HE220A,B and HE260A,B Bypass Flow-Through Humidifier



Similar documents
Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Owner s Manual For Models 400, 550, 600 & 700

T7079A,B Solid State Remote Temperature Controllers

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

AMX300 DirectConnect Mixing Valve Kits

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

UV100A Ultraviolet Air Treatment System

Central Air Conditioner

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

CARING FOR YOUR WATER HEATER

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Installation Instructions

Geyser-R Heat pump water heater Installation manual

Cooktop Low-Profile Ventilation Hoods

Installation Instructions

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Portable Air Conditioner

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Oil and Coolant Circulating Heating System. Model - OCSM

air conditioners how to choose a cooling system

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Air Conditioning System

Installation Instructions* for High-Capacity Steam Humidifiers

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Important Safeguards

Y7230A CO 2 Alarm System

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

MCR1900 Media Converter 19-Slot Chassis

Single Zone LCD Thermostat Operating Instructions

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP

THREE. Heating and Cooling

LOBOY 16 AIR CONDITIONERS

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

CENTRAL AIR CONDITIONER A GUIDE TO OPERATING AND MAINTAINING YOUR RESIDENTIAL AIR CONDITIONING UNIT.

Glossary of Heating, Ventilation and Air Conditioning Terms

Chilled Water HVAC Systems

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

OPL BASIC. Dosing System for Professional Laundry machines. Contents

USER S MANUAL HSC-24A

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

SunMaxx Solar Filling Station Operating Instructions

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

PORTABLE AIR CONDITIONER

Ceiling Mount Air Handler Manual

Bring the fresh in. Dedicated Outside Air Systems

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

CENTRAL AIR CONDITIONER with PURON REFRIGERANT

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Please keep this manual for f uture reference.

Dehumidification Frequently Asked Questions

Installation Instructions

Watts Pure Water Systems

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Dehumidifier Users manual. For Models: DH45S DH65S

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Line to Refrigerator Ice/Water Dispenser

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA


Use and Care Manual. Model CPA12KH AIR CONDITIONER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

How to Maintain an Air Conditioner

, User s Manual

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Table of Contents. 1 - Specifications Installation Wiring User controls...7

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

Make sure oven is OFF. Never remove parts or touch the fan unless the oven is OFF.

AIR CONDITIONER INSTALLATION MANUAL

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

Air Conditioning Sign-Off Sheet

Table Z. Troubleshooting Chart for Air Conditioners. Cause

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

HEAT PUMP PROGRAMMABLE THERMOSTAT

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Transcription:

HE220A,B and HE260A,B Bypass Flow-Through Humidifier FEATURES/BENEFITS PRODUCT DATA Capable of humidifying a large area. Proven technology used for high performance humidification and enhanced comfort. Preassembled for quicker installation. Small footprint, light weight and reversible components allow easy mounting on either warm air supply or return air duct of any forced air furnace. Interior components designed for quick maintenance and service. Includes easy-to-use humidity control which mounts on the wall or duct for more installation flexibility. Perfect Climate Comfort Center control can be installed to replace both the thermostat and humidity control for improved aesthetics and convenience. APPLICATION Continuous flushing reduces the frequency of maintenance in a hard water installation. The HE220A,B and HE260A,B Bypass Flow-through Humidifiers use the warm air furnace blower to provide humidification for the whole house. The humidifiers work with virtually any Honeywell humidity control, but use the Honeywell Perfect Climate Comfort Center control for optimal performance. Contents Application... 1 Features/Benefits... 1 Specifications... 2 Ordering Information... 2 Installation... 3 Wiring the Humidifier... 4 Plumbing the Saddle Valve... 5 Checking the installation... 5 Operating the Humidifier... 5 Operation... 6 Maintenance... 6 Checkout Procedure... 7 Troubleshooting... 7 Replacement Parts... 8 U.S. Registered Trademark Copyright 1998 Honeywell Inc. All Rights Reserved 68-0191-3

SPECIFICATIONS Capacity: At 120 F (49 C) plenum temperature and 0.20 static pressure drop across supply and return: HE220A,B: 12 gallons per day (gpd) or 46 liters per day (lpd). HE260A,B: 17 gallons per day (gpd) or 65 liters per day (lpd). Humidified Area: See Table 1. Electrical Ratings: 24 Vac, 60 Hz, 0.5A. Plenum Opening Dimensions (Height x Width): See Table 3. Summer Shut-off Damper Dimensions (Height x Width): See Table 4. Bypass Duct Opening (Diameter): 6 in. (152 mm). Drain Connection: 1/2 in. (13 mm) I.D. plastic hose connected directly to drain fitting on unit. Dimensions: Refer to Fig. 1 and 2. Humidifier Pad Dimensions: See Table 2. Table 1. Size Of Area That Can Be Humidified. HE220 Area (Up To) HE260 Area (Up To) House Description Air Changes Per Hour Sq ft Sq m Sq ft Sq m Loose Two 750 70 1,000 93 Average One 1,500 140 2,000 186 Tight One-half 3,000 280 4,000 372 Table 2. Dimensions Of Humidifier Pads In In. (mm). Model Height Width Depth HE220 9-13/16 (249) 9-1/2 (241) 1-1/2 (38) HE260 13 (330) 10 (254) 1-1/2 (38) Table 3. Dimensions Of Plenum Opening In In. (mm). Model Height Width HE220 9-7/16 (241) 9-5/16 (238) HE260 12-5/8 (321) 9-3/4 (248) Table 4. Dimensions Of Summer Shut-off Damper In In. (mm). Model Height Width HE220 9-3/16 (234) 8-7/8 (226) HE260 12-3/8 (314) 9-5/16 (236) ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Logistics Honeywell Inc., 1985 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0191 3 2

9-1/8 (232) Standard: Air Conditioning and Refrigeration Institute Tested: Standard 610. 11-7/16 (290) 12 (305) 12-7/16 (316) Models: HE220A TRADELINE and HE260A TRADELINE Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H908A Convertible Humidity Control. HE220B TRADELINE and HE260B TRADELINE Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H1008A Automatic Humidity Control with HumidiCalc Software. 13-9/16 (345) 6 (152) DIAMETER Fig. 1. Dimensions of HE220A,B in in. (mm). M12245 Accessories: Current Sensor Relay, part no. 32001754-001. C7089H Outdoor Temperature Sensor. H908A Convertible Humidity Control. H1008A Automatic Humidity Control with HumidiCalc+ Software (software calculates dewpoint to prevent moisture condensation). HC22A Humidifier Pad (HE220A,B only). HE26A Humidifier Pad (HE 260A,B only). HumidiCalc+ Humidifier Sizing Software (software calculates required humidifier capacity for application). PC8900 Perfect Climate Comfort Center Control. S688 Sail Switch. 9-1/4 (235) 13-9/16 (345) 12 (305) INSTALLATION WARNING Hazardous Voltage. Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning line or electrical accessory. 16-3/4 (425) 6 (152) DIAMETER 15-5/16 (390) M12251 CAUTION Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage to home or permanent equipment damage. The humidifier must be located where the ambient temperature is above 32 F and below 160 F (0 C and 71 C). Be sure supply plenum static pressure is no greater than 0.3 in. w.c. and water pressure is no greater than 125 psi. IMPORTANT To assure optimal product performance, be sure the template is level before marking location. Fig. 2. Dimensions of HE260A,B in in. (mm). 1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 3. Approvals: Underwriters Laboratories Inc. Listing: 56 BL. Canadian Underwriters Laboratories Inc. Listing: 56 BL. 3 68-0191 3

11. Reinstall the humidifier pad assembly in the humidifier housing. HORIZONTAL HIGHBOY Be sure the water feed tube is not pinched or kinked. 12. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover. COVER WATER FEED NOZZLE HUMIDIFIER PAD ASSEMBLY DOWN FLO FRAME LOWBOY HUMIDIFIER HOUSING M12248B Fig. 3. Typical humidifier installation locations. SIDEWALL WATER FEED TUBE IMPORTANT Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate space for the solenoid valve and drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. 2. Tape the template in position and trace around the template. 3. Remove the template and carefully cut the rectangular opening. 4. Disassemble the humidifier; remove the cover and take out the humidifier pad assembly. See Fig. 4. BYPASS SIDEWALL Fig. 4. Humidifier components. M12304 Sidewalls are interchangeable for either left or right by-pass installation. To change direction, remove the screws holding each sidewall, switch sidewall locations and reinstall the screws. 5. Position the humidifier housing in the opening (be sure it is level), so the locking tabs are in place on the lower sheet metal edge of the opening. 6. Secure the humidifier housing to the opening at the top and bottom using sheet metal screws. 7. Locate the other plenum and cut an opening for a 6 in. (152 mm) collar. 8. Install the 6 in. (152 mm) collar. Be sure to install a duct damper for summer shutoff on systems with air conditioning. 9. Install a 6 in. (152 mm) diameter duct from the collar to the humidifier. Some installations require a 90 elbow attachment to the collar. WIRING THE HUMIDIFIER CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Disconnect the power supply before installing or servicing. On multispeed blower applications, do not wire the high voltage side of the transformer to the same power source that services the furnace blower. Premature transformer burnout may occur. All wiring must comply with applicable local codes, ordinances and regulations. 1. Mount the transformer in a convenient location. 2. Connect wires to the 120V side of the transformer. 3. Wire the humidifier solenoid valve, current sensing relay, or sail switch, humidity control and transformer. Refer to the humidity control installation instructions for mounting and wiring information. 10. Seal the duct connections with duct tape. To avoid sagging and stress on the humidifier, add support when ducting is longer than 4 ft (120 cm). Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed. 68-0191 3 4

PLUMBING THE SADDLE VALVE Hot or cold water, either hard or softened, can be used in the humidifier. 1. Use the self-piercing saddle valve (included) to tap into the water supply line at an appropriate location. IMPORTANT The saddle valve is not designed to regulate water flow. The valve is either open or closed. To prevent debris from clogging the solenoid inline filter, be sure to install the saddle valve handle pointing toward the ceiling. Lightly clean the copper tubing ends with fine sandpaper before making any connections. 2. Use 1/4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve. CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. a. Place the brass compression nut over the copper tubing. Do not over tighten the compression nut. Moderate tightness prevents leaking. b. Slide the brass ferrule over the tubing. c. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. 3. Connect a 1/2 in. (13 mm) drain tube to the humidifier drain fitting and run to a suitable drain. Slope the drain tube downward for correct drainage. CHECKING THE INSTALLATION Use the following procedure to check out the humidifier installation: 1. Open the saddle valve. 2. Set the thermostat setpoint to 10 F (6 C) above the room temperature. The furnace blower must be on for the humidifier to operate. 3. Set the Convertible Humidity Control to a high setting, or place the H1008A Automatic Humidity Control in the Test position. 4. Observe the water running out of the drain line to be sure the humidifier is working. 5. Check for leaks. 6. Reset the thermostat and Convertible Humidity Control to a comfortable setting, or the Automatic Humidity Control to the desired frost factor setting, for automatic operation. OPERATING THE HUMIDIFIER The HE220A and HE260A Humidifiers are controlled by the Convertible Humidity Control that is installed either on an interior wall in the living area or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on the humidity control dial. Match the dial setting to the H908A outdoor temperature for optimizing the humidity level while reducing the moisture condensation on inside windows. Table 5 can also be used to adjust the humidity control to the recommended setting. As the outside temperature drops, the recommended setting is lowered to accommodate the effects of dewpoint. These settings should reduce the accumulation of moisture and ice on the windows and in other areas of the house. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on the windows. If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture. The Honeywell HE220B and HE260B Humidifiers are controlled by the Honeywell H1008A Automatic Humidity Control with HumidiCalc+ Software. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air. The HumidiCalc+ Software inside the automatic humidity control H1008A is designed to automatically adjust the humidity level based on indoor temperature and humidity, inferred or measured outdoor temperature, and the setting of the frost factor dial. The frost factor allows for variations in furnace size, window insulation and average daily climate temperature. M14231 M12817 The Automatic Humidity Control with HumidiCalc+ Software requires an initial adjustment period. Set the frost factor dial on 5 and use Table 6 to adjust the frost factor only one setting at a time increasing the dial setting for more humidity, or reducing the setting if moisture develops on inside windows. For more precise humidity adjustment, set the frost factor between dial settings. Allow two days for the humidity level to subside before making further adjustments. Once the proper setting has been found, no further adjustment is needed. HumidiCalc+ Software takes over and makes any future adjustments caused by varying outdoor temperatures, thus reducing moisture build-up on windows while maintaining the optimal humidity level. 5 68-0191 3

Table 5. Recommended Convertible Humidity Control Settings. At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting -20 F (-29 C) 15 +10 F (-12 C) 30-10 F (-23 C) 20 +20 F (-7 C) 35 0 F (-18 C) 25 Above 20 F (-7 C) 40 Insufficient humidity Humidity Level Condensation on windows Table 6. Recommended Frost Factor Settings. Recommended Adjustment Increase the frost factor dial by one setting. Decrease the frost factor dial by one setting. OPERATION The HE220A,B and HE260A,B Humidifiers use the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises. The humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that disburses water over a humidifier pad. The warm dry air from the furnace passes over the humidifier pad and collects moisture and them circulates it through the house. Humidified air feels warmer and more comfortable so the homeowner may be able to lower the thermostat heating setpoint and save money on heating fuel bills. The end result is that the humidifier gives the homeowner a comfortable environment that is also energy efficient. MAINTENANCE Every 1 to 3 Months (Depending on Water Quality) Use the following procedure to clean the humidifier: 1. Disconnect the power and turn off the humidifier water supply. 2. Remove the humidifier cover. See Fig. 5. COVER SIDEWALL WATER FEED NOZZLE HUMIDIFIER PAD ASSEMBLY HUMIDIFIER HOUSING FRAME WATER FEED TUBE A regular maintenance program prolongs the life of the humidifier and provides a more comfortable environment. Either hard or soft water can be used in the humidifier. Frequency of cleaning depends on the condition of the water. CAUTION Voltage Hazard. Can cause electrical shock and equipment damage. Disconnect power supply before installing or servicing. BYPASS SIDEWALL Fig. 5. Location of humidifier parts. M12304 IMPORTANT Never oil any part of the humidifier. 3. Remove the humidifier pad assembly from the humidifier by grasping the tray and pulling it toward you. 4. Pull one side of the humidifier pad assembly frame toward you and remove the tray from the frame. 5. Gently pinch the water nozzle catches inward until the water nozzle can be lifted off the tray. 6. Slide the humidifier pad out of the frame. 7. Carefully scrape any mineral deposits from the tray and frame. Be sure the frame drain hole has nothing blocking it. 8. Check the humidifier pad and if excessive mineral deposits are present, replace with a new pad. 68-0191 3 6

9. Disconnect the tube from the drain fitting on the bottom of the humidifier housing. 10. Clean the drain fitting, if necessary. 11. Bend the drain tube to loosen any mineral deposits. 12. Flush the drain tube with pressurized water (a running tap) to clean the tube. 13. Reattach the drain tube to the drain fitting. 14. Slide the humidifier pad back into the frame. IMPORTANT Be sure the marked side of the humidifier pad is facing up for proper performance. 15. Snap the water nozzle back on the tray. 16. Reattach the tray to the frame. 17. Place the humidifier pad assembly in the humidifier housing and press until the assembly is completely seated. Be careful not to pinch or kink the water feed tube. 18. Replace the humidifier cover. 19. Verify the humidifier operation by following the steps in the Checkout Procedure section. End of Humidification Season At the end of the heating season, follow steps 1 through 18 from the Every 1 To 3 Months section to clean the humidifier and shut if off. IMPORTANT Be sure the humidifier power is off. Beginning of Humidification Season Refer to the Checkout Procedure section to complete the humidifier startup. Vacation When leaving on vacation, turn off the humidifier water supply and the humidity control. When returning from vacation, turn on the humidifier water supply and reset the humidity control to restart the humidifier. CHECKOUT PROCEDURE After winter startup or servicing, use the following procedure to check the humidifier operation: 1. Turn on the humidifier power and water supply. 2. Turn the Convertible Humidity Control to the highest setting, or place the H1008A Automatic Humidity Control in the Test position and set the thermostat to 10 F (6 C) above the room temperature. 3. Observe that water is flowing out of the drain hose. The furnace blower must be on for the humidifier to operate. 4. Reset the thermostat and Convertible Humidity Control to a comfortable setting, or the H1008A Automatic Humidity Control to the desired frost factor setting, for automatic operation. TROUBLESHOOTING Refer to Table 7 for troubleshooting procedures. Table 7. Troubleshooting Procedures. Problem What To Look For What To Do Low humidity Furnace blower not operating Reset circuit breaker or check for blown fuse. Check that the furnace power is on. Check all external wiring connections. Check the humidity control setting. Call a professional heating contractor. Rapid air changes. Drafts (cold air is dry and is an added load to the humidifier). Keep doors and windows closed. Close fireplace damper when not in use. Keep exhaust fan running time to a minimum. Seal around doors and windows. High humidity Condensation on walls. Turn humidity control and water off until condensation is completely evaporated. Heavy condensation on windows. Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. 7 68-0191 3

REPLACEMENT PARTS Refer to Fig. 6 and Table 8 when ordering replacement parts. 10 4 9 8 11 5 6 12 3 13 7 1 8 Fig. 6. Exploded view of humidifier parts. 2 8 M12303A 68-0191 3 8

Table 8. List Of Replacement Parts For HE220A,B, HE260A,B Humidifiers. Exploded View Number Description HE220 Part Number HE260 Part Number 1 Side wall 32001612-001 32001626-001 2 Bypass side wall 32001613-001 32001627-001 3 Cover Assembly 32001611-001 32001611-002 4 PerfectFlo water distribution tray 32001619-001 32001630-001 5 Humidifier pad HC22A1007 HC26A1008 6 Frame 32001621-001 32001632-001 7 Drain fitting 32001615-001 32001615-001 8 Solenoid valve assembly (includes water feed tube and nozzle) 32001639-002 32001639-002 9 Saddle valve assembly 32001616-001 32001616-001 10 Transformer (10 VA) 32001652-001 32001652-001 11 Convertible Humidity Control H908A1003 H908A1003 12 Automatic Humidity control with HumidiCalc + Software H1008A1008 H1008A1008 13 Base insert assembly, includes no. 8 above 32001625-001 32001625-002 Hardware Kit for Solenoid Assembly (same as Solenoid valve assembly without the solenoid valve) 32001752-001 32001752-001 Current Sensing Relay 32001754-001 32001754-001 9 68-0191 3

68-0191 3 10

11 68-0191 3

Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 3N7 Honeywell Europe S.A. 3 Avenue du Bourget 1140 Brussels Belgium Honeywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong Printed in U.S.A. on recycled 68-0191 3 J.S. Rev. 6-98 paper containing at least 10% post-consumer 12paper fibers. www.honeywell.com/yourhome