TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector



Similar documents
XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM4TG20 three-phase network control relay RM4-T - range V

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Redundancy Module QUINT-DIODE/40

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Analog signal converters CC-E I/I Current / current isolators

Telephone- and leased line modem for industrial applications TD-36

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Inductive sensor NI10-M18-Y1X-H1141

Three-phase monitoring relay CM-PFE

Rack mounted telephone- and leased line modem for industrial applications

38 Series - Relay interface modules A

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

MasterINTERFACE 39 Series - Relay interface modules

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Digital input modules

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

38 Series - Relay interface modules A

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

MasterINTERFACE 39 Series - Relay interface modules

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

NX safety stand-alone

Waveguide Access Point WGA631. Product Guide

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Preset Counter signo 721

Electronic overload relay EF19 and EF45

STRATO LED Drivers 70W, Single output

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Cross-beam scanning system to detect slim objects. 100 mm in

Power Supplies 3. SDN-P DIN Rail Series

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

80 Series - Modular timers 16 A. Features

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

R.C.C.B. s two-pole LEXIC

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Adjustment functions for both span and shift have been incorporated

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Description. Dimensions. Features. precision works better

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

MINI MCR-SL-R-UI(-SP)

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Electronic overload relay EF65, EF96 and EF146

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

TX OPEN RS232/485 module

Safety Manual BT50(T) Safety relay / Expansion relay

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

and Accelerometers

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

CQM1-SF200/CS1W-SF200

S-series Mass Connection Solutions

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CompactLogix Power Supplies Specifications

Thermistor motor protection

Relés e Contatores de Estado Sólido SIRIUS

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

How To Use The Vacon 0 Machinery

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

DeltaV SISnet Repeater

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Energy Management Energy Meter Type EM23 DIN

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Transcription:

Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/output number 8 Input/output number of splitter box Modicon TM7 Discrete I/O expansion block Modicon LMC058 Modicon M258 Plastic TM7 bus 24 V DC 8 I/O Complementary Discrete input number Discrete input voltage Discrete input voltage type Discrete input current Discrete input logic Discrete output number Discrete output voltage Discrete output voltage type Sensor power supply Electrical connection Local signalling Operating position Fixing mode Product weight Environment 0...8 input(s) configurable by software 24 V DC 4.4 ma Positive 0...8 output(s) at <= 0.5 A, configurable by software with transistor protection 24 V DC 24 V, 500 ma for all channels with overload, short-circuit and reverse polarity protection 8 female connectors M8-3 ways for sensor or actuator 1 male connector M8-4 ways for power IN 1 female connector M8-4 ways for power OUT 1 male connector M12 - B coding - 4 ways for bus IN 1 female connector M12 - B coding - 4 ways for bus OUT 2 LEDs for bus diagnostic 2 LEDs for sensor power supply diagnostics Any position By 2 screws 0.19 kg standards IEC 61131-2 product certifications marking ambient air temperature for operation -10...60 C ambient air temperature for storage -25...85 C relative humidity C-Tick CURus GOST-R ATEX II 3g EEx na II T5 CE 5...95 % without condensation or dripping water pollution degree 2 conforming to IEC 60664 IP degree of protection IP67 conforming to IEC 61131-2 operating altitude storage altitude vibration resistance 0...2000 m 0...3000 m 7.5 mm constant amplitude (f = 2...8 Hz) conforming to IEC 60721-3-5 Class 5M3 2 gn constant acceleration (f = 8...200 Hz) conforming to IEC 60721-3-5 Class 5M3 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 1 / 6

shock resistance 4 gn constant acceleration (f = 200...500 Hz) conforming to IEC 60721-3-5 Class 5M3 30 gn for 11 ms conforming to IEC 60721-3-5 Class 5M3 electromagnetic compatibility Conducted and radiated emissions conforming to CISPR 11 Conducted RF disturbances conforming to EN/IEC 61000-4-6 Electrostatic discharge immunity test (level: 4 kv - on contact) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test (level: 8 kv - in air) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields (level: 1 V/m - 2...2.7 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields (level: 10 V/m - 80...2000 MHz) conforming to EN/IEC 61000-4-3 Electrical fast transient/burst immunity test (level: 2 kv - power supply) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test (level: 1 kv - input/output) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test (level: 1 kv - shielded cable) conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test (level: 0.5 kv - power supply (common mode)) 1.2/50 µs shock waves immunity test (level: 1 kv - power supply (differential mode)) 1.2/50 µs shock waves immunity test (level: 0.5 kv - unshielded links (common mode)) 1.2/50 µs shock waves immunity test (level: 1 kv - unshielded links (differential mode)) 1.2/50 µs shock waves immunity test (level: 0.5 kv - shielded links (common mode)) 1.2/50 µs shock waves immunity test (level: 1 kv - shielded links (differential mode)) Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1039 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Contractual warranty Warranty period 18 months Digital Mixed Block Description (A) (B) (C) (D) TM7 bus IN connector TM7 bus OUT connector 24 Vdc power IN connector 24 Vdc power OUT connector 2 / 6

(1) Input / Output connectors (2) Status LEDs Connector and Channel Assignments I/O connectors Channel types Channels 1 Input/Output I0/Q0 2 Input/Output I1/Q1 3 Input/Output I2/Q2 4 Input/Output I3/Q3 5 Input/Output I4/Q4 6 Input/Output I5/Q5 7 Input/Output I6/Q6 8 Input/Output I7/Q7 TM7 Block, Size 1 Dimensions Spacing Requirements 1 Straight cable 2 Elbowed cable 3 / 6

Installation Guidelines TM7 Block on an Aluminium Frame NOTE: Maximum torque to fasten the required M4 screws is 0.6 N.m (5.3 lbf-in). TM7 Block on a DIN Rail NOTE: Only size 1 (smallest) blocks can be installed on DIN rail with the TM7ACMP mounting plate. TM7 Block Directly on the Machine Drilling template of the block: 4 / 6

(1) Size 1 (2) Size 2 The thickness of the base plate should be taken into consideration when defining the screw length. NOTE: Maximum torque to fasten the required M4 screws is 0.6 N.m (5.3 lbf-in). Wiring Diagram Pin Assignments for I/O Connectors Connection Pin M8 input / output 5 / 6

1 24 Vdc sensor / actuator supply 3 0 Vdc 4 DI/DO: input/output signal Wiring the Power Supply When you provide power to a TM7 I/O block using the 24 VDC Power OUT connector of the preceding I/O block, both blocks occupy the same 24 Vdc I/O power segment. However, if you connect an external isolated power supply to the 24 Vdc Power IN connector of a TM7 I/O block, you establish a new 24 Vdc I/O power segment beginning with that I/O block. I/O block wired with one external 24 Vdc power supply: (3) External fuse, Type T slow-blow, 8 A max., 250 V PS2 External isolated I/O power supply, 24 Vdc Switching Inductive Load Characteristics (1) Load resistance in Ω (2) Load inductance in H (3) Max. operating cycles / second 6 / 6