SYNTHETICNON-WOVENFABRICS VILEDONAIRFILTER



Similar documents
A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Camfil Farr Technical Services Bulletin

COARSE DUST FINE DUST GAS ADSORPTION EPA HEPA ULPA Product Catalogue Filters for HVAC Systems and Cleanrooms

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Environmental Monitoring

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

How to Choose An Air Filter For Your Boat

Kompressoren. Adsorption Dryer AD

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

How To Remove A Large Particle From A Large Tank

Certification system of air filter quality (CAF mark)

Safety Data Sheet Customwood MDF

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

ThermoSorb Desiccant Dryers

furnishings flammability characteristics

HVAC - PANEL AIR FILTERS

HVAC - PANEL AIR FILTERS

NON-WOVEN COMPOSITE OFFICE PANEL

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Material Safety Data Sheet

Filter Testing. An overview on Topas equipment

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

HIGH PERFORMANCE FILTERS AND ELEMENTS

Application Guide Selection of Type Enclosures

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Donaldson Filter Cartridges

the runnerless types of molds are explained post molding operations are described the basic methods of applied decoration methods are examined

SAFETY DATA SHEET 安 全 数 据 单

Selective Laser Sintering of Duraform TM Polyamide with Small-Scale Features

CONTENTS. 1 cooling technology white paper

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Material Safety Data Sheet

Article published: May 2004,

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.

Double Base Powders - Enduron SAFETY DATA SHEET March The following smokeless powders are distributed by IMR Legendary Powders

Lab PPE Guide Examples of Personal Protective Equipment

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

BROKEN VANE REPLACEMENT VT SERIES

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Laminar Flow Cabinets

MATERIAL SAFETY DATA SHEET

PANDA SPRAY BOOTH FILTER INFORMATION

CYCOM 2040 EPOXY PREPREG

CLEANING ASBESTOS ROOFING? REMOVE THE THREAT OF DANGEROUS ASBESTOS FIBRES ENCAPSULATE WITH

TECHNICAL BULLETIN

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Printed Circuit Board Fabrication N I A G A R A C O L L E G E T E C H N O L O G Y D I V I S I O N

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

Dust Filtration Catalogue

Environmental Monitoring of Clean Rooms

Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process

Safety Data Sheet for Whole Grain

Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms. Product Overview

PR11 Plastic Repair, Adhesive

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Wastewater Reuse. Typical treated wastewater is:

Ningbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes,

2KW CERAMIC HEATER DHCER20. User Manual

Ultra-Filter. Compressed Air Filter. DF Series

HYLA NST Cleaning System

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

The Impact of Fouling on the Performance of Filter- Evaporator Combinations

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

April 25, 2014 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

4.1 Dry Cleaning General 1,2

MATERIAL SAFETY DATA SHEET

pinta ACOUSTIC PANEL [1/7]

B Dinesh Prabhu, Asst. Professor, P E S College Engg., Mandya, KARNATAKA 1

Don t Spread Lead. A Do-It-Yourself Guide to Lead-Safe Painting, Repair, and Home Improvement

Effect of Thermal Barrier on Thermal Protective Performance of Firefighter Garments

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

MH 3M & 4M. High pressure washers with hot benefits

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

NAN YA NYLON 66 Engineering Plastics. Flame Retardant.High Toughness.Heat Resistant. Impact Resistant.Moldability.Low Warpage

International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement

Asbestos

Technical Cleaning Ó

Laminar Flow Cabinets and Workstations

Material Safety Data Sheet

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

car + boat Box Contents x2 x _DC16_CAR_BOAT_OPSMAN.indd 1 29/7/08 15:27:01

Air Induction Systems

DUST EMISSION MONITORING SYSTEM

Fume Hood Questions and Answers

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

74 Chapter CO 2 Cleaning

Material Safety Data Sheet

UNITOR ULTRASONIC cleaning

Good Boards = Results

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING.

EcoCWave. The all-round talent for aqueous part cleaning.

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

Pads for use on Dual Action / Random Orbital Sanders

Transcription:

SYNTHETICNON-WOVENFABRICS VILEDONAIRFILTER

VILEDON air filter is non-woven fabrics. VILEDON air filter is the high-quality non-woven fabrics radically new material developed by modern frontier technology of organic chemistry and polymer chemistry in harmony with paper and felt manufacturing technique. This new non- woven material has a remarkable variety; its physical and chemical properties can be freely designed according to its usage in combination with various synthetic fibers and many other materials. s of VILEDON air filter A p p l i c a t i o n For painting booth PA/350HL, PA/305HL M o d e l Page 5 For high temperature oven AI-100W, AE-100 (doubled), AE-100 6 Regenerative type for general use PS/600N, PS/400N, PS/300N, PS/150N 7 Disposal type for general use FR-585, FS-6200, FS-6500, PE/205HL, FR-580 8 For special equipments FS-1710, FS-1705, FS-1705W 9 For other usage FP-5615, FP-5505, FP-5205 FC-620N, FC-600 SS-3300, SS-1500, MV-50, MV-25 10 VILEDON air filter features: Completely bonded fabrics The fabrics has a porous structure. The pore sizes can be adjusted by the combination of fibers and binders according to its application. Optimum gradient of fiber density for air filter As the filter media density is increased away from upstream side to downstream side, the low pressure loss, the high dust collecting efficiency and the high dust holding capacity are available. (Some of our series have no density gradient.) Density gradient construction Easy and simple regeneration Our regenerative VILEDON air filters are reusable by water washing or spray cleaning. Fire-retardant and safety material VILEDON air filters fall under class 3 according to Flammability Test Method 11A-2003 of Japan Air Cleaning Association (JACA) for Materials of Air Purifier Filters, except the FR-580, which is not a fire-retardant product. Wide range of application VILEDON air filter are widely used for air-conditioning system of general office buildings and halls as well as modern frontier technological facilites of semiconductor factories. Applicalion marks for VILEDON air filter: 1 2 3 4 5 6 JACA No.11A-2003 7 8 [1] Applicable for painting booths [2] Applicable for package type air conditioners and other individual air conditioning systems [3] Applicable for outdoor air cleaning, etc. [4] For subway air [5] Washable type [6] Disposable type [7] Fire-retardant type [8] Non fire-retardant type 1

Washing way of VILEDON air filter Washable type VILEDON air filter can be regenerated by washing: Rinsing in water bath Water spraying Blowing with compressed air or vacuum cleaning To maintain the initial filter performance and property, please replace with new one after cleaning about 5 times for unit type and about 3 times for roll type filters. However, the number of cleaning times is depending on use condition and method of cleaning. Neutral detergent may be used for removing oily dust and dirt. To maintain the initial filter performance and property, please do not crumple or wring storongly. Natural drying is recommendable after washing. Please consult us or our agent for detail about regeneration method. Fire retardancy of VILEDON air filter Almost all VILEDON air filters are fire-retardant products falling under class 3 of evaluation standards except for some item. Be careful with fire, as VILEDON isn't nonflammable material. Though being fire-retardant,viledon air filter may burn with flammable dust and dirt collected. Keep it away from fire. Fire retardancy test method: The fire retardancy test method for VILEDON air filters uses JACA's 11A-2003. Under this test, the edge of each filter sample is exposed to a flame for 60 seconds under specified test conditions. Then the combustion speed, after-flame time, after-glow time, ignition caused by molten drops, and combustion distance are measured to evaluate the flammability of the filter material. Testing device Support 25-mm gauge line 60-mm gauge line 125-mm gauge line 175±25 38±1 13±1 Sample Supporting net Marking cotton Test piece supporting frame Edge of wing chip Mounting example Calculating formula of combustion speed(class 1 evaluation) (1) If the end of the sample damaged by after-flame or after-glowcombustion is in excess ofthe 125-mm gauge line, the combustion speed (V) will be calculated in the following formula. V = 6000 / tb (mm/min) tb : Combustion time (s) (2) If the end of the sample damaged by after-flame or after-glow combustion is in excess of 60-mm gauge line but not in excess of 125-mm gauge line, the combustion speed (V) will be calculated in the following formula. V = 60 Ld / tb (mm/min) Ld : Combustion distance tb : Combustion time (s) (3) The average value of five samples is calculated. Classification Fire-retardant type Combustion speed V(mm/min) After-flame time (s) Class 1 Class 2 Class 3 40 mm/min max. ( 40) N.A. N.A. N.A. below2 s for 4/5 ( 2 s) below10 s for 1/5 ( 10 s) below2 s for 4/5 ( 2 s) below10 s for 1/5 ( 10 s) JACA No.11A-2003 After-glow time of each sample N.A. 30 s max. ( 30 s) 30 s max. ( 30 s) Ignition of marking cotton caused by molten drops. N.A. Yes No Combustion distance Ld of each sample (mm ) Note) 4/5 : Four out of five samples. 35 mm or over ( 35) 1/5 : One out of five samples. 35 mm or below ( 35) 35 mm or below ( 35) 2

R VILEDON air filter is testing based on ASHRAE Dust collection efficiency is a vital property of air filters. To keep the efficiency reliable, air filters should be tested by the same method. They are tested by gravimetric, colorimetric and counting methods. Gravimetric method is applied to test the filters for general-use air conditioners and prefilters, colorimetric method is used for middle-and high-efficientry filters, and counting method is adopted for determination of performance of HEPA filters. Gravimetric and colorimetric methods of ASHRAE (American Society of Heating, refrigerating and Air conditioning Engineers ) are applied for testing our products. ASHRAE standard is adopted in EUROVENT(European standaed) and is recognized as a world wide standard. Counting method involves counting the dust particles by means of light scattering principle particle counter according to JIS standard. Air filter test methods Standard Test method Test dust Applied for ASHRAE 1992 Gravimetric Colorimetric ASHRAE test dust: 72% Arizona street dust 23% Carbon black 5% Cotton linter Atmospheric dust Filters for general-use air conditioners; Middle- and highefficiency filters Counting Form 1 Polydisperse DOP aerosol HEPA filters JIS 2001 Colorimetric Form 2 Gravimetric Form 3 JIS No.11(kanto loam) JIS No.15 : 72% JISNo.8 (kanto loam) 23% JISNo.12 (Carbon black) 5% Cotton linter JIS No.15(above) Middle-and higheffieiency filters Prefilters; Filters for general-use air conditioners Counting Form 4 Polydisperse DOP aerosol Electric dust-collecting machine ASHRAE= AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING ENGINEERS JIS=JAPANESE INDUSTRIAL STANDARD Standard Test method Test dust Applied for AFI Section-1 1953 Section-2 1960 Gravimetric Colorimetric AFI test dust: 72% Arizona street dust 25% Carbon black 3% Cotton linter Atmospheric dust Prefilters; Filters for general-use air conditioners Middle-and higheffieiency filters NBS 1944 Colorimetric EfficientyA : 96% Cottrell dust 4% Cotton linter EfficientyB : Atmospheric dust Filters for general-use air conditioners Middle-and higheffieiency filters AFI=AIR FILTER INSTITUTE NBS=NATIONAL BUREAU OF STANDARD AFI and NBS were integrated to ASHERE 3

ASHRAE Gravimetric method: ASHRAE test dust is supplied toward the test filter tested. Weight of dust collected on the absolute filter is calculated to determine the dust collection arrestance by the following formula: 1-- W2 W1 Ew= () 10 0 (%) EW W1 W2 - - - Dust collection arrestance (%) Dust quantity(supplied dust weight) Weight of collected dust on absolute filter Schematic drawing of testing device for determination of the filter arrestance 1-2- 3-4- 5-6- 7- Outdoor air Test filter Absolute filter Flow nozzle Exhausting air Dust feeder Manometer 1 6 2 7 3 4 5 ASHRAE Colorimetric method Atmospheric dust is sampled by the glass fiber filter arranged before and after the filter being tested. Based on contamination degree of each filter paper, dust collection efficiency is determined by the following formula: Q1 - O2 Q2 O1 1- - E= () 10 0 (%) E - Dust collection efficiency (%) Q1- Sampling flow rate at upstream side Q2- Sampling flow rate at downstream side O1- Contamination degree of filter paper at upstream side O2- Contamination degree of filter paper at downstream side Testing device for determination of the filter efficiency 1- Outdoor air 2- Filter paper holder 3- Test filter 4- Filter paper holder 5- Flow nozzle 6- Exhaust air 7- Intermittent sampling 8- Timer 9- Continuous sampling 10 - Vacuum pump 1 2 7 3 4 8 5 9 10 6 Measurement of filter thickness Filter thickness is measured under the specified load on the filter medium. Initial pressure loss Initial pressure loss is the center value. 4

JACANo.11A-2003 R VILEDON AIR FILTER FOR PAINTING BOOTH Characteristics of filter for painting booth : This filter allows for removing almost all dust suspended in air,especially visible coarse particles (more than 10μm),to eliminate the painting troubles. PA/350HL and PA/305HL are the most suitable filtering media for painting booth.pa/350hl has a sticking property to prevent of dust break-through. PA/305HL Standard specifications Standard size (W L ) PA/350 HL 18±3 >98 Polyolefin 1.6 20 m 0.5 45 80 PA/305HL 19±3 98 Air Velocity & Pressure drop Pressure drop(pa) Air Velocity (m/s) 5

JACANo.11A-2003 R VILEDON AIR FILTER FOR HIGH TEMPERATURE OVEN Characteristics of high temperature oven filter This filter allows for effective filtering of tars, soots,rusts,etc.produced in high temperatre oven to prevent fouling of product surface. This filter made of special synthetic fibers has enough durability at high temperatures and is very easy in handling, as distinguished from glass fibers which may be broken and airborned when replacing the filtering media. AI-100W is applicable for 180 240,and AE-100 or AE-100 doubled is applied for temperaturelessthan180. AI-100W AE -100 Standard specifications Standard size (W L ) AI-100W AE-100 doubled Aromatic polyamide AE-100 500 500mm 1.6 20m 20±3 20±4 10±2 1.0 45 25 90 88 240 180 180 Air Velocity & Pressure drop Pressure drop(pa) AI-100W,AE-100doubled Service life of the filter depends on its working temperature. As its durability is depends on an air velocity, running hour, atmosphere and other conditions, please consult us when operating it at the conditions other than given in the standard specifications. Air Velocity (m/s) 6

JACA No.11A-2003 R VILEDON AIR FILTER REGENERATIVE TYPE FOR GENERAL USE Characteristics of washable type filter for general use : This filter is an optimal filter for outdoor air filtration. The filter is washable several times simply. It is used mainly for panel type unit. PS/600N and PS/400N are applicable for automatic roll filter(vmr). PS/600N Standard specifications PS/600N PS/400N PS/300N PS/150N 1.6 20m 20 3 90 82 Polyester/Modacrylic 14 2 64 76 2.5 80 1.6 30m 10 2 54 73 8 2 30 63 PS/600N,PS/400N,PS/300N : These items are less-formaldehyde products. Air Velocity & Pressure drop Pressure drop (Pa) Air Velocity (m/s) 7

JACA No.11A-2003 R VILEDON AIR FILTER DISPOSAL TYPE FOR GENERAL USE Characteristics of disposable type filter for general use : This disposable type filter is best suited for outdoor air filtration. It is recommended to use FR-585 for automatic roll air filter ( VMR) in respect of running cost. This filter is very effective to collect sandy dust,as sticking oil is applied to increase dust collection arrestance. Cut-to-size sheets (500 500 mm,610 610 mm, etc.)of FR-585 are available for panel type. FR-585 is non-halogen filters. Dioxins will not be brought by incinerating the FR-585. FR-585 Standard specifications FR-585 Polyolefin 1.73 20m 18 3 59 85 FS-6200 Modacryl/ Polyester 1.6 15m 14 2 FS-6500 Polyester/ Modacrylic 1.6 20m 13 2 PE/205HL Polyolefin 1.6 20m 18 3 *FR-580 Polyolefin 1.6 20m 20 3 2.5 1.0 2.5 54 35 40 54 78 90 90 80 60 *FR-580 isn't fire-retardant. Air Velocity & Pressure drop Pressure drop (Pa) Air Velocity (m/s) 8

JACA No.11A-2003 R VILEDON AIR FILTER FOR SPECIAL EQUIPMENTS Characteristics of filter for special equipments: This filter is distinguished for its low pressure drop,high dust collecting arrestance and large dust holding capacity.it can be subjected to resin molding and zigzag pleats processing. FS-1710 Standard specifications FS-1710 FS-1705 Polyamide/ Modacrylic Polyester/Modacrylic 1.0 50m 1.0 50m 1.0 50m 11 2 5.5 1.5 6.5 1.5 2.5 35 74 60 20 68 FS-1705W Air Velocity & Pressure drop Pressure drop (Pa) Air Velocity (m/s) 9

R VILEDON AIR FILTER FOR OTHER USAGE JACA No.11A-2003 Pleated filter for FP-5615 Polyolefin 20 3 1.0 92 97 1.6 20m FP-5505 Polyester/ Modacylic 13 2 2.0 92 88 60 FP-5205 Polyester/ Modacylic 1.6 15m 14 2 2.5 54 78 JACA No.11A-2003 Mist and lint filter FC-620N Modacylic/ Polyamide 1.2 0.5 2.0 74 1.6 50 m 35 60 FC-600 Polyamide/ Polyester 2.3 0.5 0.5 97 JACA No.11A-2003 Capillary filter,de- watering filter: SS-3300 50 5 30 66 Vinylidene chloride 500 500 mm 2.5 60 SS-1500 25 3 15 52 MV-50 50 5 30 66 Vinylidene chloride 500 500 mm 2.5 60 MV-25 25 3 15 52 10

INSTRUCTION FOR USE These filtration products are designed for air cleaning applications only. For new or nonstandard applications, please consult our company or our agent to ensure that the correct product is specified. Overseas contact Germany Freudenberg Filtration Technologies KG 69465 Weinheim Gemany Tel.+49-6201-80-6264 Fax.0049-6201-88-6299 China Freudenberg & Vilene Nonwovens(Suzhou)Co.,Ltd. 1588 Bin He Road,Suzhou 215011,People's Republic of China Tel.+86-512-6825-1586 Fax.0086-512-6824 1942 Thailand Freudenberg & Vilene Filter(Thailand)Co.,Ltd. Amata Nakorn Industrial Estate Phase 4, 700/427 Moo 7,Tambol Don Hua Roh,Amphur Muang,Chonburi 20000,Thailand Tel.+66-38-453-214 Fax.0886-3478 1260 Taiwan Freudenberg & Vilene Nonwovens(Taiwan)Co.,Ltd. No.40,Min-Fu Road,Section 2,Yang-Mei,Tao-Yuan,Taiwan,R.O.C Tel.+886-3-478-1261~3 Fax.0886-3478 1260 Korea Korea Filtration Technologies Co.,Ltd. 417-7,Tojin-ri,Cheongbuk-myeon,Pyeongtaek-si,Gyeonggi-do,Republic of Korea Tel.+82-31-683-6814 Fax.0082-2-2185-0111 AIR-FILTERS DEPT. Head office 5-6-4, Tsukiji, Chuo-ku, Tokyo 104-8423, JAPAN TEL.+81-3-4546-1166 FAX.+81-3-4546-1162 The contents of the product carried to this catalog may be changed without a preliminary announcement by improvement of quality etc. This catalog is made from recycled paper. 2013.06.DP.0000