3D drive guard, firmware updates, and more. The following sections explain how to identify and possibly prevent hard drive (HDD) and Solid State Drive (SSD) failures. Symptoms of Hard Drive Issues The symptoms of hard drive issues can be traced to connector issues, shock events, software issues, and more. The following sections summarize some of these. Connector issues It is important to check the physical connector that extends from the hard drive to the system board. A hard drive that is not detected by the BIOS or operating system may need adjustment. Note: The following information is not applicable to Solid State Drives. In the event of an issue with an SSD, the HP Diagnostics should be run. Symptoms may include the following: The SSD drive is no longer recognized by the notebook. You receive an error message during Power On Self-Test (POST) that says "Imminent drive failure." Your notebook spontaneously restarts when the Windows OS is running. Shock events With each new generation of hard drives, manufacturers make improvements to the drive s susceptibility to shock events. However, hard drives are fragile, and if they are exposed to shock events beyond their specifications, they can fail. Shock events can cause read/write head misalignment, or contact between the read/write heads and the media, resulting in symptoms such as a clicking noise, the failure to complete servo, and/or an inaccessible boot device message. Typically, these symptoms result from a significant bump or drop, due to the following factors: Non-operational shock (when the notebook is turned off) or Operational shock (when the unit is turned on and the hard drive is reading or writing data) Shock events may cause different error messages to be displayed such as Non-system disk or No boot device. Software issues Some hard drive performance problems appear to mimic hard drive failure, but may actually be caused by software issues. These software issues include (but are not limited to): File corruption File fragmentation Read errors Page 2

File Corruption One of the most difficult software problems to trace is file corruption, because corruption occurs very easily during routine computer handling. For example, powering off the notebook before the OS has completed the shutdown process can create corrupted boot files that ultimately result in blue screens and/or continuous reboots. Issues such as blue screens, application lockups, and other occurrences are caused by write splices. A write splice is an incomplete write to a sector of the HDD. Upon the next read of that sector, the OS encounters incomplete data, and marks this area as a bad sector. The OS remaps a reserved sector in its place. If write splices continue to occur with increasing frequency, errors such as blue screens, application lockups, and other occurrences will result, because the HDD has reached the Self-Monitoring, Analysis, and Reporting Technology (S.M.A.R.T.) attribute threshold. S.M.A.R.T. technology was developed by a number of major hard drive manufacturers to increase reliability of drives. For more information on S.M.A.R.T attribute checking, refer to the Client Management Software section in this white paper. File Fragmentation Hard drive performance is also degraded when file fragmentation is not reduced by regular software maintenance. Over time, the hard drive file structure becomes fragmented due to continuous creating, editing, copying, and deleting of files. New data is written to the hard drive on a first available space basis. Fragmentation occurs when an entire file or application is not stored contiguously on the hard drive. Once fragmentation occurs, the hard drive throughput performance is impacted, because it must seek the data from multiple locations across the hard drive. Read Errors HDDs can experience issues due to read errors. In this situation, a low-level format of the drive can be performed. Refer to your HDD manufacturer for low-level format utilities or download the HP File Sanitizer for HP ProtectTools, located at the following website: http://h20000.www2.hp.com/bizsupport/techsupport/softwaredescription.jsp?lang=en&cc=us&pro dtypeid=321957&prodseriesid=4138624&prodnameid=4138625&swenvoid=4054&swlang=13& mode=2&taskid=135&switem=ob-86982-1 Other software issues may include viruses, application, and operating system (OS) bugs. To address these issues, refer to your software Help for more information. Page 3

Hard Drive / Solid State Drive Troubleshooting Flowchart End User Experiences: Drive Failure Or Symptoms of Drive Failure Recommended Actions for End User to Take Document any error codes related to the drive failure that have occurred during POST or when attempting to access the drive Document the symptoms e.g. slow performance (opening and closing apps), lock-ups, Microsoft Blue Screen error codes, read or write failures Note any noises such as clicking or clunking Record any Failure IDs from running diagnostics If possible, perform a backup of drive or at minimum back up any important data! Does Operating System recognize drive? YES Run F2 Quick/Short Diagnostic Test NO Try reseating drive & check for loose connectors NO Is drive recognized by the Diagnostics? YES Replace drive or contact customer support for replacement YES Does the drive fail the Diagnostic test? NO Extensive/Long Diagnostic Test will run YES Does the drive fail the Diagnostic test? NO Drive does not need to be Replaced (look to OS, Software, or other hardware problems) Verify Intel Matrix Storage and 3D Drive Guard drivers are installed on image and latest firmware for product model installed Page 4

Hard Drive (HDD) & Solid State Drive (SSD) Diagnostics HP Diagnostics In the event you experience hard or solid state drive issues, the first step is to select the f2 function key when booting up the system. This diagnostic routine detects any faults and issues that can cause the drive to fail. Note: The short/basic and long/full versions have been combined into one. When initiated, the diagnostics perform the following steps: Runs the short/basic test. If no errors occur, the long/full test automatically runs. If no errors occur, S.M.A.R.T. attribute checking automatically runs. If a fault is detected in either of the tests, the process halts and a Failure ID or Code is displayed. Note: The diagnostics may be aborted at any time by pressing the Esc key. Note: The f2 Self-Test is available through the commercial notebook system BIOS. Please visit the HP Web site at http://welcome.hp.com/country/us/en/support.html to download the latest BIOS for your product. See the UEFI section below to install the more advanced diagnostics. Advanced Diagnostics Unified Extensible Firmware Interface (UEFI) The HP System Diagnostics UEFI or HP UEFI Support Environment downloads provide more advanced diagnostic tests, which can be installed to a USB key. Go to your product Software & Drivers download page to obtain: http://welcome.hp.com/country/us/en/support.html To launch the UEFI diagnostics, select the f2 function key when booting up the system. Note: The diagnostics may be aborted at any time by pressing the Esc key. Additional information can be found at the following URL: http://h20000.www2.hp.com/bizsupport/techsupport/document.jsp?lang=en&cc=us&objectid=c01443317& jumpid=reg_r1002_usen HP 3D Drive Guard The opportunity for operational shock is greatest when the notebook is being moved. If the notebook is accidentally dropped or is abruptly impacted by another object, the HP 3D Drive Guard driver receives notifications from the integrated accelerometer, and protects the hard drive (HDD) by automatically "parking the heads" to reduce the risk of damage. Download the latest HP 3D Drive Guard driver under the Solutions section from the Download Drivers & Software website for your product and OS: http://www8.hp.com/us/en/support-drivers.html Note: The 3D Drive Guard is not needed for SSD drives, but it does not harm or in any way damage an SSD if installed. Firmware & Product Updates It is important to check for updates for your product. There are new firmware updates for certain OEM drives and/or special product updates. Download and install any newer HDD firmware updates or other HDD related product drivers for your product and OS: http://www8.hp.com/us/en/support-drivers.html Page 5

Intel Matrix Storage Technology driver HP offers the Intel Matrix Storage Manager driver for notebook PC models that are configured with Intel Matrix Storage Manager Technology. The Intel Matrix Storage Technology solution technology provides improved performance and reliability, as well as support for lower power consumption on computer systems equipped with Serial ATA hard disk drives. Updates to the Intel Matrix Storage Manager driver are released to address known issues. The latest device driver versions address multiple known issues that could affect hard disk drive performance and reliability. To download the latest version of the Intel Matrix Storage Technology driver: http://www8.hp.com/us/en/support-drivers.html Installing SATA drivers SATA Native Mode is a storage interface technology that provides up to 150MB/sec transfer rate for disk traffic, and provides link power management with Intel Application Accelerator drivers. Intel Matrix Storage Manager Driver provides support for the SATA Advanced Host Controller (AHCI) Interface. Procedures for adding SATA drivers to RIS (Remote Installation Service) installation points include: Adding SATA drivers to installation CDs, building an image, and switching to SATA AHCI mode Using Sysprep with SATA in AHCI or NATIVE mode Adding SATA drivers using WinPE can be located at the following URL: http://bizsupport2.austin.hp.com/bc/docs/support/supportmanual/c01600726/c01600726.pdf. Page 6

Care and Maintenance Measures Preparing Advanced Format HDDs for Microsoft Windows installations Historically, hard disk drives (HDDs) have used 512-byte sectors; however, this sector size is now limiting HDD capacity. To address this limitation, the industry is moving Advanced Format drives with 4096-byte (4-KB) sectors eight times larger than current drive technology. With 4-KB sectors, less space is wasted on the physical media, making the drive easier to manufacture and able to support higher capacities. First-generation Advanced Format drives retain backwards-compatibility by using external SATA communications based on a 512-byte sector; however, these drives also known as 512e drives operate internally at 4 KB. Thus, any business notebook with a SATA interface can use an Advanced Format drive. Depending on the installed OS, extra steps may be required to optimize performance. If an OS that is not Advanced Format-aware is being used, you may need to take steps to align logical sectors (OS) with physical sectors (disk media). For information about using Advanced Format drives to optimize the performance of your HP Business Notebook, refer to the following URL: http://bizsupport2.austin.hp.com/bc/docs/support/supportmanual/c02691731/c02691731.pdf. Hard Drive Mounting Bracket Be sure the hard drive is secured in the mounting bracket correctly. For more information, refer to the Maintenance and Service guide for your computer. HP CMI Client Management Interface HP has integrated SMART health monitoring into our management console portfolio. This support is included in all editions of HP Client Automation and HP Client Manager 7.0 from Symantec. More information can be found at the following URL: www.hp.com/go/clientautomation Additional HP Recommendations for Optimizing Performance on Products with Older Operating Systems It is important to have the latest BIOS, firmware, and driver enhancements for your computer. Check www.hp.com for the latest releases. Install and maintain a virus protection program to prevent failures due to viruses. Whenever possible, adjust the power management settings (power schemes) in the Control Panel to permit the hard drive to turn off when it is unused for an extended period of time. For example, adjust the power management settings if you work with applications that execute primarily from electronic memory (such as word processors) that do not have to access the hard drive very often. Perform the Defrag operation periodically to optimize the reading and writing of data to the hard drive. During this process, data is moved to contiguous space. As a result, movement of the hard drive reading/writing heads is decreased. Please refer to the following Microsoft Knowledge Base articles for information on how to defragment your hard drive: Page 7

Windows XP http://support.microsoft.com/default.aspx?scid=kb;en-us;314848 Windows XP command line: http://support.microsoft.com/default.aspx?scid=kb;en-us;283080 Windows 2000: http://support.microsoft.com/default.aspx?scid=kb;en-us;227463 Use the Microsoft Recovery Console periodically to run the chkdsk /p /r commands in order to check your hard drive for any errors, bad sectors, and/or recovery of readable information. Please refer to the following Microsoft Knowledge Base articles for information: Windows XP http://support.microsoft.com/default.aspx?scid=kb;en-us;314058&product=winxp Windows 2000: http://support.microsoft.com/default.aspx?scid=kb;en-us;229716 For more information Contact HP Technical Support: http://welcome.hp.com/country/us/en/wwcontact_us.html Share with colleagues Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Trademark acknowledgments, if needed. 468218-002, Created October 2011 Page 8