MOBILE LABORATORY OF WATER LEAK DETECTION AquaLAB



Similar documents
Leica DIGISYSTEM TM Safe and fast location of underground services

Intelligent systems for locating leaks and monitoring water pipe networks

Experts in Leak Detection & Pressure Control

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Cable avoidance reaches a new level

PORTABLE FLOW METER KITS TDS-100H

Everything you need for protection scheme testing

Acoustic Leak Detection. Gander Newfoundland 2006

Hand-held thermometer Model CTH7000

O C M III. Open Channel Flow Monitor

Leakage Management & Control

Professional PC water leak correlator Perfect results thanks to fully digital technology

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Multi-Function Ground

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

OLI. Oil level indicator

Industrial Strength Leak Detection

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

IFC 070 Technical Datasheet

Open channel & partially filled pipe Ultrasonic flow meters

smart stewardship smart pipeline patented technology

Drayton Digistat +2RF/+3RF

NETWORK MANAGEMENT LEAK DETECTION. technology guide. for water network management and leakage control

Physical Specifications (Custom design available.)

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

RD2000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T1 Transmitter User Guide

Leakage Detection Using PLUMBOAT

Mobile Data Power Model: MDP-25

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Detecting Leaks in Water-Distribution Pipes

ENAiKOON ultrasonic fuel-level sensor

ATL Fuel Level Sender Probes

UNITED WATER LEAK DETECTION SERVICE

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Ground Resistance Clamp On Tester

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

USB-500/600 Series Low-Cost Data Loggers and Accessories

Interface Level And Point Level Analyzers & Sensors

SOUND LEVEL METER 94405

Next Generation Cable Avoidance Tools

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Microwave Meter. Instruction Manual

Quick Connect. quick - simple - efficient.

HERZ-Thermal Actuators

Current Monitoring Kit

User's Guide. Integrating Sound Level Datalogger. Model Introduction

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Thyristor-controlled power supplies and battery chargers

How To Use A Detector 2

How To Sell A Talan

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

technology for network management and leakage control

PowerGem Pro Uninterruptible Power Supply

Hydrogen Leak Detection XRS system. The complete system for leak detection using hydrogen gas

Problem / Solution. The problem:

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Cable Test Module ( HVT-25) Single-phase connection to object

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Hydraulic Control Solutions

MODEL 2202IQ (1991-MSRP $549.00)

Stroom voor elke toepassing

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

TMS TANK MANAGEMENT SYSTEM

USB-500 Series Low-Cost Data Loggers and Accessories

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Current Monitoring Kit QUICK START GUIDE

Advanced Systems Tester 900AST

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Acoustic Leak Detection for Water Distribution Systems

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content INTRODUCTION Dear customer... 2 Features... 2 Caution... 2

T5000 T000 LCD Digital Fan Coil Thermostat

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

1.44 kw Programmable DC Power Supplies XLN Series

Products. Water Leak Detection WATER LOSS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Instruments for the oil & gas industry

PowerPAC. Substation Reliability Services and Products

How To Read A Pipe From A Sensor

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Temperature & Humidity SMS Alert Controller

Operating Instructions

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

How To Program An Autodialer

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Fiber Optic Distributed Temperature Sensor (B-DTS)

How To Use A Ds340 (Dsp)

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

CELLOCATOR TM ACCESSORIES. The Cellocator Difference

Full workday of talk time 8 hours wideband and 12 hours narrowband Two years warranty for peace of mind

Highly efficient flue gas analyzer

Transcription:

MOBILE LABORATORY OF WATER LEAK DETECTION AquaLAB In most water-distribution systems and pipelines, a large percentage of the water is lost in transit from treatment plants to consumers. Factors that contribute to this loss are old and poorly constructed pipelines, inadequate corrosion protection, poorly maintained valves and mechanical damage. Our water leak detection test van is a cost-effective way to conserve water, save lost revenue, and control unnecessary costs. Early detection of leaks reduces the possibility of public health risks and the potential for major property damage. Utilizing state-of-the-art equipment the water leak detection test van is capable of locating and exposing the exact location of hidden underground water leakages. Further, our investigative procedures are non invasive/non destructive and can detect and identify the damage locations without digging or trenching. LABORATORY FEATURES: Determines the pipeline route of a water supply network; Checks up valves and gates for the presence of leakages; Measures the water flow in a section of the pipeline; Pinpoints the place of water leakages; Stores data for graphing, processing and later analysis.

A. ACCURATE PINPOINTING OF UNDERGROUND FLUID LEAKS Advanced system for the accurate pinpointing of underground fluid leaks, prior to excavation Eureka2. The system has been proven to perform world-wide and can be used effectively on all types of pipe not only metallic, but also plastic and asbestos cement. Benefits: Fast and simple, enabling rapid leak location Optimum correlation performance Palm-top size and weight Rugged construction for routine operations Fast-Track or Advanced operation. Eureka 2R can be used in two modes Fast- Track or Advanced. The Fast-Track mode can be used quickly and reliably, involving only three operations for basic leak pin-pointing. The Advanced mode incorporates features such as unwanted noise suppression, velocity calculation, filter adjustment, display zoom and saving results. The correlation display is shown directly as distance (unlike most correlators where a display of time-delay is used). This has the benefit, particularly in multiple pipe situations, of giving a displayed result directly proportional to distance on the ground. Features Automatic and manual filter selection Unwanted noise suppression Fast, automatic battery charging from mains or vehicle; minimizes equipment down-time Built-in language options Software upgradeable Convenient in-case battery charger

B. ULTRASONIC FLOW METERING SYSTEM PrimeFlo is a rugged ultrasonic flowmeter utilising advanced signal transmission. PrimeFlo automatically uses both Transit-Time and Doppler measurement modes. It is for use on a wide range of pipe sizes and materials in clean and dirty water applications. Benefits Use on pipe sizes from 10 to 2500mm (two transducers required) Easy to install clamp-on sensors with no process interruption Non-invasive measurement no flow disturbance or pressure loss Accurate and repeatable measurements even at low flows Self powered for 24 hours Application PrimeFlo utilises advanced digital design to meet the practical needs of engineers for measuring flow-rates and total flow at multiple points on water networks. Applications include Water network management Minimum night-flow measurement Flow surveys Pump flow control In-situ meter validation PrimeFlo is designed for use in harsh environments. The case is made of ruggedised ABS plastic giving ingress protection to IP67 (lid closed). Cables and sensors are protected to IP68. Programming is user-friendly via the integral keypad and display. PrimeFlo may be powered from mains or an internal rechargeable battery. This has an operational life of 24 hours which makes it suitable for temporary flow monitoring. It connects easily to the full range of Primayer data loggers.

Features: Dual mode Transit Time and Doppler Real-time display of flow-rate, total flow and sound velocity Accuracy to ±0.5% or ±0.02m/s whichever is the greater (with process calibration) Integral data logger or connection to Primayer data loggers Portable, lightweight and easy to use Data imported into PrimeWorks software for graphing, processing and storage Outputs for process control interfacing Mains power or battery operation Wall thickness gauge C. ACOUSTIC LEAK DETECTION SYSTEM Phocus 2 is an intelligent acoustic data logger system designed for widespread use in detecting and localizing leakage on water distribution systems. Large areas may be rapidly assessed. Phocus2 gives visual, on-site indication of leakage or can be used with sophisticated software to produce graphical and tabular results. Phocus2 advantages: Rapid, overnight, identification of leaks - without the need for staff night working Use for survey or permanent operation Large areas can be covered quickly Intelligence built into logger for instant, on-site, indication of leakage Advanced analysis PC software Operation Leak pre-location is carried out by installation of a number of Phocus2 loggers at available fittings such as hydrants or valves. The loggers record leak noise during the night, when background noise is likely to be lower. Noise amplitude will vary due to random effects, but there will always be a consistent minimum (the critical noise level) due to any constant noise for example, leakage.

Loggers which are situated closer to a leak will record a higher critical noise level. The leak can then be pinpointed (usually by using the leak noise correlation technique). The System The Phocus2 system consists of a number of acoustic noise loggers. A communications case is required to program and readback loggers. The case has the contact-less communications facility built into the lid. Loggers may be placed in any position and the PC software automatically identifies each logger. The case provides for communication for up to 15 loggers at the same time and the cases may be connected to build a system with any number of loggers. Visual indication provides instant on-site awareness of the leakage situation. Logger Features Specially optimized accelerometer with high sensitivity Large memory - stores up to one year of noise data Powered for life (5-10 years) Small size - only 90mm high Submersible (to IP68) Rapid, contact-less communications to multiple loggers Data Analysis The sophisticated PC software automatically identifies each logger and enables the simple programming and read-back of multiple loggers. The results are displayed as two or three dimensional graphs of the characteristic noise and provide easy to interpret analysis. Additionally, a table ranks logger position relative to the leak position.

The Cable Avoidance Tool (CAT) is a full function, industry standard locator which every ground working operative will find familiar and easy to use. It is rugged, lightweight and full of features. D. PRECISION PIPE LOCATOR LCD meter - precision locating as standard Detachable loudspeaker - held next to the ear in noisy work situations Fingertip controls - adjust sensitivity and rapid switching between the locator s three operating modes Two models available Standard model XD model with depth indication Advantages Visual Display provides greater precision and offers improved operation for accurate direction and splitting close signals Spare battery pack included Constant battery level indicator Customer replaceable speaker assembly SPECIFICATION CSCAT-33 Cable Avoidance Tool Controls On/Off control, activated when in use Three position function switch: P - POWER mode for live, imbalanced cables R - RADIO mode for re-radiated radio signals G - GENERATOR mode for detecting conductors carrying the Generator signal Detachable (user replaceable) loudspeaker User replaceable base protector Display Signal strength, battery condition, operating mode Depth of detection Detects to the following depths: P-3 metres R-2 metres G-3 metres These values are provided for information only and performance depends on the site (terrain, temperature, humidity, etc). Batteries (not included) Type: 8 x AA (IEC type LR6) Life: 40 hours (at 20 C) Check: an audio signal indicates that the batteries have sufficient power when the receiver is first turned on. During use, a battery check facility is displayed. Weight: 3kg (including batteries) Moisture/Dust resistant: IP65

ZCSSGSGA-33 Signal Generator Enhance detect-ability of pipes and cables. Use to transmit an easily identifiable signal along a pipe or cable. The Cable Avoidance Tool uses industry accepted 33kHz frequency for clear reception. CSCATXD-33 Cable Avoidance Tool + Depth Indication Includes features of the standard CAT with additional depth option Depth push button: in G mode only gives a depth indication Battery check Depth measurement Active in G Mode only Range: 0.25 3.0m (Line) 1.0 6.0m (Sonde) Visual indicator Large, high accuracy, LCD with ruggedised mounting. Mounted behind a polycarbonate lens for maximum protection. Controls On/Off Signal level rotary control Pulse/continuous selection switch Volume switch Typical tracing range Induced mode: 200 metres Direct connected mode: 350 metres Frequency: 33kHz pulsed/continuous Batteries (not included) Type: 4 x D cells (IEC type LR20) Life: 30 hours intermittent use at 20 C E. ACOUSTIC LEAK LOCATION SYSTEM Mikron is a high performance, simple to use leak locator. The design is based upon an advanced sensor and incorporates low-noise processing electronics to give excellent acoustic performance over a wide frequency range. Mikron incorporates a Minimum Noise Level measurement system. Principle Mikron detects noise generated by leaks in water pipes. The leak noise travels through the water and pipe wall and can be detected by listening at valves or hydrants. Leak noise also propagates from the leak to the ground surface where it can be detected using the sensitive ground microphone.

Features Very high acoustic sensitivity Acoustic probe, ground microphone and combined system options Advanced ground microphone with wind-noise isolation Minimum Noise Level measurement Lightweight amplifier with clear digital display Simple to use Minimum Noise Level digital display To enable accurate leak pinpointing Mikron displays the Minimum Noise Level, i.e. the background noise level which will potentially include the leak noise, but without transient noises, such as road traffic. Mikron also displays the two previous Minimum Noise Level measurements such that the user can easily tell if they are moving toward or away from a leak. The current sound level, volume position and battery charge are also displayed. Advanced amplifier The small, lightweight amplifier unit can be held in one hand. The display is easy to read and includes the following range of filters for operation in different leak location conditions. Flexible performance In the ground microphone system the high performance sensor is suspended thus drastically reducing interference from wind or other sources of airborne noise. The acoustic probe system can be configured as an electronic listening stick or ground microphone and includes a tripod for use on hard ground, spike for use on soft ground and optional magnet. The systems are rugged and use military grade connectors for sensor and battery charging. Rechargeable batteries provide approximately 35 hours operation (without backlight).

F. LEAK SIZER SYSTEM Leak Sizer is an advanced instrument for leak location and for the determination of leak size probability. Prioritise repairs to reduce leakage losses Reduce repair costs High sensitivity to detect quiet leaks Minimum noise level display Multiple leak noise sound recording Leak noise spectrum display Methodology Once the leak position has been determined then the Leak Sizer operation commences. The process is as follows: Collect 30 seconds of acoustic data from the ground surface immediately above the estimated leak position Enter estimate of network pressure Optionally collect 30 seconds of acoustic data from pipe fitting close to the leak such as a valve or stop tap Results The algorithms within the Leak Sizer software then analyse this data to extract a range of key features which can be correlated probabilistically against leak size. The sizing process is divided into two categories; communication/services pipes (less than 50mm) and mains pipes (greater than 50mm). The leak size estimate probability is displayed in three categories for the smaller pipes and into two categories for the larger pipes. Research data Leak Sizer is the result of over two years research carried out in the South West Water company in the UK. This research included measurement of over 370 actual leaks. A wide variety of pipe materials and soil types were assessed. The light blue line on the graph shows average performance, ie. what should happen if leaks are repaired in random order. The yellow line shows the Leak Sizer performance and the green line the theoretical ideal performance.

Sensor characteristics High performance accelerometer Acoustic data digitised at accelerometer Bluetooth data transmission to PDA for data processing Battery life 40 hours (rechargeable) System components Advanced ground sensor with Bluetooth communications Large mass for constant acoustic coupling with ground surface (for leak sizing) Tripod attachment for surface listening (+ soft ground spike) PDA with rugged case + Leak Sizer software Connecting rods + handle High performance headphones The notebook provides an interface for data acquisition, data analysis and data storage for the mobile laboratory of water leak detection. G. NOTEBOOK Along with the test van a tool set is provided. It includes: Electro drill with puncher 500W Hammer Butts set (5, 6, 7, 8, 9, 10, 11, 12, 13 mm) Wire cutters Flat-nose pliers Screw-driver with a set of bats Roulette 5 m. Adjustable spanner Knife Drills Hard alloy drills Hack-saw for metal H. TOOL SET I. POWER SUPPLY This modern gasoline generator is ideal for independent work on construction sites and for industrial, commercial or private operation. With a large fuel tank it guarantees up to 8 hours running time and offers excellent performance and at the same time it is very safe to use.

TECHNICAL SPECIFICATIONS Engine: Honda GX 390 Super Silent Cylinder: 1 Speed: 3000 rpm Fuel: Gasoline Engine oil capacity: 1.3 l Cooling Air / Air (Eng./Generator): Electr. capacity 1~ φ 6450 VA 1.0: Voltage 1~: 230 V Max. Current 1~: 28 A Current 1~ (CEE): 28 A Current 1~ (Schuko): 16 A Max. starting current 16 A cos φ 0,6: Starting current with 45 A 20% voltage drop: Frequency: 50hz Tank capacity: 20 I Weight: 95.5/104.5 kg incl. batt. Dimensions 740x500x530 mm (L x W x H) : Acoustic power L WA: 97 db(a) Acoustic pressure (10m 69 db(a) no load): J. VEHICLE Chassis: The basic types of chassis used are: Mercedes Sprinter, Iveco Daily, Ford Transit etc. Vehicle Body The mobile laboratory is designed to be easy to operate and service. It is equipped with high quality insulated wall panelling and air conditioning. The body is divided into technical and operator compartments separated by a partition wall. The technical compartment includes all the necessary tools and equipment for carrying out testing and inspections. Safety is an important

feature of the laboratories and hence all equipment is properly mounted and secured for transit. The operator compartment provides a pleasant environment to work in with more room and plenty of storage. It is equipped with cabinetry and workbenches that increase the operators efficiency and productivity. FEATURES Roof mounted air conditioner Internal lighting 230 VAC & 12V DC Insulated walls and roof for thermal and noise Special PVC floor in operator area Special aluminium tread plate suitable for rough loading in technical area Partition wall, Operating desk & Swivel chair Drawers for storage of accessories Set documentation of the laboratory is included. K. DOCUMENTATION L. WARRANTY Our laboratories are covered by a warranty for a period of one year. At the end of this period, the manufacturer can provide upon request an after-sales service of the equipment. Contact information: Tel.: +357 24821788; Fax: +357 24821787, Mob.: + 357 99556229, For letter: P.O.Box 41016, Larnaca 6308, Cyprus Factory: Larnaka, Cyprus www.vitaldrive.net