CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET



Similar documents
CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

User Manual THR840DUK Digital Thermostat

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Drayton Digistat +2RF/+3RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Drayton Digistat +2RF

Heating Controller. Building Technologies HVAC Products

Wireless 7 Day Programmable Room Thermostat

Installation Guide for Hive Active Heating

Thermostat with display

Wireless Thermostats 230v and Battery Operated Instruction Manual

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

evohome Wireless Radiator Zoning Kit Installation & User Guide

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Digital timer thermosatat. isense. Installation and Service Manual AG

Aerona Air Source Heat Pumps

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Response: The combi boiler. Response: The fit anywhere combi

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

HERZ-Thermal Actuators

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Install Guide 3M-50. Caution. Caution

Operation Guide 3M-22

PS42309C INSTRUCTION MANUAL

BoilerMate SP. benchmark. user instructions A - C L A S S

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

REMOTE CONTROL MANUAL

Digital 2 Channel Time Clock EFFECTIVE: 1ST APRIL User Guide PB2CTC

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

For installation guide see reverse of book

How To Control A Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

User's Instructions. Alpha HE CB25/33 and HE SY25

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

HEAT PUMP PROGRAMMABLE THERMOSTAT

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Mode Switch. Fan Switch Menu button Program button

RF 1. Contents: Connecting diagram. Detailed information:

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Air-conditioning controller. User's Manual NRT 107 F031, F R R2 Sauter Components

R&D Electronics 8440 N. Waukegan Rd., Morton Grove, IL (847) Issue 12/08/06 om_207f.doc --

HCE80/HCC80/HCE80R/HCC80R

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Ground Resistance Clamp On Tester

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Baxi Combi 80e & 105e

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

ELECTRIC CENTRAL HEATING FLOW BOILER

Nest Learning Thermostat Installation Guide. Installation step-by-step

PK5500 v1.1 Installation Instructions

Installation & User Instructions

User Manual. Humidity-Temperature Chart Recorder. Model RH520

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Comfort Compact Controller ZG 215N

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

RRV934. Multi-controller. Synco living

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

B/S/H/ Error codes and service programmes PH

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Handheld portable appliance testers

Solar Weather Station Model: BAR806 / BAR806A

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Install Guide CT101. Caution. Caution

Electric Flow Boiler

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

HEAVY DUTY STORAGE GAS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

ES-LCD User Control SD Card Location

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Hygro-Thermometer + InfraRed Thermometer Model RH101

A Class Air Source Heat Pump User Guide

Adjustable room thermostat for heating only or cooling only systems

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Transcription:

CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes let you set 4 time and temperatures pairs to suit your lifestyle. Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point. /2 Program button allows switching to an alternative heating program whenever it s required with just one button press. This alternative program can be adjusted in exactly the same way as the normal heating program. Room Enquiry. EEPROM memory holds the user program indefinitely. OFF mode has an integral frost protection setting at minimum 5 C (installer adjustable) so that pipes in the house will never freeze in winter. 24...230V 5A resistive, 2A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. Battery powered by 2 x AA size (LR6) alkaline cells. Minimum battery life of 2 years with low battery warning indicator. Built-in default heating program. PRODUCT SPECIFICATION SHEET The CM702 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combi boilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The CM702 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM702 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an OK button makes it easier to install and more user friendly. The CM702 features a unique programming function that allows the user to select an alternative time & temperature profile whenever their lifestyle requirements change (e.g. weekend, bank holiday). The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product. Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation. No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. User Set-Up Mode allows extra functions to be set at the discretion of the user: AM-PM or 24hr time display. Resetting the heating profile to factory default. Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs: Pump Exercise. Upper / Lower Set point Adjust. offset. Minimum ON time. Cycle rate. Proportional Band Width. Diagnostic Mode to assist in fault finding. EN0H 8545 UK07 R 09/06

CONTROLS / DISPLAY LAYOUT PRODUCT LAYOUT:. LCD Screen 2. Battery Low Indicator 3. Time Display 4. Burner On Indicator 5. Display 6. Change Buttons 7. Information Enquiry Button 8. Operating Mode Buttons 9. Green OK Button 0. Battery Compartment. Battery Cover 2. / 2 Program Button 3. Program Buttons 4. Time Change Buttons SPECIFICATION S Batteries Battery life Battery replacement Switch type Electrical rating Time display Time keeping accuracy Program Time setting resolution : 2 x.5 V IEC LR6 (AA) Alkaline cells : Minimum 2 years : Program retained in EEPROM : SPDT (potential free) : 230 V~, 50...60 Hz, 0. A to 5 A resistive 0. A to 2 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf) : 24 hour or 2 hour AM/PM format : Typically better than 0 minutes per year : 2 independent sets of 4 daily time and temperature level changes that can be switched between as desired. : Time of day - minute Program - 0 minute steps Sensing element : 00K (@ 25 o C ) NTC thermistor setting range : Program : 5 to 35 o C in 0.5 o C steps Frost : 5 o C or equal to lower limit (5 o C to 2 o C). control accuracy Room display range Control form Minimum ON time Cycle rate Wiring Wire access : ±0.5 K (nominal) @ 20 o C, 50% load 3 K Δ/hour : From 0 o C to 50 o C : P + I (Proportional + Integral) : 0% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) : Selectable by application (see installer set up) : Terminal block capable of accepting wires up to 2.5 mm 2 : Mains wiring rear right. Low voltage wiring rear right. Dimensions : 33 x 88.5 x 26 mm (w x h x d) 33 x 75 x 26 mm (w x h x d) (flap open) Environmental Approvals : Operating temperature range 0 to 40 o C Shipping and storage temperature range -20 to 55 o C Humidity range 0 to 90% rh, noncondensing : Designed to meet European EN approvals EN60730-(Nov 2000), EN5504- (997), EN5504-2 (2000) 2 EN0H 8545 UK07 R 09/06

INSTALLER SET-UP To enter the installer set-up mode: a) Press the OFF button. b) Press and hold the INFO i button and the two program buttons < > together. c) The unit will display the first parameter of installer parameter group category (from n. to n.9). d) Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter. g) Press the program button > to go to category 2 in the Installer mode (from n. to n.5). h) To exit the installer mode, press the AUTO, MAN or OFF buttons. Abbreviated Set-Up Description e.g. Cl = Clock Format In Installer set-up we can: Set-up specific applications Enable special features Installer Set-up Number (Press + or - to change) e.g. = Clock Format Factory Setting or New Choice Press TEMP or to change e.g. 2 = AM/PM Format 24 = 24hr Format Specific Applications Setting What do you need to change? Cycle/ Hour Minimum ON time (in minutes) Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n., category 2 in the installer set-up mode. Heating Gas Boilers (<30KW) 6 No action required Oil Boiler 3 4. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Thermal Actuator 2 Set Cycle/Hour to 2. Zone valve 6 No action required. Electric heating (for applications <5A) 2. Set Cycle/Hour to 2. 3 EN0H 8545 UK07 R 09/06

Special Features Description What to do if we wish this feature AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n., category in the installer set -up mode to 2. Pump exercise Upper Lower Offset Proportional Band Width When enabled the Pump Exercise will switch the relay on for minute at 2:00 if the relay has not been switched on since 2:00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. The normal upper temperature limit of 35 o C can be reduced down to 2 o C to save the homeowner energy. Useful if the homeowner rents to tenants. The normal lower temperature limit of 5 o C can be increased up to 2 o C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. If the thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 o C. Useful if the homeowner wants the reading to match another appliance temperature display. Can be adjusted up to 3 o C (default is.5 o C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems. b. Air systems with fast response. Set parameter n.5, category 2 in the installer set -up mode to. Set parameter n.6, category in the limit. Set parameter n.7, category in the limit. Set parameter n.2, category in the offset value. Set parameter n.3, category in the value. 4 EN0H 8545 UK07 R 09/06

Parameter Installer Set-Up Number / Abbreviation (Press + or - keys to select) Factory Setting Optional Setting Installer Set- Up Category Display Description Display/Setting Description (Press PROG keys < or > to select) Category : Thermostat Parameters AM-PM / 24hr Display :Cl 24 24 hr clock display 2 2 hr AM / PM clock display RESET Time / Program 2:rP Time / profile set to factory default Changes to 0 when one of the time/temp profiles are changed 0 Time / are as programmed To restore the factory profile set to Upper 6:uL 35 35 C Upper Temp. 2 to 34 2 C to 34 C adjustment in C steps Lower 7:LL 5 5 C Lower Temp. 6 to 2 6 C to 2 C adjustment in C steps Offset 2:tO 0 No offset -3 to +3-3 C to +3 C adjustment in 0. C steps Proportional Band Width 3:Pb.5.5 C Proportional Band.6 to 3.0.6 C to 3.0 C adjustment in 0. C steps Reset Parameters to Factory Defaults 9:FS All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed 0 Settings are as modified above To restore the factory profile set to Category 2: System Parameters (You must press the > program key to enter this section) Minimum ON Time :Ot minute minimum ON time 2 to 5 2-2 minutes 3-3 minutes 4-4 minutes 5-5 minutes 2 Cycle Rate 2:Cr 6 6 cycles per hour (cph) for gas boilers, zone valves and fan-coil 3, 9, 2 3-3 cph 9-9cph 2-2 cph 2 Pump Exercise 5:PE 0 Pump Exercise Pump Exercise Enabled 2 5 EN0H 8545 UK07 R 09/06

DIMENSIONS INSTALLATION LOCATION The CM702 thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall,.5 metres above the floor level. Do not position the CM702 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. MOUNTING The CM702 thermostat can be mounted directly on the wall surface or on to an electrical wall box. WIRING The CM702 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT. The installer must be a trained service engineer 2. Disconnect the power supply before beginning installation 6 EN0H 8545 UK07 R 09/06

WIRING ORDERING SPECIFICATION Description Model Logo Literature Availability Spec Sheet + day programmable thermostat CMT702A004 Honeywell French, Dutch, Italian, Spanish, German, Portuguese. Sep 05 ENOH8545 + day programmable thermostat with 6 switch points (instead of 4). CMT702A02 Honeywell French, Dutch, Italian, Spanish, German, Portuguese. Oct 06 ENOH8545 Honeywell Control Systems ed Newhouse Industrial Estate Motherwell ML 5SB United Kingdom http://europe.hbc.honeywell.com EN0H 8545 UK07 R 09/06