Design Guidelines Space and Furniture Standards: Office, Meeting & Teaching Spaces



Similar documents
H107 Video Conference Room

Stanford University Space and Furniture Planning Guidelines

FURNITURE and MODULAR OFFICE SYSTEMS

Cleveland Clinic Room Templates

A1.5 Classroom Standards

Electrical. This section applies to the design and installation of building power distribution systems.

Students were surveyed by Brailsford & Dunlavey in the fall of 2000 to determine their priorities for Commons program spaces.

RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements

62% 40% 96% 90% 77% 40%

Server Racks, Cabinets, and Workspace Solutions

Technical Bulletin: Understanding the ADA and Implications for Office Design

Design Guidance: Learning Environments

4 RECORDS STORAGE OPTIONS

EXAM GUIDE. Schematic Design. Overview 2. Interior Layout Vignette 3 Sample Passing Solution 5 Sample Failing Solution 6

A/V and Video Conference Standards for Teaching and Learning Rooms.

BUILDING NAMING RIGHTS

HOLLAND HALL DESIGN UPDATE. Design Team

How To Build A Large Room For A Conference

Waste and Recycling Station Design Guidelines

Chief Facilities Officer-Associate Vice President of Facilities

Part 2 Definitions for this Policy 2.1. ADA / TAS the Americans with Disabilities Act / Texas Accessibility Standards.

Design an Effective TRAINING SPACE. White Paper

Applies to: All Employees within the Facilities Management Department (FMD)

Education & Meeting Room Facilities

NUMBER EFFECTIVE DATE. July 23, 2003

COMPUTER LAB CLASSROOMS. A Planning Guide

PUBLIC RESTROOMS, DESIGN INTENT

FLEX TECH BUILDING. Laramie County Community College LEVEL 1 REPORT APRIL 29, 2013 PAPPAS & PAPPAS ARCHITECTS, P.C.

Office Space Guidelines and Allocation Standards

A Project Description/Project Title and Data: Building Area: (sf) Addition 28,142 Renovation 14,302. Cost per Square Foot: +/- $106.

Facilities and Equipment

THE UNIVERSITY OF EDINBURGH. Number 5 Forrest Hill

1/9/2015 P:\ \Project Management\Program\Ripon Space Program - 7 January 2015.xlsx

Mequon - Thiensville School District Long Range Facilities Plan Monthly Project Schedule

New York City Department of Buildings

Classroom Technology Emergency Hot Line. Amherst College Classroom Technology Support. Classroom Equipment Guide. Fayerweather Classrooms

2D & 3D TelePresence

Classroom Design Guide

Table of Contents. I Introduction 2. II Definitions & Area Calculation 2. III Room Numbering 7. IV Appendix A 9

Machine Room Less (MRL) Elevators. Evolution in elevator design.

The emergency provisions affect the following Building Code sections:

College of Agriculture and Life Sciences Space Management Guidelines. College Space Assignments

Room Suggestions for Setup

Academic Learning and Teaching Center Classrooms

Meeting Room Configurations

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Acoustic design according to room type

Videoconferencing Room Guide

REQUEST FOR PROPOSALS

Appendix 3H A/V and Video Conferencing Standard

Revisiting Office Space Standards

The Impact of Building Shape on Space Planning Efficiency By Randall Walker, AIA, Executive Vice President, Kirksey

MARQUETTE UNIVERSITY: McCabe Hall

WELLINGTON E. WEBB MUNICIPAL OFFICE BUILDING DIVISIONS OF FACILITIES MANAGEMENT AND REAL ESTATE. Space Allocation and Furniture Standards

ADA HOTEL SITE INSPECTION CHECKLIST

Nursing School Classroom Technology Tips

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

SERC Audio Visual Options

Space Management Guidelines

D E F I N E V E L O D O. Telemedicine Room Design PROGRAM GUIDE. CTEConline.org

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

MSBA Guidelines for Science Labs

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

Production analogue video fed to Granicus encoder currently place Phase 3 will provide digital audio video to Granicus encoder

Conference Room Reservation Policy Packet

ACCESS AUDIT OF WESTPORT HOUSE

Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School

HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS PRIMARY CARE CLINICS

Gramercy Place Condo Association, Inc.

Element Z General Design Requirements Owner Standards and Other Requirements

GateWay Community College. Phoenix, Arizona, US. Case Study

Work Space and Office Furniture Standards December 2014

Chabot-Las Positas Community College District Bond Measure Technology Improvements Supplement to Capital Improvement Program

SERIES 600 ADMINISTRATIVE FACILITIES

Division / Space Total SF Status

Solution Components: REALPRESENCE IMMERSIVE TELEPRESENCE STUDIO TECHNICAL SPECIFICATIONS

MILTON HALL BCO AWARDS 2014 THE WORKSPACE CONSULTANTS LLP

CUSTOMER SERVICE COUNTER DESIGN GUIDELINES

EN The Tool for Tools

Audio Visual Products. Corporate Catalog 2015 P: F: Dukane Drive St Charles, IL 60174

Transcription:

Design Guidelines Space and Furniture Standards: Office, Meeting & Teaching Spaces 4 August 2014 1

Rowan University Design Guidelines - Space and Furniture Standards Table of Contents 1.0 Introduction 2.0 Definition of Terms 3.0 Space Planning Guidelines 3.1 Offices Introduction Program Guideline Summary 3.1.1 Dean s Office 3.1.2 Associate Dean s / Senior Director s Office 3.1.3 Department Chair s Office 3.1.4 Faculty / Project Manager s Office 3.1.5 Staff / Administration 3.1.6 Staff / Clerical Workstation 3.1.7 Adjunct Workstation 3.2 Meeting Spaces Introduction Program Guideline Summary 3.2.1 Department Chair s Conference Room 3.2.2 Small Conference Room 3.2.3 Medium Conference Room 3.3 Learning Spaces - Instructional, Collaborative, Interactive Introduction Program Guideline Summary Instructional 3.3.1 Small Classroom 3.3.1a Medium Classroom 3.3.2 Large Classroom 3.3.2a Multi-purpose Learning Space 3.3.3 Lecture Hall Collaborative 3.3.4 Seminar Room 3.3.5 Deep Well Classroom Arrangement One 3.3.6 Deep Well Classroom Arrangement Two Interactive 3.3.7 Group Projects Classrooms One 3.3.8 Group Projects Classrooms Two 2

1.0 Introduction Background Rowan University has developed space and furniture planning guidelines to serve as an aid in planning, allocating and managing space on the campus. These guidelines assist the Rowan community in establishing equitable, consistent, and flexible planning parameters. In addition, the guidelines assist the university community in making sound management decisions about space allocations both for new construction and within existing or renovated buildings. The space planning process is achieved through an evaluation of existing spaces through the use of space needs calculations. These calculations are based on the University s space planning guidelines and general planning assumptions that are reasonable and accepted by the University. These guidelines shall be periodically reviewed and updated as programs, teaching and learning pedagogies, and technological advances continue to evolve and influence the University s physical environment. The space and furniture planning guidelines are organized into three sections: office spaces, meeting spaces, and learning spaces. Space planning for offices is provided for faculty members as well as for administration and staff. Illustrations are provided with generalized criteria for furniture design. Meeting spaces are included to address a variety of size requirements. Learning space guidelines are divided into three categories: instructional, collaborative and interactive. Illustrations are provided of typical classroom arrangements to demonstrate clear planning principles. These categories reflect current trends in teaching spaces that accommodate the variety of teaching spaces now required in the University environment. Administration The Real Estate & Planning Department administers these guidelines and assists the campus community in their implementation and interpretation. The guidelines are updated by the Real Estate & Planning Department on a regular basis. As requests for new, renovated and reallocated spaces are forwarded and approved through the Capital Planning process, the Real Estate & Planning Department implements these guidelines. Design and Standards for Individuals with Disabilities Use of these standards and guidelines should be in compliance with the Americans with Disabilities Act of 1990 ( ADA ). Requirements for Rowan University are covered under Title II of the ADA. The Department of Justice published revised regulations for Titles II and III of the ADA in the Federal Register on September 15, 2010. These regulations adopted revised, enforceable accessibility standards called the 2010 ADA Standards for Accessible Design ( 2010 Standards or Standards ). The 2010 Standards set minimum requirements both scoping and technical for newly designed and constructed or altered State and local government facilities, public accommodations, and commercial facilities to be readily accessible to and usable by individuals with disabilities. Acknowledgements The Real Estate & Planning Department developed the Space Planning guidelines with the assistance of KSS Architects, LLP. 3

2.0 Definition of Terms Definition of Terms Following are the generally accepted defi nitions of the types of spaces and building areas that are relevant to these guidelines: Gross Square Feet gsf (also called bgsf-building gross square feet) - GSF is the total area of all fl oors of a building. This includes the area within the outside faces of exterior walls and fl oor penetration areas, however insignifi cant. GSF also includes all building structural, mechanical and other infrastructure systems, all building circulation space, and all support space such as public toilets, lobbies, etc. Gross area also includes space located above and below grade (basements). Net Assignable Square Feet nasf (also called nsf or asf -net square feet or assignable square feet) NASF refers to the space inside a room, as measured from interior wall to interior wall, including nooks and crannies which may exist in older buildings. It does not include building circulation, or areas such as restrooms, elevators and stairs. This is the space that is available for assignment to an occupant or for a specifi c use. The space guidelines are presented in terms of nasf. Net to Gross Efficiency - In the fi gures below, the effi ciency of net to gross square feet is 55%, which is fairly typical for buildings at Rowan and at our peer universities as well. The University continually analyzes building effi ciencies on the campus as we develop and plan new and renovated buildings. Our overall goal is to move toward the highest overall building effi ciency that we can achieve in the creation of an overall effective learning environment, while also meeting program needs and requirements. 4

3.1 Space Planning Guidelines: Offices Introduction The following guidelines articulate the sizes, utilization, and layouts for the various types of offi ces at Rowan University. Application of a modular planning approach, to preserve fl exibility of offi ce use over time. For example, colocating offi ces of similar sizes and types can be very useful as we think about future needs and changes in academic and other programs Placement of offi ces in the building core rather than along the windowed side of buildings, in order to create the fl exibility noted above as well as to promote air quality and to maximize light penetration for all building occupants. Location of interior windows and transoms will support offi ce quality. When possible persons supervising two persons or more should be assigned a private offi ce. Provide workspace confi gurations that optimize functionality and effi ciency and foster open communication while still protecting confi dentiality Provide adequate conference room space, for both smaller and larger gatherings Allow for adequate fi le storage, including compact storage (if deemed desirable and feasible) Allow for other common facilities such as: central supply room, restrooms, kitchenette facilities, and central copier facilities etc Develop an annual program by which offi ce occupants eliminate excess paper by sorting, purging and archiving their documents. Quite often offi ce occupants feel that their offi ces are cramped, only to fi nd that the space is adequate once a clean up day occurs. This can also help to identify specialized storage needs or furniture solutions that better organize offi ce spaces. Undertaking reviews of offi ce spaces to be sure that utilization continues to make sense, to update offi ce rosters, and to make any space reallocations that might be required Title nsf size occupants Dean s Offi ce 220 10% +/- 1-4 visitors Associate Dean s / Senior Director s Offi ce 175 10% +/- 1-4 visitors Department Chair s Offi ce 180 10% +/- 1-2 visitors Faculty / Project Manager s Offi ce 120 10% +/- 1-1 visitors Clerical Workstation 70 10% +/- 1 Adjunct Workstation 60 10% +/- 1 5

3.1.1 Dean s Office 220 nasf 20% +/- The Dean is assigned a single, private offi ce. Offi ces are intended to accommodate a workstation, lateral fi les, and bookcases for the Dean, plus a meeting area for up to an additional 4 people as needed. 1 WORKSTATION 1 TASK CHAIR ON CASTERS WITH ARMS 4 SIDE CHAIRS WITH ARMS 1 42. DIA. ROUND TABLE 2 BOOKCASES, 36 W X 12 0 X 84 H 2 LATERAL FlLES, 18 D, 2 DRAWER 1 MARKER BOARD, 36 W X 36 H 1 TACK BOARD, 36 W X 36 H Figure 3.1.1a Figure 3.1.1b 6

3.1.2 Associate Dean / Senior Director s Office 175 nasf 20% +/- Associate Deans and Directors are assigned a single, private offi ce. Offi ces are intended to accommodate a workstation, lateral fi les, and bookcases for the faculty member, plus a meeting area for up to an additional 2-3 people as needed. 1 WORKSTATION 1 TASK CHAIR ON CASTERS WIT ARMS 2 SIDE CHAIRS WITH ARMS 2 BOOKCASES, 36 W X 12 0 X 84 H 3 LATERAL FILES, 18 D, 2 DRAWER 1 MARKER BOARD, 36 W X 36 H 1 TACK BOARD, 36 W X 36 H Figure 3.1.2a Figure 3.1.2b 7

3.1.3 Department Chair / Director s Office 180 nasf 20% +/- Department Chairs are assigned a single, private offi ce. Offi ces are intended to accommodate a workstation, lateral fi les and bookcases for the faculty member, plus a meeting area for up to an additional 4 people as needed. 1 WORKSTATION 1 TASK CHAIR ON CASTERS WITH ARMS 4 SIDE CHAIR WITHOUT ARMS, STACKING 1 BOOKCASES, 42 W X 12 D X 84 H 1 MARKER BOARD, 36 W X 36 H Figure 3.1.3a Figure 3.1.3b 8

3.1.4 Faculty / Project Manager / Senior Manager s Office 120 nasf 20% +/- Full time tenure track faculty are generally assigned a single, private offi ce. Individual faculty offi ces are intended to accommodate a workstation, lateral fi les and bookcases for the faculty member, plus space to accomodate an additional person as needed. 1 WORKSTATION 1 TASK CHAIR ON CASTERS WITH ARMS 1 SIDE CHAIR WITH ARMS, STACKING 2 BOOKCASES, 42 W X 12 D X 84 H 1 LATERAL FlLE, 18 D, 5 DRAWER 1 OVERSTORAGE ADD ON, 36 W, 18 H 1 MARKER BOARD, 36 W X 36 H 1 TACK BOARD, 36 W X 36 H Figure 3.1.4a Figure 3.1.4b 9

3.1.5 Staff / Administration Service Spaces Typical offi ce service space needs (areas for fi les, non-staffed waiting areas, copy machines, supply storage, etc.) are based on a percent of the total calculated offi ce space required for a department, college or unit. For most academic departments and administrative units ten percent (10%) is used whereas for some larger administrative units such as colleges or senior administrative offi ces 20 percent (20%) is used. For other administrative departments, fi fteen percent (15%) should be used. Certain offi ce functions also have special service needs that are supplemental to the above guidelines. These additional needs are specifi c to certain units and include waiting rooms, processing rooms and departmental storage. A waiting room module of 120 ASF for most administrative offices should be used, while needs for student service operations are based on a factor of.02 ASF/Student FTE plus a 150 ASF minimum. Departments which have high daily client traffi c (i.e., senior administrative offi ces, student services operations) may require an expanded waiting room area. Other units may need special processing areas for assembling and distributing materials. A module of 500 ASF is recommended for processing rooms. A third special need is departmental storage for operations required to maintain and store records or files for extended periods such as human resources or the controller s office. A factor of 15 ASF per department FTE staff is recommended. Cubicle Spaces Staff may be accommodated in cubicle environments ranging from 64-80 nasf per person, depending on the type of work. In general, the 70 square foot cubicle is the preferred size; cubicles reach the 80 square foot range only for particular and specialized workrelated reasons. Cubicles are successfully used in a range of offi ce environments. Cubicle environments can have the benefi t of being more open, airy and light, and can make more effi cient use of space.such environments are particularly conducive to team-oriented offi ce groupings. Cubicle environments work best when they contain adequate numbers of conference and small group meeting spaces, for confi dential conversations and/or group tasks. Additional storage is sometimes required for fi le intensive offi ce groups. Sample layouts are shown below: 10

3.1.6 Staff / Clerical Workstation 70 nasf 20% +/- 1 WORKSTATION 1 KEYBOARD AND MOUSE PLATlFORM 1 TASK CHAIR ON CASTERS WITH ARMS 1 SIDE CHAIR WITH ARMS, STACKING Figure 3.1.5 3.1.7 Adjunct Workstation 60 nasf 20% +/- 1 WORKSTATION 1 KEYBOARD AND MOUSE PLATlFORM 1 TASK CHAIR ON CASTERS WITH ARMS Figure 3.1.5 11

3.2 Meeting Spaces and Conference Rooms Introduction The following guidelines articulate the sizes, utilization, and layouts for the various types of conference and meeting spaces at Rowan. Application of a modular planning approach, to preserve fl exibility of meeting space over time. For example, using modular furniture such as tables can be useful for multiple settings. Undertaking reviews of meeting spaces to be sure that utilization continues to make sense, to update offi ce rosters, and to make any space reallocations that might be required. Title nsf size occupants Department Chair Conference Room 300 10% +/- 8-10 Small Conference Room 430 10% +/- 18-24 Medium Conference Room 430 10% +/- 20-25 12

3.2.1 Department Chair Conference Room 300 nasf 20% +/- 8-10 people Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, locate screen to prime marker board space when screen is down. Portable Table top lectern, desk and chair 12 TASK CHAIR ON CASTERS WITH ARMS 4 TABLES, 30 D X 60 W 1 CONFERENCE CREDENZA, 22 D X 60 W 3 BOOKCASES, 36 W X 12 D X 84 H 1 MARKER BOARD, 120 W X 48 H X 1.5 NTS A/V NTS PROJECTION SCREEN X Figure 3.2.1a Figure 3.2.1b 13

3.2.2 Small Conference Room 500 nasf 20% +/- 20-25 people Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, Locate screen to provide marker board space when screen is down. Portable Table top lectern, desk and chair 20 TASK CHAIR ON CASTERS WITH ARMS 8 WORK TABLES, 30 X 60 1 COATSTAND 1 SIDE TABLE 2 MARKER BOARD, 120 W(min) X 48 H X 1.5 PROJECTION SCREEN X Figure 3.2.2a Figure 3.2.2b 14

3.2.3 Small Conference Room 430 nasf 20% +/- 18-24 people Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 18 TASK CHAIR ON CASTERS WITH ARMS 1 CONFERENCE TABLE, 48 X 180, WOOD VENEER 1 CONFERENCE CREDENZA. 22 X 60, WOOD VENEER 1 MARKER BOARD, 120 W(min) X 48 H X 1.5 PROJECTION SCREEN X Figure 3.1.4a Figure 3.1.4b 15

3.3 Learning Spaces - Instructional, Collaborative, Interactive Introduction The Classroom Design Guidelines are overarching principles to create functional, fl exible and aesthetically pleasing classrooms. Layout Instructive: generally designed with seating facing a podium, lecturn or instructor s desk; Collaborative: laid out in an open and circular, elliptical, rectangular or U-shaped arrangement Interactive: laid out in a variety of shapes, with groupings of two or more seats at a common workstation Acoustics Design walls and ceilings to evenly distribute sound through the classroom. Voices must be heard easily and accurately. Design must prevent unwanted background or outside noise. The room must be designed to foster effective sound transmission not only from a speaker at room front to an audience, but to allow student comments to be easily heard as well. Classroom acoustics must meet the standards recommended by the Acoustical Society of America (ASA). Figures given below refl ect the 2002 ASA standards. All walls must extend to the floor above or to the roof construction, and not stop at ceiling. Top and botom track joints must be sealed. Select system components (fans, ductwork and diffusers) that will meet the acoustical criteria for classrooms. Walls between classrooms must have a Sound Transmission Class (STC) rating of at least 50. Walls separating classrooms from common spaces or restrooms must have an STC of at least 53. Walls separating classrooms from mechanical spaces or other areas with high noise levels must have at least an STC of 60. Ambient noise level should not exceed 35 decibels when measured with the A-scale of a sound level meter. Reverberation time in rooms with under 10,000 cubic feet of space should not exceed.5 seconds. Spaces larger than 10,000 cubic feet should be designed for maximum reverberation time of.7 seconds. Walls and ceilings may require angling and/or applied acoustical treatment. Materials at room front should be reflective to project sound to the back of the room Flexibility Flexibility of use is important in this time of flux, which may continue for decades to come. We need to build spaces that aren t locked into one orientation or which make difficult future adjustments to opportunities afforded us by technology. Sightlines Sight-lines are as important as acoustical lines in the new media-rich classroom: knowledge can be displayed, can be visualized and simulated, so visual considerations are every bit as important as acoustic in URI classrooms. Technology Technology allows real-time construction of knowledge (visualization and simulation as just mentioned, or realtime group communication, or information from the Web), so built space should anticipate this possibility. The classroom is a working studio with the technology resources we have available. To accomodate real time knowledge processing that can be readily shared among the whole class. Classrooms must provide the space and furniture mobility for easy transition from working with computers back to wholegroup interaction. 16

3.3 Learning Spaces - Classrooms, Seminar Rooms, Lecture Halls Program Guideline Summary The table presented below provides a range of guidelines for different types of classroom spaces. Actual space per station, or per seat, in a classroom may vary depending on existing room confi guration as well as type of furniture and seating used (fi xed versus movable, tablet arms of varying sizes, tables, or theater-type seating). Also, as classrooms are increasingly outfi tted to accommodate sophisticated audiovisual equipment, streaming video, rear projection capacity, etc., the size of the rooms may need to be increased. In general, basic technology needs include a projector, white board, Ethernet connection, and video capacity. All classrooms should be proportioned to be more square than rectangular. All classrooms must be designed for 20 sf or larger per person including instructor. Title nsf occupants Small Classroom 480 min. 24 Medium Classroom 800 min. 40 Large Classroom 1000 min. 50 Multi-purpose Learning Space (movable furniture) 1200 min. 50-60 Multi-purpose Learning Space (fi xed table and seating) 2800 min. 61 + Seminar Room 525 min. 20 Deepwell Classroom Arrangement One 1750 10% +/- 80 Deepwell Classroom Arrangement Two 1500 10% +/- 60 Group Project Classroom Arrangement One 1200 10% +/- 25-35 Group Project Classroom Arrangement Two 1750 10% +/- 40-50 17

3.3.1 Small Classroom 480 nasf min. 24 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen: Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 26 SlDE CHAIR WITHOUT ARMS, STACKING 24 x72 DESKS 2 MARKER BOARD, 120 W(min) X 48 H HANDOUT SHELF PROJECTION SCREEN 48"H X WIDTH OF ROOM 3' - 0" 3' - 0" MIN. AISLE 9' - 0" 17' - 0" 3' - 0" MIN. AISLE Figure 3.3.1a Figure 3.3.1b 18

3.3.1a Medium Classroom 800 nasf 20% +/- 40 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen: Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 42 SlDE CHAIR WITHOUT ARMS, STACKING 24 x 72 DESKS 2 MARKER BOARD, 120 W(min) X 48 H AV RACK AV RACK ADDITIONAL LOCATION ADDITIONAL LOCATION 36" MIN. PROJECTIO N SCREEN PROJECTIO N SCREEN 90 DEGREE 90 VIEWING DEGREE CONEVIEWING CONE X 24' - 0" 2' - 7" 48"H X WIDTH 48"H X WIDTH OF ROOM OF ROOM 48"H X WIDTH OF ROOM 1.5 X 36" MIN. 33' - 0" Figure 3.3.1a Figure 3.3.1b 19

3.3.2 Large Classroom 1000 nasf min. 50 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located between 12-0 and 18-0 from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 54 SIDE CHAIR WITHOUT ARMS, STACKING 24 x 72 DESKS 3 MARKER BOARD, 36 W(min) X 36 H ADDITIONAL LOCATION AV RACK 36" MIN. PROJECTIO N SCREEN 90 DEGREE VIEWING CONE 2' - 7" 48"H X WIDTH OF ROOM 36" MIN. Figure 3.3.2a Figure 3.3.2b 20

90 X 3.3.2a Multi-purpose Learning Space 1200 nasf 50-60 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located between 12-0 and 18-0 from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 60+/- SIDE CHAIR WITHOUT ARMS, STACKING 24 x 72 DESKS 3 MARKER BOARD, 36 W(min) X 36 H 50-60 STUDENTS (MOVABLE FURNITURE) 61+ STUDENTS (FIXED TABLES AND CHAIRS ADDITIONAL LOCATION AV RACK 36" MIN. PROJECTIO N SCREEN DEGREE VIEWING CONE 2' - 7" 48"H X WIDTH OF ROOM 36" MIN. X 1.5 Figure 3.3.2a Figure 3.3.2b 21

3.3.3 Lecture Hall 2800 nasf 260 students, 1-2 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen: Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, depending on the size of the projected image. AV wall plate mounted on side wall closest to instructor console with inputs for female computer connection (VGA), computer audio connection (female mini), video connection (female BNC) and 2 audio connections (female RCA) for stereo audio. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 260 Fixed tables and seats - seats with arms must be no smaller than 22 wide 2 MARKER BOARD, 120 W(min) X 48 H 1 AV CLOSET X PROJECTION BOOTH HC SEATING W/ LOOSE CHAIRS (3 WHEELCHAIR SEATS + 4 COMPANION SEATS) 75' MAX TO INSTRUCTOR X 1.5 X 6 MIN 6" MIN RISE (12 (12" PREFERRED) PROVIDE CROSS AISLE W/ HC SEATING WHEN OCCUP. EXCEEDS 299 22" W (MIN) SEATS 15% LEFT HAND TABLETS (MIN) 140 SQ. IN MIN. TABLET SIZE INSTRUCTOR STATION STORAGE AV/IT CLOSET 2 PROJECTION SCREENS 24'W X 11'-4"H BOTTOM ATLEAST 4' AFF INSTRUCTOR STATION W/ AV EQUIPMENT CONTROLS AV EQUIPMENT RACK Figure 3.3.3a Figure 3.3.3b 22

3.3.4 Seminar Room 525 nasf 20% +/- 20 People Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located between 12-0 and 18-0 from the center of the bracket to the face of the projection screen, depending on the size of the projected image. 20 SlDE CHAIR WITHOUT ARMS, STACKING 8 SEMINAR TABLES, RECTANGULAR 2 MARKER BOARD, 120 W(min) X 48 H ADDITIONAL LOCATION PROJECTION SCREEN 42" to 48" TO BACK OF CHAIR IS GOOD. 5' - 0" 90 DEGREE VIEWING CONE X( ) 48"H X 96" W X Figure 3.3.4a Figure 3.3.4b 23

3.3.5 Deep Well Classroom Arrangement One 1750 nasf 20% +/- 80 students, 1-2 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen: Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 2 TASK CHAIR ON CASTERS WITH ARMS FIXED SEATS 12 FIXED LECTURE TABLES 2 MARKER BOARD, 120 W(min) X 48 H 1 AV CLOSET 2 PROJECTION SCREENS ATLEAST 4' AFF 90 DEGREE VIEWING CONE (2) 90 DEGREE VIEWING CONE VESTIBULE INSTRUCTOR STATION 31" MIN. FOR LOOSE SEATING 2' - 8" 22" W (MIN) SEATS 6" MIN. RISE (12" PREFERRED) RAMP 4' - 0" HC SEATING W/ LOOSE CHAIRS (3 WHEELCHAIR SEATS + 4 COMPANION SEATS) 20' - 6" PROJECTION BOOTH Figure 3.3.5a Figure 3.3.5b 24

3.3.6 Deep Well Classroom Arrangement Two 1500 nasf 20% +/- 60 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located between 12-0 and 18-0 from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 2 TASK CHAIR ON CASTERS WITH ARMS FIXED SEATS 15 FIXED LECTURE TABLES 2 MARKER BOARD, 120 W(min) X 48 H (2) 2 PROJECTION SCREENS INSTRUCTOR STATION 1482 SF 6" MIN. RISE (12" PREFERRED) 22" W (MIN) SEATS INTEGRAL SEATING HC SEATING W/ LOOSE SEATING (4 WHEELCHAIR SEATS AND 4 COMPANION SEATS) Figure 3.3.6a Figure 3.3.6b 25

3.3.7 Group Projects Classrooms 1200 nasf 20% +/- 25-35 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen: Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located a distance 1.5 times the screen width from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 28 SlDE CHAIR WITHOUT ARMS, STACKING 7 CLASSROOM TABlE, CIRCULAR 84 DIA. 1 MARKER BOARD, 120 W(min) X 48 H RAIL INSTRUCTOR STATION AV/IT CLOSET Figure 3.3.7a Figure 3.3.7b 26

3.3.8 Group Projects Classrooms 1750 nasf 20% +/- 40-50 students, 1 instructor Instructional Furniture and Equipment: Projection Screen: Electric, vinyl screen, 70 W x 70 H; Draper Signature series 5, recessed mounting when capable, mounted on front wall of classroom. Switch is to be located adjacent to the instructor console. LCD Projector: A ceiling-suspended LCD projector bracket centered on the projection screen and located between 12-0 and 18-0 from the center of the bracket to the face of the projection screen, depending on the size of the projected image. Portable Table top lectern, desk and chair 1 TASK CHAIR ON CASTERS WITH ARMS 36 SlDE CHAIR WITHOUT ARMS, STACKING 6 CLASSROOM TABLE, SEMI CIRCULAR 1 MARKER BOARD, 120 W(min) X 48 H INSTRUCTOR STATION 1 4 GROUP WORK STATIONS PARTS CART 2 5 3 6 2' - 9 3/16" 2' - 2 7/32" Figure 3.3.8a Figure 3.3.8b 27