STC 3S012-020-A Series Solenoid Valves



Similar documents
STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Advantium 2 Plus Alarm

3/2-way Solenoid Valve, direct-acting, NC or NO

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Solenoid valves 2/2-way direct-operated Type EV210A

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Assisted lift operated 2/2-way solenoid valves Type EV250B

4 Posiflow Proportional Solenoid Valves

System 8. ü ( System 8

Installation and Operation Guide for PD5100 Automatic Transfer Switch

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Self Purging Liquid Trap (SPLT ) User s Manual

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

3 Port Solenoid Valve

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

INSTANT HOT WATER RECIRCULATING SYSTEM

PALLET JACK TON

MAC FAUCETS. Owner s Manual. Models: FA444

Installation and Maintenance Instructions

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

MP-4V Heavy Duty Riveter / 39048

2/2 and 3/2 Way Size 6 Seat Valves

, User s Manual

Stainless Steel Single and Dual Circulation Kits

! WARNING. Before using product, read and understand instructions.

M A N U A L

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Retractable Screen. Replacement Screen Instructions

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

Installation, Maintenance, & Repair Series 4000B/LF4000B

Single Station Remote Alarm

Installation Instructions

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Installation and Operation Guide PD4600 Series Converter Replacement

81000 Series Aluminum Gate Valve Installation and Repair Manual

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ECM-D70T / ECM-D70T1.5

Installation Instructions / Warranty

About this Manual. Support for Your Product

INSTALLATION INSTRUCTIONS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

All in One Activity Walker Instruction Manual

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

In-Tank Fuel Pump Installation Instructions (Read Carefully Before Starting Project)

el-720 Carbon Dioxide Gas Leak Detector User s Guide

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Park 250 Brushless Outrunner Instructions

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

PNEUMATIC PLANISHING HAMMER

Valves. Sub-Base Mounted Valves to ISO 5599/2

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Leak Detection System

SOLENOID VALVES AND PNEUMATIC VALVES

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Mini-led spotlight with magnetic base

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

DUST COLLECTOR 70 GALLON, 2 HP

Toroidal Conductivity Sensor

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Oil and Coolant Circulating Heating System. Model - OCSM

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

Single sub-base valve

Structural Holding System

Electric Water Heater

2015 PRICE LIST. PRICING EFFECTIVE JULY 06, Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

SAVARD PLUMBING COMPANY

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

AIRCRAFT FUEL PUMP & PARTS PRICE LIST

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Transcription:

STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way, Universal Valve that can be used as: 1. Normally Closed (NC) or 2. Normally Open (NO) or 3. Diverter Valve (divert one supply to two outlets) Direct Acting, Response Time <20 msec. Orifice, Cv 1.2mm, C v =0.05 2.0mm, C v =0.20 Operating Pressure Normally Closed: Vacuum to 60 PSI Normally Open & Diverter: Vacuum to 150 PSI Normally Closed: Vacuum to 30 PSI Normally Open & Diverter: Vacuum to 100 PSI Operating Temperature Body Materials Seal Materials Coil Duty Voltage Voltage Tolerance NBR Seal:14 to 176 F (-10 to 80 C); Option: Viton Seal: 5 to 248 F (-15 to 120 C) Stainless Steel NBR, Option: Viton H Class, IP65, 100% ED (Continuous Duty) Options: 12, 24 VDC; 24,110/120, 220/240 VAC (50/60Hz) ±10% of Specified voltage Coil Power 3 to 6.5W Electrical Connections Installation Service DIN No Orientation Requirement Air, Liquid, Oil, Water S T C TM 1

3S012-020-A Series Solenoid Valve Components ELECTRICAL CONNECTION DIN 43650B (PG9) STAINLESS STEEL NUT STAINLESS STEEL WASHER PLASTIC ENCAPSUALTED COIL STAINLESS STEEL ARMATURE TUBE STAINLESS STEEL SPRING 430F STAINLESS STEEL PLUNGER O-RING STAINLESS STEEL VALVE BODY 2

Installation and Operation: To connect the valve Inlet and Outlet: Connect the inlet and outlet in the direction of the arrow marked on the valve. To install coil: Put the coil onto the armature tube of the valve. Put the lock-washer and nut onto the armature tube. Hand tighten the nut, then use a wrench to tighten the nut to a quarter turn; do not over-tighten the nut, it may cause the armature tube to fail pre-maturely. To connect DIN coil: 1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil. 2. From the screw opening, push the terminal block out from the plastic housing. 3. Note the 1, 2 and ground markings on underside of DIN enclosure. 4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative. 5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect 6. Do not energize the coil without installing it onto the valve, it will burn the coil and create fire hazards. Safety Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil. The coil temperature may become hot after being energized for extended periods, but it is normal. Do not energize the coil without installing it onto the valve or connect the coil to a wrong voltage, as it may overheat and damage the coil; although the coil is made of flame retarded material, misuse of the coil in this manner could create fire hazards and generate smoke or burning odor which indicates excessive coil temperature and should disconnect the power to the coil immediately. OFF ON E E A P A P CONNECTION OF PORT NORMALLY OPEN/DIVERTER : A = SUPPLY E = OUTPUT 1 P = OUTPUT 2 NORMALLY CLOSED: P = SUPPLY A = OUTPUT E = EXHAUST ARROW ON BOTTOM OF VALVE BODY ARROW ON BOTTOM OF VALVE BODY 3

DIMENSIONS (MM) MODEL: 3S012-020-1/4A E A P 2-M5(10DP) OFF ON CONFIGURATION OF PORT CONNECTIONS FOR 1. NORMALLY CLOSED: P = SUPPLY A = OUTPUT E = EXHAUST 2. NORMALLY OPEN: E= SUPPLY A = OUTPUT P = EXHAUST 3. DIVERTER VALVE: A= SUPPLY E= OUTPUT 1 (NO) P= OUTPUT 2 (NC) 4

DIMENSIONS (MM) MODEL: 3S012-020-1/8A E A P 2-M5(10DP) OFF ON 5

Direct Acting Valves Models 2H012, 2P025, 2S012-050, 2V025-035, 2W010-040, 3S012-035 Warning: Do NOT over tighten the nut holding the coil to the armature tube. Over tightening may result in damage to the welded joint. Attaching a Coil to a Valve: 1. After wiring the coil, fit the coil assembly over the armature tube. Ensure that the threads of the tube are accessible. 2. Fit the spring or lock washer over the assembly. o For spring washers, the concave side should be oriented toward the coil. 3. Tighten the nut over the washer by hand. o For spring washers, tighten the nut further until the spring coil is almost completely flat. o For lock washers, tighten the nut another quarter turn. Installation Procedure: 1. Connect the default outlet to the connector indicated by an arrow (2P025, 2W040) or the number 1 (2S050). The default outlet on model 2V is the farther port from the armature tube. 2. Connect the default inlet to the remaining connector. Maintenance and Troubleshooting Notes: After an extended period of operation, if you do not hear a clicking sound when the valve is operational, and the wiring is correct, the coil may be burned out and must be replaced. This commonly occurs when input voltages are higher than the coil s specifications. Using valves at low temperature may have small leak when first activated. To fix this, cycle the valve at the highest operating pres ure available until there is no leak, this will create a proper mating surface between the seal and the valve orifice seat. Procedure: 1. Remove any coils attached to the valve. 2. Unscrew the holding plate (for models 2P025 and 2V025) and the armature tube and remove it from the valve body. The plunger and spring are not fastened to the tube and will fall out. 3. Check for any debris that may have collected on the plunger and the hole in the center of the valve. 4. Place the spring back in the plunger, and insert the plunger back into the armature tube. 5. Screw the armature tube and holding plate back into the valve. Reference Figures: Figure 1: [left]: 2P025 [center left] 2V025 [center right] 2S050 [right] 2W040. 2H012 Figure 2: Model 2P025, 2S025-050 and 2W040 indicator arrows are on the valve body. Figure 3: Numbering shown on model 2S050, above the connectors. 6

7

Catalog No.: PUB13C-3S012-020-A Terms and Conditions By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as agreed in writing signed by us. We reserve the right to correct typographic errors and reject orders. SHIPMENTS: All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 94303, USA. Most orders are shipped via UPS Standard Ground unless instructions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping. RETURN OF MERCHANDISE: No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully prepaid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error. Shortages & Mis-Shipments: Any shortages or mis-shipment must be reported within 15 days. CANCELLATION POLICY: Blanket order can be canceled 90 days before scheduled ship date. There will be a 10% charge if a blanket order is cancel within 90 days of scheduled ship date, and a 20% charge if cancel within 60 days. Regular order for non-custom parts can be canceled any time before the order is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever comes later.. Remittances should be sent to: Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 94303, USA Credit Card Payments: Visa, MasterCard, Discover, or American Express Accepted International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card. Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account numbers. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER: Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This limited warranty expires one year after delivery to the end-user. STC s entire obligation to the Purchaser for breach of this limited warranty shall be limited to replacement of the defective product or refund of the original purchase price of this product, at STC s option. Purchaser has thirty (30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser. STC s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during handling or storage.. DISCLAIMER OF IMPLIED WARRANTIES: All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular application. Information contained herein may be changed without prior notification. S T C Sizto Tech Corporation 892 Commercial Street Palo Alto, CA 94303 USA Tel: 650-856 8833 Fax: 650-856 8811 Email: Sales@StcValve.com; www.stcvalve.com 8