Gamma Sterilisation Validation according to ISO 11137 - Sterilising dose -



Similar documents
Packaging Validation according to ISO 11607

Validation of biomedical coatings

Sterile Cleanroom Management

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

Sterilization methods and equipment Lab 1-2

Medical Device Packaging and Sterilization: What you need to know to protect your product

ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers A WHITE PAPER

BACTERIAL ENUMERATION

ENVIRONMENTAL MONITORING

SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT

Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI

STERILIZATION WRAP. STERISHEET user guide for the validation of the packaging THE BACTERIAL BARRIER FOR HUMAN PROTECTION

Terminal Sterilization. vs. Aseptic Processing

Cleaning validation of cleanrooms and preparation equipments

One Detection Technology. Three Applications. One Automated Platform.

Direct Biofilm Culturing for Alberta Oil Sands Tailings Pond Water Remediation

Environmental Monitoring of Clean Rooms

EUROTUBO DELTALAB 6. SWABS

Inspection campaign summary report

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

GUIDE TO GOOD MANUFACTURING PRACTICE FOR MEDICINAL PRODUCTS ANNEX 15 *

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Monitoring the autoclaving process in the pharmaceutical industry

FDA and the Compounding Pharmacy

STERILIZATION AND DISINFECTION

Evaluation of Microbial Growth and Survival on Construction materials treated with Anabec NewBuild 30

Quality Assurance (QA) & Quality Control (QC)

Elastomeric Components for Pharmaceutical Applications - Actual Quality Trends - Claudia Petersen. -Senior Manager Biotechnology-

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

The Prophotonix (UK) Ltd Quality manual

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

CONTROLLING MICROBIAL GROWTH IN WINE

The use of risk assessment tools for microbiological assessment of cleanroom environments. by Tim Sandle

Fast, easy and effective transfection reagent for mammalian cells

The sterilisation of spices, herbs and vegetable seasonings: Understanding the options

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

THE MICROBIAL ID BREAKTHROUGH: How DNA Sequencing Services Help Prevent Catastrophic Cleanroom Shutdowns

Basic Requirements For Aseptic Manufacturing Of Sterile Medicinal Products A Comparison Between Europe And USA

Detergents in CSSD. Wim Renders

centre for radiation protection

LAB 4. Cultivation of Bacteria INTRODUCTION

Lab Exercise 3: Media, incubation, and aseptic technique

CLASSIFICATION OF CLEANROOMS

Annex 4 Supplementary guidelines on good manufacturing practices: validation

ASEAN GUIDELINE ON SUBMISSION OF MANUFACTURING PROCESS VALIDATION DATA FOR DRUG REGISTRATION

Environmental Monitoring

SUPPLEMENTARY GUIDELINES ON GOOD MANUFACTURING PRACTICES (GMP): VALIDATION

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

VALIDATION OF ASEPTIC PROCESSES

Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III

11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07

CYROLITE. Sterilization Methods & Considerations. Technical information

Hazardous Substances and New Organisms Act 1996

Effect of Sterilization Techniques on Polymers

PQS performance specification

HAZARD ANALYSIS CRITICAL CONTROL POINT PLAN SUMMARY SETHNESS PRODUCTS COMPANY LIQUID CARAMEL COLOR

Marine Microbiological Analysis of Ballast Water Samples

Effect of irradiation on chemical changes and contaminated microorganisms in turmeric and creat powder

Guideline on Process Validation

Contaminant. Publication Order Number. EPA Publication Number. Method. Date. Source of Method. Total Coliforms

The Perfect Partnership for GMP Cleaning Services. Total Cleaning Solutions from Micronclean & Isocleanse

INDEPENDANT CONSULTING FOR QUALITY AND REGULATORY AFFAIRS EXPERTS FOR MEDICAL DEVICES

Cleaning Validation in Active pharmaceutical Ingredient manufacturing plants

Revision Date Author Description of change Jun13 Mark Benton Removed Admin. Manager from approval

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

PEOPLE > SCIENCE > SOLUTIONS

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

WHITE PAPER April 18, 2016

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

White paper: FDA Guidance for Industry Update Process Validation

Draft guidance for registered pharmacies preparing unlicensed medicines

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

Fundamental Autoclave Techniques

Qualification of an Environmental Monitoring Program

or

BIOFIL Terminal Filters

ECORISK. Consulenze Ambientali. of Francesco Fratepietro, MChem MSc

UV, An Effective Approved Method of Disinfection

Recent Updates on European Requirements and what QPs are expected to do

Background on Biodegradable Additives

Selection of Disinfectants for Use in the Pharmaceutical Industry. Tim Sandle Head of Microbiology Bio Products Laboratory

Practical Series Seminars and Workshops INTENSIVE TRAINING IN ENVIRONMENTAL MONITORING, DISINFECTANT QUALIFICATION AND CLEANROOM CONTAMINATION CONTROL

Cleanroom. For. Sterile Manufacturing Facilities

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples

Sterilization and Quality Assurance Procedures

WHY IS THIS IMPORTANT?

National Food Safety standard of the People s Republic of China

Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe

I. NACHEVA, D. MITEVA, Y. TODOROV, K. LOGINOVSKA and Tsv. TSVETKOV Institute of Cryobiology and Food Technologies, BG Sofia, Bulgaria

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

Guideline on stability testing for applications for variations to a marketing authorisation

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Guidance for Industry

Transcription:

Synergy makes sence Gamma Sterilisation Validation according to ISO 11137 - Sterilising dose - MG-FSI72-105 Last revision: March 2011 5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4 72 81 22 62 - Fax : 33 (0)4 72 81 22 72

MEDICAL LAB Established in 1989, MedicalGroup presently has five subsidiary companies specialising in the biomedical field: MedicalCoating, MedicalPackaging, MedicalBiomat, MedicalManufacturing and MedicalLab. All of these organisations are EN ISO 13485 certified. Medical Lab offers a comprehensive Performance Qualification service for medical devices: coating, cleaning, packaging and sterilisation validations. The purpose of these qualifications is to assure clients that their medical devices comply with European (EC) and US (FDA) regulations. Medical Lab performs validations and routine tests. THE VARIOUS TYPES OF STERILISATION Two industrial sterilisation technologies are mainly used for sterilization of single use medical devices: - Ionising radiation (BETA and GAMMA rays) - Ethylene oxide Sterilisation by ionising radiation (ISO 11137) Ionising radiation works by energy transfer (the absorption of energy by the target material). Ionisation occurs at room temperature. Treatment depth varies with the type of radiation. Ionising radiation causes breaks in the chromosomal DNA of micro organisms (at the cellular level), which results in their death. Sensitivity to radiation varies considerably from one micro organism to another. This basically depends on the type of germ (the species or strain). Radiosensitivity is numerically evaluated using the D10 value. This corresponds to the radiation dose required to reduce the initial bacterial population to 1/10 th. Most bacterial species have D10 values below 10 kgy. The more resistant bacteria (spore-forming bacteria) can have D10 values as high as 30 kgy. The two type of ionising radiations used for sterilisation of medical devices are: BETA radiation: an accelerated electron beam scans the products as they pass under the beam. GAMMA radiation: γ photons (electromagnetic radiation) are emitted by a radioactive source around which the products pass. The choice between beta and gamma radiation is based on: - the density of the boxes or items - their size / shape - their quantity - the compatibility of the material with beta or gamma radiation Ethylene oxide (ETO) sterilisation (ISO 11135) Due to its powerful permeating ability, ethylene oxide is able to reach into the major constituents of living matter. The efficacy of the treatment is influenced by several parameters: the relative humidity of the gas and the temperature, the type of device and the gas concentration used. The contact period ranges from one to six hours, depending on the concentration of spores and germs, as well as the composition of the exposed items. Ethylene oxide sterilisation is effective against all known micro organisms, except prions.

Compatibility of materials with sterilisation techniques METALS: Metals are generally stable under ionising radiation as under ETO. CERAMICS: Ceramics are usually as stable under ionising radiation, but ionising radiation can induce changes in colour. Influence of ETO on bioactive ceramics or oxide ceramics has to be validated. POLYMERS: Ionising radiation: ionising radiation degrades the properties of most polymers. The type of polymer, the dose received and the dose rate are the main factors influencing the type of degradation observed. Ethylene oxide: Minor degradation of PS and its derivative, SAN. Attention should be paid to temperature with regard to polyolefins (PE and PP). The temperature can be adapted. Attention should be paid to humidity with regard to hydrophilic coatings. STANDARDS AND REGULATIONS The standards applied by MEDICAL LAB for gamma sterilisation validation are as follows: ISO 11137-1: 2006 - Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices ISO 11137-2: 2006 - Sterilization of health care products Radiation Part 2: Establishing the sterilization dose ISO 11737-1: 2006 Sterilization of medical devices Microbiological methods Part 1: Determination of a population of micro organisms on products ISO 11737-2: 2009 - Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process

IQ, OQ and PQ VALIDATION In order to guarantee controlled sterilisation, the sterilisation processes shall be IQ, OQ and PQ validated. Installation Qualification (IQ) Tests and checks are performed on the sterilisation equipment to verify that their characteristics meet previously established specifications. Installation qualification (IQ) falls under the responsibility of the sterilisation operator. Operational Qualification (OQ) After setting the standard adjustment parameters for obtaining a sample result meeting the specifications, the OQ enables validation of these standard parameters, even when the process is carried out under imperfect conditions (adjustment validations and critical cases). Operational qualification (OQ) falls under the responsibility of the sterilisation operator. Dose mapping shall be performed based on the distribution and variability of the dose. Performance Qualification (PQ) This serves to demonstrate that the gamma sterilisation system yields a reproducible, correct result on the product. Product PQ: carried out under the supervision of the product manufacturer. This determines compliance of the sterilization process on the product. 1) Dose Mapping: The first step of the validation is to verify that every product in the sterilization container receives a dose complying with the specifications (for example 25-40 kgy). As the dose received by the products can depend of the density of the products and their position in the sterilization container, before performing the dose mapping validation, the product loaded patter shall be established. With this product loaded pattern, dosimeters will be placed to measure the dose received by the products at different points of the sterilization container. 2) Validation of the sterilising dose: This part of the product PQ makes it possible to validate the minimum irradiation dose required to sterilise the product (i.e. to guarantee a sterility assurance level (SAL) of 10-6 ). 3) Validation of the maximum dose: This part of the validation procedure verifies by means of various kinds of tests that product characteristics are not degraded by irradiation, even at the maximum dose.

VALIDATION OF THE STERILISING DOSE ACCORDING TO ISO 11137 Establishment of the sterilising dose according to ISO 11137 can be determined by one of the following methods (microbiological methods shall be validated before the analyses are performed). The most widely used method is VD max method. Method 1: Determining the dose using microbial load information 1- Select the sterility assurance level (SAL) and select 10 product samples from 3 independent production batches (or 30 samples) The samples must be representative of routinely sterilised products. 2- Determine the average microbial load of the 3 batches of 10 items (method based on ISO 11737-1) 3- Obtain the verification dose (referring to table 5 of ISO11137-2) 4- Conduct verification dose experiments on 100 irradiated pieces (method based on ISO 11737-2) 5- Interpret the results 6- Establish the sterilisation dose based on the results (maximum of 2 positives out of 100 pieces) 130 products are therefore required for this method. The advantage of this method is that it enables any sterilising dose to be validated. Method 2A: Determining the dose using information about the proportion of positives from the incremental dosage in order to determine an extrapolation factor 1- Select the sterility assurance level (SAL) and obtain samples of the product (at least 280 samples for 2 independent production batches) The product samples must be representative of the products routinely sterilised. 2- Conduct the incremental dose experiments; irradiate 20 pieces at incremental doses of 2 kgy beginning with the 2 kgy dose and using at least 9 values. This is to be done for each of the 3 batches involved. Perform a sterility test on each of the products. 3- Conduct verification dose experiments; irradiate 100 pieces at the verification dose and perform a sterility test on each of the products 4- Examine the results 5- Establish the sterilising dose based on the results This method is seldom used owing to the large number of products and tests required to validate a sterilising dose. Method 2B: Determining the dose using information about the proportion of positives from the incremental dosage in order to determine an extrapolation factor Applicable if: the entire product is tested (SIP = 1), after irradiation at any incremental dose, the number of positive sterility tests observed does not exceed 14 FNP (first non-positive) shall not exceed 5.5 kgy 1- Select the sterility assurance level (SAL) and obtain samples of the product (at least 260 samples for 3 independent production batches)

The product samples must be representative of the products routinely sterilised. 2- Conduct the incremental dose experiments; irradiate 20 pieces at incremental doses of 1 kgy beginning with the 1 kgy dose and using at least 8 values. This is to be done for each of the 3 batches concerned. Perform a sterility test on each of the products 3- Conduct verification dose experiments; irradiate 100 pieces at the verification dose and perform a sterility test on each of the products 4- Examine the results 5- Establish the sterilising dose based on the results This method is seldom used owing to the large number of products and tests required to validate a sterilising dose. VD max Method: Justification for a sterilising dose of 25 kgy or 15 kgy Bellow is an example of the procedure for the VD max 25 method on multiple production batches 1- Obtain product samples The product samples must be representative of routinely sterilised products. 2- Determine the average microbial load of 3 batches of 10 pieces 3- According to the table of ISO11137-2, determine the verification dose 4- Conduct verification dose experiments; irradiate 10 products at the verification dose and perform a sterility test on each of the products 5- Interpret the results: Accept the 25 kgy sterilisation dose if 0 or 1 of the 10 pieces is positive. Conduct verification dose confirmation experiments if 2 are positive. Do not accept the verification if there are more than 2 positives 40 products are required for this method. This method is only viable for validating sterilising doses of 15 or 25 kgy. ROUTINE MONITORING AND TESTING: Sterilising dose audit Continuous efficacy of an established sterilising dose shall be demonstrated by: - Periodic Microbial load tests - Periodic dose audits In the case of the VD max25 method, the procedure for dose audits is: 1- Obtain product samples The product samples must be representative of routinely sterilised products. 2- Determine the average microbial load of 1 batch of 10 pieces 3- Conduct the verification dose experiments; irradiate 10 pieces at the verification dose and perform a sterility test on each of the products 4- Interpret the results: Accept the 25 kgy sterilisation dose if there is 0 or 1 positive out of 10 pieces. Perform an audit on the verification dose to confirm if there are 2 positives. Do not accept the verification if there are more than 2 positives The frequency with which sterilising doses are audited must be justified and documented. According to ISO 11137, the interval between dose audits is 3 months. This frequency can be increased to an interval of 12 months but only with the following justification: there shall be a minimum of 4 consecutive satisfactory dose audits, microbial load determinations shall be made every 3 months, and the medical device manufactured according to ISO 13485 standards.

THE VARIOUS TYPES OF TESTS FOR GAMMA STERILISATION VALIDATION There are two microbiological tests performed for the validation of the sterilizing dose: Microbial load determination (i.e. Bioburden) Sterility testing 1. MICROBIAL LOAD DETERMINATION (BIOBURDEN) Reference standard: ISO 11737-1: 2006 - Sterilization of medical devices Microbiological methods Part 1: Determination of a population of micro organisms on products The aim of this test is to determine the number of viable bacteria on the product (before sterilization). Description of the testing method: Sterile container Packaged sample Immersion of sample in the eluent Extraction of bacteria Condition 1 membranes Condition 2 (anaerobic) Condition 3 Enumeration (CFU) Incubation (5 or 7 days) Transfer to culture medium Membrane filtration The sample to be tested is immersed in a sterile eluent, which is next divided up and then filtered through membranes placed over selected nutrient mediums and set to incubate at the appropriate temperature. When incubation is complete, the appearing colonies are counted and the number of micro organisms present on the surface or inside the tested product is calculated. An identification exercise can also be carried out on one or more of the colonies present in order to determine the type of contamination present and thus possibly its origin and its resistance to sterilisation and/or decontamination treatment.

ISO 11737 standard insists on the validation of this technique. Three validation steps are necessary for the validity of routine results to be established. - First of all, the elimination of micro organisms is intended to establish the efficacy of the technique for eliminating germs from the sample in the eluent; the result is a calculation of the correction factor. - Next, the validation of the culture conditions is the basis for selecting the medium(s) used, as well as the temperatures and incubation times which enable the germs obtained from the sample to form colonies. - Lastly, the investigation of the inhibitory effect is to make sure that the type of sample (material, coating, surface residues, etc.) and the physical forces applied during the test do not produce any artefact which could interfere with the microbial load determination. It is very important to note that an unvalidated test does not comply with standards and has no value. 2. STERILITY TEST Reference standard: ISO 11737-2: 2009 - Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process The aim of this test is to detect the presence of viable bacteria on the product (after sterilization). Description of the testing method: Sterile container Packaged sterile sample Immersion of sample in the culture media Incubation (14 days) Assessment of proliferation

The direct inoculation technique is based upon total immersion of the sample in a culture medium. Generally, one or two mediums are tested: trypticase soy broth (TSB) to detect the presence of aerobic bacteria, fungi and/or yeast, and TBR (Thioglycollate broth with resazurin) to investigate the presence of anaerobic and aerobic bacteria. The interpretation is done by turbidimetric analysis: a cloudy medium indicates the proliferation of bacteria. Conversely, a clear medium indicates the absence of growth. Validation is recommended by the standards in order to guarantee the reliability of the results. It is essential to ensure the sterility and the fertility of the culture medium, as well as the absence of an inhibitory effect on the product to be tested, i.e. the ability of micro organisms to form colonies in the presence of the sample.

? DESIGN: QUESTIONS TO ASK What are the normative guidelines for the countries where my products are sold? What is the list of required tests for my sterilisation qualification dossier? Does my sterilisation service supplier have a process performance qualification, an IQ and an OQ? What are my product families (refer to the definition of ISO 11137)? Which product should I choose to represent the product family during sterilisation validation testing and routine testing? Which method should I choose for validation of the sterilising dose? Is the sterilisation method compatible with the medical device? What are the dimensions of the packaged products? What is the density of the packaged products and accepted tolerances? Is the packaging material compatible with the sterilization technique? Is the product s initial microbial contamination known? Is the type of micro organisms present known? If so, how radiosensitive are the germs? Can the quantity and type of micro organisms present on my medical devices vary over time?

REASONS FOR CHOOSING MEDICAL LAB Acknowledged expertise in medical device testing, and in French, European, Chinese and US standards and regulations A full service partner offering training, consultancy and testing services An efficient ISO 13485:2003 quality control system ISO 17025 certified for Bioburden and sterility tests A multilingual sales team (English, German, Italian, Spanish, Arabic, Chinese ) Our experts can assist you with your regulatory processes, and help you determine validation protocols Our collaborative interaction with MEDICAL GROUP subsidiaries helps you limit your suppliers, save time in having your batches released and reduce your transport costs Speedy communication of results (by e-mail or on the website)

CONTACTS Aurélien BIGNON MedicalLab General Manager a.bignon@medicalgroup.fr Stéphane PLET Manager of physico-chemical department s.plet@medicalgroup.fr Alice MARTINHO Manager of microbiological and packaging test department a.martinho@medicalgroup.fr Régine GRIES Quality Control Director r.gries@medicalgroup.fr OUR SALES TEAM Alain BRUNEL Sales Manager a.brunel@medicalgroup.fr Rachid ZEROUALI Export Sales Manager r.zerouali@mediclgroup.fr Richard PUZENAT Sales Manager (France) r.puzenat@medicalgroup.fr

MedicalLab MedicalLab World Wide

5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4 72 81 22 62 - Fax : 33 (0)4 72 81 22 72