App. Note # FTMS-47+MT-113 MALDI Imaging with Single Cell Resolution at 10 µm Pixel Size

Similar documents
Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Copyright 2007 Casa Software Ltd. ToF Mass Calibration

Pesticide Analysis by Mass Spectrometry

Tutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

The Olympus stereology system. The Computer Assisted Stereological Toolbox

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Care and Use of the Compound Microscope

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Choices, choices, choices... Which sequence database? Which modifications? What mass tolerance?

Tutorial 9: SWATH data analysis in Skyline

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

Micromass LCT User s Guide

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Alignment and Preprocessing for Data Analysis

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

ALLEN Mouse Brain Atlas

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

Compartmentalization of the Cell. Objectives. Recommended Reading. Professor Alfred Cuschieri. Department of Anatomy University of Malta

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Bio and Polymer Analytics. RD Instrumental Analytical Chemistry. Organic Trace Analytics. RD Environmental & Process Analytics

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Appendix 5 Overview of requirements in English

Explain the role of blood and bloodstain patterns in forensics science. Analyze and identify bloodstain patterns by performing bloodstain analysis

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Functional Data Analysis of MALDI TOF Protein Spectra

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

MASCOT Search Results Interpretation

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

ProteinPilot Report for ProteinPilot Software

MIRAX SCAN The new way of looking at pathology

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

Mass Spectrometry Signal Calibration for Protein Quantitation

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

A Streamlined Workflow for Untargeted Metabolomics

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Mass Frontier 7.0 Quick Start Guide

Preprocessing, Management, and Analysis of Mass Spectrometry Proteomics Data

Image Lab Software for the GS-900 Densitometer

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Per Andrén Dept. of Pharmaceutical Biosciences Medical Mass Spectrometry, Uppsala University, Uppsala, Sweden

CELERY LAB - Structure and Function of a Plant

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

Application Note. Single Cell PCR Preparation

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Scanners and How to Use Them

New drugs of abuse? A case study on Phenazepam & Methoxetamine

AMD Analysis & Technology AG

Name Date Hour. Nerve Histology Microscope Lab

Technical Considerations Detecting Transparent Materials in Particle Analysis. Michael Horgan

LIST OF FIGURES. Figure 1: Diagrammatic representation of electromagnetic wave. Figure 2: A representation of the electromagnetic spectrum.

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Physics 441/2: Transmission Electron Microscope

[ Care and Use Manual ]

Protease Peptide Microarrays Ready-to-use microarrays for protease profiling

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Thermo Scientific SIEVE Software for Differential Expression Analysis

1. Examine the metric ruler. This ruler is 1 meter long. The distance between two of the lines with numbers on this ruler is 1 centimeter.

Calibration of Volumetric Glassware

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Electromagnetic Radiation (EMR) and Remote Sensing

Fluorescence Microscopy for an NMR- Biosensor Project

Integration of a fin experiment into the undergraduate heat transfer laboratory

Fractional Distillation and Gas Chromatography

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

SELDI-TOF Mass Spectrometry Protein Data By Huong Thi Dieu La

using ms based proteomics

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

DETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm

Digital Remote Sensing Data Processing Digital Remote Sensing Data Processing and Analysis: An Introduction and Analysis: An Introduction

ForensicDB: A Web-accessible Spectral Database

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Nuclear Magnetic Resonance notes

WebEx Sharing Resources

Measuring Line Edge Roughness: Fluctuations in Uncertainty

Master course KEMM03 Principles of Mass Spectrometric Protein Characterization. Exam

Transcription:

pp. Note # FTMS-47+MT-113 MLDI Imaging with Single Cell Resolution at 10 µm Pixel Size bstract Key parameters for MLDI imaging are spatial resolution and mass spectral quality. In this application note, we explore the feasibility of single cell imaging. Typically, high spatial resolution requires matrix preparation that is drier than usual and often is limited to high abundant lipid species. For the high resolution imaging presented here, we utilized a dry sublimation device, which enabled us to perform MLDI imaging at a spatial resolution of 10µm and to resolve individual cells in tissue images. The 10 µm pixel size was achieved on both solarix FTMS and autoflexspeed and ultraflextreme platforms. uthors Michael ecker, Eckhard elau, Sören-Oliver Deininger, Jens Fuchser ruker Daltonik GmbH, remen, Germany Shannon Cornett ruker Daltonics, illerica, M, US Keywords MLDI Imaging FTMS MLDI-TOF Instrumentation and Software solarix MLDI-TOF

Introduction Interest in MLDI imaging has grown significantly in recent years with applications in the fields of histology, histopathology, drug development and others. Several performance factors are relevant to mass spectrometric imaging techniques, such as spatial resolution, analysis speed, and mass spectral quality. Usually the optimization of one of these factors is detrimental to the others, so in real-life, experiments are often not done at the limits of spatial resolution. Nevertheless, in this application we focus on the optimization of spatial resolution. Sample preparation is an important factor for achieving high resolution MLDI imaging. Often, the MLDI matrix is applied as solution in the form of an aerosol. The solvent droplets extract the compounds of interest which are subsequently incorporated in the matrix for the measurement. For many compounds, such as drugs or proteins, a wet sample preparation (longer aerosol) leads to a better spectral quality, but at the same time leads to larger matrix crystals, thereby limiting the maximum spatial resolution. Especially for highly abundant lipids, it has been shown that matrix can be applied in a dry fashion [1], which leads to small matrix crystal size and therefore allows a higher spatial resolution. In this study, we used sublimation to apply matrix onto the prepared slides. This allows a very high spatial resolution because no solvent is involved [2] and is especially suited to assess the instrument-based limits of the lateral resolution. Spatial resolution in imaging mass spectrometry Within the field of mass spectrometric imaging spatial resolution can be defined differently. Often, the term spatial resolution is used synonymously with the achievable raster width (i.e. pixel size ) or the geometric distance between spectra. In these cases, technical features such as minimum laser focus diameter and precise sample stage movement are considered the limiting factors (in the absence of large matrix crystals). To determine the highest spatial resolution that we could achieve on biological tissue we selected rat cerebellum and testis tissue as test specimens. In each testis section there are a number of structures of different sizes including tubuli, interstitial spaces and differing layers of cells on the outside of each tubule as well as in the lumen. In the cerebellum organized layers of individual large neurons, the Purkinje cells, have a soma diameter of 30µm. The goal of this study was to prepare and analyse these samples such that the smallest of these features was well resolved in the ion images. Experimental Cryosections of fresh-frozen rat cerebellum and testis were cut at 10µm thickness and thaw-mounted onto indium-tin-oxide (ITO, ruker) coated glass slides. Sample slides were not washed and directly desiccated in a vacuum desiccator for 1 hour. Sublimation was performed in a custom built device using a 152 mm inner diameter sublimation apparatus (ce Glass, NJ, US) exactly as described in Chaurand et al. [2] using 2,5-dihydroxybencoid acid as matrix. MLDI imaging measurements were performed on commercially available Ultraflextreme, utoflex Speed and Solarix (all ruker) instruments equipped with a smartbeam II laser. The standard laser setting of minimum diameter was used exclusively for all measurements. FlexImaging 3.0 software (ruker) was used to set up the imaging measurements and to generate ion images from the acquired data. MLDI-TOF images were normalized to total ion count (TIC), MLDI-FTMS images were normalized to root mean square (RMS) intensity. The intensity thresholds for the reconstructed MLDI images were adjusted to result in bright images and low noise. fter image collection, slides were removed and washed in ethanol to remove matrix and stained using a standard Hematoxylin and Eosin (H&E) protocol. Microscopic images were acquired on a Mirax desk slide scanner (Zeiss). Results MLDI-TOF imaging Figure 1 shows an illustration of the main features of rat cerebellum, including white matter, granular layer, Purkinje cell layer and molecular layer. Purkinje cell soma have an average diameter of ~30 µm in rat which are well separated from each other and therefore are ideal structures to test MLDI Imaging spatial resolution. Figures 2-4 show a selection of MLDI images of lipids from rat cerebellum at increasing magnification. Figure 2 shows two reconstructed MLDI images of five selected mass signals and an optical image of the measured area. In Figure 2a, the mass signal at 815.7 Da (displayed in red) is localized to the cerebellar white matter and the signal at 849.7 Da (in blue) is found in the granular layer. The mass signal at is seen as a line of green dots that correspond to individual Purkinje neurons. The signal at is seen in Figure 2b as a well-structured image of several anatomical features.

Simplified anatomy of rat cerebellum Figure 1: : The main structure in the cerebellum is comprised of cerebellar white matter (WM) surrounded by the granular layer (GL). The granular layer is surrounded by a single layer of Purkinje cells (PCL), which is in turn surrounded by the molecular layer (ML). : Enlarged area as marked, the Purkinje cells are large cells with irregular spacing. In mouse cerebellum, the diameter of Purkinje cells is ~30 µm. MLDI images of rat cerebellum WM GL ML C PCL 815.7 Da 849.7 Da Figure 2: MLDI images from part of rat cerebellum acquired at 10µm pixel size. : Three selected masses which show cellular localization: the mass signal in green highlights the individual Purkinje cells; the mass signal 815.7 Da in red is found in the cerebellar white matter; and the mass signal 849.7 Da is found in the granular layer. : Two selected mass signals that show strong differentiation, the mass signal at also exhibits spatial differentiation according to intensity range. C: Optical image of the measured cerebellum with measured region shown for context. ll scale bars: 200 µm. WM Enlarged figure on the back side GL Purkinje Cells ML Figures 3a-b show, in progressively greater detail, that the mass signal at is indeed localized to the Purkinje cell layer. fter the MLDI acquisition, an H&E stained image of the section was acquired and is shown in Figure 3c. Individual Purkinje cells are indicated by arrows on both the molecular and the microscopic images. That the somata are represented by multiple pixels suggests that the spatial resolution is higher than 30 µm. The images in Figure 4 show expanded regions of Figures 3b-c that contains a single Purkinje cell. Here, the molecular image is not interpolated so each square pixel represents data from a single MS spectrum (at 10µm raster width/ spatial resolution). The Purkinje cell soma has a diameter of ~30 µm, and is represented by 3 3 mass spectrometric pixels, clearly demonstrating an actual mass spectrometric pixel size of 10µm. Testis consists of a number of well-defined anatomical structures that span a range of sizes and make it another good model system for evaluating mass spectrometric imaging performance. The main structures are seminiferous tubules which have a diameter ~200 µm. Within each tubular lumen the stage of spermatogenesis determines the internal structure. The interstitial space between tubules can range in size from a few µm up to 40 µm in width. Finally, the tubules are lined on the outside with layer of smooth muscle cells. Whether or not the interstitial space and the muscle layer surrounding the tubules can be clearly resolved is therefore a good test for evaluating spatial resolution in a mass spectrometric imaging experiment. small region of testis was imaged by MLDI-TOF and the distributions of three mass signals are shown in Figure 5 along with an H&E image of the analysis region taken after the MLDI experiment. The main anatomical structures are visible, especially a layered structure inside the seminiferous tubules highlighted by the ions shown in green and blue. The interstitial space (denoted by the ion in red) is also clearly resolved. MLDI-FTMS imaging FTMS instruments are especially suited for imaging of small molecules such as lipids because of their unsurpassed mass resolution and measurement accuracy. In the case of complex samples such as tissue, there are typically many isobaric compounds at each nominal m/z and a more accurate description of the sample makeup can be obtained when these are well resolved. Moreover, the precise mass measurement often allows an unambiguous determination of the molecular formulas of the observed compounds. Combining such high MS performance with a high spatial resolution promises to generate datasets rich with information.

Purkinje cells single Purkinje cell C Figure 4: Expanded view of the region highlighted in Fig. 3b, surrounding a single Purkinje cell. : The mass spectrometric image shown without interpolation. Each pixel represents one mass spectrum from a 10 µm area. : H&E image of the same section. The the dimension bar shows the Purkinje cell to have a diameter of 30 µm. Rat testis imaged at 10 µm pixel size with MLDI-TOF Figure 3: n example of a mass signal which is localized to the Purkinje cells. : Wide-field view showing the distinctive cellular layer surrounding the granular layer. : Expanded view of the highlighted region. C: H&E image of the same tissue section. In C individual Purkinje cells are designated with arrows. The corresponding Purkinje cells are annotated with arrows in. 813.61 Da 809.58 Da 801.56 Da Here, we applied MLDI-FTMS imaging analysis to the rat testis sample. Five structurally localized ions are shown in Figure 6 without display interpolation so that every visible square pixel represents one mass spectrum. From the three selected mass signals in Figure 6a we see that a pixel size of 10µm is sufficient to clearly distinguish the layer surrounding the tubules, the interstitial space and the lumen of the tubules. Figure 6b shows the distribution of two mass signals that are only 3 mda apart and exhibit very different distribution in the tissue. One mass signal is detected only from the interstitial space while the other 813.61 is Da detected in the lumen of the tubules. 809.58 Da 801.56 Da Figure 5: : Image which shows localization of three selected mass signals to different structures: seminiferous tubules (in green and blue) and interstitial space (in red). : H&E image of the same section.

The two peaks (as detected from the pixels highlighted in Figure 6b) are shown in Figure 6c. In this broadband (wide m/z range) FTMS measurement the average mass resolving power was approximately 190,000, which is sufficient to generate the image because those signals are also spatially resolved. If these peaks were in the same spectrum the resolution necessary to resolve them at a nominal mass of 808 Da would need to be greater than 300,000 which can be achieved using CSI. The signal of 808.58192 Da is not fully resolved from a lower-intensity, co-localized signal at 808.58554 Da. However: the peaks have sufficient spatial differentiation that 808.58554 does not contribute significant interference to the ion image of mass signal 808.58497 Da. Further, the measurement accuracy of the FTMS measurement allows the direct estimation of the molecular formulas labeled in Figure 6c. The mass signal at 808.58192 Da likely corresponds to the molecular formula [C 44 H 84 NNaO 8 P] + (a calculated mass of 808.582676 Da, a 0.94 ppm deviation from the measured mass). The signal at 808.58192 Da most likely corresponds to the molecular formula [C 46 H 83 NO 8 P] + (a calculated mass of 808.585082 Da, a 0.14 ppm deviation from the measured mass). Conclusion Sample preparation and instrumental parameters compete to be the limiting factor for achieving high spatial resolution in MLDI imaging. Sublimation of matrix offers an ideal dry preparation for MLDI imaging of lipids in which matrix crystal size and analyte migration do not limit high spatial resolution. Using this preparation strategy we were able to readily achieve a spatial resolution of 10µm using standard commercial ultraflextreme, autoflex speed and solarix instruments with the smartbeam II laser. Rat testis imaged at 10 µm pixel size with MLDI-FTMS C Δ = 3.05 mda m/z = 808.58497 [ C ] + 46 H 83 NO 8 P 50 µm m/z = 808.58192 [C 44H ] + 84 NNaO 8 P 758.545 Da, 788.607 Da, 848.547 Da m/z = 808.58554 808.570 808.575 808.580 808.585 808.590 808.595 808.600 m/z 50 µm 808.582 Da, 808.585 Da Figure 6: : Image which shows three peaks localized to: tubule lumen (blue), basal layer (green) and interstitial space (red). : Image of two peaks which have a mass difference of 3 mda differentiated to tubule lumen and interstitial space. C: Mass signals from designated pixels in ) with suggested molecular formulas

ruker Daltonics is continually improving its products and reserves the right to change specifications without notice. ruker Daltonics 01-2013, 1815853 MLDI images of rat cerebellum C 815.7 Da 849.7 Da Reproduced from inside: Figure 2: MLDI images from part of rat cerebellum acquired at 10µm pixel size. : Three selected masses which show cellular localization: the mass signal in green highlights the individual Purkinje cells; the mass signal 815.7 Da in red is found in the cerebellar white matter; and the mass signal 849.7 Da is found in the granular layer. : Two selected mass signals that show strong differentiation, the mass signal at also exhibits spatial differentiation according to intensity range. C: Optical image of the measured cerebellum with measured region shown for context. ll scale bars: 200 µm. References For research use only. Not for use in diagnostic procedures. [1] Puolitaival SM, urnum KE, Cornett DS, Caprioli RM Solvent-free matrix dry-coating for MLDI imaging of phospholipids J m Soc Mass Spectrom. 2008 Jun;19(6):882-6 [2] Chaurand P, Cornett DS, ngel PM, Caprioli RM From whole-body sections down to cellular level, multiscale imaging of phospholipids by MLDI mass spectrometry Mol Cell Proteomics. 2011 Feb;10(2):O110.004259. ruker Daltonik GmbH remen Germany Phone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 sales@bdal.de www.bruker.com ruker Daltonics Inc. illerica, M US Phone +1 (978) 663-3660 Fax +1 (978) 667-5993 ms-sales@bdal.com Fremont, C US Phone +1 (510) 683-4300 Fax +1 (510) 490-6586 ms-sales@bdal.com