Quick start: Panic Watch EU

Similar documents
Quick start: Energy Switch EU

Z-Wave.Me Wall Controller

Z-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

Battery Wall Controller. Manual

ZME_RC2 Z-Wave Remote Control

Please refer to the chapters below for detailed information about all aspects of the products usage.

ZME_WALLC-S Z-Wave Secure Wall Controller

ST815 Illumination Sensor with LCD

Solar Powered Outdoor Siren Manual

NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55

2.0 System Description

Adding to Z-Wave TM Network

Introduction to Z-Wave. An Introductory Guide to Z-Wave Technology

Wireless Alarm system s manual

WIRELESS MAGNETIC CONTACT

Six-defense zone Display Alarm System. User Manual

ZXT-120 (Z-Wave-to-AC IR Extender) Firmware Version: V1.0 and V1.1

500r+ Installation and User Guide

Inwall 4 Input / 4 Output Module

PhoneWatch Smart Security System User Manual - Domonial

GSM Home Alarm System User Manual.

SuperGuard VT-05 Vehicle Tracking Device

USER MANUAL V5.0 ST100

Home Security Alarm System

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Advanced User s Guide

Stove Guard Kit User Manual

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Additional Instruction

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

IN-OUT Thermometer with Cable Free Sensor and Clock

Wireless Auto-dial Intruder Alarm System

Advanced User s Guide

GPS Vehicle and personal location tracker. User manual

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

DC-8706K Auto Dial Alarm System

MOBILE CALL GSM Alarm System User s Manual

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0

Hagenberg Linz Steyr Wels. API Application Programming Interface

Simon XT/XTi CDMA Module V4 Installation Instructions

Users Manual of GSM Home Alarm System with Photo-taken

GSM home alarm system s manual

User's Guide. [Home Network] app. Model No.

Falcon Protector Tracking System

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Wireless Home Security Alarm System AM 500

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

Business/Home GSM Alarm System. Installation and User Manual

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

PowerNodes. Energy Management

How To Use Vibsolas Gea

STATUS POWER MONITOR ALARM SOS DISARM

GSM Temperature Alerter. User Manual. Manual version 1.0

Car Alarm Series 2 B 2 Buttons

GSM HOME SECURITY SYSTEM

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)

MAGICAR M871A. Car alarm with two-way remote User s guide

EM6556 e-domotica Mini Switch

LYNX Touch Series Security Systems

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

4310/4320 Wireless Position Monitor Burst Configuration and Diagnostics

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

GSM Alarm System User Manual

USER MANUAL V5.0 VT300

Wireless Home Security System Product Manual (Model #80355)

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

AC-115 Compact Networked Single Door Controller. Installation and User Manual

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Intelligent GSM Auto-Dial Alarm System

Rousseau 10. User Guide

SECTION DETECTION AND ALARM

PiSector Land Line Auto Dial Professional Wireless Alarm System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

User Guide. Model: MAS-WA-SYS

Model: Manual DC: WIRELESS COLOR FORECAST STATION

FT-100 Fire Training Fog Machine User Manual English

Pocket DAB & FM Radio with Speaker

DIGITAL ALARM CLOCK RADIO

SPL 2-00/-01 OPERATION INSTRUCTIONS

AUTODIALLER / QUICKDIALLER - SA132

WASP User Manual. Revision: 1.6. (c) 2012 North Pole Engineering, Inc.

C O B A R 1 8R2 U s e r G u i d e P a g e 1. User Guide COBRA 18R2. Wireless Firing System.

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

PSTN Home Alarm System

VT600X USER MANUAL. GPS Vehicle Tracker. User Manual V5.4 VT600X

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Ademco Vista-20P/First Alert FA-168C Basic Commands

GSM ALARM SYSTEM USER MANUAL

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Installation. Powerline 500 Model XAVB5221

VEHICLE GPS TRACKER SOLUTION

User Manual of WT 493

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

EM8610 e-alarm GSM Alarm System Starter Kit

EVBIKE LCD Display Control User Guide. EVBIKE LCD Display Control User Guide

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

Transcription:

Quick start: Panic Watch EU Technical specs Normal operating voltage Frequency range Wireless Range 1x CR2032 3V battery 868.42 MHz Min 150 meters in a mesh network Basic operations - The Panic Watch can trigger any rule or lifestyle. - The Panic Watch can be configured to your needs. - The Panic Watch is easy to install and configured. - Indoor use only. - Water resistant - Big red button with time configurable activation time How it operates After a successful inclusion the Panic Watch can be used. When pressing a button the led will blink to notice the customer of successful alarm message is sent. With a controller you can make all different kind of rules and lifestyle changes. It also possible sent the alarm directly to a Z-Wave based alarm device. Use 1. Before use, the Panic Watch should be included into a Z-Wave network and associated. 2. You can Test you Panic Watch by pressing the button for 1sec untill the led is turned on. (press time is configurable) 3. Don t forget to update and syncronize your rules in the Internet Gateway. Include or Exclude in Z-Wave network 1 1. Press and hold the SOS Push Button until the indicator light starts blinking then release the button to start the inclusion or exclusion process. (Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.) 2. When classic inclusion failed, the product will start Network Wide Inclusion automatically. Force Wakeup Notification 1. When included press and hold the SOS Push Button for approx. 4 seconds. 1 Make sure your Z-Wave controller is in the correct operation mode (include or exclude).

Technical Manual: Panic Watch EU Caution: - This device is using a radio signal that passes through walls, windows and doors. The range is strongly influenced by local conditions such as large metal objects, house wiring, concrete, furniture, refrigerators, microwaves and similar items. On average, the indoor range is approximately 30 meters. - Do not expose this product to excessive heat or moisture. - Prevent long term exposure to direct sunlight. - Do not attempt to repair this product. If the product is damaged or if you are in doubt about the proper operation, take the product back to the place of purchase. - Do not clean the product with any chemical liquid. - Indoor use only. Technical details Normal operating voltage Battery lifetime Frequency range Wireless Range Storage temperature Product dimensions (Length x Width x Height) Panic Watch = 46 x 46 x 15 mm 1x CR2032 3V battery do not use rechargeable batteries >3 Years 868.42 MHz Approx. 100 meters in line of sight. Min 150 meters with good mesh network (max 4 hops). -5 C to +65 C Storage humidity 10% to 70% Operating temperature 0 C to 50 C Operating humidity: 30% to 80% Indication mode The indicator light gives various statuses of the device as follows: 1. Ready for learn mode: indicator light blinks every second. 2. Learn in progress (add): indicator light 2 times every second. 3. Learn in progress (remove): indicator light 3 times every 1.5 second. 4. Learn mode success: indicator light is on for one second. 5. RF message send success indicator light is on for one second. 6. RF message send failed indicator light blinks 6 times rapidly 7. No association is set indicator light blinks 6 times rapidly Supporting Command Classes: Basic type: BASIC_TYPE_ROUTING_SLAVE Generic type: GENERIC_TYPE_SENSOR_BINARY Specific type: SPECIFIC_TYPE_NOT_USED Listening: False, Z-Wave Lib: 4.54

class: 0x30 COMMAND_CLASS_SENSOR_BINARY class: 0x85 COMMAND_CLASS_ASSOCIATION class: 0x84 COMMAND_CLASS_WAKE_UP class: 0x86 COMMAND_CLASS_VERSION class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class: 0x70 COMMAND_CLASS_CONFIGURATION class: 0x80 COMMAND_CLASS_BATTERY class: 0x71 COMMAND_CLASS_ALARM class: 0xEF COMMAND_CLASS_MARK class: 0x20 COMMAND_CLASS_BASIC Not listening Routing SLAVE This Z-Wave product will be used as routing slave. Slave nodes are nodes in a Z-Wave network that receive commands and perform actions based on the command. This device will always be in sleep mode because it works on batteries. In sleep mode the device is not active listening, the device will wake up according to the wakeup command class. Include Initiator The include initiator is used when Primary and Inclusion Controllers include nodes into the network. When both the include initiator have been activated simultaneously the new node will be included to the network (if the node was not included previously). Exclude Initiator The exclude initiator is used by Primary Controllers to exclude nodes from the network. When the exclude initiator and a slave initiator are activated simultaneously, it will result in the slave being excluded from the network (and reset to Node ID zero). Even if the slave was not part of the network it will still be reset by this action. Z-Wave compatibility Because this is a Z-Wave device, it means it can co-operate with other Z-Wave devices of other manufacturers. It can co-exist in a Z-Wave network existing with product from other manufacturers. Hops & Retries The Z-Wave range has a range of up to 30 meters in line of sight. This signal is not limited to the 30 meter range due to routing the Z-Wave message to other nodes in the network. This way the range of the Z-Wave network can be expanded to 150 meters indoors (limit of 4 hops). class: 0x20 COMMAND_CLASS_BASIC When a button is pressed for 1sec a basic set frame with the value 255 is sent to the associated nodes. The supporting role of the basic command class is mapped to the sensor binary command class. class: 0x25 COMMAND_CLASS_SENSOR_BINARY The Sensor Binary Command Class can be used to check the status of the Panic Watch (triggered or idle). Where 255 is triggered, and 0 is idle. class: 0x86 COMMAND_CLASS_VERSION

This Command Class is used to obtain information about the Panic Watch. The Z-Wave library type, the Z- Wave protocol version and the application version will be reported. class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC This will report information about the manufacturer. This product will contain the manufacturer ID of BeNeXt. Manufacturer ID of BeNeXt is 138, the ID of this product is 21. class: 0x70 COMMAND_CLASS_CONFIGURATION Configure parameters: 0. not used 1. Set to default Param1: Param2,3,4: Set all config values to default values (factory settings). Read more in chapter Configuration Reset. if 0xFF then set to default not used 2. Time to press the Panic Watch Default: The time that the panic pushbutton must be pressed before a (panic) message is sent out to the controller. 0x64 (*10ms = 1sec) Param1: 3. Min led feedback time panic Default: Param1: 4. Buttons mapped Default: if 0x00: send directly the panic message when pressed If 0x01-0xFF: send a panic message after you keep holding the button pressed for this value x 10ms. Minimum time that led feedback is shown after a panic message 0x64 (*10ms = 1sec) if 0x00: led only stays on during the send time. If 0x01-0xFF: led stays on during send time + this value*10ms. With this config parameter you can map the buttons to send different Z-Wave messages. 0x00 (*10ms = 500ms) Param1: if 0x00: SOS button sends an ALARM_REPORT to nodes group 1 if 0x01 0xFF: SOS button sends an BASIC_SET,0xFF to nodes group 1 5. Not used 6. Not used 7. Do not use Is not used for special benext tests

* if a size is other then given size the frame is ignored totally so configuration values are not changed class: 0x85 COMMAND_CLASS_ASSOCIATION The Association Command Class is used to associate other devices with the Panic Watch. The devices that are associated can be controlled on application level. The Panic Watch can be associated into a grouping. If so, the Panic Watch can control other Z-Wave device (does not have to be a controller). The Panic Watch has 2 association groups Group 1 Maximum supported nodes: 8 If configuration parameter 4 configured with value 0 then this group is used - SOS button: send ALARM_REPORT. If configuration parameter 4 configured with value other then 0 (1-255) then this group is used - SOS button: send BASIC_SET, 0xFF. Group 2 Maximum supported nodes: 8 Not used on application Class: 0x80 COMMAND_CLASS_BATTERY This class is used to request and report battery levels for a given device. When battery level is lower then 20% the Panic Watch will send a battery warning (value 255) after every wake up notification. A battery get will report the actual value even if below 20 %. When the batteries are placed a unsolicited battery report is sent (when included). class: 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used at battery-operated devices. This class allows the Panic Watch to wake up occasionally to notify others devices, that the Panic Watch is ready to receive commands. After receiving the commands the Panic Watch will go into sleep mode again. The wake up interval can be set using the WAKE_UP_INTERVAL_SET command. The default value is 0x15180 = 86400 sec = 24 hour The default node is 0xFF = 255 (broadcast) It is possible to send a wake up notification on user interaction. To do this press and hold the Panic Watch for 11 seconds. Ignore the blinking of the led and keep the button pressed for at least 15 seconds. It is possible to send a wake up notification on user interaction. To do this press and hold the Panic Watch for4 seconds.

Operating modes The Panic Watch supports 2 different modes. Mode 1: Alarm mode This mode is mainly used to notify a controller of an alarm or trigger an alarm on a Z-Wave supported alarm device. Product can act on 2 types of handles. When single pressed (and hold): Press and hold the button, the duration to hold depends on the configured values (parameter 2) When double pressed: quickly (within 500 msec) double press the button. This mode can be configured with the following frame: Parameter: 0x04 Value: 0x00 Below figure shows an overview of the Z-Wave frames, values and association groups. When single pressed (and hold) ALARM_REPORT Value = 0xFF To assocation group 1 When double pressed ALARM_REPORT Value = 0x00 To assocation group 1

Mode 2: Control mode This mode is mainly used to control a Z-Wave other device by directly sending a BASIC_ON or BASIC_OFF. Product can act on 2 types of handles. When single pressed (and hold): Press and hold the button, the duration to hold depends on the configured values (parameter 2). When double pressed: quickly (within 500 msec) double press the button. This mode can be configured with the following frame: Parameter: 0x04 Value: 0x01 0xFF Below figure shows an overview of the Z-Wave frames, values and association groups. When single pressed (and hold) BASIC_SET Value = 0xFF To assocation group 1 When double pressed BASIC_SET Value = 0x00 To assocation group 1

Configuration Reset The Panic Watch Supports a configuration resets function. Configuration reset means - All configuration values are defaulted. This function can be activated by sending a configuration set frame: Parameter: 0x01 Value: 0xFF (can be any value except for 0x55 or 0xAA) When the value of configuration value is requested 2 possible values can be returned CONFIGURATION_REPORT Parameter: 0x01 Value 0x55: Device doesn t have all his configuration settings anymore. Even when a configuration parameter is changed back to the default value Value 0xAA: Devices still has all his factory settings. This are only configuration parameters, wake up interval can be changed. Always awake mode The always awake mode is used to request different values from the device e.g. version and manufacturer specific. The always awake mode can be activated by: Parameter: 0x05 Value: 0x03 (mode 3) The always awake mode can be deactivated by: Parameter: 0x05 Value: Any value except 3 A second option to deactivate mode 3 is 1. Remove batteries. 2. Wait ca 10 seconds. 3. Replace batteries Note: in always awake mode the batteries will be drain very fast, we do not recommend to use this mode.

Troubleshooting Frequently Asked Questions Q: I can t have my Panic Watch included into my Z-Wave network, what am I doing wrong? A: 1. Is the controller ready to include any device into the Z-Wave network? If the controller is not in Include or exclude mode, the Panic Watch will not be included or excluded. 2. The Panic Watch is already included in a Z-Wave network (check your led feedback!). Exclude the Panic Watch and try again. Q: I have configured a value but when I request it, it is not changed? A: It is mandatory that the correct size is used while configure a parameter; go to the documentation about the configuration command class to check if the right size is used during configuration. If the wrong size is used the frame is ignored totally. Q: I have configured a new value and when I request it the correct value is returned but the behavior is still the same? A: Some configuration parameters have limits of what they can do, go to the documentation about configuration to check if the value of the configured parameter is out off limit. Q: how to force a wakeup notification? A: keep the pushbutton pressed for more than 18 seconds.