GTS PRODUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. Gas-to-Steam Humidification System



Similar documents
GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

GTS Gas-to-Steam Humidification System

HUMIDIFICATION DESIGN CHECKLIST: GETTING IT RIGHT THE FIRST TIME.

"EC" Series Electric Humidifier

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Direct steam injection humidifiers

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

2010 Residential Water Heater Replacement Check List

CRAC Precision climate control units for data centres

Commercial Gas Water Heaters

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Arapahoe County Residential Water Heater Installation and Inspection Guide

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

High efficiency, cast-iron gas boiler

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

NAVIEN AMERICA INC FITCH AVENUE

CE6500 Energy Recovery Ventilator

READ AND SAVE THESE INSTRUCTIONS CRUV. Electric Humidifier. Installation, Operation, and Maintenance Manual

Commercial Gas Water Heaters

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

ECOCIAT. Domestic hot water heat recovery unit

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Air Conditioner Water Heater Model ACWH18

SWIMMING POOL HEAT PUMP

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Factory owners must ensure the boiler is:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

"ES" Series Electric Humidifier

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Commercial Gas Water Heater

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Some Criteria for Choosing a Steam Boiler for a Microbrewery

UDSA - UDSBD unit heater

GenStore Archive Cabinet

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

SIOUX HYBRID WATER HEATER

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

HEAVY DUTY STORAGE GAS

E-gas Instant Gas Water Heaters

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Nirvana. Cycling Refrigerated Dryers

EcoSoft Water Softener. General Installation Guide

PMI-IF-H High Efficiency Gas Heat Units

BB-18 Black Body High Vacuum System Technical Description

Adsorption air dryers ADS 1 215

HUMIDIFICATION SYSTEMS: A COST AND EFFICIENCY COMPARISON

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

STERILIZERS, LABORATORY DRYING OVENS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Commercial Gas Water Heaters

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Chilled Water Precision Air Conditioner For Critical Application

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Commercial Gas Furnace Upflow

Installer s Guide 18-AH39D1-13

This will also provide you with the knowledge to insure long life for your Investment

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Installation and maintenance instructions. Danfoss Vent

HS-901(A) BASIC STEAM HEATING SYSTEMS

Element D Services Heating, Ventilating, and Air Conditioning

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Bring the fresh in. Dedicated Outside Air Systems

Glossary of Heating, Ventilation and Air Conditioning Terms

Cooking at the Speed of light!

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SECTION MORTUARY REFRIGERATORS

COMBIMASS. Technical Data COMBIMASS eco-bio +

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Online Infrared Flue Gas Analyzer Gasboard 3000

Technical Specifications for West Campus Data Center HVAC System

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Climate chamber with illumination

Originators of the Flexible Water Tube design

Dehumidifier D 850E. - Instruction manual version 02

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Ammonia Detection System Codes and Design Specifications

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Transcription:

GTS Gas-to-Steam Humidification System PRODUCT CATALOG Vapor-logic 4 controller with: and LonTalk

Gas has lowest energy operating costs The industry s first and best-selling gas-tosteam (GTS ) humidifier continues to be your best choice for reducing energy costs both consumption and demand charges. $$$$ $$$ $$ $ GAS ELECTRICITY To calculate how much you can save by switching from an electric humidifier to a gas humidifier, use our Energy Savings Calculator at www.dristeem.com/energycalc.jsp Vapor-logic4 Convenient Web-enabled remote access with Vapor-logic4 DRI-STEEM s fourth-generation controller Vapor-logic 4 allows, as standard, humidifier control from a keypad or from a Web interface. This provides the capability to securely set up, view, or adjust humidifier system functions from virtually anywhere and at any time. Connect with Modbus, BACnet, or LonTalk GTS humidifiers with Vapor-logic4 are fully interoperable with Modbus, BACnet, and LonTalk systems. Vapor-logic4 can communicate with building automation systems using Modbus, its native language, or by using optional BACnet or LonTalk. More benefits of the best-selling gas-to-steam humidifier... including new GTS-500 and GTS-700 models through the USB port on the from the keypad or from to. All humidifier components are contained within enclosures no access to all connection points

Proven performance consistent humidity output Application flexibility spaces including sealed combustion Minimal maintenance inspection and servicing minerals from evaporating chamber Built-in safety humidifier operation down burners in a low water condition Next generation control with Vapor-logic4 The heart of any humidification system is its controller. See the next page for the features DRI-STEEM dispersion: Proven and guaranteed competitors don't come close to for more dispersion information. Save even more energy with our High-Efficiency Tube option reduced condensate are also significantly lowered. Brave the cold with our heated/ventilated outdoor enclosure temperatures are under extreme conditions. See more information

Use the Vapor-logic4 keypad or the standard Web interface, shown here, to control your GTS humidification system. Insert a USB flash drive into the Vapor-logic4 board s USB port to perform software updates, or to back up and restore data. Accurate, responsive control Vapor-logic, DRI-STEEM s humidification system controller, has been setting the standard that established the Vapor-logic reputation, plus Web interface, a standard feature, enables remote, simultaneous, secure access from anywhere, at any time. Modbus, BACnet, and LonTalk allow interoperability with multiple building automation systems (BAS). Up-time optimizer keeps humidifiers operating through system faults, as long as safety conditions are met, minimizing production down-time. USB port on Vapor-logic4 allows easy software updates, and data backup and restore capability. PID control provides accurate, responsive, and adjustable relative humidity control. Real-time clock allows time-stamped alarm and message tracking, and accurate drain and flush scheduling. Tank temperature sensor, mounted on the evaporating chamber, allows over-temperature protection, freeze protection, and tank preheating, allowing rapid response to a call for humidity. Auxiliary temperature sensor/transmitter allows temperature compensation control to prevent window condensation, or air temperature monitoring, such as in a duct. Programmable outputs allow remote signaling or device activation, and are easily configured during the setup process. Multiple-humidifier control humidifiers with one controller. Enhanced diagnostics Test outputs function, using the keypad or Web interface to verify component operation Test humidifier function, by simulating demand to validate performance Data collection alarms, and service messages for viewing from the keypad or Web interface Factory commissioning of humidifier and control board guarantees a reliable, fast installation, minimizing field installation each tank before shipping. Preconfigured but easily changed. Just go into the Setup menu to

3 4 2 1 1. When the GTS humidifier is first activated, the fill valve opens and the evaporating chamber fills with water to the operating level. 2. the water in the evaporating chamber boils. The burners then begin to modulate based on demand. The fill valve opens and closes as needed to maintain the operating water level. 3. Steam created in the evaporating chamber flows through vapor hose or piping to the dispersion assembly, where it is discharged into the airstream. 4. The products of combustion are vented out the flue.

2 12 7 3 10 9 1 Low-water cutoff 8 Systems using tap or softened water control each rod. Float rod 4 5 1. Vapor-logic4 controller (keypad and Web interface not shown) Vapor-logic4 controls all humidifier functions as a stand-alone controller or integrated into a Modbus, BACnet, or LonTalk 2. Water level control Tap or softened water systems control water levels electronically a low-water cutoff switch. 3. Redundant water sensor The redundant water sensor provides a safety to the main water level sensor to prevent operation if water is not covering the 4. Water tempering device This factory-installed water-tempering device automatically 6 11

5. Drain keypad or Web interface. To avoid possible stagnant water and microbial growth, the humidifier automatically drains if there is default). 6. Auxiliary drain draining the tank. 7. Water skimmer/overflow port In standard water systems, the water skimmer reduces minerals in the evaporating chamber. Skimming occurs each time the humidifier fills. The skim time duration is user-adjustable. port also functions as an overflow port. 8. Infrared burners Infrared burners provide fast and efficient heating. The burners have no standing pilot, thus saving energy and improving safety 9. Heat exchanger to the water in the evaporating chamber to generate steam. 10. Flue connection 11. Cleanout plate The cleanout plate allows access for easy removal of settled 12. Steam outlet dispersion unit through either vapor hose or piping.

Model Number of burners Maximum steam capacity Input Water usage at maximum capacity** Tank volume Operating weight GTS Shipping weight GTS with outdoor enclosure Operating weight Shipping weight Full load amps* hr gals litres kg kg kg kg GTS-100 1 75 100 700 170 500 1 150 700 170 500 450 1000 455 600 GTS-400 400 117 450 1000 455 600 GTS-500 170 500 147 45 76 1100 500 600 1450 660 4.5 GTS-600 450 600 176 54 76 1100 500 600 1450 660 4.5 GTS-700 4 700 1400 700 1750 1050 475 6.0 4 600 1400 700 1750 1050 475 6.0 Note: feet Altitude meters Input derate % 0 610 0 610 765 4* 6* 4001 4500 10 4501 5000 5001 5500 14 5501 6000 16 6001 6500 6501 7000 7001 7500 Capacity notes the DRI-STEEM Design Guide or our software program, Dri-calc. LP gas All models operate at rated High altitude A d for high altitude derate information. *

Top view Front view Side view G H F C J L 5" E B K A Description GTS-100 GTS-200 GTS-300 GTS-400 GTS-500 GTS-600 GTS-700 GTS-800 inches mm inches mm inches mm inches mm A B 670 1076 C Shroud height 41.00 1040 41.00 1040 41.00 1040 41.00 1040 15.50 14.75 14.00 Flue position E F Flue diameter 5.00 7.00 10.00 G 740 Steam outlet position H J K L

air intake Description Gas supply GTS-100 GTS-200 GTS-300 GTS-400 GTS-500 GTS-600 GTS-700 GTS-800 inches inches inches inches ½ 15 1 1 1¼ 4 100 4 100 4 100 4 100 5 7 10 * 10 10 10 10 Steam outlet Condensate return 1½ (pipe thread or ¾ 40 50 1½ ¾ 40 1½ 4 ¾ 40 100 1½ 4 ¾ 40 100 Notes:

Mounting painted enclosure with integral base. galvanized steel enclosure with integral base and includes heaters and ventilation fans. The outdoor enclosure may also be ordered without the heater package, or with a factory-supplied roof curb. Note:

Heated and ventilated outdoor enclosure DRI-STEEM offers a robust and affordable enclosure for mounting the GTS humidifier outdoors. Independent testing has proven that the GTS installed within this new outdoor enclosure provides error- The GTS humidifier and outdoor enclosure are assembled at the factory. The unit ships complete to the job site, ready for easy-toconnect gas, water, electrical, and steam field connections. The outdoor enclosure has heating and operation in temperatures from 40 F Outdoor enclosure features To ensure complete safety and operation in all climates, the outdoor enclosure has heating and venting systems that ensure humidifier operation in temperatures can also be ordered without the heater package. The outdoor enclosure is ideal for facilities that have limited interior space. The outdoor enclosure ships complete with a GTS unit preinstalled and tested, ready to easily connect to gas, water, steam and electricity. GTS humidifiers and outdoor addition, in-house testing has proven that the GTS and outdoor enclosure provide error-free ignition and reliable operation under Easily removed panels provide access to all internal components. The outdoor enclosure is ruggedly built to completely protect internal components. The enclosure is constructed of heavy-duty galvanized steel and is fully insulated. Serviceable gaskets on access panels ensure a tight seal. and allows easy installation.

Standard steam outlet Optional steam outlet Steam outlet Ventilation fans air intake GTS Ventilation fans air intake GTS Emergency drain Emergency drain Notes: A 14" B C B C Description GTS-100 GTS-200 GTS-300 GTS-400 GTS-500 GTS-600 GTS-700 GTS-800 inches mm inches mm inches mm inches mm A Enclosure height B Enclosure width 660 1067 C Enclosure length 1454 1454 1454 1454

Optional condensate return piping from dispersion Shock arrester recommended to Flue connection or greater than dimension H Gas inlet connection H Notes: maximum discharge water temperature. atmosphere. GTS model number H = Height required to overcome humidifier internal pressure inches mm 41 1041

Optional condensate return Flue connection H Gas inlet connection GTS-DI model number H = Height required to overcome humidifier internal pressure inches mm 41 1041 Notes: and maximum discharge water temperature. atmosphere. directly to tap water. piping for standard water models.

Guaranteed non-wetting distances developed guaranteed steam absorption (non-wetting) distances, accommodate any application. one or two rows of closely-spaced thermal- the airstream. Dry steam Adding humidification to an airstream without creating wetness in the duct system is critical for the maintenance of a healthy environment. Wet areas in ducts are a threat to the health of building occupants since they moisten dust on duct floors, creating ideal breeding grounds for disease-producing microbes. In addition, water accumulating in ducts can drip and cause building damage. Steam exits drip-free through tubelets All DRI-STEEM evaporative dispersion tube units discharge steam through thermal-resin tubelets fitted into dispersion tubes. These driest, through the tube wall, to the duct airstream. In essence, allowing steam to cross over lower-temperature metal without condensing or dripping. Each tubelet contains a calibrated orifice and are essential for drip-free steam dispersion. Condensate management Some condensation is inevitable in steam dispersion, but through careful design condensate can be managed. vaporizes dispersion-generated condensate. Rapid-sorb dispersion units manage velocities to ensure condensate is not pushed out into the air along with steam but drains out the opposite end of the header. Reduce condensate, wasted energy with High-Efficiency Tubes To significantly reduce condensate and wasted energy, use High-Efficiency Tube option

Ultra-sorb Models LV and LH Most versatile of downstream devices Capacity: High-Efficiency Dispersion Tubes option For new and existing Ultra-sorb, Rapid-sorb, single dispersion tube condensate production Ultra-sorb Models LV Ultra-sorb Model LH Ultra-sorb Model LV with High-Efficiency Tubes Rapid-sorb with High-Efficiency Tubes

Rapid-sorb dispersion tube system Multiple tubes, short non-wetting distance Capacity: Rapid-sorb dispersion tube system Single dispersion tube Installation flexibility Capacity: Single dispersion tube Area-type fan Quiet steam dispersion for open spaces Capacity: Area-type fan

G A' Supply header G E E C G F Top view Header Insulated Uninsulated lbs/hr kg/h lbs/hr kg/h Note: * For Model LV, For Model LH, B B' calculation. Notes:. Condensate header H Header Elevation view A E Side view A Unit width A' Face width B Unit height B Face height C Steam inlet diameter D Condensate drain E Header enclosure F Header enclosure G H Condensate header enclosure Note:

Header capacity Header diameter inches 600 4 100 1100 500 5 6 150 H A' E G F C E G Top view Notes:. B B' Elevation view A Supply header G E Side view A Unit width A Face width B Unit height B Face height C Steam inlet diameter D Condensate drain E Header enclosure F Header enclosure G H Condensate header enclosure Note:

A E use hose cuff and clamps B Header outside duct C Escutcheon plate F Header inside duct or AHU Note: Dimension Description Inches (mm) A B C Face width Face height Steam inlet capacity Condensate drain E inside of duct or AHU wall F or AHU wall to end of Note: Tube diameter Insulated (High-Efficiency Tubes) Uninsulated inches DN lbs/hr kg/h lbs/hr kg/h 1½ 40 40 50 77 Note: per panel may need to increase to compensate for or see for the correct calculation.

Without drain or pipe pitch: minimum from top of duct steamgenerating er Single dispersion tube without condensate drain: With drain steamgenerating er or pipe pitch: 6" minimum from Condensate drain. Single dispersion tube with condensate drain: Tube size Insulated (High-Efficiency Tubes) Uninsulated Without drain With drain Without drain With drain inches 1½ 40 65 50 65 44.1 Notes:

60 F (16 C) Maximum steam capacity 30% RH 40% RH 50% RH Rise Spread Throw Rise Spread Throw Rise Spread Throw ft m ft m ft m ft m ft m ft m ft m ft m ft m 50 1.0 0.6 6.0 1.0 0.6 6.0 1.0 6.0 75 4.0 100 45 4.0 4.0 10.0 4.0 4.0 10.0 4.0 5.0 1.5 10.0 150 6.0 5.0 1.5 6.0 5.0 1.5 6.0 5.0 1.5 7.0 7.0 4.0 7.0 14.0 7.0 14.0 7.0 7.0 4.0 7.0 14.0 7.0 14.0 110 15.0 4.6 16.0 16.0 17.0 10.0 10.0 5.5 10.0 10.0 5.5 17.0 10.0 10.0 5.5 10.0 10.0 5.5 70 F (16 C) Maximum steam capacity 30% RH 40% RH 50% RH Rise Spread Throw Rise Spread Throw Rise Spread Throw ft m ft m ft m ft m ft m ft m ft m ft m ft m 50 1.0 1.5 0.5 4.0 1.0 0.6 4.0 1.0 0.6 4.0 75 0.6 0.6 6.0 0.6 6.0 0.6 6.0 100 45 150 4.0 4.0 10.0 4.0 4.0 11.0 4.0 4.0 11.0 5.0 1.5 5.0 1.5 11.0 5.0 1.5 5.0 1.5 5.0 1.5 5.0 1.5 5.0 1.5 5.0 1.5 11.0 5.0 1.5 5.0 1.5 5.0 1.5 5.0 1.5 110 6.0 6.0 6.0 6.0 4.0 6.0 6.0 14.0 7.0 7.0 14.0 7.0 7.0 15.0 4.6 7.0 7.0 16.0 7.0 7.0 14.0 7.0 7.0 15.0 4.6 7.0 7.0 16.0 Notes: Fan specifications: Control: Rotary switch m

Expect quality from the industry leader optional extended warranty. For more information www.dristeem.com sales@dristeem.com For the most recent product information www.dristeem.com DRI-STEEM Corporation European office: Belgium Corporation and are filed for trademark registration in Canada and the European community. for explanation only without intent to infringe. DRI-STEEM conserves resources by designing humidification systems that optimize performance. Systems that perform well save energy and water and, ultimately, cost less to operate and maintain. Save energy airstream heat gain and condensate production. Rapid-sorb steam dispersion panels. disperse unheated micro-fine water particles into airstreams or open spaces. As atomized water droplets evaporate, air temperature drops, reducing the cooling load. This provides significant energy savings when humidifying and cooling simultaneously. Save water and reduces airstream heat gain, energy costs, and boiler chemical use. Available for STS steam-to-steam humidifiers and all pressurized steam applications. Optimize performance DRI-STEEM s most advanced controller, Vapor-logic 4 continuously monitors space conditions to align humidifier output with demand. The result is accurate, responsive control. Your DRI-STEEM representative is: