PC/MPI+ RS232 isolated Siemens S7-300/400 PLC Programming adapter Optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.can connect PLC and the touch panel of third party factory to communicate.it doesn't support profibus function. PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface). PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system. PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eview, Wei-lun and kun-lun state.
Characteristics and main technical parametres: Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1W, with overcurrent protection and surge protection. Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.) RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w. RS232 port baud rate: 19.2Kbps---115.2Kbps, automatically adaptable to the standard baud rate. MPI port baud rate: 187.5Kbps---19.2Kbps, automatically adaptable. Supporting the connection of PLC to touch-screen communication with the third party. With a power indicater light, on-line and data transmission indicater light. Working temperature: -20~75 Dimension: 103 50 26; After connecting the RS232 cables: 5.5m.
RS232 adapter port and port-pin RS485 signal definations: RS232-Block(DB9M) defination signals RS485-Block(DB9M) defination signals Pin Signal Instructions Pin Signal Instructions number name number name 1 DCD No use 1 NC No use 2 RXD RS232 signal reception 3 TXD RS232 signal sending 4 DTR Short circuit with No.6 5 GND RS232 signal to ground 2 M24V Negtive 24VDC power 3 B RS485 positive signal 4 RTSAS Data reception control 5 GND RS485 signal to ground 6 DSR Short cut with No.4 6 NC No use 7 RTS Sending requsts 7 P24V 24VDC positive power 8 CTS Sending clear 8 A RS485 negtive signal 9 RI No use 9 RTS_PG Data-send control
Instructions of the indicater light Indicater On Qlittering Out light Power Normal Error Error or failing to link to power Active Online Transmission of data Not online Tx Error Send data No data transmission Software settings of STEP7: Entering the main interface of STEP7 programming software (SIMATIC Manager), clicking on Options menu under the Set PG/PC Interface option into the PG/PC interface settings. 1. Double clicking on PC Adapter(MPI) into the RS232 interfaces and MPI set of parameters. The adapter does not support PC Adapter(PROFIBUS) option. 2. Clicking on Local Connection option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication. 3. Clicking MPI to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set. 4. On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.
The long-distance communication of PC/MPI+ adapter: 1. To extend the distance of RS485 port:
2. To extend the distance of RS232 port: RS232 Cable: When you buy PC/MPI+,we will give you the free RS232 Cable.
The quality is guaranteed.it's tested before shippment.not made by Siemens,OEM product as the replacement. Can replace Siemens 6ES7 972-0CA23-0XA0