Mobrey open channel flow measurement systems



Similar documents
Mobrey open channel flow measurement systems

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Mobrey Hydrastep and Hydratect

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

3DLevelScanner II TECHNICAL DATA SHEET

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Rosemount 333 HART Tri-Loop

Digital inductive conductivity transmitter

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

O C M III. Open Channel Flow Monitor

Regards from the Team at Rheology Solutions.

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Software and Display instruments

Rosemount 333 HART Tri-Loop

How To Use A Ds340 (Dsp)

On-line Machine Condition Monitoring [The CMS System]

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Rosemount 1199 Submersible Seal

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

How To Use A Flowmeter

Plastic tube flowmeters Series PT/PS

Compact pressure switch Flameproof enclosure Ex d Model PCA

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Technical Information RIA14

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Centro-Matic Automatic Lubrication Systems System Controls

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

3500/62 Process Variable Monitor

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Wahl C50 Calibrator FEATURES

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.24. Pump Controller 704. Data Sheet

API Marine. BMS Presentation. Ballast Measurement Systems

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Technical Data Sheet. 3DLevelScanner

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Model 3051 Pressure Transmitter with HART Protocol

USB-500 Series Low-Cost Data Loggers and Accessories

3500/93 System Display

USB-500/600 Series Low-Cost Data Loggers and Accessories

Microcor Wireless Transmitter (MWT)

FIREDEX Conventional Fire Panels

MJK 713 Open Channel Flowmeter

NETWORK ENABLED EQUIPMENT MONITOR

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Current Monitoring Kit QUICK START GUIDE

Temperature & Humidity SMS Alert Controller

NEW. EVEN MORE data acquisition and test stand automation

COMBIMASS. Technical Data COMBIMASS eco-bio +

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Rosemount 751 Field Signal Indicator

S-series Mass Connection Solutions

Current Monitoring Kit

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Linear Luminaire with LED Series EXLUX 6402/2

Thermal Mass Flow Meter (Series MST)

Open channel & partially filled pipe Ultrasonic flow meters

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

SITRANS F flowmeters SITRANS F M

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

TrueAlarm Fire Alarm Systems

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Incubator with mechanical convection

Series 510 Submersible Level Transmitters

Inductive sensor NI10-M18-Y1X-H1141

TMS TANK MANAGEMENT SYSTEM

TEIP11 I/P signal converter for standard signals. Measurement made easy

ALARMLINE ANALOGUE Linear Heat Detection System

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Product Specification instalert Rapid Messenger Variable Message Sign

Micro Motion 3098 Gas Specific Gravity Meter

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Triple Waveband Infra-Red Flame Detection

Material test chamber with mechanical convection

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Multi-Range Programmable DC Power Supplies 9115 Series

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Electronic Control Devices The European Product Catalogue 2007

Transcription:

Technical specification sheet IP2039 October 2008 Level Mobrey open channel flow measurement systems Comprising: MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey MCU/MSP ultrasonic systems have a long and successful history in open channel flow measurement and logging. The MCU90F is the latest addition to this family and is a dedicated open channel flowmeter and control unit based upon the highly successful MCULOG. A system comprises an MCU90F datalogging control unit and a 4-20mA/HART loop powered MSP900 Series ultrasonic transmitter. May also be used with 9700 hydrostatic transmitter. The MCU90F has an integral programming keypad, eliminating the need for handheld programmers. It communicates digitally with the ultrasonic transmitter to give improved resolution and accuracy, and is available in wall or panel mounting options. The whole system carries an ATEX II (1) G certificate for use in Zone 0 areas, reducing installation and wiring costs. The MCU90F includes many features designed specifically with the requirements of open channel flow and logging in mind, including: Calculates flow in an open channel in accordance with BS3680 Pt. 4, ISO14381/1 and ISO4359 Clear local display of - instantaneous flow - daily totalised flow - cumulative totalised flow On-board logging of up to 7000 flow values On-board logging of up to 365 daily totalised flow values In OCF applications, the level transmitter is mounted upstream of the channel restriction or obstruction in accordance with the recommended standards. These standards also define the relationship between the liquid level at that point and the flow through the channel. The popular V-notch weir 5/2 and Venturi flume 3/2 (see overleaf) flow laws which have been used for many years are pre-programmed in the MCU90F control unit, along with other popular flow laws. Where flow measurement has to be in accordance with BS3680 or the Environmental Agency requirements (EA consented flows), the MCU90F has a 20 point look-up table which can be programmed with a dedicated stage discharge curve for the flow structure. If the user does not have the curve available, we offer to calculate the curve for certain structures based on dimensional and flow data provided by the user. A data sheet is produced detailing all of the MCU90F parameters and their values which require programming, together with a projection of the uncertainty for the specific application. Structures for which discharge curves can be provided include:- V-Notch Venturi flumes: - Rectangular - Semi-circular - Trapezoidal Triangular profile (Crump) weirs Broad crested weirs Flat V weirs Parshall flumes Manning formula: - Round pipe - Rectangular channel

Operation The flow in an open channel may be derived by measuring the liquid level upstream of a weir or flume of a standard design. MCU90F Log system It is a regular requirement that the flow and totalised flow be logged for download at a later date. The MCU90F has an on-board logger which can log up to 7000 samples at user definable intervals. In the event of flow exceeding a limit value, fast logging is automatically triggered until the flow reverts to normal. In addition, 365 midnight totalised flow values are also logged along with the maximum instantaneous flow during each 24 hour period. All data is real time stamped and stored for download via an RS232 connection on the control unit. Data can be collected using a portable PC, and is easily stored and manipulated using the Mobrey LogView windows software. Functionality The MCU90F control relays may be allocated as flow rate alarms or may be selected to operate as a pulse output to an external totaliser. There is also the facility to allocate a relay as a low- flow cut off so that totalisation errors are avoided in very low flow conditions. The current output is proportional to instantaneous flow rate and is used for remote monitoring, telemetry or local recorders. Alternatively, the user may select the current output to be proportional to a rolling average of flow over a user defined averaging period. The system will totalise flow and show both instantaneous flow and totalised flow on the display, in different units of measurement if required. Up to 365 daily flow totals are stored and may be recalled at any time. There is also the facility to connect up to two digital (voltage free contact) inputs to the system which may be used to inhibit measurement or force alarms or other routines to start upon external signals. Venturi flume Typical 3/2 power law V notch weir Typical 5/2 power law MCU90FW wall mount MCU90FP panel mount Features summary 240V, 110V ac or 24V dc models Clear back-lit display of instantaneous and logged data Five field adjustable control relays 4-20mA Isolated output proportional to instantaneous or averaged flow (rolling average) 7000 Event logging 365 Daily total flow logging On screen display and recall of logged data ATEX IS output for field transmitter - no external barriers required Operates with 4-20mA or HART loop powered transmitters MCU90FW Series wall mount control units Housed in a tough polycarbonate enclosure, the control unit can be mounted either inside or outside. Easy to use keypad and HMI - easy set up. Built-in programming wizards make det-up and commissioning simple and fast, guiding the user through data entry in easy steps. All wiring terminals and mains selector switch for AC model are accessed by removing the lower terminal box lid, leaving the main electronics compartment undisturbed. The enclosure is pre-drilled with 5 cable entries (M20 / ¾") and glands and blanking plugs are supplied reducing installation time and cost. MCU90FP Series panel mount control units All of the MCU functionality is available in this small panel mounting format. Extending just 165mm / 6.5" into the panel, connection is made to two part terminal blocks on the rear of the unit.

Mobrey LOG-VIEW Communication software for use with Mobrey datalogger control unit Description Mobrey LOG-VIEW is a Windows based package for use on stand-alone PCs. Data is downloaded from the Mobrey MCU90F and the LOG-VIEW software will automatically add new data to data already stored, concatonating data in the correct sequence. Mobrey LOG-VIEW is designed to operate on portable or desktop PCs provided there is 1MB hard disc space available. It is suitable for use on all Windows operating systems up to and including Windows XP. Data collection can be direct to a portable PC (all leads supplied), or collected via a Mobrey Hand Held Communicator and downloaded back at base. PC based software Simple collection & clear display of logged data All connecting leads supplied Transfer of logged data Up to 100m (325ft) 2 core screened cable Data collection options Data Display Tabular listing of samples, showing date, time, actual flow, totalised flow and any out-of-limits alarms Display by day, week, month or year Allows search for maximum and minimum flows Allows search for data on any specified day at any time Display of data as a graph of flow against time Time period may be specified i.e. daily, weekly, monthly Totalised flow as a bar graph may be displayed Open channel flow MCU Flowlog Direct link to PC for use with LOG-VIEW

Dimensions Mounting bracket supplied 1 Hole 13 (½") G1 Thread or 1" NPT 60 (2.36") 228 (10") 75 (2.95") 62 (2.44") Datalogging control unit: wall mount Transducer Datalogging control unit: panel mount Ordering information MCU Mobrey Control Unit 90F Open channel flow WX Wall mounting enclosure PX Panel mounting enclosure -A ATEX certified, mains powered -U UL certified, mains powered -A24 ATEX certified, 24V dc powered -U24 FM certified (pending), 24V dc t t t MCU 90F WX -A Typical model number MSP Mobrey ultrasonic level transmitter 900 UPVC construction, 12m (39ft) operating range SH Factory sealed transmitter, HART communications -A ATEX/CSA certified I.S. (Zone 0) -U FM certified /3 Fitted with 3m (10ft) two core shielded cable /20 Fitted with 20m (65ft) two core shielded cable /50 Fitted with 50m (163ft)two core shielded cable t t t t MSP 900 SH -A /20 Typical model number

Technical specification: Control unit Electrical Supply and power consumption Current input Trigger inputs Current output Relays Cable entry Cable connection ac 98V ac - 132V ac, 50/60Hz/18VA max, 198V ac - 254V ac 50/60Hz/18VA max dc 15V dc to 30V dc / 9W max. 4-20mA and/or HART Digital communications (Rev. 5) Supplies 23V from 400Ω source resistance 2 voltage free contact closures 4-20mA isolated into 1 Kohm (12 bit) 5 SPCO, 5A at 240V ac 5 positions pre-drilled. 2 glands and 3 blanking plugs provided Wall mount: Cage clamp terminal blocks in separate terminal compartment Panel mount: 2 part cage clamp terminal blocks at rear Mechanical Material Enclosure and keypad: Polycarbonate Dimensions Wall mount: 213mm wide x 185mm high x 84mm (8.39" x 7.28" x 3.31") deep Panel mount: Cut out 139 wide x 69 (5.47 x 2.72") high. Allow 165mm clearance behind panel Enclosure rating Wall mount: IP65 (NEMA 4) indoor/outdoor Panel mount: IP42 (NEMA 5) indoor mount; IP65 (NEMA 4) Hood kit available Environmental Installation category: 115V: Cat.III, 230V: Cat.II Pollution degree: 2 Altitude: 2000m (6500ft) max. Relative humidity: 100% Temperature -40 C to +55 C. (-40 F to +131 F) Use of an air circulation fan is recommended if 3 or more panel mounting units are installed in the same cabinet Approvals ATEX coding II (1) G [EEx ia] IIC UL Pending Technical specification: Ultrasonic transmitter Range 0.3 to 12m (11.8" to 39ft) Power supply 24V dc 2 wire loop powered Output 4-20mA Digital Communications HART Ambient temperature -40 C to +60 C (-40 F to +140 F) Maximum temperature -40 C to +60 C (-40 F to +140 F) Operating pressure 0bar to +3bar (0psi to 43.5psi) Material of construction UPVC (Stabilised) Rating IP68 (15m) NEMA 6P Cable 2 core screened Cable sheath PVC Cable length 3, 20 or 50m (10ft, 65ft, 163ft) All cables may be shortened or extended on site. Mounting ATEX models: 1" BSPP FM models: 1" NPT mounting Certification ATEX II 1 G EEx ia IIC T6, FM IS CL 1 Zn0, A Ex iaiic, IS CL 1 DIV1 Grp. ABCD

Level MSP900SH Series ultrasonic level transmitters These 24V dc loop powered transmitters are factory sealed and fitted with cable ready to install on aqueous applications. Manufactured from UPVC, the transmitter is designed to give a 4-20mA HART output proportional to liquid level in the channel. Power is supplied by the MCU90F, and the transmitter is easily configured with the application details using the control unit keypad. All communications with the MSP900SH transmitter MCU90F is digital using the HART digital protocol. Site services Rosemount Measurement has built considerable expertise in the area of open channel flow measurement, and offers an onsite service to verify existing flow structures and instrumentation in accordance with BS3680. The service includes a full survey, report, remedial works, final certification and maintenance thereafter if required. Mobrey head verification device To ensure continued accuracy of instrumentation and allow fast on-site calibration checks at any time, the Mobrey head verification device is available. Easily mounted on standard unistrut or similar, the HVD comprises a target on a stainless steel swivel arm, and supports the ultrasonic transmitter at a fixed distance above the target plate. When the instrument is to be checked for accuracy, the target is swung under the head and the simulated flow reading checked against a certified value for that installation. MSP-HVD is easily retro-fitted to most existing OCF installations. For further information about the range of on-site services offered, visit the Mobrey brand pages at www.emersonprocess.com or contact Rosemount Measurement for details. Mobrey HVD order information MSP-HVD MSP-HVD1 Specification sheet IP2039 October 2008 Use with Mobrey MSP900SH style transmitters Use with Mobrey MSP400RH style transmitters Head verification device with MSP900SH style transmitter fitted The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a registered trademark of Rosemount Inc. Mobrey is a registered trademark of Rosemount Measurement Ltd. All other marks are the property of their respective owners. Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale 2014 Rosemount Measurement Ltd. All rights reserved. International: Emerson Process Managemen Rosemount Measurement Ltd. 158 Edinburgh Avenue Slough, Berks., SL1 4UE, UK Tel: +44 (0)1753 756600 Fax: +44 (0)1753 823589 www.emersonprocess.com Americas: Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317, USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 906 8889