Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Similar documents
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Element D Services Heating, Ventilating, and Air Conditioning

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Technical specifications. Containerized data centre NTR CDC 40f+

Zone B: comprises of NOC room, reception area, Help Desk area, Call Centre, Testing/Monitoring room. This zone requires approximately 1500 sq. feet.

JAWAHARLAL NEHRU UNIVERSITY

Automation's Modular Containerized Datacenter Solutions

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Secondary Unit Substations

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Centre Testing and Commissioning

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

RiMatrix S Make easy.

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

SECTION DETECTION AND ALARM

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

The Pros and Cons of Modular Systems

IPSIP M series-m Modular Data Center

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Power Commander Power Distribution Units from Wiremold/Legrand offer

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

Requirements for Electrical Installations

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Managing Data Centre Heat Issues

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Technical requirements

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

8146/5 Series Breaker Panelboards

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Application Briefs: Remote Office Environment

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

Data Center Infrastructure & Managed Services Outline

Scalable. Affordable. Flexible. Fast.

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Commercial Gas Furnace Upflow

CANNON T4 MODULAR DATA CENTRE HALLS

Electronic Control Devices The European Product Catalogue 2007

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

SERVER ROOM CABINET INSTALLATION CONCEPTS

BROWACOM PRODUCTS. Our web-pages can be found from:

Model #: SMART2200CRMXL

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

APC APPLICATION NOTE #92

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Top Commercial / Residential Electrical Requirements *

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

MCR1900 Media Converter 19-Slot Chassis

Engineers Edge, LLC PDH & Professional Training

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Magnum Mobile Generator MMG55 Specifications

THE WORLD S MOST EFFICIENT DATA CENTER

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Best Practices for Wire-free Environmental Monitoring in the Data Center

The New Data Center Cooling Paradigm The Tiered Approach

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

GenStore Archive Cabinet

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Cabinets 101: Configuring A Network Or Server Cabinet

Portable Energy Efficient Data Centre Solution

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

How to Meet 24 by Forever Cooling Demands of your Data Center

CoolTeg Plus Chilled Water (CW) version: AC-TCW

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Cooling Capacity CFM in. w.c. (125 Pa)

SMART SHELTER CONTAINER

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Eaton 93PM UPS Where aesthetics meet intelligence.

Modular Datacenter based in a 20' container

USER S MANUAL HSC-24A

Data Center Solutions - The Containerized Evolution

Zenith Series MDU & RDU. Critical Power Distribution Units

How To Make A Fronius Cl Power Inverter

Data Center Presentation

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Transcription:

TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while enabling adaptive scalability in single or multi-module configurations as compute demands change. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

BASELAYER EDGE D400E Data Module (60Hz) HIGHLIGHTS Delivers up to 400kW of Critical IT power and Cooling for up to twenty (20) 52U racks. Engineered to meet NEMA 4 compliance standards for deployment in all global environments. Ships configuration tested from the factory with an enhanced integrated Module Control Unit (MCU) providing access to key module sensors and controls via a web based server. Power and cooling redundancy thresholds are configurable through BASELAYER OS. SPECIFICATIONS 11 8 /3.55m 12 8 /3.96m 602.783.1112 baselayer.com Exterior Dimensions Length Width Height 42 8 (13.00m) 20 6 (6.24m) 13 0 (3.96m) Interior Tech Space Dimensions Length Width Height 41 8 (12.70m) 11 0 (3.36m) 8 4 (2.54m) Estimated Module Shipping Weight 57,000 lbs (25,855 kg) Includes both IT and Cooling block (IT gear not included) Number of Standard Cabinets 20 x 24" (609.6mm) Cabinets 16 x 30" (609.6mm) Cabinets Rack U Up to 52U Voltage Frequency 480V, 3 Phase, 4 Wire 60Hz Power Distribution (IT) Up to 800A per Busway (2X) (each Busway A and each Busway B) Cooling Mechanics Chilled Water Heat Removal 8 Total: Fan/Coil combinations Leak Detection Spot Leak Detection (9 total) 2015 BASELAYER TECHNOLOGY, LLC

BASELAYER EDGE D400E Data Module (60Hz) SYSTEM PERFORMANCE System PUE Range As low as 1.15 (Dependent upon Environmental and Operational Conditions) Maximum Module Capacity Maximum Available kw @ N 400kW MAX CAPACITY @ N+1 400 kw MAX CAPACITY @ 2N 200kW MAX CAPACITY Maximum Module Density/Rack Access Control @ N 20.0kW/rack (20 x 24" racks) 25.0kW/rack (16 x 30" racks) @ N+1 20.0kW/rack (20 x 24" racks) 25.0kW/rack (16 x 30" racks) @ 2N 10.0kW/rack (20 x 24" racks) 12.5kW/rack (16 x 30" racks) Control Compartmentalized Architecture Role Based Access Control Layers of Physical & Logical Protection Separate Tech, & Support Space Access Fire System Dedicated Fire System Dedicated 4-wire loop to signaling devices and initiating devices, with all batteries, amplifiers, transponders provided for a fully addressable fire alarm system. Pre-Discharge Alarm & Strobe Light Fire Rating 1 Hour Baselayer OS Data Center Operating System Intelligent Control Available (UI) User Interfaces Environmental Operating Conditions Customizable: Role Based Visibility, Warnings, Alarms, Thresholds & Control Set Points Visualizer Desktop and Mobile, Business Reporting, API Provides Real-time Visibility, Control, Optimization, and Automation Operating Temperatures -30 F (-34 C) to 140 F (60 C) Operating Humidity 0 to 100% (RH) Outdoor Compliance NEMA 4 Listings, Regulatory Compliance, Certifications Underwriters Laboratories (UL) UL 2755 National Fire Protection Agency (NFPA) Compliant Support Maintainability Concurrently Maintainable Warranty Standard 1 year limited warranty; upgradable to 3 year limited warranty 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

BASELAYER EDGE D400E Data Module (60Hz) SPECIFICATIONS Exterior Dimensions L 42'8" (13.00m) (No Vestibule) W 20'6" (6.24m) H 13'0" (3.96m) Shipping Weight of Module Max. 30,000lbs for IT Block (Without IT Gear) Door Specifications 1 Door per aisle at end of the module, Zero-threshold for rolling 3,500lbs cabinets in and out (IT Block) Panic door open hardware, door stops and exterior rated closer Exterior Wall White Aluminum Exterior Skin Interior Wall White Painted Galvelum Interior Skin Insulation Mineral Fiber 4" R-3.6 Thermal Insulation Roof 600 lbs./ft2 (25.28 kg/m) Max Roof Loading Flooring Nonslip floor, resistance of no less than 150kOhm when measured between any 2 points 3ft apart Maintenance Access per code requirements to all equipment requiring maintenance. Interior Dimensions L 41 8' (12.7m) (IT Block) W 11' 0 (3.35 m) H 8 4" (2.54 m) Coatings High performance coatings with min. 15 year lifetime. Exterior ferrous metals shall be protected from corrosion through galvanizing, plating or high performance coatings. Dissimilar metals should be avoided and steps taken to avoid corrosion. IT Power: Bus Bar A 288KVA, 800A, 208V-3ϕ, 120V-1ϕ IT Power: Bus Bar B 288KVA, 800A, 208V-3ϕ, 120V-1ϕ IT Rack Envelope 480-in long x 48-in deep x 112-in tall Max. rack qty. 20 X 24in racks or, 16 X 30in racks Rack U Up to 52U Max. rack weight 3500lbs. Rack mobility Rack roll in/roll out at full weight Cold aisle clearance 57-in (door 45-in wide x 94-in tall) Hot aisle clearance 36-in (door 22-in wide x 94-in tall) Above rack clearance 14" to 20" of clearance based on rack heights of 52U to 48U Voltage 480V, 3ϕ 4W Frequency 60 Hz IT Distribution Up to 800A per Busway (each Busway A and each Busway B) IT Metering Metering capability build into buss plugs Lugs Provide three-hole irreversible NEMA compression lugs for all connections Breakers All breakers over 125A-rated frame LSI type with electronic trip functions. All breakers 100% rated. Panel boards Panel boards: NEMA PB 1, UL 50, 61, with Overcurrent protective devices, enclosure suitable for use, copper bus, compression type main and neutral lugs, IEEE C62.1 surge arresters. Maximum Breaker Size Up to 100A for distribution Neutrals 200% output neutral currents Grounding System Ground bar internal to module for frame and equipment grounding All equipment and metallic surfaces bonded to ground Single point grounding system designed to meet IEEE Emerald Standard 1100-1999 UL467, copper conductors, NEC wire and cable conductors. < 5 Ohm impedance. Convenience Outlets 2 x Outlets (GFCI) in the cooling block 120V (Max Current 20A) Lighting Internal According to TIA-942A, 500lux at 30" from floor Occupancy sensors installed within all modular infrastructure. Dual technology: (Infra-red, ultrasonic); High Efficiency LED Light Fixtures Lighting External Pre-wire accommodation for external lights on each end of the module for min 5fc at ground Cooling fluid Water Supply/Return Connections 2-ct 6-inch flanged pipe coupling Max Heat Removal Capacity 8 fan coils @N yields 640KW Leak Detection Spot Leak Detection in the Cooling Block PERFORMANCE System PUE Range As low as 1.15 (Dependent upon Environmental and Operational Conditions) Maximum Module Capacity Maximum Available kw @N 400kW MAX CAPACITY @N+1 400kW MAX CAPACITY @2N 200kW MAX CAPACITY Maximum Module Density/Rack Access Control @ N 20.0kW/rack (20 x 24" racks) 25.0kW/rack (16 x 30" racks) @ N+1 20.0kW/rack (20 x 24" racks) 25.0kW/rack (16 x 30" racks) @ 2N 10.0kW/rack (20 x 24" racks) 12.5kW/rack (16 x 30" racks) Control Compartmentalized Architecture Role Based Access Control Layers of Physical & Logical Protection Separate Tech & Support Space Access Cameras Pre-wired (IP based), customer selectable option. One per aisle. Above each entry point on module outside Identification Card Reader or Biometric Check Points (Fingerprint or Retina Technologies) Request to Exit 4 x Request To Exit Sensors Built into Door Handles (Inside Tech Space) Door Locks Magnetic Locks Fire System Dedicated Fire System Dedicated 4-wire loop to signaling devices and initiating devices, with all batteries, amplifiers, transponders provided for a fully addressable fire alarm system Pre-Discharge Alarm & Strobe Light Smoke Detection Spot detection Suppression agent 1 x 560lb (254kg) Novec 1230 Fire Protection Fluid Storage Tank Fire Rating NFPA72 BASELAYER OS Data Center Operating System Intelligent Control Available (UI) User Interfaces Environmental Operating Conditions Customizable: Role Based Visibility, Warnings, Alarms, Thresholds & Control Set Points Visualizer Desktop and Mobile, Business Reporting, API Provides Real-time Visibility, Control, Optimization, and Automation Operating Temperatures -30 F (-34 C) to 140 F (60 C) Operating Humidity 0 to 100% (RH) Operating Altitude Up to 10,000 ft (3,048 m) Outdoor Compliance NEMA 4 Listings, Regulatory Compliance, Certifications Underwriters Laboratories UL 2755 National Fire Protection Agency (NFPL) Compliant Support Maintainability Concurrently Maintainable Warranty Standard 1 year limited warranty; upgradable to 3 year limited warranty 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC