Managing the Underfill Process in Transient Thermal Environments



Similar documents
RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Injection molding equipment

CHAPTER 2 INJECTION MOULDING PROCESS

Nordson EFD Solutions: Fluid Positioning & Precision Dispensing in Mobile Device and Wearables Manufacturing

3M Scotch-Weld EPX Two-component structural adhesives and applicator guns

Benefits of Cold Aisle Containment During Cooling Failure

2.810 Manufacturing Processes and Systems Quiz #1 Solutions

Machine bolt shut-off nozzle type BHP pneumatically or hydraulically controlled

ILX Lightwave Corporation

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Fluid Mechanics Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

3M Thermally Conductive Epoxy Adhesive TC-2810

1W High Power Purple LED Technical Data Sheet. Part No.: LL-HP60MUVA

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

MDU SC Connector Termination Procedure

Accelerometer and Gyroscope Design Guidelines

The Fallacies of Injection Molding as compared to MicroMolding. by Scott Herbert Rapidwerks Inc.

Galil MotionCode Solution: Chip Encapsulation Material Fluid Dispensing Machine

Better DSC Isothermal Cure Kinetics Studies Using Power Compensation DSC

Soil Dynamics Prof. Deepankar Choudhury Department of Civil Engineering Indian Institute of Technology, Bombay

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Soldering And Staking OEpic TOSA/ROSA Flex Circuits To PWBs.

A CRITICAL NATIONAL NEED IDEA

PUMP AND MOTOR DIVISION

STERILIZERS, LABORATORY DRYING OVENS

About Coffee and Refractometers Voice Systems Technology, Inc. (VST)

Environment-Laboratory Ambient Conditions

ArtisanLink Staining System is an automated special stains slide

Molded. By July. A chip scale. and Omega. Guidelines. layer on the silicon chip. of mold. aluminum or. Bottom view. Rev. 1.

Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?

Solution heat treatment facility

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

ORGANIC SAMPLE PREPARATION

CONVECTION CURRENTS AND ANOMALOUS BEHAVIOUR OF WATER

Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY

NUCLEAR ENERGY RESEARCH INITIATIVE

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

A Study of Process Variability of the Injection Molding of Plastics Parts Using Statistical Process Control (SPC)

RESPONSE TIME INDEX OF SPRINKLERS

Effects of Tg and CTE on Semiconductor Encapsulants

RESEARCH PROJECTS. For more information about our research projects please contact us at:

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

VISCOSITY OF A LIQUID. To determine the viscosity of a lubricating oil. Time permitting, the temperature variation of viscosity can also be studied.

VJ 6040 UHF Chip Antenna for Mobile Devices

Results of cooling of dies with water mist

Trace Layer Import for Printed Circuit Boards Under Icepak

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Advanced Monolithic Systems

Assessing Measurement System Variation

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

POWER AND VOLTAGE RATING

Thermal Adhesives Ther-O-Bond 1500

Throw Part IV: spin-induced throw

Thermal Load Boards Improve Product Development Process

HL-A-3528H308W-S1-13. Description. Applications. Recommended Soldering. Package Dimensions

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Specification MBT801-S

Natural Convection. Buoyancy force

Machine nozzle with needle shut-off type HP pneumatically or hydraulically controlled

Scholars Research Library

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

6 Design of Gates. 6.1 The Sprue Gate

Polymer Termination. Mechanical Cracking 2. The reason for polymer termination. What is Polymer Termination? 3

DESIGN ANALYSIS FOR COMPONENTS OF PNEUMATIC INJECTION MOULDING MACHINE USING PRO-E

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

INJECTION MOULD DESIGN: MARPLEX PVC RESINS

PP / PE X X X X (X) X PA (X) X

A.Pannirselvam*, M.Ramajayam, V.Gurumani, S.Arulselvan and G.Karthikeyan *(Department of Mechanical Engineering, Annamalai University)

Incubator with mechanical convection

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Characterization of Electronic Materials Using Thermal Analysis

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Accurate Air Flow Measurement in Electronics Cooling

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Development of High-Speed High-Precision Cooling Plate

Investigation into the energy consumption of a data center with a thermosyphon heat exchanger

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

POWER FORUM, BOLOGNA

Part Marking Instructions Chip Resistors

BSP52T1 MEDIUM POWER NPN SILICON SURFACE MOUNT DARLINGTON TRANSISTOR

IRB 2600ID-15/1.85 Simple integration, high performance

3rd Generation SCR System Using Solid Ammonia Storage and Direct Gas Dosing: Expanding the SCR window for RDE

How To Calculate Thermal Resistance On A Pb (Plastipo)

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach

3M Thermally Conductive Adhesive Transfer Tapes

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

PROVE, the next generation registration metrology tool, status report

New Methods of Testing PCB Traces Capacity and Fusing

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

Iterative calculation of the heat transfer coefficient

REPAIR CONCEPT SUPPORTED BY LASER REMOVAL AND INDUCTIVE HEATING

PV-FZ Silicon Wafers for High Efficiency Solar Cells

Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

Transcription:

IMAPS Device Packaging Conference 009 Flip Chip Track Rev 3 Managing the Underfill Process in Transient Thermal Environments Authors: Steven J Adamson, Dan Ashley, William Hassler, Jared Wilburn Asymtek, Carlsbad California. sadamson@asymtek.com Abstract: In the world of microelectronic assembly most process developments are aimed at making smaller components to fit more functions into ever smaller portable devices. This study was designed to look at large device underfill, where the silicon die is over 15mm on a side, and the amount of underfill required is on the order of 30 to 50 mg. The manufacturing process for these large die are pushing throughput requirements to much higher levels than seen on production lines today, bringing new challenges to dispensing underfill. When such large devices are produced at rates over 3000 uph the dispensing tools have to move a lot of material. The sheer volume of material passing through the jet may present problems in heating fluids to the desired process temperatures before dispensing. This impacts the accuracy of shot size because underfill fluids change viscosity with changes in temperature, and for a given cycle, jet the shot volume can change slightly. This in turn impacts material keep-out zones next to the die. Constant temperature of the underfill fluids results in greater repeatability of shot size, aids flow under the die, and improves fluid break off. During this study, it was also observed that the system thermal environment (inside the dispensing machine) had a large impact on the shot weight dispensed. Introduction Underfill materials are normally made from two part epoxies. They are mixed, degassed, packaged into syringes and frozen to -40 deg C for storage. At this temperature the underfill usually has a shelf life of 6 months or greater. There is still a small amount of curing of the two part materials at this temperature, but the reaction rate is very slow. When materials are removed from the -40 deg C storage conditions, they thaw out, and start to react more quickly. Many materials have an 8 hour pot life at room temperature, and this is often specified as a point where the materials viscosity doubles.

Figure 1 is a plot of viscosity over time during a production run using a two part underfill fluid. Essentially the fluid is curing and the viscosity is increasing. Automated dispensing equipment has Mass Flow control systems built into them, which automatically adjust the dispense weight to accommodate the changes in viscosity Weight (mg) 30.00 5.00 0.00 15.00 10.00 5.00 0.00 0:00 0:30 1:00 1:30 Time (min) Viscosity [cps] 35.00 0.000 900 800 700 600 500 400 300 00 Viscosity vs. Time 0:00 0:15 0:30 0:45 1:00 1:15 1:30 1:45 :00 :15 :30 :45 3:00 3:15 3:30 3:45 Time [Minutes] :00 :30 3:00 3:30 4:00 0.050 0.100 0.150 0.00 0.50 0.300 0.350 0.400 0.450 0.500 Fig Flow Rate vs Line Speed Figure 1 Viscosity vs Time (ref 1). Under normally steady state conditions the fluid weight is reduced over time. To compensate for fluid changes the dispense line speed is reduced to obtain the same weight of fluid on the part, when using needle dispensing. With jet dispensing the number of cycles / dots is adjusted to add more fluid and keep the time constant. In figure it can be seen that over time the flow rate of the un-calibrated fluid has Speed (in/s) LCL Uncalibrated line Calibrated line Line Speed UCL decreased, hence the flow rate through a needle tip or jet has to be adjusted to compensate. Using a Mass Flow calibration procedure the dispensed weight of material is kept within the Upper and Lower control limits, as shown by the purple line. While this relationship between time and viscosity is fairly predictable as production rates increase and underfill fluid keep out zones are reduced, variations in fluid volume from other factors can cause changes in the final product that are not acceptable. To understand the problems being experienced, an extensive study was undertaken to determine the factors acting upon a DispenseJet.

Variable Analysis Heat can quickly change the viscosity of an underfill fluid. Figure 3 shows the measured relationship of viscosity verses fluid temperature for four common underfill materials. It is interesting to note that even the underfill C halves in viscosity over the focused temperature range of 50 to 70 deg C. Therefore any changes in underfill fluid temperatures can be critical to the process. Focused Viscosity vs Temperature 5 0 Viscosity Poise 15 10 5 y = 198.14ē R = 0.9978 y = 484.75ē 0.064x R = 0.8756 0.0579x y = 51. 183 - R = 0.906 e 0.0444x Underfill A Underfill B Underfill C Underfill D Expon. (Underfill B) Expon. (Underfill A) Expon. (Underfill D) Expon. (Underfill C) 0.051x y = 56. 797ē R = 0.986 0 50 5 54 56 58 60 6 64 66 68 70 Temperature Deg. C For this study a six factor, two level screening, Design of Experiment (DOE) was conducted with the variables being min and max fluid pressure, needle stroke, on / off times, and a heat exchanger on or not used at 60 deg C. The addition of the heat exchanger allows the fluid to arrive at the dispense nozzle at a predetermined temperature. Figure 4 shows the jet used for these tests. The heat exchanger is placed in the fluid feed line close to the nozzle. Fluid arrives at the temperature controlled nozzle at a predetermined temperature. Fig 4 Dispense Jet with Heat Exchanger

Typically in jet dispensing systems, some type of temperature control is built into the dispense nozzle. In this case, active heating and cooling is available at the dispense nozzle, to control the fluid temperature within plus or minus one degree centigrade. At very high fluid flow rates the concern is that the fluid does not reach the desired temperature before being dispensed. Hence the reason for a Heat Exchanger built into the fluid path immediately before the jet nozzle. Figure 5 Actual vs Predicted Shot Weight A model was developed to look at the impact of the jets variable factors verses shot weight. Figure 5 shows the result of the model verses dispense or shot weight. The model shows that there is a greater than 90% confidence level that the model can accurately predict shot weight based on known factors of the DispenseJet s features. Figure 6 shows the results from the model in a Pareto chart of the features of a jet that can be varied to change the shot weight and the set points used for the test. The chart shows the variables listed in order of magnitude of the affect. It can be seen that the largest effect on shot weight is the temperature of the fluid, followed by fluid pressure, and on time, with the presence of a heat exchanger in the top four shot weight influencing factors. Figure 6 Pareto of Jet Variable Properties

Experimental Data A series of dispense test were run using identical conditions with a focus on shot weight of fluid and the heat exchanger. The Dispensing system internal temperature was measured at approximately 43 deg C after a heat soak period of one hour. A 6oz fluid cartridge was allowed to come to room temperature over two hours prior to loading into the system. The test was designed to run over, eight hours, with a target shot weight of 40 mg, with an upper specification limit of 44mg, and a lower specification limit of 36mg. The heat exchanger and the nozzle temperature were set at 60 degrees centigrade when powered. Weight sampling was set for every 30 minutes using 10 glass slides, with the first sampling set for time zero. Each test slide would receive 44 dots of underfill, and this was dispensed in.5 seconds with a wait time between slides of 4 seconds. When not dispensing on test slides, the jet would dispense on an FR4 substrate, using a simulated underfill pattern motion. Prior to starting the test the jet was purged for 30 seconds. Before dispensing on the test slides a short 30 second purge was run. Prior to each slide a 0.5 second purge was run to ensure nozzle cleanliness. Weight in mg Figure 7 shows one of the test plots for a system with a jet that has a heat exchanger present (Blue), and one with the exchanger removed (Purple line). It can be seen that at the start of both tests, the volume of fluid increases slightly. Figure 7 Heat Exchanger Test This was due to the fluid sitting in the jet being heated, after the first few shots cooler fluid enters the jet and in both test results drop towards the lower specification limit, where it is now in a controlled dispensing regime. The small raise and fall (saw tooth) nature of booth traces are a result of the system s impingement (forced air) heaters controlling the temperature of the substrates to 130 deg C. These are approximately 5mm below the jet nozzle with a substrate of FR4 or a glass slide between the Jet and nozzle.

When the jet was run without the heat exchanger (see the purple line), on three occasions the flow rate through the jet increased over several hours approaching the upper control limit of 40 mg and then dropped back to the lower control limit of 36 mg. These types of changes were not seen when the heat exchanger was present. Unfortunately the instrumentation at this time cannot explain these anomalies. Which suggests that a factor in the experiment was not accounted for or we have an interaction of more than one variable. It has been observed that simply opening the door on the dispensing system can have a similar effect to what is seen here, although usually of a shorter duration. Although the changes in shot weight in figure 7 are taking place over several hours what is interesting is that the heat exchanger appears to even out these transient changes and provide a consistent thermal environment, and therefore a consistent shot weight of underfill fluid. The original model for this work focused on the jet. However from this testing it was realized that the whole system needs to be modeled to fully understand all interactions affecting the dispensing process. Summary At the beginning of this testing, it was believed that large volumes of underfill fluids flowing at high rates in production may not be heated to desired operating process set points, prior to being dispensed. This would change the weight of underfill fluid being dispensed. The model predicted that fluid temperature has a large impact on shot weight. Unfortunately, the model was only based on the Jet dispensing head and did not include the total system. During these tests it was also found small shot weights could be affected by the ambient temperature changes. This is an ongoing development program. I is clear from the laboratory test data and results from field testing that a consistent fluid temperature is critical to controlling the underfill dispensing process. By adding a temperature controlled heat exchanger to the fluid input line, and tightly coupling this with the jet nozzle temperature controller, it was demonstrated that a precise controlled dispense was obtained even when multiple variables were changing in the system environment. Reference: 1) Use of Closed-Loop Process Controls in Dispensing - J. Klocke (Circuits Assembly Magazine, January 006)