Connection and Configuration of Baudisch SIP unit with Display and RFID Reader Module



Similar documents
3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

The FlexiSchools Online Order Management System Installation Guide

VoIP Intercom and Elastix Server

Setting up the Swann HD IP cameras

Avaya IP Office SIP Configuration Guide

QUICK START GUIDE MONDOPAD/WIN

Elastix Server VoIP Intercom Setup Guide

BroadSoft BroadWorks ver. 17 SIP Configuration Guide

VoIP Intercom with Allworx 6x Server Setup Guide

Customer Tips. Configuring Color Access on the WorkCentre 7328/7335/7345 using Windows Active Directory. for the user. Overview

SNMP Manager User s Manual

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

DSA-1000 / PRT-1000 Device Server / Thermal Printer

IDDERO TOUCH PANELS. Video door phone configuration

DSA-1000 / PRT-1000 Device Server / Thermal Printer

ScanShell.Net Install Guide

The FlexiSchools Online Order Management System Installation Guide

Cisco Unified Communications Manager 5.1 SIP Configuration Guide

Configuring a Windows 2003 Server for IAS

Print Audit 6 Network Installation Guide

IDDERO TOUCH PANELS. Video door phone configuration

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: Password: 1234

Network Monitoring User Guide Pulse Appliance

CipherLab 5100 Time Attendance Utility Manual

Basic Mercury Powered NXT Configuration in Doors.NET TM Application Note. 1.0 Adding an NXT-MSC Controller to the NXT Gateway

Comtrend 1 Port Router Installation Guide CT-5072T

Training module 2 Installing VMware View

V2 Paging Amplifier PingTone Server Setup Guide

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

A: The default WAN IP address is with subnet mask

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

5 Dry Contact Cable User Manual

P-791R v2. Quick Start Guide. G.SHDSL.bis Router DEFAULT LOGIN. Administrator Password User Password. Version /2007 Edition 1

Guide to Installing BBL Crystal MIND on Windows 7

801.11n Wireless Broadband Router

Installation and Configuration of VPN Software

Algo 8180 Integration with Zultys

WLAN Outdoor CPE For 2.4G. Quick Installation Guide

The RT module VT6000 (VT6050 / VT6010) can be used to enhance the RT. performance of CANoe by distributing the real-time part of CANoe to a

PROXIMITY CARD READERS C-10, C-20, C60, C70

Medical Vacuum Systems-PXMI

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

MSSQL quick start guide

FAR 23 LOADS 6.0 Network Floating License Installation

System Area Manager. Remote Management

Quick Installation Guide. Overview. PLANET VIP-156/VIP-156PE/VIP-158 Quick Installation Guide

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

To add Citrix XenApp Client Setup for home PC/Office using the 32bit Windows client.

Technical Support Information

Version 0.1 June Xerox WorkCentre 7120 Fax over Internet Protocol (FoIP)

Reporting works by connecting reporting tools directly to the database and retrieving stored information from the database.

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

VoIP Intercom and Cisco Call Manager Server Setup Guide

How to Remotely Access Hikvision Devices User Manual

Wanos on Hyper-V Comprehensive guide for a complete lab

Network Power Manager. User Manual

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

E-Blocks Easy Internet Bundle

ITA Mail Archive Setup Guide

Phaser 3635MFP Software Upgrade Process

Adding or replacing a mesh node in an existing mesh network

Configuring Color Access on the WorkCentre 7120 Using Microsoft Active Directory Customer Tip

How to set up as VPN Network

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

Equinox L5300 Installation and Configuration Guide Version 1.0 Innovative Payment Processing Solutions for Businesses

Mondopad v1.6. Quick Start

Special Note Ethernet Connection Problems and Handling Methods (CS203 / CS468 / CS469)

Internet Telephony PBX system IPX-1980

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Allo PRI Gateway and Elastix Server

Smart Cloud Integration Pack. For System Center Operation Manager. v User's Guide

RHINO TRACKS STANDARD GPS VEHICLE TRACKER

IIS, FTP Server and Windows

SNMP Manager User s Manual

Remote Monitoring and Control of the R&S FSV with a Web Browser

NeoGate TG Series Installation Guide

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

3.5 EXTERNAL NETWORK HDD. User s Manual

Palomar College Dial-up Remote Access

Manual. Security centre ATS. Linking with Fore!

BabyWare Imperial PC Software

Metasys System Direct Connection and Dial-Up Connection Application Note

RemotelyAnywhere Getting Started Guide

NAPT. (SV8100 version 3.0 or higher)

Snom 720 and Elastix Server

Network Attached Storage User Manual

PCS300 Universal IP Reporting Module V1.0

Internet Telephony PBX System. (30/100 SIP Users registrations) IPX-330 / IPX Quick Installation Guide

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

Deployment Guide: Transparent Mode

Cloudvue Remote Desktop Client GUI User Guide

24 Port Gigabit Ethernet Web Smart Switch. Users Manual

STEP III: Enable the Wireless Network Card. STEP IV: Print out the Printer Settings pages to determine the IP Address

E-Blocks Easy RFID Bundle

VoIPon Tel: +44 (0) Fax: +44 (0)

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

VoIP Ceiling Speaker with Allworx 6x Server Setup Guide

Intel Unite Solution. Standalone User Guide

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Transcription:

Connection and Configuration of Baudisch SIP unit with Display and RFID Reader Module This document explains connection and configuration of the Baudisch sip door module with the display and RFID reader module. The integration require changing few settings on the sip module which is done by remote control Windows software developed by Baudisch. Note : It is recommend to assemble all provided components on the housing frame for easy access and strong hold while connecting cables. 1. Assemble SIP Maxi, Display and RFID reader module to the housing panel. 2. Once connected to the panel, unscrew the four Philip type screws to open back cover on all modules (C on Display module and X6 on Maxi).This gives easy access to connections. SIP Module Page 1

Display Module RFID Reader Module 3. Connect the ribbon cable provided with display module to the connection X5 on SIP module. Page 2

4. Next step is to provide power to the RFID reader module. You can either use an external 24V/50ma power supply or take power from 24VDC output connection from the SIP module. SIP module can provide 24VDC/200ma maximum power via its connections though its not good enough to power on locking components. To power on RFID reader module from SIP module connect a wire from terminal 8 on X3 to terminal 1 on RFID reader and terminal 10 on X3 to terminal 3 on RFID reader module. Please note that the terminal connections on Baudisch are not screw type. To open a contact for wiring please use a flat tip screw driver and push it upwards to open contact. (See picture below) 5. Note that RFID reader in Baudisch is a standalone component meaning that you will have to connect the door lock to both rfid reader and sip module in series. 6. Now power on sip module using POE or 24V/1A external power supply. In case of using external power supply please connect the positive wire to terminal 3 of X3 and negative to terminal 2 on X3 (picture above) on sip module. 7. Web browse to the IP address of the Baudisch sip module. Default IP address of the Baudisch is 192.168.1.200. If you have a different IP subnet/range then please use a crossover cable to connect the device directly to your computer and change the device IP address according to your requirement. This step is explained in detail on page 19 of the manual. 8. On the login page select Settings Hardware and enter login password. Default password is 1234. Page 3

9. Go to Status/Remote page and change Status and Remote to ON as shown below. Also make a note of status port, remote port and code for remote authentication password as these settings will be used when connecting from the windows software. Picture below shows the correct settings on the web page. 10. On windows machine run SIP Remote software. This software is provided as part of purchase and a download link is provided via email to allow user to downland the software. 11. On software GUI, enter the IP address of the sip module, listening port, destination port and authentication code as set in previous step. Finally enter Setup with capital S in unlock field and press open. Page 4

12. On successful connection with sip module, press the Parameter / HW-ID button. A new window will open. Enter 0x0606 in Address field and press read button. Confirm that Data [8-bit] reads 0x00 and Status say EEProm read Successful! (see picture below left). Now enter 0x03 in Data [8-bit] field and press Write button. That should write the new setting on to the EEProm. To confirm the setting has been written press Read again and that should show 0x03 in the Data field. 13. Close the window and press System Reset on main GUI. That will reboot the door phone. 14. On a reboot, the door unit is ready to be programmed.. Page 5