MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION



Similar documents
Embedded & Industrial PCs International Products and Configurations INDEX

Chapter 5 Cubix XP4 Blade Server

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

TrueAlarm Fire Alarm Systems

Series Six Plus Programmable Controller

Electronic Control Devices The European Product Catalogue 2007

UniOP epad33 and epad33t

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

How To Use A Tpc-0T (Tpc) With A Touch Screen (Tpt) And Power Button (Tpl) For A Long Time (Tnt) (Tpp) And A Long Distance (Tft) (

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Display units With alphanumeric screen

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

HP Server Console Switch with Virtual Media Overview

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Rugged and open to your applications

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs

QuickSpecs. HP IP Console Switch with Virtual Media Overview

1.44 kw Programmable DC Power Supplies XLN Series

Light Industrial Panel PC

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Technical Product Specifications Dell Dimension 2400 Created by: Scott Puckett

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

DCS Data and communication server

Cisco MCS 7825-H2 Unified CallManager Appliance

Model #: SMART2200CRMXL

DMS-10101, Computer Equipment

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Touch Panel Computers

NGSS Data Consolidator (DC)

Panel PC SIMATIC HMI IPC577C

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Solid as a Rock etop 300/400

QuickSpecs. Models HP Server Console Switches

Foxboro Evo Process Automation System

Views. Specifications

IOVU-571N ARM-based Panel PC

A-317. Mobile Data Terminal. Android Platform Datasheet

Cisco 7816-I5 Media Convergence Server

Views. Specifications

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

SIMATIC HMI IPC 477C 1/5. Copyright Siemens AG 2013

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

I/A Series HARDWARE Product Specifications

Features Rich Expansion. Specifications Dimensions Optional Kit. Packing List Ordering Information Optional Modules

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Industrial Bar Code Scanners

QuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview

3500/22M Transient Data Interface

Cisco MCS 7816-I3 Unified Communications Manager Appliance

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook


85MIV2 / 85MIV2-L -- Components Locations

Rack Mount LCD KVM Assembly Installer/User Guide

Electronic Control Devices The European Product Catalogue 2007

DUKANE Intelligent Assembly Solutions

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting

40.3. Control Relays and Timers

New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price

2100 POS System User Guide

SMART Board interactive flat panel with appliance Model 8055ie-SMP

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

Industrial Bar Code Scanners

NEC USB PortBar with the Driver Installation Diskette

Dell Latitude E6320. Setup and Features Information. About Warnings. Front and Back View

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

QuickSpecs. Overview. Compaq Evo Notebook N160. What s New. At A Glance

The new 5.7 standard model

NEC USB PortBar with the Driver Installation Diskette

1 Application Description Objective Goals... 3

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

KVM-1501/ KVM-1508/ KVM-1516 KVM-1701/ KVM-1708/ KVM-1716 USER MANUAL

(1.07 inches to 1.37 inches) 376 mm (14.80 inches) 259 mm (10.20 inches)

Inspiron Series. Views. Specifications

Multi-Range Programmable DC Power Supplies 9115 Series

ENGINEERING DOCUMENT. Subject: Hardware Installation Procedure for Ultinet Networking Option.

Machine Tool Control. Besides these TNCs, HEIDENHAIN also supplies controls for other areas of application, such as lathes.

Uninterruptible Power Supply

Touch HMI Devices. The Best Choice for Building/Factory/Machine/Home Automation. Introduction. Features. Touch HMI Devices.

DeltaV Virtualization Hardware

EQUIPMENT SPECIFICATIONS

Quick Connect. quick - simple - efficient.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Compaq Rack Options and Accessories. Monitors and Keyboards

QuickSpecs HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2)

Building A Computer: A Beginners Guide

Upgrading and Servicing Guide

Application Server V240 Platform

Fujitsu PRIMERGY BX600 S3 Blade Server

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Chapter 2 Installation

Specifications 17/17R

Transcription:

MACHINEMATE CNC SYSTEM Hardware SPECIFICATION

Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static Specifications... 7 1.4 Operating Specifications... 7 2 CNC dimensions... 8 2.1 MACHINEMATE ecnc... 8 2.2 MACHINEMATE L2... 10 2.3 MACHINEMATE LW... 11 3 Operator s Station Dimensions... 13 3.1 19 inch Operator s Display Panel... 13 3.2 Vertical Operators station... 14 4 MACHINEMATE Modular IO Dimensions... 16 5 MACHINEMATE Operator s Panel Dimensions... 17 5.1 19 Horizontal Machine Tool Builders Panel... 17 5.2 Slim Line Machine Tool Builders Panel... 18 5.3 19 Horizontal Auxiliary Panel... 19 5.4 Hand Held Operator s Station... 20

1 Introduction / General 1.1 Superior Capability in Technology and Productivity The MACHINEMATE CNC Family provides you with innovative high performance technology to handle the ever-increasing demands of today s automation industry. The modern and fully open CNC architecture using a single powerful CPU gives you leading edge CNC performance and flexibility. This specification provides the general information about the Hardware of the MACHINEMATE CNC family. PAGE 3

1.2 General hardware components The basic models of MACHINEMATE CNC includes following hardware components: CNC control unit with: Motherboard Graphics board Pentium or Celeron processor (its performance depends on the order) SVGA 1 or 2 serial interfaces COM1, COM2 (RS232C) 2 PS/2 interfaces Keyboard and mouse 1 parallel interface LPT1 (Centronics) 2 or 4 USB interfaces Peripheral devices (2 USB ports on the L2 & LW or 4 USB ports on the ecnc). Network interface EtherNet 10/100 interface. Standard on LW. Optional on L2 & ecnc (MM93). Floppy-disk drive 1.44 MB, 3.5" L2 and ecnc are delivered with built-in floppy-disk drive Compact Disk drive MM64 Pen Disk (64Mb) (Optional on ecnc only). 24X CD-R CD-RW Standard on LW The floppy-disk, compact disk drive or pen disk can be used to load or to save: NC-part programs PLC-programs Axis compensation files Machine parameter files Configuration files or 3 rd party software PAGE 4

Hard disk MACHINEMATE CNC Windows 2000 software CNC-axes board CNC operator s panel the hard disk uses an IDE interface. installed on the hard disk; installed on the hard disk; PCI board for analog axes interface. PCI board for Sercos interface (1 or 2 fiber-optic rings) with 24 digital inputs and 16 digital outputs on board. Available in 2 sizes that can be remotely mounted up to 33 Ft (10 meters) from the industrial computer (IPC): 1) 19 X 12.25 inches (483 X 311.5 mm) with full alpha numeric keypad and 12.1 inch TFT flat screen at 800 X 600 pixels. This 12.1 inch TFT size is also available with an optional Touch Screen. A second option in this 19-inch size is a 15-inch Touch Screen TFT. This unit does not have a built in keyboard. 2) Same size panel but with 15 inch TFT flat screen at 800 X 600 pixels. There is no alpha numeric keypad on the panel. Basic switches & pushbuttons M166 & M167 Gray/binary code switches M165 Machine Tool Builder s Panel MTBP Auxiliary Panel Handheld Operator Push buttons for NC-Start, NC-Stop, Jog + and Jog - are available. (Note: These switches are not mounted and wired by MACHINEMATE INC). These switches are used for feedrate override and for spindle speed override. (Note: These switches are not mounted and wired by MACHINEMATE INC). A Machine Tool Builder s Panel (MTBP) is available. This panel includes the basic requirements for a machine tool operator: emergency stop push button, cycle start and stop push buttons, jog plus and minus push buttons, feed rate and spindle speed override pots, and a number of auxiliary push buttons. There are two versions: 19 rack mount and slim line. A MTBP Auxiliary Panel is available. This 19 panel includes a handwheel (or manual pulse generator, MPG) and 16 auxiliary push buttons. The Handheld Operator Station provides a remote station PAGE 5

Station External floppy or CD MMMIO PLC components External Modem Fieldbus Master for the operator. This station includes the basic requirements for manual operations: a handwheel (or manual pulse generator, MPG), an axis select rotary switch, a feed rate multiplier rotary switch, an emergency stop push button, and two push buttons (typically used for the axis jogging). An external floppy drive or CD reader or CD read/write can easily be added utilizing the USB ports. The MMMIO (MACHINEMATE Modular Input Output) system is the hardware component system for the PLC. Available are digital and analog input and output modules. Each interface module is plugged into a module box and each module box can carry two interface modules. Stopping brackets and a termination plug are needed. The connection to the MACHINEMATE is done via the high speed Superbus using cables that are available in different lengths. An external USB Data Modem is standard on the ecnc. It is optional on the L2. An optional Fieldbus master is available. The supported fieldbus technologies are Interbus (MM91), Profibus slave (MM92), Profibus master (MM97), Can-bus (MM98), DeviceNet (MM99). PAGE 6

1.3 Static Specifications Temperature: -4 F (-20 C) to +140 F (+60 C) Maximum humidity: 80%, (non-condensing) Maximum permitted acceleration: 4.0 g Weight: o L2 IPC 18.5 lb (8.4 kg) o ecnc IPC 24.5 lb (11.1 kg) o LW IPC 15 lb (6.8 kg) o 19 operators display unit with 12.1 TFT 11.0 lb (5.0 kg) o 19 operators display unit with 15 TFT 16.0 lb (7.3 kg) o 11.4 slim line operators display unit and keypad 8.0 lb (4.0 kg) 1.4 Operating Specifications Temperature: 50 F (10 C) to +113 F (+45 C) Maximum humidity: 80%, (non-condensing) Maximum permitted acceleration: 3.5 g Space Requirements: For installation - a free space of 4 (100 mm) is required for all surfaces which have connectors or fans. Power Requirements: 115-240 V AC / 50-60 Hz Maximum power required: 250 VA Test conditions: All controllers are subject to a run-in test of 48 hours in cycles of 50 to 113 F. Protection: Operator s panel IP 65 PAGE 7

2 CNC dimensions 2.1 MACHINEMATE ecnc Front view M205 ecnc with 12.1 TFT 19 rack-mount front panel (see 3.1) M215 ecnc with 15 TFT 19 rack-mount front panel (see 3.1) M245 ecnc with no front panel Each ecnc model is configured for either analog (4 servos) or SERCOS (8 servos). PAGE 8

Top view PAGE 9

2.2 MACHINEMATE L2 Front view PAGE 10

M203 analog L2 with 12.1 TFT 19 rack mount front panel (see 3.1) M210 SERCOS L2 with 12.1 TFT 19 rack mount front panel (see 3.1) M211 analog L2 with 15 TFT 19 rack mount front panel (see 3.1) M213 SERCOS L2 with 15 TFT 19 rack mount front panel (see 3.1) M241 analog L2 with no front panel M242 SERCOS L2 with no front panel Each analog L2 model is configured for 4 servos. Each SERCOS L2 model is configured for 8 servos. 2.3 MACHINEMATE LW Front view M222 LW with 12.1 TFT 19 rack-mount front panel (see 3.1) M223 LW with 15 TFT 19 rack-mount front panel (see 3.1) M227 LW with no front panel Each LW model is configured for 4 analog servos. PAGE 11

Allow 1.2 / 30mm for air flow.270 6.8.590 15.0 12.6 320 2.25 57.0 Top.189 4.8 Slot X 1.18 30.0 2.05 52.0 10.0 -- 254 12.5 317.5 2.05 52.0 11.85 301.0 2.05 52.0 Front / Connector Side Allow 1.2 / 30mm for air flow 13.156 334 Top view PAGE 12

3 Operator s Station Dimensions 3.1 19 inch Operator s Display Panel.157 ----- 4.0 Panel Thickness 2.0 ----- 50.8 Panel Depth.56 ----- 15.0.34 ----- 8.5.26 ----- 6.6 12.25 ----- 311.5 TFT Display Keypad.626 ----- 15.9 9.25 ----- 235.0 1.5 ----- 38.1 Panel Cutout 18.32 / 465.0 19.0 / 483.0 19 Operator s display dimensions These dimensions apply to all 19 rack-mount display types. 19 with 12.1 TFT Screen with keypad available in these CNC models: M203 (L2 analog), M205 (ecnc), M210 (L2 SERCOS), M222 (LW) 19 with 15 TFT Screen (no membrane keypad) available in these CNC models: M211 (L2 analog), M213 (L2 SERCOS), M215 (ecnc), M223 (LW) Front panel requires SVGA and keyboard cables. Different lengths are available: M232 (2.5-meter SVGA cable for ecnc,l2,lw with 15 ), M233 (10-meter SVGA cable for ecnc,l2,lw with 15 ), M234 (2.5-meter SVGA/keyboard set for L2 with 12.1 ), M235 (10- meter SVGA/keyboard set for L2 with 12.1 ), M236 (0.6-meter SVGA/keyboard set for ecnc mounted directly on panel), M237 (2.5-meter SVGA/keyboard set for ecnc,lw with 12.1 ), M238 (10-meter SVGA/keyboard set for ecnc,lw with 12.1 ) PAGE 13

3.2 Vertical Operators station 17 15 TFT with touch 20.187 MM Machine Tool Builders Panel MM-01V2 - Hand wheel + Vertical Operators Station Dimensions M267 - Vertical Operators Station includes 15 TFT with touch screen, Slim Line MTBP (see Section 5.2) & 24V IO Handwheel. Requires SVGA cable. 2.5 and 10-meter lengths are available: M232 (2.5-meter for ecnc,l2,lw), M233 (10-meter for ecnc,l2,lw) PAGE 14

5.533 140.54 5.533 140.54 5.533 140.54 Panel Thickness =.157/4.0 Aluminum.12 3.0.20 5.09.20 5.09.177 4.5 Corner Detail Panel Cutout Vertical Operators Station Detail Dimensions PAGE 15

4 MACHINEMATE Modular IO Dimensions Modular IO Dimensions MM72 16RO module - 16 relay outputs (all N.O. contacts) MM74 Connector Kit for 16RO module MM76 Box for two modules (box is shown above) MM77 2416 module 24 inputs, 16 outputs (all 24VDC) MM80 Connector Kit for 2416 module MM79 Cover for unused slot in the box M148 4AD4DA module 4 A/D inputs, 4 D/A outputs (all +/- 10V analog) M183 Connector Kit for 4AD4DA module M149 4ENC4A module 4 encoder inputs, 4 D/A outputs, 4 A/D inputs M181 Connector Kit for 4ENC4A module M329 Termination Plug (Required on the last module) M184 DIN Rail Anchor (Set of 2) Cable between IPC and IO box is available in different lengths. MM82 (2-meter), MM85 (5-meter), MM86 (10-meter), MM87 (20-meter), MM88 (35-meter) PAGE 16

5 MACHINEMATE Operator s Panel Dimensions 5.1 19 Horizontal Machine Tool Builders Panel Horizontal Machine Tool Builders Panel M301 Above panel with 2-meter cable M319 Above panel with no cable M360 Above panel with 5-meter cable 50-Pin D-shell female connector with flying lead cable can be used on any of these machine tool panels (this page and on the next two pages. M387 DB50-female with 1-meter cable flying leads M374 DB50-female with 5-meter cable flying leads M373 DB50-female with 10-meter cable flying leads M372 DB50-female with 20-meter cable flying leads PAGE 17

5.2 Slim Line Machine Tool Builders Panel Slim Line Machine Tool Builders Panel M307 Above panel with 2-meter cable M309 Above panel with no cable M361 Above panel with 5-meter cable PAGE 18

5.3 19 Horizontal Auxiliary Panel Auxiliary Machine Tool Builders Panel M293 Above panel with 24V digital MPG and with 2-meter cable M295 Above panel with 5V TTL (encoder compatible) MPG and with 2-meter cable M362 Above panel with 5V TTL (encoder compatible) MPG and with 5-meter cable M363 Above panel with 24V digital MPG and with 5-meter cable PAGE 19

5.4 Hand Held Operator s Station M300 Hand held MPG 24V I/O Handwheel w 4.26 coil cord (21 extended) M316 Hand held MPG 5V TTL Handwheel w 4.26 coil cord (21 extended) M336 Hand held MPG 24V I/O Handwheel w 5.9 coil cord (34 extended) M337 Hand held MPG 5V TTL Handwheel w 5.9 coil cord (34 extended) PAGE 20