Development of Virtual Accelerator Environment for Beam Diagnostics *



Similar documents
Slice Emittance Measurements at the SLAC Gun Test Facility*

Damping Wigglers in PETRA III

STUDY OF THE TRANSVERSE BEAM EMITTANCE OF THE BERN MEDICAL CYCLOTRON

Results: Low current ( ) Worst case: 800 MHz, GeV, 4 turns Energy oscillation amplitude 154 MeV, where

LHC optics measurement & correction procedures. M. Aiba, R. Calaga, A. Morita, R. Tomás & G. Vanbavinckhove

Frequency Map Experiments at the Advanced Light Source. David Robin Advanced Light Source

Status Overview The Australian Synchrotron. Steven Banks Control Systems Group

X-Ray Free Electron Lasers

BEAM OPERATION OF THE PAL-XFEL INJECTOR TEST FACILITY

Comb beam for particle-driven plasma-based accelerators

Status of the SOLEIL project Commissioning from Linac to beamlines

Status Report on Tools Development. Work done by O. Hensler, R. Kammering, T. Limberg, S. Meykopff, C. Schmidt, M. Tischer, M. Vogt and many more

RF-thermal-structural-RF coupled analysis on the travelling wave disk-loaded accelerating structure

BEPC UPGRADES AND TAU-CHARM FACTORY DESIGN

Libera at ELETTRA: prehistory, history and present state

Status of the Free Electron Laser

Mission: Cure, Research and Teaching. Marco Pullia Cnao design and commissioning

Figure 1: Lattice drawing for the APS storage ring.

Beam Dynamics Studies and Design Optimisation of New Low Energy Antiproton Facilities arxiv: v1 [physics.acc-ph] 21 Jun 2016

The accurate calibration of all detectors is crucial for the subsequent data

Zero Degree Extraction using an Electrostatic Separator

FACET First Beam Commissioning. Jerry Yocky For the FACET commissioning team 21-May-2012 IPAC 2012, New Orleans, LA

11th International Computational Accelerator Physics Conference (ICAP) August 19 24, 2012, Rostock-Warnemünde (Germany)

Proton tracking for medical imaging and dosimetry

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

Cathode Ray Tube. Introduction. Functional principle

World-first Proton Pencil Beam Scanning System with FDA Clearance

Towards large dynamic range beam diagnostics and beam dynamics studies. Pavel Evtushenko

Copyright. Ryoichi Miyamoto

A Quick primer on synchrotron radiation: How would an MBA source change my x-ray beam. Jonathan Lang Advanced Photon Source

A new extraction system for the upgraded AIC-144 cyclotron

Energy Deposition in MICE Absorbers and Coils

THE ALIGNMENT STRATEGY FOR THE SPIRAL2 SUPERCONDUCTING LINAC CRYOMODULES

Spin Tracking with COSY INFINITY and its Benchmarking

Activities at the University of Frankfurt (IAP)

AUTOMATION OF OPERATIONS ON THE VEPP-4 CONTROL SYSTEM

Calculation of Eigenmodes in Superconducting Cavities

Data-analysis scheme and infrastructure at the X-ray free electron laser facility, SACLA

Technical Report FP Simple injector for high-current sheet electron beams

THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK

Institute of Accelerator Technologies of Ankara University and TARLA Facility

Catherine LeCocq, Robert Ruland. February, 2008

Making Better Medical Devices with Multisensor Metrology

LLRF. Digital RF Stabilization System

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

SIMULATIONS OF ELECTRON CLOUD BUILD-UP AND SATURATION IN THE APS *

Brookhaven Magnet Division - Nuclear Physics Program Support Activities

Development of on line monitor detectors used for clinical routine in proton and ion therapy

NANOFLAM. Projet ANR Blanc 2011 BS Aide allouée: , durée 36+8 mois (fin : Mai 2015) Laboratoire H. Curien

EMR-9 Quick Start Guide (00175)D 1

Time Domain and Frequency Domain Techniques For Multi Shaker Time Waveform Replication

Chapter 2 The Research on Fault Diagnosis of Building Electrical System Based on RBF Neural Network

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

Status of IP FB system design

Systems, Inc. Energy Advanced

IBA Proton Therapy. Biomed days Vincent Bossier. System Architect Protect, Enhance and Save Lives

Tune and Chromaticity Tracking in the Tevatron. C.Y. Tan 09 May 2006

Information about the T9 beam line and experimental facilities

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Beam Instrumentation Group, CERN ACAS, Australian Collaboration for Accelerator Science 3. School of Physics, University of Melbourne 4

Lecture VI Magnetic Design

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

Calorimetry in particle physics experiments

Electrostatic electron analyzer with 90 deflection angle

Millijoules high master-slave pulse ratio 532 nm picosecond laser

Proposed experiment to test the non-locality hypothesis in transient light-interference phenomena

VIIRS-CrIS mapping. NWP SAF AAPP VIIRS-CrIS Mapping

Electric and Magnetic Field Lenses


EDUMECH Mechatronic Instructional Systems. Ball on Beam System

ON-LINE MONITORING OF AN HADRON BEAM FOR RADIOTHERAPEUTIC TREATMENTS

Manufacturing Process and Cost Estimation through Process Detection by Applying Image Processing Technique

SOLEIL Current Performances. And. Futur Developments

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

Recommended alignment procedure for Shaper 6_6 / Focal- Shaper 9

OAG Tools for General Users

Straightness Measurements for Accelerator Structures

Status of High Current Ion Sources. Daniela Leitner Lawrence Berkeley National Laboratory

Reflection and Refraction

ARTIFICIAL NEURAL NETWORKS IN THE SCOPE OF OPTICAL PERFORMANCE MONITORING

Photonic & Fiber Alignment Engines

Impedance 50 (75 connectors via adapters)

ELECTRON SPIN RESONANCE Last Revised: July 2007

Mark Jaski. Multi-Bend-Achromat (MBA) Magnets

EPICS VME Crate Monitor Software Design Note Rev. 0 Date:

Optical Design Tools for Backlight Displays

Event display for the International Linear Collider Summer student report

HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON

Polarization of Light

Transcription:

Development of Virtual Accelerator Environment for Beam Diagnostics * Gu Duan, Zhang Meng, Gu Qiang, Huang Dazhang, Zhao Minghua (Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China;) Abstract: For the proper operation of Dalian Compact Light Source (DCLS) linac, measurement and control of the electron bunch is critical. In order to test control algorithms and high level physical applications, a virtual accelerator environment is constructed based on ELEGANT and SDDS toolkit. The required beam parameter measurement and orbit control tools are verified under this virtual environment and it will greatly speed up the development of machine commissioning tools. The design concept and current development status are presented. Key words: virtual accelerator environment; beam parameter measurement; high level application PACS:29.20.-C CLC number: TL506 Document code: A Dalian Coherent Light Source is a free electron laser user facility based on the principle of single-pass, high-gain harmonic generation scheme [1]. During the commissioning of the linac section, beam parameter measurement is important, meanwhile, beam correction is indispensable for the stable operation of the machine. To expedite the design of measurement tools, Virtual Environment (VA) has been widely used on many facilities [2-6]. Usually, beam energy and energy spread are measured by a diagnostic system that consists of a bending magnet and the following beam profile monitor, and the transverse beam emittance is measured using the so-called Quadrupole Scan method. Beam orbit is measured by Beam Position Monitor (BPM) along the beamline and the orbit correction is implemented using the dipole correctors. Resolution and accuracy of the beam instrument should be specified during the design stage and analysed during the commissioning stage. In order to evaluate the feasibility of beam diagnostic systems, a virtual accelerator environment based on ELEGANT [7] and SDDS toolkit is developed. With the tools and interfaces provided by this VA, the beam behaviours simulated by physics codes can be directly handled to High Level Applications (HLA), this will greatly speed up the development of machine commissioning tools. In its first part, this paper focuses on the concept of the virtual accelerator environment and its role during the communication between physics codes and high level applications. In the second part, with the flexibility of this environment, the energy and energy spread measurement tools based on it are shown, which can be used to find the proper RF phases before and after chicane. In the third part, beam emittance measurement tools based on VA is * Received date: ; Revised date: Foundation item: Supported by Knowledge Innovation Program of CAS and Natural Science Foundation of Shanghai City, Grant No. 12ZR1436600. Biography: Gu Duan (1982 ), male, PhD candidate, engaged in accelerator physics and diagnostics; e-mail: guduan@sinap.ac.cn Corresponding author: Zhao Minghua (1961 ), male,; e-mail: zhaominghua@sinap.ac.cn.

shown. Using this tool, the transverse parameters which give the information for the beamline can be derived. The fourth part describes the design of the beam orbit correction tool and the response matrices acquirement both theoretically and experimentally. In the final section a short conclusion is given. 1 Virtual accelerator environment based on ELEGANT and SDDS toolkit SDDS toolkit and ELEGANT code have been extensively used during the design of Dalian Compact Light Source. Integrating physics codes into control system will give great potential to optimize the machine commissioning and operation. So we have developed a Virtual Accelerator to provide tools for integrating and interfacing different simulation codes into the control system. The VA uses ELEGANT code as the simulator of beam dynamics to simulate the behaviour of electron beam, meanwhile, with the combination of SDDS toolkit, the VA can also provide data pre-processing and exchanging for different simulation codes. As the control system is based on Experiment Physics and Industrial Control System (EPICS) [8], the communication and data transfer are provided by using the EPICS portable Channel Access (CA), so a set of utilities for interfacing the VA and the high level control system have been developed. In this way, the VA will operate just like the real machine from the view of EPICS channel. The structure of the Virtual Accelerator compared with real machine is shown in Fig. 1. Matlab High Level Application Middle Layer MCA MCA+Shell Scripts EPICS EPICS + Matlab Scripts Hardware (Quad, BPM, Magnets...) ELEGANT & SDDS Toolkit Real Machine Virtual Environment Fig.1 The structure of the virtual accelerator compared with real machine In the case of DCLS, the High Level Applications (HLA) including Graphical User Interface (GUI) has been designed on MATLAB platform. In order to enable the communication between HLA and the physics simulation codes, an I/O interface is developed which can convert files between the SDDS format and the Matlab format. With the flexibility of the built-in functions in SDDS toolkit, the SDDS format file can be loaded directly into Matlab HLA. An example of reading and display the output beam distribution from simulation is shown as Fig. 2.

(a) beam distribution read from ELEGANT (b) beam distribution converted by MATLAB Fig. 2. Simulated and converted beam distributions For the reverse path, the parameters and configurations from HLA can be passed to physics simulation codes via the specified function. The conversion between machine quantities (e.g. current in Ampere) and physics quantities in simulation codes (e.g. quadrupole strength K in m -2 ) are calculated and stored in advance so the VA can be operated like an online machine. 4 Beam parameter measurement in longitudinal direction With the flexibility of VA environment, we can measure and tune the longitudinal beam parameters for the DCLS linac. According to the design layout, beam energy and energy spread measurement are routinely carried out at three beam diagnostics locations: at the exit of RF gun, at the exit of ACC2 and at the linac end. The basic layout of bending magnet system is shown in Fig. 3. The beam energy can be evaluated from the magnetic field of the bending magnet as described in Eq. 1. E[ MeV ] 299.8 B[ T m] (1) where is the bending radius which is fixed by the geometric distance between profile and bending magnet, B is the magnetic field of the bending magnet which is controlled by current [9]. In order to simulate the usual procedure of energy measurement, during the calculation of the beam distributions using simulation code, each location equipped with one watch point element, by which we can Profile QUAD Bend Magnet Profile Fig. 3. The basic layout of bending magnet system get the theoretic 3D beam distribution. As the beam energy distribution is characterized by analyzing the transverse profile collected on a profile, only the x-y plane beam information are handled to reconstruct the beam transverse distribution. The beam shape and center are fitted using Gaussian fit method and shown on the HLA panel. As described in Eq.1, the beam energy can be determined as long as the current of bending magnet is measured.

Meanwhile the energy spread measurement is carried out using the same structure. The energy spread is derived by measuring the beam size at the profile screen and acknowledging the local dispersion [10]. The transverse beam size is measured in a dispersive location has two sources. where is the beam s betatron 2 2 beam size and is the size due to dispersion. So the energy spread is = D / E. Where D is the dispersion. when, the betatron contribution can be ignored, then the energy spread can be dominated by transverse beam size and dispersion only. By using the strategy above, the upstream quadrupoles are optimized to get the minimum betatron contribution after 30 degree bending magnet, then the according energy spread is determined [11]. The final energy spread measurement interface is shown as Fig 4. E beam Fig. 4. The final energy spread measurement interface The linac is operated off-crest to chirp the bunch for longitudinal compression. In practice, the accelerate phase is indicated by the offset of minimum energy spread from maximum energy [12]. Using energy and energy spread data from previous measurements, the required RF phase of subsequent accelerate modules can be found where the energy spread is the smallest as shown in Fig. 5. Fig. 5. Seek the required RF phase of subsequent accelerate modules. 3 Beam emittance measurement in transverse direction As one of the most important judgments of beam quality, projected emittance measurement is critical for optics matching in linac. Many different ways have been studied to measure the emittance, in the case of DCLS, an

automatic measurement tool is developed based on VA using Quadrupole Scan method [13]. During the scanning, 2 with assuming the thin lens approximation, the correlation between s and K Lq is given as Eq. 2. A( K L ) 2 A B( K L ) ( A B C) (2) 2 2 2 s q q Where s is the rms beam size on the profile screen, L q is quadrupole length, K is the normalized quadrupole strength, A, B and C are coefficients that can be fitted by the second order polynomial fitting. The normalized projected emittance n can be written as n AC / Ld. Where L d is the length of drift between quadrupole and profile screen. There are five reserved diagnostics locations for emittance measurement and each location equipped with one profile, after scanning the upstream quadrupole, the emittance measurement tool can extract the transverse beam size on profile and estimate the transverse beam emittance at the entrance of the scanned quadrupole. The emittance will be determined for both horizontal and vertical plane simultaneously. At the same time, twiss parameters at the entrance of scanned quadrupole can also be measured. Space charge forces are not included in the emittance analysis and should have no significant impact at these energies [14]. During the tracking in ELEGANT, 100000 particles are used, when the beam image converted from beam distribution loaded, it is shown in a 10mm 10mm area, the pixel calibration is10um/pixel. In order to remove the influence of background noise, an averaged background image is subtracted from each beam image in Matlab procession. When the emittance measurements are performed sequentially at each diagnostic location, useful information about the emittance transport through the linac can be obtained [15]. An example of emittance measurement software interface and result is shown as Fig. 6. In which the scanned quadrupole values versus observed beam size square are measured and then fitted. Finally the emittance of 1mm mrad were determined from the fitted curves for both horizontal and vertical planes. (a)emittance measurement interface (b) emittance measurement example result Fig. 6. Emittance measurement software interface and result example.

4 Beam orbit correction With the existence of element misalignments, the orbit need to be corrected. Usually, a common used SVD based orbit algorithm like Global method is applied on the linac. Beam orbit correction is accomplished using BPM readings and in turn correct the orbit with dipole magnets. Correction tools has been developed and debugged under the VA environment. This algorithm relies mainly on a so-called Response Matrices which maps the orbit changes due to the corrector kicks. The main issue when applying orbit correction is how to get the according response matrices for both planes. Fortunately, the theoretical response matrices can be computed by ELEGANT and imported into a Matlab Orbit Correction tool. Experimentally, the response matrices can be determined by measuring the BPM readings while varying the current of each dipole corrector. Compared with the time consuming experimental measurement, using the theoretical response matrices is much faster and can be applied to the orbit control system without affecting the facility operation. Considering the demand of verify the consistency between the theoretical and experimental model. Fig. 7 shows the typical improvement in beam position at each BPM achieved by the correction tool. In this example, each quadrupole is assumed with 100μm transverse offset with respect to a straight line. In the horizontal plane the RMS error is reduced from 0.41mm to 0.06mm while in the vertical plane the RMS error is reduced from 0.52mm to 0.05mm. 1 x 10-3 Orbit X (m) 0.5 0-0.5 uncorrected corrected -1 0 5 10 15 20 25 30 35 S (m ) Orbit Y (m) 1 x 10-3 0.5 0-0.5 uncorrected corrected -1 0 5 10 15 20 25 30 35 S (m ) Fig. 7. Improvement after orbit correction for both vertical and horizontal planes. 5 Conclusion A set of beam parameter measurement and orbit control tools based on virtual accelerator environment have been developed. The VA environment provides flexible data process interfaces with physics simulation codes. The theoretical model from simulation can be directly imported into high level applications or through EPICS channel access. Different beam measurement procedures and correction methods can be tested and verified benefited from

this VA environment. Successful integrating this VA environment into the control system will greatly improve the machine performance in the DCLS commissioning. References [1] Harada, H. et al. Development of Virtual Accelerator Environment for Beam Diagnostics[C].//Conf.Proc. C060626 2224-2226. 2006. [2] T. Zhang, H.X. Deng, D. Wang, Z.T. Zhao, et al. Generating Polarization controllable FELs at Dalian coherent light source[c].//4 th International Particle Accelerator Conf. 2013. [3] Wang Pengfei, Cao Jian-She1, Ye Qiang. The Development of ADS Virtual Accelerator Based on XAL[J]. arxiv: 1309: 4164. [4] Colwyn Gulliford, Adam Bartnik, Ivan Bazarov, et al. Demonstration of Low Emittance In The Cornell Energy Recovery Linac Injector Prototype[J]. Phys. Rev. ST Accel. Beams, 2013, 16:073401 [5] A. Shishlo, P. Chu, J. Galambos, T.A. Pelaia. The EPICS Based Virtual Accelerator - Concept and Implementation[C].//Conf.Proc. C030512:2366, 2003. [6] P. C. Chiu, C. H. Kuo, Jenny Chen. Virtual Accelerator Development For The TPS[C].//IPAC 10, Kyoto, Japan 2010 [7] M. Borland. Elegant: A Flexible SDDS-Compliant Code for Accelerator Simulation[J]. Advanced Photon Source LS-287, 2000 [8] Coyle E J, Jamieson L H, Oakes W C. EPICS: Engineering projects in community service[j]. International Journal of Engineering Education, 2005, 21(1): 139-150. [9] C.D. Tennant. An Approach to Measure Both Emittance and Energy-Spread in the Extraction Region of CEBAF-ER[R], JLAB-TN-03-005,2003. [10] R.Akre, D.Dowell, P.Emma et al. Commissioning the Linac Coherent Light Source injector[j]. Phys. Rev. ST Accel. Beams, 2008, 11:030703 [11] J.B. Lallement, G. Bellodi, M. Eshraqi et al. Linac4 Commissioning Strategy[C].//HB2010, Switzerland TUO1D01, 2010 [12] Paul Emma. First Lasing of the LCLS X-ray FEL AT 1.5 Å[C].// PAC09, TH3PBI01,2009 [13] CHEN Yan-Wei,WANG Shu-Hong,PEI Guo-Xi,LIU Wei-Bin,YE Qiang.Beam Commissioning of BEPCII Injector Linac[J], HEP & NP, 2006,30(06):562-565 [14] Wolski, Andy. Low emittance machines[r]. CERN Accelerator School. 2007. [15] S. Di Mitri, M. Cornacchia, C. Scafuri et al. Electron beam optics and trajectory control in the Fermi free electron laser delivery system[j]. Phys. Rev. ST Accel. Beams, 2012,15:012802. 束 流 诊 断 虚 拟 加 速 器 环 境 开 发 谷 端, 张 猛, 顾 强, 黄 大 章, 赵 明 华 ( 中 国 科 学 院 上 海 应 用 物 理 研 究 所, 上 海,201800) 摘 要 : 在 大 连 紧 凑 型 自 由 电 子 激 光 装 置 直 线 加 速 器 的 调 试 和 运 行 中, 束 流 能 量 发 射 度 和 轨 道 控 制 是 至 关 重 要 的 为 了 更 好 的 测 试 控 制 方 法 和 开 发 高 层 控 制 软 件, 构 建 了 一 个 基 于 ELEGANT 和 SDDS Toolkit 的 虚 拟 加 速 器 环 境 本 文 描 述 了 束 流 参 数 测 量 和 轨 道 控 制 等 软 件 在 该 虚 拟 加 速 器 环 境 中 的 开 发 和 测 试, 并 探 讨 了 该 虚 拟 加 速 器 的 设 计 理 念 和 未 来 可 能 的 应 用 关 键 词 : 虚 拟 加 速 器 环 境 ; 束 流 参 数 测 量 ; 上 层 控 制 软 件 ;