SMART Usage Reporting & Proactive Monitoring Aggregator



Similar documents
SMART Usage Reporting & Proactive Monitoring Aggregator

SMART Vantage. Installation guide

SMART Room Systems with Skype for Business usage reporting & proactive monitoring: Quality status details

Education Software Installer 2015

Interworks. Interworks Cloud Platform Installation Guide

Creating IBM Cognos Controller Databases using Microsoft SQL Server

Education Software Installer 2011

NTP Software File Auditor for Windows Edition

SMART Meeting Pro System Administrator s Guide

SMART Classroom Suite 2011

SMART Board 8055i and 8055i-SMP

Server Installation Guide ZENworks Patch Management 6.4 SP2

Education Software Installer 2014

Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1

Windows SharePoint Services Installation Guide

SMART Board 8070i-SMP and 8070i

StarWind iscsi SAN: Configuring Global Deduplication May 2012

Server Installation ZENworks Mobile Management 2.7.x August 2013

Reconfiguring VMware vsphere Update Manager

NetIQ Sentinel Quick Start Guide

NovaBACKUP xsp Version 15.0 Upgrade Guide

Diamond II v2.3 Service Pack 4 Installation Manual

Citrix EdgeSight for NetScaler Rapid Deployment Guide

Nexio Connectus with Nexio G-Scribe

Barracuda Message Archiver Vx Deployment. Whitepaper

Quick Start Guide For Ipswitch Failover v9.0

WhatsUp Gold v16.2 Installation and Configuration Guide

How To Set Up Chime For A Coworker On Windows (Windows) With A Windows 7 (Windows 7) On A Windows 8.1 (Windows 8) With An Ipad (Windows).Net (Windows Xp

Education Software Installer Activation frequently asked questions

SMS Database System Quick Start. [Version 1.0.3]

ARIS Education Package Process Design & Analysis Installation Guide. Version 7.2. Installation Guide

SELF SERVICE RESET PASSWORD MANAGEMENT BACKUP GUIDE

Reconfiguration of VMware vcenter Update Manager

SharePoint Server for Business Intelligence

Lepide Event Log Manager: Installation Guide. Installation Guide. Lepide Event Log Manager. Lepide Software Private Limited

Dell MessageStats for Lync and the MessageStats Report Pack for Lync & OCS 7.3. User Guide

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

Installing and Configuring vcenter Multi-Hypervisor Manager

XenClient Enterprise Synchronizer Installation Guide

How To Manage Storage With Novell Storage Manager 3.X For Active Directory

Citrix EdgeSight for Load Testing Installation Guide. Citrix EdgeSight for Load Testing 3.8

QUANTIFY INSTALLATION GUIDE

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

SafeCom Smart Printing Administrator s Quick Guide

Polycom CMA System Upgrade Guide

Administrator s Guide to deploying Engagement across multiple computers in a network using Microsoft Active Directory


Upgrade Guide BES12. Version 12.1

Avigilon Control Center Server User Guide

Enabling Remote Management of SQL Server Integration Services

Getting Started with ESXi Embedded

SMART Sync Windows operating systems. System administrator s guide

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Report Designer and Report Designer Add-In Installation Guide Version 1.0

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

Symantec AntiVirus Corporate Edition Patch Update

NTP Software File Reporter Analysis Server

Barracuda Message Archiver Vx Deployment. Whitepaper

SMART Vantage 1.0. SMART Vantage 1.0 server software updates

efolder BDR for Veeam Cloud Connection Guide

Veeam Backup Enterprise Manager. Version 7.0

Preinstallation Requirements Guide

Veeam Task Manager for Hyper-V

StreamServe Persuasion SP4

DameWare Server. Administrator Guide

SMART Meeting Pro Premium 2.3

Upgrading from MSDE to SQL Server 2005 Express Edition with Advanced Services SP2

SQL 2014 Configuration Guide

AvePoint CallAssist for Microsoft Dynamics CRM. Installation and Configuration Guide

Product Version 1.0 Document Version 1.0-B

How to Install MS SQL Server Express

Reconfiguring VMware vsphere Update Manager

Metalogix Replicator. Quick Start Guide. Publication Date: May 14, 2015

Preparing an IIS Server for EmpowerID installation

Software Installation Requirements

Kaseya Server Instal ation User Guide June 6, 2008

Installation Guide. Version 1.5. May 2015 Edition ICS Learning Group

DeviceAnywhere Automation for Smartphones Setup Guide Windows Mobile

Installation and Upgrade Guide

vrealize Air Compliance OVA Installation and Deployment Guide

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

Using Microsoft Windows Authentication for Microsoft SQL Server Connections in Data Archive

Technical Brief for Windows Home Server Remote Access

SQL Server 2008 R2 Express Edition Installation Guide

Lab 05: Deploying Microsoft Office Web Apps Server

Creating client-server setup with multiple clients

Installing and Configuring vcenter Support Assistant

Sophos Mobile Control Installation guide

Secure Agent Quick Start for Windows

Installation and Deployment

For Active Directory Installation Guide

Installation Guide. (June 2014)


AG MacOS Standalone Array Client Administration Guide

VMware/Hyper-V Backup Plug-in User Guide

Dell Statistica Statistica Enterprise Installation Instructions

Mobility Services Platform 3.1 Software Installation Guide

Available Update Methods

Synchronizer Installation

Omniquad Exchange Archiving

Transcription:

SMART Usage Reporting & Proactive Monitoring Aggregator INSTALLATION GUIDE FOR SMART ROOM SYSTEMS WITH SKYPE FOR BUSINESS NOTE This documentation has been updated to support Microsoft s transition from Lync to Skype for Business software. Most references to Lync have been removed and replaced with Skype for Business, however the following information is still applicable to SMART room systems running Lync software.

Product registration If you register your SMART product, we ll notify you of new features and software upgrades. Register online at smarttech.com/registration. FCC warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer s instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Trademark notice smarttech, the SMART logo and all SMART taglines are trademarks or registered trademarks of SMART Technologies ULC in the U.S. and/or other countries. Windows, Lync, Skype and Skype for Business are either registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. All other third-party product and company names may be trademarks of their respective owners. Copyright notice 2015 SMART Technologies ULC. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language in any form by any means without the prior written consent of SMART Technologies ULC. Information in this manual is subject to change without notice and does not represent a commitment on the part of SMART. This product and/or use thereof covered by one or more of the following U.S. patents. www.smarttech.com/patents 11/2015 smarttech.com/kb/170861

Introduction SMART Usage Reporting & Proactive Monitoring requires an aggregator service running in your environment. This service is a data collector which can be downloaded and installed by the customer. The data collector aggregates Skype for Business Monitoring Database information into an anonymized file which is transferred securely to the cloud based service. The cloud service provides a secure login for each customer. Only information from the SMART Room Systems with Skype for Business is reported. Purchasing SMART Usage Reporting & Proactive Monitoring To purchase SMART Usage Reporting & Proactive Monitoring, contact your SMART reseller. Register at smartview.smarttech.com/ucp/userregister.aspx using your entitlement key. Contact your SMART reseller for support with purchasing or registering. 3 smarttech.com/kb/170861

System requirements UC Point recommends to install the aggregator on a dedicated operating system. Installing the aggregator on the same server as Skype for Business could create conflicts. In case of support issues, UC Point only supports a dedicated standalone server running the aggregator. CAUTION UC Point recommends to not install the service on any Lync or Skype for Business Server. Supported Lync or Skype for Business on premise versions Supported Skype for Business Dedicated Online scenario Supported operating systems Supported virtualization environments Lync 2013 or higher. Lync or Skype for Business Monitoring Server has to be deployed. NOTE Lync or Skype for Business Server Multitenant environments are not supported! Daily snapshots of the LCScdr and the QoE metrics database have to be conducted by the customer. Then, the aggregator can collect the required data from the on-premise database snapshot. For Skype for Business Online the features of the SRS reports are available. Windows Server 2008 R2 / 2012 (64 bit) or higher Windows 7 (64 bit) or higher VMware HyperV Minimum system requirements RAM CPU Storage NIC Software prerequisites 4 GB or more 3 GHz or higher Minimum 40 GB including the operating system 100 Mbit or higher Microsoft.NET Framework 4.5 or higher Time has to be configured by an NTP server Internal communication ports SQL TCP 1443 4 smarttech.com/kb/170861

External communication ports SFTP TCP/UDP 22 DNS UDP 53 SQL permissions The aggregator is using a defined AD user account to collect the relevant data from the Skype for Business SQL databases LCScdr and QoE metrics. Defining the SQL user permissions To define the SQL user permissions 1. On the SQL server hosting the LcsCDR and QoE metrics Databases, open Microsoft SQL Management Studio. 2. Under Security, browse to Logins. 3. Right-click Logins > New Login. 4. Define the Login Properties by referring to the image below. 5 smarttech.com/kb/170861

Installing the SMART Usage Reporting & Proactive Monitoring aggregator NOTE Ensure the user you are using to install the SMART Usage Reporting Aggregator has local administrative permissions. To install the aggregator 1. Register for SMART Usage Reporting & Proactive Monitoring at smartview.smarttech.com/ucp/userregister.aspx. See Purchasing SMART Usage Reporting & Proactive Monitoring on page 3. 2. Log in at smartview.smarttech.com. 3. Click Setup > Download to download the latest version of the aggregator. 4. Open the folder where you downloaded smart_usage_reporting_kit.msi. 5. Right-click the.msi file. 6. Click Install. The SMART Usage Aggregator Setup window appears. 7. Click Next. The End-User License Agreement window appears. 8. Select the I accept the terms in the License Agreement check box. 9. Click Next. Select where to save the aggregator. 10. Click Next. 11. Enter the information for the user account you configured with SQL permissions and password. 12. Click Next. The Ready to Install SMART Usage Aggregator window appears. 6 smarttech.com/kb/170861

13. Click Install. NOTE If you have turned on User Account Control, you ll have to confirm the SMART Usage Aggregator can run on your computer. 14. Click Finish. Configuring the SMART Usage Reporting & Proactive Monitoring aggregator To configure the SMART UCP aggregator 1. Click Start > Run. 2. Type services.msc and click OK. The Services window appears. Verify if SMART Usage Reporting is listed and running. 3. Right-click SMART Usage Reporting and click Stop. 4. Click Start > All Programs > Accessories. 5. Right-click Notepad and click Run as administrator. 6. In Notepad, click File > Open and browse to the folder where you installed the program. The default location is C:\Program Files\SMART\usage\. 7. Right-click smart_aggregator_conf.xml and click Edit. 8. Change the XML settings as defined in Settings on the next page. When you re done, save and close the file. 9. In the Services window, right-click SMART Usage Reporting and click Start. 7 smarttech.com/kb/170861

Settings The following settings can be changed. Setting Use Notes Default XML parameters TransferMode TransferInterval TransferMethod TransferPort TransferTarget RemotePath TransferUser TransferPW LyncDBServer Sets when the data transfer occurs at the same time each day or if the data is transferred in intervals during the day. If the data is transferred in intervals, sets the interval between transmission from 15 to 720 minutes. Use the format hhmm to enter a value. Sets the file transfer method the aggregator uses as FTP or SFTP. Sets the TCP port for the file transfer from 1 to 65000. Sets where the aggregator transfers the files to the remote host. Sets the path on the remote target if it isn t the default. Replace your_portal_user with the user name used to log in at smartview.smarttech.com. Replace your_portal_password with the password used to log in at smartview.smarttech.com. Replace the name of your Lync or Skype for Business Monitoring Server database instance, for example sql.contoso.loc\instance01. Default is 1. 0 = fixed time 1 = interval Default is 0100 Default is SFTP. Default is 22 Default value is smartviewsftp.smarttech.com. Default is upload\. 8 smarttech.com/kb/170861

Setting Use Notes LyncStartCollectDate Enter the date when the aggregator will begin collecting data from the Lync or Skype for Business Monitoring database. The date can t be earlier than one month in the past. NOTE You re unable to set the date earlier than the earliest available data on the SQL instance. Format is yyyymmdd. Optional XML parameters DataPath Sets where the collected data is saved. Default is %system%\program Files\SMART\usage\data\ 9 smarttech.com/kb/170861

SMART TECHNOLOGIES smarttech.com/support smarttech.com/support/entsupport smarttech.com/kb/170861