R-32. The next generation refrigerant for air conditioners and heat pumps



Similar documents
Fujitsu General New Zealand Ltd

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination

The natural ombination

The natural ombination

Air Conditioners Technical Data

EU F-Gas Regulation Guidance Information Sheet 15: Fire Protection System Contractors

Cooling kw Heating kw

EU f-gas regulation EN 517/2014.

DAikin Altherma low temperature heat pump. end user leaflet

EU F-Gas Regulation Guidance Information Sheet 5: Stationary Air-conditioning and Heat Pumps

Hotel solutions. for hotel owners. Heating - air conditioning - hot water - ventilation - refrigeration - control

HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY

EU F-Gas Regulation Guidance Information Sheet 14: Refrigeration, Air-Conditioning and Heat Pump Contractors

Air conditioners Heating & Cooling

The phase out of R22. Phase out of HCFCs

Air Conditioners Technical Data

Guide to good leak testing

Daikin Altherma Hybrid Heat Pump

COMFORT ALL YEAR ROUND HEATING AND COOLING SOLUTIONS FOR YOUR HOME

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume Refrigerant History

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Guidance for Stationary Refrigeration & Air-Conditioning

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

Part A: Fluid properties

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

Industry insight. Refrigerant gases: an industry in transition.

Certification in the safe and efficient use of alternative refrigerants

THE F-GAS REGULATION AND ITS IMPLICATIONS IN FIRE SUPPRESSION APPLICATIONS

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Update on R32 Air-conditioning and Heat Pump Manufacturing and Sales -Progress Since Last OEWG in Bangkok 2012-

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

emura Form. redefined.

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Refrigeration, Air-conditioning and Heat Pump Sector. The Environmental Protection Agency

Guidance for Mobile Air Conditioning (MAC) Sectors. Guidance: F Gas and Ozone Regulations Information Sheet MAC 3: Key Obligations

Air conditioning is AIR CONDITIONING GUIDE

Next-Generation Refrigerants for Energy Efficiency and Climate Protection. 5 th March 2014 Daikin Air-conditioning India Pvt. Ltd.

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

P08 Köldmedier med låg växthuseffekter

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

your comfort. our world. Daikin Aftercare Service For total peace of mind

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Guidance for Stationary Refrigeration & Air- Conditioning

Inverter technology. bulletin

LG Electronics AE Company, Commercial Air Conditioning

CLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR

Ururu Sarara. The best of the best

Guidance for Stationary Refrigeration & Air- Conditioning

RS-44 (R424A) : Q & A

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Elements Elements describe the essential outcomes.

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

Hybrid heat pumps. saving energy and reducing carbon emissions

HCFC phase-out has started.

Air-cooled Chillers with High Speed Centrifugal Compressors

NETWORK SOLUTIONS.

A guide to synthetic greenhouse gas activities in the New Zealand Emissions Trading Scheme

How to choose a heat pump and use it wisely

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

How To Know If Cfc 12 Is Still Needed

Energy consumption. Environmental indicators

It s Your Choice Retrofitting Your Car s A/C System 1EPA. 2 Printed on paper that contains at least 20 percent postconsumer fiber.

Refrigerant Compliance Policy

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

T160 Heating Refrigeration and AC Technician MTCU Code Program Learning Outcomes

Ecological Sustainability

EU F-Gas Regulation Guidance Information Sheet 21: Training and Certification Requirements for Refrigeration, Air-Conditioning and Heat Pumps

elcome to the era of the SEER seasonal efficiency Product range

EU F-Gas Regulation Guidance Information Sheet 17: F-Gas Producers, Importers and Exporters

Guide to updated EU f-gas regulation (517/2014).

Planning for the ban on R22 in building air conditioning

The Globally Harmonized System and OSHA Hazard Communication Revision

Residential & Commercial Sectors Overview CLIMATE

Continuous flow direct water heating for potable hot water

ROTEX gas hybrid heat pump. A strong team.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY

Test Code: 8297 / Version 1

2. Environmental indicators

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

This leaflet provides information on

Guidance on Process Safety Performance Indicators

Glossary of Heating, Ventilation and Air Conditioning Terms

Transcription:

R-32 The next generation refrigerant for air conditioners and heat pumps

Daikin is the first company in the world to launch heat pumps and air conditioners charged with R-32. This refrigerant has several benefits for the environment. It is very energy efficient and allows to use a lower CO 2 equivalent refrigerant charge. This is the result of its lower GWP (Global Warming Potential) and the fact that less refrigerant is needed in comparison to R-410A. For this reason, R-32 is a perfect fit with the targets of the new European F-gas regulation. Installation and service practices for R-32 are similar to those for R-410A. As it is a pure refrigerant, R-32 is also easier to recover and reuse. 2

Why has Daikin introduced R-32 models? A core element of Daikin s corporate philosophy is that the company strives to be a leader in applying environmentally friendly practices, with energy efficiency and refrigerant choice as key factors. Daikin launched the first worldwide air conditioners with R-32 refrigerant at the end of 2012 in Japan, where several million units have since been installed. Subsequently, R-32 models have been providing indoor climate comfort in other countries such as Australia, New Zealand, India, Thailand, Vietnam, the Philippines, Malaysia and Indonesia. In 2013, R-32 models made their debut in Europe, adding new environmental benefits to the unrivalled control they offer users. Examples of products available in Europe with R-32 refrigerant: Ururu Sarara Daikin Emura FTXM What is R-32? R-32 s chemical name is difluoromethane. It is a refrigerant which has been used for many years as a component of the refrigerant blend R-410A (which is 50% R-32 and 50% R-125). Daikin was the first company to recognise that there are several advantages of using pure R-32 instead of using it as part of a blend. Many other industry players have now followed suit. What is GWP? Global Warming Potential (GWP) is a number which expresses the potential impact that a particular refrigerant would have on global warming if it were released into the atmosphere. It is a relative value which compares the impact of 1kg of refrigerant to 1kg of CO 2 over a period of 100 years. Although this impact can be avoided by preventing leaks and ensuring proper end of life recovery, choosing a refrigerant with a lower GWP and minimising the volume of refrigerant will reduce the risk to the environment if a leak were to occur accidentally. What is ODP? Ozone Depletion Potential (ODP) is a number that refers to the harmful impact on the stratospheric ozone layer caused by a chemical substance. It is a relative value which compares the impact of a refrigerant to a similar mass of R-11. Thus, the ODP of R-11 is defined to be 1. Composition GWP (Global Warming Potential) ODP (Ozone Depletion Potential) R-410A R-32 Blend of 50% R-32 + 50% R-125 2087.5 675 0 0 Pure R-32 (no blend) Refrigerants with lower environmental impact R-32, R-410A, R-134a and other refrigerants currently used in the European Union do not deplete the ozone layer. The previous generation refrigerants such as R-22 had a detrimental effect on the stratospheric ozone layer because they contained chlorine. Since 2004, EU regulations have banned any new equipment using ozone-depleting refrigerants such as R-22. Since January 2015, servicing existing equipment with R-22, even with recycled R-22, has also been banned. Phasing out R-22 If your customer is still using R-22 based equipment today, you should recommend replacing it soon and not waiting until a breakdown occurs. Deciding to change to R-32 equipment instead of R-22 would create a double benefit for the environment. It would eliminate the risk of damaging the ozone layer and would be a better solution in terms of the global warming impact. Just replacing the R-22 refrigerant with R-32 in an existing installation is not allowed because oil and pressures are different. However, it may be possible to replace the indoor and outdoor units and keep the refrigerant piping. (More detailed instructions are available in our catalogue on R-22 replacement technologies) 3

Helping consumers to make the right choice How you can advise about the choice of an air conditioner or heat pump with a lower global warming impact The main impact on global warming from air conditioners or heat pumps comes from the electricity they use If the electricity is generated by renewable sources, this impact can be close to zero. However, if it comes from power plants using fossil fuels, the impact is far higher. In any case, even when the electricity source is low emission, it is still important to be energy efficient and not waste energy. European Energy labels (A+++, A++, A+, A, B, C, etc.) allow consumers to compare the energy efficiency of air conditioners and heat pumps. Recommend that your customers choose a model with a top class energy label The other impact on global warming comes from the refrigerant gas circulating within the system Although this impact can be avoided by preventing leaks and ensuring proper end of life recovery, choosing a refrigerant with a lower GWP and minimising the volume of refrigerant will reduce the risk to the environment if a leak were to occur accidentally. Recommend that your customers select a model with a low CO 2 equivalent refrigerant charge The CO 2 equivalent value is indicated on the advertising materials (catalogues, Daikin website). It is the amount of refrigerant in kg multiplied by the GWP value. Top class energy labels Example: Daikin Emura size 3.5 kw Daikin R-32 wall mounted models are ranked with very high energy labels of A+ and beyond. The Ururu Sarara range is top ranked with A+++ energy labels in both cooling and heating mode. RXZ25NV1B / FTXZ25NV1B If your customer chooses a 3.5 kw Daikin Emura air conditioner charged with R-32 refrigerant the energy label classification in cooling mode is A+++ and in heating mode A++. In addition, the CO 2 equivalent refrigerant charge is 78% lower than the same model charged with R-410A. This is because R-32 has a GWP which is 1/3rd the GWP of R-410A, and the refrigerant volume is also 31% lower. A +++ A+++ 100% 100% 100% 69% 78% 2,50 9,54 92 x 3,50 x x 5,90 x x 831 x 32% 22% 54 59 GWP value R-410A R-32 Refrigerant charge (kg) Potential global warming impact (CO 2 equivalent refrigerant charge: kg x GWP) 4

The revised EU F-gas regulation and why R-32 was introduced Refrigerants impact on global warming If released into the atmosphere, refrigerants can have an impact on global warming. In 2006, EU regulators implemented the so-called F-gas regulation to minimise the risk of a certain group of fluorinated greenhouse gases, of which the most important are the HFC gases commonly used as refrigerants. Certification worked A certification system was introduced for installation and service companies. This, in combination with mandatory leak inspections for systems with a charge of 3kg or more, has successfully reduced emissions. (Note: the revised F-gas regulation still requires leak inspections, but the threshold changed to 5 Tonnes CO 2 equivalent or more, which is equivalent to 2.4 kg of R-410A or 7.4 kg of R-32.) EU and industry working together Despite the fact that F-gas emissions currently only represent 2% of total EU greenhouse gas emissions, EU regulators and the industry have recognised that more can be done in view of the EU roadmap towards a low carbon economy. That is why a revised F-gas regulation came into force at the beginning of 2015. This regulation encourages the design of equipment with lower CO 2 equivalent refrigerant values. In other words, equipment with lower refrigerant GWP or a lower refrigerant charge, but ideally a reduction in both (commonly known as the phase down on HFC consumption, expressed in CO 2 equivalents). Thanks to the revised F-gas regulation, the EU s F-gas emissions will be cut by two-thirds by 2030 compared with 2014 levels. GWP is not the only parameter There is no refrigerant which can meet the needs of every kind of application. This means that Daikin had to evaluate its options carefully, taking into account not only reduction of GWP and the amount used, but also aspects such as energy efficiency, safety and affordability. For example, selecting a refrigerant with a lower GWP, but which uses more energy would not be a good choice, as it would be counterproductive for the total product s global warming impact. 10 years ahead of product bans The new F-gas regulation bans the use of refrigerants with a GWP above 750 in single split air conditioners with a refrigerant charge below 3kg from 2025. Daikin already introduces R-32 models 10 years ahead of this requirement, because the sooner the industry changes to lower GWP refrigerants, the earlier the environmental impact of HFC emissions can be reduced. 5

0.011 kg/m 3 1 kg R-32 - Frequently Asked Questions 1. Is R-32 a safe refrigerant? Because R-32 belongs to the category of lower flammable refrigerants (class 2L in ISO 817 standard), it can be used safely in most air conditioner and heat pump applications. Instructions from the manufacturers of R-32 equipment and from the suppliers of R-32 refrigerant cylinders must, of course, be followed, as must European and national safety rules, as is the case for any type of refrigerant. R-32 will not ignite if the concentration level in a room stays below the lower flammability limit (0.306kg/m³). International and European safety legislation and standards such as EN 60335-2-40 and EN 378 define requirements for remaining well below the lower flammable limit in the case of accidental leakage. R-32 is also difficult to ignite. Sparks generated by relays or switches in household appliances as well as common static electricity do not have sufficient energy to ignite R-32. R-32 is a low-toxic refrigerant, it belongs to the same low toxicity classification as R-410A. For example Current Daikin model ranges using R-32 have following requirements to guarantee safe use, which are perfectly possible to meet in practice. Minimum required floor area Typical floor area for these models OK to install R-32? Daikin Emura FTXJ20 -RXJ20 no limits 20 m² Yes FTXJ25-RXJ25 no limits 25 m² Yes FTXJ35 -RXJ35 no limits 35 m² Yes FTXJ50-RXJ50 2,76 m² 50 m² Yes FTXM FTXM20-RXM20 no limits 20 m² Yes FTXM25-RXM25 no limits 25 m² Yes FTXM35-RXM35 no limits 35 m² Yes FTXM42-RXM42 3,44 m² 42 m² Yes FTXM50-RXM50 3,44 m² 50 m² Yes Calculated based on the requirements of the EN 60335-2-40 safety standard, using maximum refrigerant charge values for maximum piping length between indoor and outdoor. Even if all the refrigerant leaked into this room, the lower flammable limit (0.306kg/m 3 ) would not be reached. R-32 Minimum room size chart for wall-mounted units. 20 16 12 2.5 m m 2 - Minimum floor area 8 4 0 0 1 2 3 4 35 m 2 kg - R32 For wall-mounted units only. Under 1,224 kg there are no floor area restrictions. 6

2. Why do standards classify R-32 as a lower flammable refrigerant while the safety data sheet says it is an extremely flammable refrigerant? International Standard ISO 817:2014 divides the flammability of refrigerants into 4 categories: Class 1 - No flame propagation Class 2L - Lower flammability Class 2 Flammable Class 3 - Higher flammability This classification is based on several criteria, such as the lower flammable limit, heat of combustion and burning velocity. R-32 falls into the lower flammability or Class 2L category. This type of classification is used as a reference in other standards which look at the application of equipment, for example the installation of an air conditioner in a certain room size and building type. The flammability classification shown on Material Safety Data Sheets and cylinder labels is determined in accordance with the Globally Harmonized System of Classification and Labelling of Chemicals (GHS). GHS classifies flammable gases in 2 categories: flammable (cat. 1) and extremely flammable (cat. 2). The GHS classification uses a different approach mainly used as a guidance for international transport rules: gases are classified only by the percentage concentration of gas required to create a flammable mixture in air. Other important factors such as how easy the gas is to ignite or how it behaves once ignited are currently not taken into consideration. This is why, on safety data sheets, R-32 is classified as extremely flammable, like propane (R-290) or isobutane (R-600a) although in reality their flammability risk is quite different. In ISO standards, R-32 is classified as a lower flammable refrigerant (Class 2L), like ammonia and HFO refrigerants, whereas R-290 and R-600a belong to the category of higher flammability (Class 3). 3. Is installing and servicing R-32 equipment different from R-410A equipment? The installation and service methods for R-32 are very similar to R-410A. Working pressures for R-32 and R-410A are similar (Design pressure for R-410A: 4.15 MPa, for R-32: 4.29 MPa) For charging requirements, R-32 is easier to handle as it can be charged in both a gas and a liquid state (not possible with R-410A which always needs to be charged in liquid state. Adding R-410A in gas form may cause the refrigerant composition to change, preventing normal operation). The equipment manufacturer s and the refrigerant cylinder provider s safety instructions must, of course, be adhered to. For equipment, these instructions are similar to R-410A (ventilation required, no smoking, etc.). However, there are additional indications for ensuring a minimum required room size for some R-32 models (see table above in question 1). When repairing an indoor unit, a draught needs to be created from indoors to outdoors to provide good ventilation. This can be created by opening all windows and doors in the building, for example, to extract the air inside the room and have it replaced by fresh air. 4. As a technician, do I need new tools to install and service R-32 equipment? It is particularly important to check that manifolds, leak detectors and recovery pumps can be used with R-32. Tools are available which are permitted and suitable for both R-32 and R-410A. If you are in doubt, check with the tool supplier. For recovering R-32 you need an approved R-32 recovery cylinder. Other installation tools such as charging hose, scale, torque wrench, flare tool, pipe bender and the vacuum pump are the same, so you can use R-410A installation tools. 5. Will R-410A no longer be available? R-410A will remain available for servicing equipment which has already been installed. For new equipment, the use of R-410A will be banned in Europe in single split air conditioners with a refrigerant charge below 3kg from 2025, but not in other applications. However, the use of R-32 is expected to grow in other applications as well because of the phase down targets of the EU F-gas regulation. 7

Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 8400 Oostende Belgium www.daikin.eu BE 0412 120 336 RPR Oostende (Responsible Editor) ECPEN15-017A xxx 07/15 The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. The present publication supersedes ECPEN15-017. Printed on non-chlorinated paper.