Administrator s Guide for NETZSCH Remote Access



Similar documents
1. Introduction What is Axis Camera Station? What is Viewer for Axis Camera Station? AXIS Camera Station Service Control 5

Windows 7 Hula POS Server Installation Guide

Immotec Systems, Inc. SQL Server 2005 Installation Document

Setup and configuration for Intelicode. SQL Server Express

1. CONFIGURING REMOTE ACCESS TO SQL SERVER EXPRESS

Remote Desktop Gateway. Accessing a Campus Managed Device (Windows Only) from home.

Install MS SQL Server 2012 Express Edition

Hosted Microsoft Exchange Client Setup & Guide Book

Business mail 1 MS OUTLOOK CONFIGURATION... 2

Case Closed Installation and Setup

Upgrade Guide BES12. Version 12.1

User Guide. Time Warner Cable Business Class Cloud Solutions Control Panel. Hosted Microsoft Exchange 2007 Hosted Microsoft SharePoint 2007

Installation Instruction STATISTICA Enterprise Small Business

PORTLANDDIOCESE.ORG - How to Connect Table of Contents

EMR Link Server Interface Installation

Using TS-ACCESS for Remote Desktop Access

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Installing and Using Citrix to Remotely Access Applications

Installation and Connection Guide to the simulation environment GLOBAL VISION

Toll Free: International:

Business mail 1 MS OUTLOOK RECONFIGURATION DUE TO SYSTEM MIGRATION... 2

Microsoft Office 365 Exchange Online Cloud

Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions

Instructions for Accessing the Hodges University Virtual Lab

PORTLANDDIOCESE.ORG - How to Connect Table of Contents

To set up your Android with Good for Enterprise:

Important Notes for WinConnect Server VS Software Installation:

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Velocity Web Services Client 1.0 Installation Guide and Release Notes

Installation Instruction STATISTICA Enterprise Server

Network DK2 DESkey Installation Guide

This document describes the software upgrade of BRS Appliance from v8.9 to v8.10.

Scan to SMB(PC) Set up Guide

Service & Support. How do you create a communication of RDP with an Industrial Thin Client SIMATIC ITC? Thin Client.

for Networks Installation Guide for the application on a server September 2015 (GUIDE 2) Memory Booster version 1.3-N and later

Dolphin Ocean Server and Dolphin Mobile Client Installation Guide for Android and ios. May 2012

DigiVault Online Backup Manager. Microsoft SQL Server Backup/Restore Guide

HGC SUPERHUB HOSTED EXCHANGE

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Knowledge Base Article: Article 218 Revision 2 How to connect BAI to a Remote SQL Server Database?

Important Notes for WinConnect Server ES Software Installation:

Connecting to the Remote Desktop Service

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Installation Troubleshooting Guide

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Creating client-server setup with multiple clients

IEI emerge and Milestone Systems Network Video Recorder. Setup and Integration Guide. Milestone Version 6.5 and emerge Version 3.

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Defender Token Deployment System Quick Start Guide

Abila Nonprofit Online. Connection Guide

Quick Installation Guide Network Management Card

Technology Services Group Procedures. IH Anywhere guide. 0 P a g e

How To Upgrade Your Microsoft SQL Server for Accounting CS Version

NeoMail Guide. Neotel (Pty) Ltd

To add Citrix XenApp Client Setup for home PC/Office using the 32bit Windows client.

intertrax Suite resource MGR Web

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

Non-ThinManager Components

A-AUTO 50 for Windows Setup Guide

How to setup EW-7438RPn with a Windows computer to extend an existing Wi-Fi network

Backup/Restore Microsoft SQL Server 7.0 / 2000 / 2005 / 2008

Apple Mail Outlook Web Access (OWA) Logging In Changing Passwords Mobile Devices Blackberry...

Two Factor Authentication in SonicOS

Information to configure your Windows 7 office computer is described below.

Use the below instructions to configure your wireless settings to connect to the secure wireless network using Microsoft Windows Vista/7.

Kepware Technologies Remote OPC DA Quick Start Guide (DCOM)

13.1 Backup virtual machines running on VMware ESXi / ESX Server

CHARTER BUSINESS custom hosting faqs 2010 INTERNET. Q. How do I access my ? Q. How do I change or reset a password for an account?

Network Monitoring User Guide Pulse Appliance

Getting Started with Microsoft Outlook with Exchange Online Software from Time Warner Cable Business Class

Avigilon Control Center Gateway User Guide

FaxCore 2007 Application-Database Backup & Restore Guide :: Microsoft SQL 2005 Edition

WorldExtend IronDoor 3.5 Publishing a Terminal Services Application

SJRWMD Cloud-Based Quick-Start Guide

ScanShell.Net Install Guide

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

How to configure your Desktop Computer and Mobile Devices post migrating to Microsoft Office 365

Configuring an Client to Connect to CASS Mail Servers

for Networks Installation Guide for the application on the server August 2014 (GUIDE 2) Lucid Exact Version 1.7-N and later

Embarcadero Performance Center 2.7 Installation Guide

for Networks Installation Guide for the application on the server July 2014 (GUIDE 2) Lucid Rapid Version 6.05-N and later

How to Program a Commander or Scout to Connect to Pilot Software

How to install and use the File Sharing Outlook Plugin

How to Configure Outlook Client for Exchange

INSTALLATION GUIDE FOR ACTIVE X COMPONENT

Kaseya Server Instal ation User Guide June 6, 2008

Troubleshooting Guide

OneStop Reporting OSR Portal 4.6 Installation Guide

MelbourneOnline Hosted Exchange Setup

AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE

PageScope Enterprise Suite

GV-iView HD V1 for ipad

Xopero Backup Build your private cloud backup environment. Getting started

SWCS 4.2 Client Configuration Users Guide Revision /26/2012 Solatech, Inc.

Remote Monitoring and Control of the R&S FSV with a Web Browser

SELF SERVICE RESET PASSWORD MANAGEMENT BACKUP GUIDE

Apps for Android. Apps for iphone & ipad INS584-3

Phone: Fax: Box: 230

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Transcription:

Administrator s Guide for NETZSCH Remote Access Contents NETZSCH Remote Access Components... 2 Startup Order of the Remote Access service components... 2 Configuration... 3 Remote Access Setup Tool... 3 Initial Administrator Password... 4 Changing Administrator Password... 4 Reset Lost Administrator Password... 5 Instruments... 5 Enable or Disable the Remote Access for All Instruments on This Computer... 5 Enable or Disable the Remote Access for One Selected Instrument... 6 Advanced User Security... 6 Access to Remote Access Setup tool on Remote Computer... 8 Firewall... 9 Settings... 9 Ports used... 10 NETZSCH Instrument Cockpit App - Administrator Guide page 1/10

NETZSCH Remote Access Components NETZSCH Proteus software contains several components enabling remote access to the NETZSCH instruments: A. Service: 1. NETZSCH Remote Access Service: a Windows service enabling the access to the NETZSCH instruments from remote computers and devices; 2. NETZSCH Proteus software: controls the NETZSCH instrument on the measurement computer and communicates with the NETZSCH Remote Access Service. B. Clients: 1. NETZSCH Instrument Cockpit for Microsoft Windows http://www.netzsch.com/n24660 ; 2. NETZSCH Instrument Cockpit for ipad and iphone http://www.netzsch.com/n80379 3. NETZSCH Instrument Cockpit for Android www.netzsch.com/n24880. Startup Order of the Remote Access service components Remote Access for NETZSCH instruments word correct when the following start order is ensured: 1. NETZSCH Remote Access Service; 2. Measurement component of the Proteus software package. This startup order is ensured by default software installation because the NETZSCH Remote Access Service is set to automatic startup type. In the incorrect startup order the Remote Access service can t communicate correctly with the instruments installed locally on the measurement computer. Instrument Cockpit will not show NETZSCH instruments from this computer. NETZSCH Instrument Cockpit App - Administrator Guide page 2/10

Configuration Remote Access Setup Tool The NETZSCH Remote Access configuration can be defined in the Remote Access Setup tool from the Proteus 6.1 (or later) program folder: After start the login dialog will be shown: Initial administrator password is proteus. If the password is correct, the Remote Access Setup toll will be loaded: NETZSCH Instrument Cockpit App - Administrator Guide page 3/10

Initial Administrator Password Initial administrator password is proteus (case sensitive). Changing Administrator Password Start Remote Access Setup tool and select General item under Station in the toolbox of the left side. The computer name, description and also default user rights will be shown: Click on the Password button. Change Administrator Password form will be shown: NETZSCH Instrument Cockpit App - Administrator Guide page 4/10

Reset Lost Administrator Password Lost administrator password can t be restored. Administrator password can be reset to the delivery default value when any NETZSCH Proteus software instrument AddOn (usually it is delivered on the USB stick) will be installed. Please use the UPDATE setting: After that the administrator password s initial value proteus (case sensitive) will be valid for the next login into Remote Access tool. IMPORTANT: the restored initial password is valid for one login only! Please change the password immediately. Even if you want to use the initial password value in the future, it must be also changed (confirmed) during the first login after password reset. Instruments The instrument list in the toolbox contains all instruments installed on this measurement computer, compatible with Remote Access. It is not possible to add the NETZSCH instruments into this toolbox manually. The instruments are added there during first start the measurement software - so called First Connection. See instruments manual for details. Enable or Disable the Remote Access for All Instruments on This Computer In Remote Access Setup tool select General item under Station node in the toolbox left. Select or unselect the Remote Access Enabled check box on the General Options panel on the right side for enabling or disabling the remote access to all instruments connected to this computer: NETZSCH Instrument Cockpit App - Administrator Guide page 5/10

Enable or Disable the Remote Access for One Selected Instrument In Remote Access Setup in the toolbox select the instrument you want to enable or disable the remote access. In the Instrument panel on the right side for enabling or disabling the remote access to this instrument. Advanced User Security User Rights There are three user rights in Proteus software for the Instrument Cockpit: 1. View instrument state and signals (called also View ). This gives the possibility to see the same information as presented on blue hardware displays on some NETZSCH instruments like DSC, TG, STA or TMA. 2. Get current measurement data for analysis (called also Snapshot ). This gives the possibility to request from Instrument Cockpit the measurement data from this measurement computer to his computer. This measurement data will be sent either as a picture or as a NETZSCH measurement file if the user has Proteus software installed; 3. Stop the measurement in emergency case (called also Stop ). This gives a possibility to stop a wrong running measurement by using Instrument Cockpit from another computer. The right (1) have all users. Rights (2) and (3) can be assigned to: Any user accessing this computer; A user registered in Remote Access Setup tool on this computer. NETZSCH Instrument Cockpit App - Administrator Guide page 6/10

Access Rights for All Users In Remote Access Setup tool select General item under Station in the toolbox on the left side: In the right panel Default User Access Rights there are check boxes for two user rights: Snapshot and Stop. Selecting any of them will give these rights to all users who access this measurement computer from their Instrument Cockpit app. Adding a User for NETZSCH Remote Access It is also possible to get the Snapshot and Stop rights only to specific users. These users must be registered in Remote Access Setup tool first. These users are independent of Windows users and must be defined on all measurement computers they need separately. Click on Users item in the toolbox on the left side. The Create new User dialog appears: Type a user name and password (3 characters at least). After clicking on OK the user will be saved. It will appear also in the toolbox. NETZSCH Instrument Cockpit App - Administrator Guide page 7/10

Define an Access Right for a Specific User In Remote Access Setup tool select a user in the toolbox left: In the User Access Rights panel rights two check boxes defines the access rights for the current user. If no check box is selected the user has default minimum right View. Select a check box with the right you want to assign to the user and save the changes. The user will see the changes immediately in his Instrument Cockpit software. Access to Remote Access Setup tool on Remote Computer It is possible to start the Remote Access Setup tool on one computer and get access to the remote access settings on another computer with installed Proteus 6.1 or later. Administrator password on remote computer must be known. The file name of the Remote Access Setup tool is NgbRemoteAccess.exe and it is located in: C:\Program Files\NETZSCH\Proteus61\program (x86 version of Windows); C:\Program Files (x86)\netzsch\proteus61\program (x64 version of Windows). NETZSCH Instrument Cockpit App - Administrator Guide page 8/10

In Command Prompt window start the tool with -remote parameter: NgbRemoteAccess.exe remote The remote computer name and administrator password remote computer will be asked: When remote computer with typed name exists and the computer is accessible in the network, the Remote Access Tool will load all settings from this remote computer. Firewall Settings If the measurement computer is connected to Domain network profile the standard Windows Firewall settings usually allow the communication between NETZSCH Remote Access Service and Instrument Cockpit. The following programs must be allowed to get through the firewall: 1. Network Discovery; 2. Remote Access for NETZSCH Thermal Analysis Measurement. The last rule is added during the installation of the NETZSCH Proteus software. NETZSCH Instrument Cockpit App - Administrator Guide page 9/10

Ports used The following ports are used: HTTP port 80 for mobile clients (versions for ipad or Android); TCP port 8085 for Windows client. NETZSCH Instrument Cockpit App - Administrator Guide page 10/10